OCEAN ENCOUNTERS

OCEAN ENCOUNTERS is a 1973 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1985, most recently in September 2025, along with 73 deficiencies and 1 casualty investigation in 2013.

Records from 1985 to 2025. Most recent: inspection, 23 September 2025.

Built
1973
Last inspected
23 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ7167
Flag
UNITED STATES
368003990
Maury page id
psix-47544

Inspections, by type

…with no type recorded11
Years with a record 28 calendar years (1985–2025)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)41.8 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 26 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE WA, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKONA, HI
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 16 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ7167MMSI 368003990 · active · compulsorily equipped · granted 22 August 2017, expires 22 August 2027
WDG4135MMSI 367533340 · expired · compulsorily equipped · granted 1 June 2012, cancelled 6 August 2022 · licensed under a name not among this hull’s recorded names (not shown)
WDB4420MMSI 366898240 · expired · compulsorily equipped · granted 17 June 2003, cancelled 17 August 2013 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 61

23 September 2025 Examination of Repairs · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8240028
4 September 2025 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8228077
7 October 2024 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8016492
30 March 2024 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7893233
2 November 2023 Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7830307
12 October 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7807852
23 May 2023 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7694812
11 November 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7593169
12 July 2022 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7504716
1 March 2022 In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7413277
28 September 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7344237
31 May 2021 In-Service Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7226256
9 November 2020 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7097313
3 June 2020 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6966621
6 December 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6871582
16 October 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6835239
15 April 2019 Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6705032
11 November 2018 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6582335
1 November 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6570807
2 May 2018 Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6411495
2 August 2017 COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6221892
21 November 2016 Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6043253
15 April 2016 Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5913871
24 September 2015 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5792572
29 October 2014 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5015983
16 August 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2436015
2 May 2005 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2347568
26 February 2004 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2021556
28 May 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1811371
24 April 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1777836
28 January 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1481148
4 August 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1052817
4 August 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1053675
12 July 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361601
12 July 2000 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369787
6 January 2000 Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 1518084
2 March 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 855341
6 April 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1435470
2 March 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356534
4 May 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 836617
4 March 1993 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 836558
12 February 1993 Hull Examination · Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 826256
26 November 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 128331
26 November 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 171294
8 June 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 946031
5 February 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 953969
19 December 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 952568
6 March 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 908659
24 July 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 913964
14 May 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1240589
8 March 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1227785
19 May 1989 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1352766
7 March 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1345318
25 May 1988 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1199491
10 March 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1307408
20 May 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1025929
12 March 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1014632
22 April 1986 Credit Drydock · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1001054
25 June 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 987704
18 April 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 983758
19 March 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 979940

