Records from 2013 to 2025. Most recent: inspection, 23 September 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 23
23 September 2025
Examination of Repairs · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8240028
4 September 2025
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8228077
7 October 2024
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8016492
30 March 2024
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7893233
2 November 2023
Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7830307
12 October 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7807852
23 May 2023
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7694812
11 November 2022
Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7593169
12 July 2022
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7504716
1 March 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7413277
28 September 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7344237
31 May 2021
In-Service Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7226256
9 November 2020
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7097313
3 June 2020
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6966621
6 December 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6871582
16 October 2019
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6835239
15 April 2019
Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6705032
11 November 2018
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6582335
1 November 2018
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6570807
2 May 2018
Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6411495
2 August 2017
COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6221892
21 November 2016
Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6043253
15 April 2016
Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5913871
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 September 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect crew, other persons and the vessel from electrical hazards. Need to cap or remove dead end wires located in No. 1 void space with 12V batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 16 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 September 2025
Resolved
As appropriate for intended voyage, vessels must carry adequate and up-to-date:
-U.S. Coast Pilot
-Tide Tables
-USCG Light List
-Current Tables
Must keep onboard and made available to vessel master.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 16 September 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 October 2024
Resolved
Vessel operators must be prepared to conduct tests of all fire fighting equipment including fixed systems at each inspection for certification. Vessel's main engines failed to re start in over-ride mode when shut-down from
simulated test of Fireboy system. Must rectify to
of USCG prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 November 2022
Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. No mast light present and upper most red light is inadequate for restricted in her ability to maneuver, light was very dim. Provide navigation mast light and proper light for restricted in her ability to maneuver that is in compliance with the Navigation Rules.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2022
Resolved 12 November 2022
Resolution: proper installation made and witnessed by marine inspector
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 July 2022
Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. No stern light. Provide navigation lights that are in compliance with the Navigation Rules. Temporary stern light installed until permanent stern light can be placed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 14 July 2022
Resolution: Permanent stern light installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 July 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Multiple holes through fwd engine room bulkhead due to unsealed wire penetrations and previous penetrations left open and head allow fixed fire extinguishing medium to communicate through bulkhead. Make vapor tight to ensure quantity of extinguisher is sufficient.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 14 July 2022
Resolution: All openings in engine room fwd bulkhead made vapor tight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is short of 2 adult life jackets per COI total persons. Vessel total persons carrying capacity is limited to no more than 38 total persons.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 20 July 2022
Resolution: 2 additional lifejackets provided.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 12 July 2022
Resolved
Electrical equipment exposed to the weather must be watertight. Bus bar connection is on open deck without watertight enclosure.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2022
Resolved 13 July 2022
Resolution: Electrical connections made watertight.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 July 2022
Resolved
Bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris
or other matter that might create a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: Oil soaked absorbent pads removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 12 July 2022
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load pf 50 pounds per foot applied to the top rail in any direction. Stanchions on upper deck port and aft rails are loose and will not hold a point load of 200 pounds. Tighten stanchions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 20 July 2022
Resolution: Stanchions reinforced with additional bolts.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 12 July 2022
Resolved
On passenger decks of a vessel on an excursion trip the following must be installed: Rail courses spaced at intervals of not more than 4 inches. Rail courses are greater than 4 inches just aft of pilot house going forward on both sides.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 20 July 2022
Resolution: Required 4 inch courses installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2022
Resolved
All observed unsafe practices and hazardous situations must be corrected. Battery terminals are covered with corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 14 July 2022
Resolution: Corrosion removed from all battery posts.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2022
Resolved
Electrical equipment exposed to the weather must be watertight. Mast rise above the pilot house is allowing water ingress due to electrical wiring penetration through holed mast rise and it is not watertight and does not have a watertight conduit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 14 July 2022
Resolution: Hole sealed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 July 2022
Resolved
A weathertight door must be provided for each opening located in a deck house. Port and stbd doors are delaminating at the ends, not properly hinged, not gasketed and no door handles for access. Also provide cover for deck chain storage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 20 July 2022
Resolution: Both doors rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2022
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy has hole and foam is exposed. Replace life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: Replaced with a new ring buoy.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 July 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Midship bilge alarm light is not operational.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: New alarm installed and tested satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 May 2021
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. The vessel did not conduct a dry dock inspection before the vessel's anniversary date. The vessel needs to conduct a credited dry dock.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2021
Resolution: Vessel conducted a credited dry dock.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 August 2017
Resolved
Vessel needs to configure its bilge pumps and bilge high level alarm in two independent systems separate of each other.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 2 September 2017
Resolution: The vessel configured its bilge pumps and high level alarms into two independent systems.
Communications › Radio Communications › EPIRB
Issued 2 August 2017
Resolved
Vessel needs to install a new hydrostatic release unit for its EPIRB.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 2 September 2017
Resolution: A new hydrostatic release was installed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 August 2017
Resolved
Vessel needs to have its full FCC Safety Certificate renewed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 2 September 2017
Resolution: The company renewed the vessel's FCC Safety Certificate.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 2 August 2017
Resolved
Vessel needs to incorporate in-water emergency procedures to the vessels instruction list.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 2 September 2017
Resolution: The company has revised and posted the vessel's instruction list to include in-water emergency procedures.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 21 November 2016
Resolved
Vessel’s pre-engineered fire extinguishing unit needs to be in working order.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2016
Resolved 30 November 2016
Resolution: The vessel's pre-engineered fire extinguishing unit is in working order.
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 November 2016
Resolved
Vessel needs to conduct satisfactory sea trials and perform the required drills.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2016
Resolved 30 November 2016
Resolution: The vessel conducted satisfactory fire and abandonship drills.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 21 November 2016
Resolved
Vessel fuel strainers need to be equipped with proper flame protection.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2016
Resolved 30 November 2016
Resolution: The vessel outfitted proper flame protection under the fuel strainers.
Documentation › Certificates/Documents › Permit, Other
Issued 21 November 2016
Resolved
Vessel operator needs to provide proof of valid radio operator permit.
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 21 December 2016
Resolution: The vessel operator provided proof of a valid FCC Radio Operator Permit.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 November 2016
Resolved
Vessel needs to have an approved Class D VHF radio installed onboard the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 21 December 2016
Resolution: The vessel has been outfitted with a working Class D Radio.