← All vessels
BRANT POINT
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named BRANT POINT
BRANT POINT is a 1973 passenger vessel (inspected). The Coast Guard has recorded 100 inspections since 1984, most recently in January 2026, along with 131 deficiencies — 4 with no resolution recorded — and 3 casualty investigations between 2009 and 2017.
Records from 1984 to 2026. Most recent: inspection, 13 January 2026.
- Built
- 1973
- Last inspected
- 13 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 100
- Deficiencies
- 131 recorded · 4 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2009–2017
Identity
548820
WDI8858
47557
Flag
UNITED STATES
367742840
Maury page id
psix-47557
Inspections, by type
…with no type recorded12
…past their stated due date4
Years with a record
42 calendar years (1984–2026)
The 100 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)112.4 ft × 27.0 ft × 6.9 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI8858MMSI 367742840 · active · compulsorily equipped · granted 1 May 2026, expires 23 June 2036
WYS2397MMSI 367320410 · expired · compulsorily equipped · granted 31 October 2007, cancelled 13 January 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 100
13 January 2026
Vessel Attendance · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8295882
2 October 2025
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8229697
4 November 2024
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8036803
1 October 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8000489
8 January 2024
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7844895
4 October 2023
Annual Inspection · Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7785856
27 April 2023
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7676617
12 January 2023
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7620786
4 October 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7566346
8 February 2022
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7386793
16 September 2021
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7311850
6 July 2021
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7231828
29 September 2020
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7066795
20 April 2020
Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6943438
22 November 2019
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6857916
15 October 2019
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6834417
18 September 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6536918
13 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6539452
4 July 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6467486
20 June 2018
Security Breach
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6450598
22 May 2018
Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6420230
10 May 2018
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6416730
4 May 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6408039
13 April 2018
Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6391030
10 April 2018
Inclining Experiment · Deadweight Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6390276
17 October 2017
Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6285423
11 October 2017
Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6284854
6 October 2017
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6282816
6 October 2017
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6285758
26 January 2017
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6077519
27 June 2016
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5921231
16 May 2016
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5878894
11 August 2015
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5213621
11 August 2015
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5213875
8 May 2014
MARPOL Annex V Examination · Deficiency Check · COI Inspection · DAPI Audit · MARPOL Annex IV Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4854023
24 May 2012
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4320062
6 September 2011
Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4137135
5 August 2011
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4110424
15 March 2010
Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3690457
17 March 2009
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3434854
16 May 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3194985
12 March 2008
Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3154503
16 May 2007
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2921543
20 April 2006
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2630077
9 March 2006
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2599250
29 July 2005
MTSA Verification
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2443746
14 April 2005
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2331222
8 September 2004
MTSA Verification
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2192253
12 April 2004
Deficiency Check · COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2042113
14 January 2004
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1984233
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978107
3 June 2003
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1807926
6 November 2002
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1701132
8 February 2002
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 1488373
3 December 2001
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1448379
28 November 2001
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1467812
5 November 2001
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1408869
1 July 2001
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 171217
30 May 2001
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1070550
31 October 2000
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1445693
3 April 2000
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1386784
3 November 1999
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1458687
5 November 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1472741
24 April 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1123891
3 April 1998
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 791141
9 August 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 11322
22 April 1997
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1107877
19 November 1996
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1180655
20 February 1996
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 882021
20 November 1995
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1183315
25 May 1995
COI Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 873915
17 February 1995
Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1450950
25 May 1994
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1392021
14 February 1994
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 856431
26 May 1993
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1438070
24 March 1993
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1420722
8 March 1993
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1148073
19 June 1992
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 960551
24 May 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 26229
21 May 1992
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 950402
19 May 1992
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 950398
6 March 1992
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1263907
10 July 1991
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 934413
11 June 1991
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 931082
29 January 1991
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 905263
9 May 1990
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1228171
4 January 1990
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1236415
18 May 1989
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1040590
8 February 1989
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1340543
20 May 1988
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1196382
25 February 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336187
11 May 1987
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1024724
20 January 1987
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1008785
21 May 1986
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1299060
6 January 1986
Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1305900
3 May 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1290060
4 March 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 977922
21 December 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1284747
13 December 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 976185
19 October 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1282280
Deficiency record · 131
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 January 2026
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Fuel Tank Space: Aft bracket for green pump in space has significant corrosion. Crop and replace horizontal and diagonal bracket sections.