Deficiency record · 73

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 September 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect crew, other persons and the vessel from electrical hazards. Need to cap or remove dead end wires located in No. 1 void space with 12V batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 16 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 September 2025 Resolved
As appropriate for intended voyage, vessels must carry adequate and up-to-date: -U.S. Coast Pilot -Tide Tables -USCG Light List -Current Tables Must keep onboard and made available to vessel master.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 16 September 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 October 2024 Resolved
Vessel operators must be prepared to conduct tests of all fire fighting equipment including fixed systems at each inspection for certification. Vessel's main engines failed to re start in over-ride mode when shut-down from simulated test of Fireboy system. Must rectify to of USCG prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 November 2022 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. No mast light present and upper most red light is inadequate for restricted in her ability to maneuver, light was very dim. Provide navigation mast light and proper light for restricted in her ability to maneuver that is in compliance with the Navigation Rules.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2022
Resolved 12 November 2022
Resolution: proper installation made and witnessed by marine inspector
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 July 2022 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. No stern light. Provide navigation lights that are in compliance with the Navigation Rules. Temporary stern light installed until permanent stern light can be placed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 14 July 2022
Resolution: Permanent stern light installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 July 2022 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Multiple holes through fwd engine room bulkhead due to unsealed wire penetrations and previous penetrations left open and head allow fixed fire extinguishing medium to communicate through bulkhead. Make vapor tight to ensure quantity of extinguisher is sufficient.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 14 July 2022
Resolution: All openings in engine room fwd bulkhead made vapor tight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is short of 2 adult life jackets per COI total persons. Vessel total persons carrying capacity is limited to no more than 38 total persons.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 20 July 2022
Resolution: 2 additional lifejackets provided.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 12 July 2022 Resolved
Electrical equipment exposed to the weather must be watertight. Bus bar connection is on open deck without watertight enclosure.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2022
Resolved 13 July 2022
Resolution: Electrical connections made watertight.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 July 2022 Resolved
Bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris or other matter that might create a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: Oil soaked absorbent pads removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 12 July 2022 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load pf 50 pounds per foot applied to the top rail in any direction. Stanchions on upper deck port and aft rails are loose and will not hold a point load of 200 pounds. Tighten stanchions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 20 July 2022
Resolution: Stanchions reinforced with additional bolts.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 12 July 2022 Resolved
On passenger decks of a vessel on an excursion trip the following must be installed: Rail courses spaced at intervals of not more than 4 inches. Rail courses are greater than 4 inches just aft of pilot house going forward on both sides.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 20 July 2022
Resolution: Required 4 inch courses installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2022 Resolved
All observed unsafe practices and hazardous situations must be corrected. Battery terminals are covered with corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 14 July 2022
Resolution: Corrosion removed from all battery posts.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2022 Resolved
Electrical equipment exposed to the weather must be watertight. Mast rise above the pilot house is allowing water ingress due to electrical wiring penetration through holed mast rise and it is not watertight and does not have a watertight conduit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 14 July 2022
Resolution: Hole sealed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 July 2022 Resolved
A weathertight door must be provided for each opening located in a deck house. Port and stbd doors are delaminating at the ends, not properly hinged, not gasketed and no door handles for access. Also provide cover for deck chain storage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 20 July 2022
Resolution: Both doors rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy has hole and foam is exposed. Replace life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: Replaced with a new ring buoy.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 July 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Midship bilge alarm light is not operational.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: New alarm installed and tested satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 May 2021 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. The vessel did not conduct a dry dock inspection before the vessel's anniversary date. The vessel needs to conduct a credited dry dock.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2021
Resolution: Vessel conducted a credited dry dock.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 August 2017 Resolved
Vessel needs to configure its bilge pumps and bilge high level alarm in two independent systems separate of each other.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 2 September 2017
