Inspection history · 52
1 April 2026
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8338853
8 December 2025
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8279733
6 November 2025
Examination of Repairs · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8265289
11 September 2025
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8229414
12 June 2025
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8160415
11 December 2024
In-Service Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8041964
29 August 2024
Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7992284
22 April 2024
Re-Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7897710
10 January 2024
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7833789
25 October 2023
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7813802
11 September 2023
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7789607
26 July 2023
Re-Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7751971
11 January 2023
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7613028
3 October 2022
Administrative Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7566184
13 September 2022
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7566919
24 August 2022
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7536068
14 April 2022
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7430270
21 March 2022
Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7415734
5 January 2022
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7373064
23 December 2021
Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7371973
8 September 2021
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7306456
20 July 2021
Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7260756
6 June 2021
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7217391
5 April 2021
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7169052
6 January 2021
COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7116932
2 November 2020
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7086985
23 July 2020
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7011142
5 May 2020
In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6957841
6 April 2020
Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6935958
15 January 2020
COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6885858
21 October 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6837140
1 August 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6768398
22 May 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6690732
7 January 2019
MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6606535
17 October 2018
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6563261
11 May 2018
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6412089
7 February 2018
MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6326630
22 January 2018
Internal Structural Exam · Hull Examination · Plan Review (Other than "T")
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6341983
18 January 2018
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6339526
3 January 2018
Drydock Extension
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6332210
23 October 2017
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6293909
11 September 2017
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6264404
9 August 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6282633
30 May 2017
Re-Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6163321
24 February 2017
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6094260
24 February 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6111195
25 January 2017
MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6073349
14 October 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6022291
15 June 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5907454
4 March 2016
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5828609
17 February 2016
MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5816836
7 January 2016
Drydock Extension
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5793110
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 8 December 2025
Resolved
WTD #1 Bell does not annunciate. Repair/replace the bell to activate during closing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2026
Resolved 14 January 2026
Resolution: Bell repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2025
Resolved
Loose electrical wires in the generator room toward engine room watertight door. Remove or secure the wires in an enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2026
Resolved 14 January 2026
Resolution: Loose wires repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 December 2025
Resolved
Top air receiver in the engine room gauge inaccurate. Replace with a calibrated gauge
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2026
Resolved 14 January 2026
Resolution: New gauge installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2025
Resolved
Locate and repair ground on the G-1 panel in the galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2026
Resolved 9 January 2026
Resolution: Ground identified in an extertior light. The light was replaced and the ground was eliminated.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 November 2025
Resolved
Clean bilge in fwd shaft space.
Action required: 705 - Other - as specified
Resolved 1 December 2025
Resolution: Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 December 2024
Resolved
Each hatch exposed to the weather must be watertight. Bow thruster access hatch is not water tight. Make necessary repairs to make access hatch watertight. 46CFR171.124
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 28 May 2025
Resolution: Hatch is watertight, all sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 December 2024
Resolved
Number #2 water tight door is leaking hydraulic fluid from the ram. Repair or replace hydraulic ram and prove operation. 46CFR170.270
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 28 May 2025
Resolution: All sat
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 April 2024
Resolved
Prove proper operation of fire damper on stbd side 01 deck and label.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 29 August 2024
Resolution: completed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2024
Resolved
Provide junction box cover in galley overhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 29 August 2024
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 April 2024
Resolved
Prove proper operation of FSD's on stbd side 01 deck (lounge and lift deck access).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 29 August 2024
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 July 2023
Resolved
Fire Screen Doors (FSD) shall self close. Following doors were observed to NOT close:
FSD #5, aft port car deck
FSD stbd side main deck
Adjust to close.
46 CFR 72.05-25(b)(9)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2023
Resolved 29 August 2023
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 January 2022
Resolved
Prove proper operation of CO2 for engine/generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2022
Resolution: Witnessed via FaceTime and operational test of the CO2 system
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 5 January 2022
Resolved
Crop/Renew frames/gussets in bulkhead under hatchin the port aft void space. (Void fwd of lazarette on port side)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 31 March 2022
Resolution: frames replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 January 2022
Resolved
Correct ground on 1G 220 panel in way of deli galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 26 April 2022
Resolution: Completed on quarterly
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 20 July 2021
Resolved
Lagging around main engine exhaust trunks located on the main car deck do not block enough heat. Temperatures of the lagging surface were recorded at 200 degrees with a laser thermometer. Additional lagging is required to reduce surface temperatures to less than 150 degrees.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2021
Resolution: Additional lagging has been added to the exhaust trunk
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 January 2020
Resolved
Renew rescue boat fall.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2020
Resolved 5 May 2020
Resolution: New falls and rescue boat installed. All systems tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2019
Resolved
Prove proper operation of aux boiler high temperature alarm. The shutdown operates, however the alarm does not.
