MAURY USCG vessel records
← All vessels

HIGHLINER

HIGHLINER is a 1973 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 2016, most recently in June 2019, along with 5 deficiencies.

Records from 2016 to 2019. Most recent: inspection, 26 June 2019.

Built
1973
Last inspected
26 June 2019
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 June 2019
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK3529
Flag
UNITED STATES
Maury page id
psix-47554

Documentation record

Registered dimensions (L × B × D)39.7 ft × 14.3 ft × 6.1 ft
Registered tonnagegross 26 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTACOMA WA, UNITED STATES · built 1973
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

26 June 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6680351
25 February 2019 Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6634818
26 June 2018 Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6419813
4 April 2018 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6374570
6 April 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6104200
14 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5830924
18 March 2016 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5828422

Deficiency record · 5

Operations/Management › Equipment Service/Testing › EPIRB
Issued 6 April 2017 Resolved
Provide serviceable hydrostatic release unit for EPIRB to ensure that it can automatically float free and activate. Vessel is restricted to operating within 3NM. 46CFR180.64 / 46CFR185.740
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 April 2017
Resolution: Operator installed new hydrostatic release unit with expiration date of MAY2019.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 14 April 2016 Resolved
Expired batteries on (2)Life floats and (1)Life ring
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 22 April 2016
Resolution: Def cleared
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2016 Resolved
Medicine Cabinet is Missing Iodine
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 22 April 2016
Resolution: Def cleared
Construction/Loadline › Hull › Hull Plating
Issued 18 March 2016 Resolved
Clad weld pitted wastage in lazarette bottom plating, as marked.
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 23 March 2016
Construction/Loadline › Hull › Hull Plating
Issued 18 March 2016 Resolved
Repair hole drilled through transom below wind/waterline zone.
Due 18 April 2016
Resolved 23 March 2016

Ownership record