Resolution: The vessel configured its bilge pumps and high level alarms into two independent systems.
Communications › Radio Communications › EPIRB
Issued 2 August 2017 Resolved
Vessel needs to install a new hydrostatic release unit for its EPIRB.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 2 September 2017
Resolution: A new hydrostatic release was installed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 August 2017 Resolved
Vessel needs to have its full FCC Safety Certificate renewed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 2 September 2017
Resolution: The company renewed the vessel's FCC Safety Certificate.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 2 August 2017 Resolved
Vessel needs to incorporate in-water emergency procedures to the vessels instruction list.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 2 September 2017
Resolution: The company has revised and posted the vessel's instruction list to include in-water emergency procedures.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 21 November 2016 Resolved
Vessel’s pre-engineered fire extinguishing unit needs to be in working order.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2016
Resolved 30 November 2016
Resolution: The vessel's pre-engineered fire extinguishing unit is in working order.
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 November 2016 Resolved
Vessel needs to conduct satisfactory sea trials and perform the required drills.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2016
Resolved 30 November 2016
Resolution: The vessel conducted satisfactory fire and abandonship drills.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 21 November 2016 Resolved
Vessel fuel strainers need to be equipped with proper flame protection.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2016
Resolved 30 November 2016
Resolution: The vessel outfitted proper flame protection under the fuel strainers.
Documentation › Certificates/Documents › Permit, Other
Issued 21 November 2016 Resolved
Vessel operator needs to provide proof of valid radio operator permit.
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 21 December 2016
Resolution: The vessel operator provided proof of a valid FCC Radio Operator Permit.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 November 2016 Resolved
Vessel needs to have an approved Class D VHF radio installed onboard the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 21 December 2016
Resolution: The vessel has been outfitted with a working Class D Radio.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 July 2005 Resolved
Provide water light for ring buoy and stencil name of vessel on ring bouy IAW 46 CFR180.70.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 16 August 2005
Lifesaving › Hand Flares › Not on Board
Issued 22 July 2005 Resolved
Provide (2) orange day smoke and (1) red hand flare IAW 46CFR180.68.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 7 June 2012
Operations/Management › Drills/Instruction › Fire
Issued 22 July 2005 Resolved
Provide logs that include fire & man overboard drills, and lifesaving equipment checks IAW 46CFR185.524.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 16 August 2005
Documentation › Certificates/Documents › FCC SSL
Issued 22 July 2005 Resolved
Provide marine radio operator permit for either master or crewman IAW 46CFR185.402.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 16 August 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 July 2005 Resolved
Provide required navigation publications: Charts, US Coast Pilot, CG light list, tide tables and tidal current tables IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 7 June 2012
Communications › Radio Communications › EPIRB
Issued 22 July 2005 Resolved
Provide proof of NOAA registration for EPIRB IAW 46CFR184.502.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 16 August 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 July 2005 Resolved
Provide required items for first aid kit IAW 46CFR184.710.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 16 August 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 July 2005 Resolved
Remove or properly repair dead end wires located at operating station and engine room IAW 46CFR183.340.
Condition: Placed in Improper Service
Due 16 August 2005
Resolved 16 August 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 22 July 2005 Resolved
Install and prove proper operation of high water alarms and steering space IAW 46CFR182.530.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 7 June 2012
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 22 July 2005 Resolved
Properly install emergency fuel shut off valves outside of engine space IAW 46CFR182.455.
Condition: Design Flaw
Due 16 August 2005
Resolved 16 August 2005
Engineering › Steering Gear System › Piping
Issued 22 July 2005 Resolved
Replace severly corroded fittings for hydraulic steering lines and install handle for cutoff valve IAW 46CFR 182.710.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 16 August 2005
Construction/Loadline › Structures › Ventilators
Issued 22 July 2005 Resolved
Provide dogs for port light located in port head IAW 46CFR179.360.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 16 August 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 July 2005 Resolved
Provide metal fasterns for wiring located in engine romm IAW 46CFR183.340.
Condition: Unknown
Due 16 August 2005
Resolved 16 August 2005
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 22 July 2005 Resolved
Provide battery box covers IAW 46CFR 183.350.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 16 August 2005
Stability › Incline Test › General
Issued 22 July 2005 Resolved
Provide stability letter IAW 46CFR176.306.
Condition: Unknown
Due 16 August 2005
Resolved 16 August 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 22 July 2005 Resolved
Install engine room vent dampers IAW 46CFR181.420.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 7 June 2012
Engineering › Bilge Water Management System › Piping
Issued 22 July 2005 Resolved
Install suction strainers IAW 46CFR182.510.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 7 June 2012
Lifesaving › Buoyant Apparatus › Painter
Issued 22 July 2005 Resolved