46 CFR 115.830(a)
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 January 2026
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Fuel Tank Space: Top longitudinal support frame for ladder well has significant corrosion. Crop and renew frame.
46 CFR 115.830(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 January 2026
No resolution recorded
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Bow plexi-glass window cracked and requires replacement.
46 CFR 116.1020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 January 2026
No resolution recorded
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Upper Deck: Starboard fwd sliding door frame corroded. Crop and renew inboard side.
46 CFR 115.830(a)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. An exhaust leak in the steering gear space created an unsafe condition which precluded a visual inspection of the bilge suction, high water alarm, and steering gear.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2025
No resolution recorded
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Electrical cable protective sheathing for the starter on the starboard engine was severely chafed and overhead electrical cables above the engines lacked metal supports with required spacing.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 October 2025
Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Steering gear reservoir in machinery space is leaking hydraulic fluid.
46 CFR 182.30-1(a)
("Old T")
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 October 2025
Resolved
Piping, valves, and fittings in a fire main system must comply with part 119, subpart G of this subchapter. Aft hydrant on second deck near stairwell was leaking water at the stem while energized.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 October 2025
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Bilge suction in all inspected voids was intermittent and sluggish.
46 CFR 182.25-1(a)
("Old T")
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 October 2025
Resolved
Gages to indicate lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Port outboard engine L/O pressure gauge was inoperable.
46 CFR 182.20-5(b)
("Old T")
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 October 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(1) or a kit with equivalent contents and instructions. First aid kit was missing analgesics.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 2 October 2025
Resolved
A passenger accommodation space must not contain any item that could injure a passenger, unless such an item is adequately shielded or isolated. Anchor line scuttle shielding and various bulwark stiffeners are broken or corroded, presenting sharp edges to passengers.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 October 2025
No resolution recorded
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] or alterations that affect the safety of the vessel include, but are not limited to, the: repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of steering, propulsion and power supply systems. Unapproved silicone putty repair was found on both inboard stern tubes in the #5 void. Provide OCMI with report from gauging scheduled December 2025, submit a permanent repair proposal on the basis of said report, and repair prior to next credit drydock.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 October 2024
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matte black inboard screens and meet the requirements of § 84.15…..Vessel does not have matte black inboard screens as required.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 October 2024
Resolved
Sidelights mean a green light on the starboard side and a red light on the port side each showing an unbroken light over an arc of the horizon of 112.5 degrees and so fixed as to show the light from right ahead to 22.5 degrees abaft the beam on its respective side. Stern light cover is broken allowing the attached screen to move, therefore changing the degrees in which the light is visible. Repair or renew port side light to the satisfaction of attending marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 October 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 65 feet in length must also have navigation lights that meet UL 1104. The vessel replaced the lamps in the navigation lights with lamps that are not identified by the manufacture as required in UL 1104. Renew lamps with those identified by the manufacture to be used or provide proof that the replacement LED bulbs have been tested and approved by the manufacture to be used in the fixture and still comply with UL 1104, to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Cables for both sidelights are pulled from the plugs exposing the individual conductors. Additionally, the box connectors at the bottom of the shore power/heater knife switch are no longer attached to the box allowing the cables to rub on the edge of the box. Furthermore, the electrical panel for the top deck snack bar has an open space where a circuit breaker was removed. Make proper repairs to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 October 2024
Resolved
At least one ring buoy must be fitted with a floating water light. Vessel’s only floating water light was inoperable. Repair or renew floating water light that complies with 46 CFR 177.70 (d). VESSEL IS RESTRICTED TO DAYTIME OPERATION UNTIL DEFICIENCY CLEARED BY ATTENDING MARINE INSPECTOR.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2024
Resolved
Nonmetallic piping materials, including nonmetallic flexible hose assemblies, must meet the requirements of 46 CFR 56.60-25 in subchapter F of this chapter. Nonmetallic flexible hose for the inboard starboard main engine’s raw water supply is cracking. Renew nonmetallic flexible hose to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2024
Resolved
All electrical equipment and circuits must be clearly marked and identified. 24 VDC Panel in engine room has breaker not properly marked to identify what it feeds.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Lube oil hose on starboard engine was laying across engine block and obtained heat damage to the outer sheathing of the hose.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 October 2023
Resolved
Where fire extinguishing systems or equipment are installed but not required, the equipment and its installations are subject to 46 CFR 181. Provisions shall be made by means of plugs, covers, etc to prevent the admission of air into engine room in case of fire. Vessel port and starboard engine room ventilation louvers were deteriorated and not closing properly. O/O is to develop a repair plan and submit to OCMI for review then effect permanent repairs prior to carriage of passengers and prior to receiving hull credit at dry dock.