Action required: 10 - Deficiency Rectified
Due 16 January 2019
Resolved 16 January 2019
Resolution: Vessel crew replaced relay that was assosicated with the high temp alarm and was corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 January 2019
Resolved
Prove proper operation of P&S M/E expansion tank low level murphy switch. The switches are frozen in the up position.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2019
Resolved 6 February 2019
Resolution: New murphy switches installed. Tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2019
Resolved
Prove proper operation of the #1 generator low lube oil alarm sender.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 January 2019
Resolved 6 February 2019
Resolution: #1 generator low lube oil alarm tested sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 February 2018
Resolved
Replace cracked light fixture junction boxes on sun deck
Due 28 February 2018
Resolved 14 February 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 February 2018
Resolved
Service hoses for bow thruster CO2 system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2018
Construction/Loadline › Structures › Manhole
Issued 7 February 2018
Resolved
Repair weld around newly installed hatch leading to shaft alley from car deck
Due 28 February 2018
Resolved 14 February 2018
Construction/Loadline › Structures › Door
Issued 7 February 2018
Resolved
Repair/remove water tight door manual open alarm bell
Due 28 February 2018
Resolved 14 February 2018
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 February 2018
Resolved
Repair cracked life jacket locker lid, sun deck aft starboard side
Due 28 February 2018
Resolved 14 February 2018
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 February 2018
Resolved
Repair lifejacket locker lid hinges aft port and stbd forward
Due 28 February 2018
Resolved 14 February 2018
Lifesaving › Inflatable Buoyant Apparatus › Serviceable
Issued 2 June 2017
Resolved
#1 IBA case was fractured and contained a hole.
Due 6 June 2017
Resolved 11 September 2017
Fire Fighting › Structural - A Class Divisions › Doors
Issued 2 June 2017
Resolved
Renew damaged gaskets on fire doors # 1,2,4,and 5
Due 30 June 2017
Resolved 11 September 2017
Fire Fighting › Structural - A Class Divisions › Doors
Issued 2 June 2017
Resolved
Replace fire door #1 at next dry dock
Action required: 705 - Other - as specified
Resolved 26 February 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 2 June 2017
Resolved
Provide CO2 warning placards for CO2 protected spaces.
Due 30 June 2017
Resolved 6 June 2017
Resolution: Signs installed.
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 25 January 2017
Resolved
#2 generator reverse power relay did not function under load.
Due 25 March 2017
Resolved 2 June 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 25 January 2017
Resolved
Major exhaust leak was located on the top of the port main engine.
Due 25 March 2017
Resolved 24 February 2017
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 January 2017
Resolved
Not all E lights in the engine room were labled.
Due 25 February 2017
Resolved 24 February 2017
Construction/Loadline › Structures › Manhole
Issued 25 January 2017
Resolved
Hatch to shaft alley/CO2 space on car deck is waisted and needs to be replaced. To be renewed at next yard period.
Due 10 January 2018
Resolved 11 September 2017
Engineering › Bilge Water Management System › Strainer
Issued 25 January 2017
Resolved
Repair engine room bilge strainer.
Due 25 February 2017
Resolved 24 February 2017
Engineering › Bilge Water Management System › Strainer
Issued 25 January 2017
Resolved
Remove strainer and test bilge suction in the tool room.
Due 25 February 2017
Resolved 24 February 2017
Engineering › Fuel Oil Service System › Gauge
Issued 25 January 2017
Resolved
Replace/repair fuel level indicator on day tank.
Due 25 February 2017
Resolved 24 February 2017
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 January 2017
Resolved
Label e-lights on middle car deck.
Due 25 February 2017
Resolved 24 February 2017
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 25 January 2017
Resolved
Package boiler relief valve did not operate.
Due 27 February 2017
Resolved 24 February 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 17 February 2016
Resolved
Provide proper operation of closure of fire ducts for e-generator room
Due 31 March 2016
Resolved 23 March 2016
Operations/Management › Vessel Activity › Other
Issued 17 February 2016
Resolved
Repair all door latches through out the vessel
Due 30 April 2016
Resolved 15 June 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 17 February 2016
Resolved
Repair pressure switch that controls the blower shut down located in the bow thruster space
Due 31 March 2016
Resolved 18 March 2016
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 17 February 2016
Resolved
Clean commpressor on beverage cooler
Due 31 March 2016
Resolved 18 March 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 February 2016
Resolved
Repair/replace emergency exit signs located in the woman's restroom, lounge area, bar pass thorough, stbd outside stairwell (both sides) and port aft stairwell to car deck (top and bottom)
Due 30 April 2016
Resolved 15 June 2016