Replace sea painter, provide light and stencil vessel name on lifefloat IAW 46CFR180.175.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 7 June 2012
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 22 July 2005 Resolved
Stencil "No Passengers allowed in berthing space" IAW 46CFR177.500
Condition: Design Flaw
Due 16 August 2005
Resolved 16 August 2005
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 22 July 2005 Resolved
Replace flex hose for stbd fule system IAW original plans or where flexible hose is installed hose must meet J-1942 standards IAW 46CFR182.720.
Condition: Improper Installation
Due 16 August 2005
Resolved 7 June 2012
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 July 2005 Resolved
Vessel must complete fire and man overboard drills IAW 46CFR185.524.
Condition: Improper/Lack of Maintenance
Due 16 August 2005
Resolved 16 August 2005
Documentation › Certificates/Documents
Issued 24 April 2003 Resolved
Provide FCC Station Licience. LEGACY COMPONENT DESC: FCC SSL
Due 24 June 2003
Resolved 17 June 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 24 April 2003 Resolved
Provide emergency fuel shutoff valve for starboard engine. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2003
Lifesaving › Buoyant Apparatus
Issued 24 April 2003 Resolved
Prove float free configuration on life float stowage arrangement. Provide two 4' paddles for each lifefloat. Affix name of vessel on to lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2003
Resolved 28 May 2003
Resolution: Rep stated he had completed item, only inspector not available to verify until this date.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 24 April 2003 Resolved
Provide a portable bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2003
Resolution: On 5/28/03 Rep had onboard an unsat pump. Hose not long enough. 5/29/03 Rep had onboard sat pump with long enough hose to dewater all compartments.
Navigation › Piloting/Steering
Issued 24 April 2003 Resolved
Provide coast pilot and light list. LEGACY COMPONENT DESC: US Coast Pilot
Due 24 May 2003
Resolved 28 May 2003
Fire Fighting › Nozzles
Issued 24 April 2003 Resolved
Provide a nozzel for the fire hose and insure the fire hose is of adequate length to reach all area's of the vessel. LEGACY COMPONENT DESC: Condition
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2003
Resolution: Corrected by rep prior to this date, only verified by inspector on 5/28/03.
Lifesaving
Issued 12 July 2000 Resolved
Provide properly labeled container for distress signals IAW 46CFR185.614.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Lifesaving
Issued 12 July 2000 Resolved
Provide/Replace white ringbuoy with one of an orange color and waterlight and proper line attached IAW46CFR180.70. Vessel is restricted to daylight operation until waterlight is provided for ring bouy.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Accommodation/Occupational Safety
Issued 12 July 2000 Resolved
Properly lable FWD Escape Hatch IAW 46CFR185.606.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Construction/Loadline
Issued 12 July 2000 Resolved
Attach Engine Room and Steering Compartment hatch cover to the vessel IAW46CFR179.360(b)(2).
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Construction/Loadline
Issued 12 July 2000 Resolved
Make AFT bulkhead of Engine Room watertight IAW 46CFR179.320.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Lifesaving
Issued 12 July 2000 Resolved
Provide a waterlight for Lifefloat IAW 46CFR180.175. Vessel is restricted to daylight operations until this requirement is met.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Documentation
Issued 12 July 2000 Resolved
Provide FCC Safety Radio Certificate IAW 46CFR184.502.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Accommodation/Occupational Safety
Issued 2 March 1994 Resolved
MAKE PERMANENT REPAIRS TO LEAKING FLEX COUPLING ON MSD STORAGE TANK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Lifesaving
Issued 2 March 1994 Resolved
PROVIDE A TOTAL OF 4 (FOUR), TYPE I, CHILD SIZED PFD's. VESSEL IS RESTRICTED TO CARRIAGE OF NOT MORE THAN 30 PERSONS PENDING COMPLIANCE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Accommodation/Occupational Safety
Issued 2 March 1994 Resolved
RENEW SAFETY GLASS TO CENTER BRIDGE WINDSHIELD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Engineering
Issued 4 March 1993 Resolved
MAKE ACCESSIBLE AND PROPERLY LABEL REMOTE FUEL SHUT-OFF VALVES.
Condition: Unknown
Due 4 March 1993
Resolved 4 March 1993
Engineering
Issued 4 March 1993 Resolved
MOUNT THE REMOTE FUEL SHUT-OFF ACCESS WRENCH IN THE IMMEDIATE VICINITY OF THE REMOTE FUEL SHUT-OFF VALVES.
Condition: Unknown
Due 4 March 1993
Resolved 4 March 1993
Documentation
Issued 5 February 1992 Resolved
CONDUCT IN THE PRESENCE OF A MARINE INSPECTOR A SIMPLIFIED STABILITY TEST IN ACCORDANCE WITH THE PROVISIONS IN 46 CFR 171.030.
Condition: Unknown
Due 5 February 1992
Resolved 5 February 1992
Accommodation/Occupational Safety
Issued 14 May 1990 Resolved
RENEW/REPLACE PORT RAIL STANCHION PLATE OUTBOARD OF PILOTHOUSE.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Construction/Loadline
Issued 14 May 1990 Resolved
GRIND OUT SURFACE ROT FROM TRANSVERSE FRAME IN ENGINEROOM OVERHEAD, PORT SIDE AFT.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Construction/Loadline
Issued 14 May 1990 Resolved
EFFECT PERMANENT REPAIRS TO CRACKED FORWARD WEATHER DECK HATCH COVER.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Construction/Loadline
Issued 18 April 1985 Resolved
SUBMIT A MODIFICATION FOR HATCH COVERS OVER ENGINEROOM TO PROVIDE A WATERTIGHT CLOSURE. TEMPORARY REPAIRS ARE TO BE MONITORED AND MAINTAINED BY THE OPERATOR.
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985
Unknown
Issued 19 March 1985 Resolved
INDICATE BY LABEL THAT PASSENGERS ARE NOT ALLOWED IN BELOW DECK SPACE OR PROVIDE AUTOMATIC EMERGENCY LIGHTING.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Navigation
Issued 19 March 1985 Resolved
REPAIR STEERING ARM AT HYDRAULIC RAM TO REMOVE EXCESSIVE PLAY.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Construction/Loadline
Issued 19 March 1985 Resolved
PROVE HATCHES OVER ENGINE COMPARTMENT ARE WATERTIGHT.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985

Casualty record · 1

26 February 2013Routine · role: Involved in a Marine Casualty · activity 4547115
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.