46 CFR 181.05-5
46 CFR 181.20-35
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 October 2023
Resolved
A sufficient number of emergency lights should be installed throughout the machinery spaces to permit the performance of essential operations and observations under emergency conditions and to facilitate restoration of services. Vessel did not have any emergency lighting the vicinity of the main/emergency switchboard. O/O is to install emergency lighting adequate to facilitate restoration of electrical power to the vessel under emergency conditions.
46CFR112.15-1(c)
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 January 2023
Resolved
C/R keel where wasted beyond 25% to good metal.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 January 2023
Resolved
C/R port side aft box keel where wasted beyond 25% to good metal.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 January 2023
Resolved
C/R stbd side aft box keel where wasted through to good metal as discussed with vessel rep.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 12 January 2023
Resolved
C/R horizontal keel box frames #1-#4 from aft E/R bulkhead where wasted/holed through to good metal.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 April 2022
Resolved
Repair wasted/holed frame on stbd aft freight door.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2022
Resolved
Renew port and stbd propulsion shafts at next credit drydock as per repair plan dtd 04Mar22.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 July 2021
Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. The forward bilge suction was inoperable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2021
Resolved
All wiring shall be run as high as practicable above bilges. The cable from the port generator was not secured and was laying in the bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 July 2021
Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. The oil pressure indicator for the port engine was inoperable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2021
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. A portable extension cord was used in the galley to run two permanently installed machines.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 29 September 2020
Resolved
Flexible fill pipe sections shall be secured with two clamps of corrosion resistant material. The port side fuel fill line lacks the second clamp on both the top and bottom side of the flexible hose. Install the second clamps on both sides of the hose.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 September 2020
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. The starboard side navigation light is burned out and inoperable.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 September 2020
Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Both the port and starboard batteries are installed with temporary wing nuts.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 29 September 2020
Resolved
The marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. A distribution panel is missing a breaker creating an electrical hazard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2019
Resolved
Each vessel of more than 65 feet in length must have permanent draft marks at each end of the vessel. 46 CFR 122.602 (c)(1). Vessel does not have draft marks. Permanently mark draft marks on vessel during planned drydock JAN2020.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 October 2019
Resolved
A-class bulkheads and decks must be insulated with approved structural insulation. 46 CFR 116.415 (a)(2)(i). Engine room overhead missing portions of insulation above the port engine and starboard battery bank.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018
Resolved
Vsl is broadcasting invalid MMSI, Vsl is broadcasting Invalid Call Sign and Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V)
Stability › Incline Test › General
Issued 10 May 2018
Resolved
Provide proof of valid stability letter.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 7 May 2018
Resolved
The vessel does not have draft marks on each end. Permanently install draft marks on both sides of each end of the vessel at next haul out and no later than 31JAN2020.
Construction/Loadline › Structures › Deck Plating
Issued 13 April 2018
Resolved
Crop & renew punctured hole on the aft portion of the weatherdeck above the lazarette.
Construction/Loadline › Hull › Hull Plating
Issued 30 January 2018
Resolved
Repair two holes in deck of lazarette that resulted from the removal of a drainage pipe.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 11 October 2017
Resolved
Replace E/R insulation to original construction.
Documentation › Markings/Placards › Warning Signs
Issued 11 October 2017
Resolved
Label E/R escape hatch.
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Board
Issued 11 October 2017
Resolved
Prove proper operation of port generator.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 11 October 2017
Resolved
Make shaft runouts and stuffing boxes (all four) available for NDT.
Construction/Loadline › Hull › Bottom Plating
Issued 11 October 2017
Resolved
De-scale port inboard MDE blige pocket aft of port block for close up inspection.
Construction/Loadline › Hull › Hull Plating
Issued 6 October 2017
Resolved
Crop and renew damaged area as marked in #2 void IWO Port Bow to satisfaction of attending Marine Inspector.
Construction/Loadline › Structures › Deck Plating
Issued 15 July 2016
Resolved
Provide repair proposal for hole on deck above #7 void.
Operations/Management › Vessel Safety Management › Designated Person(s)
Issued 15 July 2016
Resolved
No pax access fwd of pilot house, provide aft deck chains.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 15 July 2016
Resolved
Find/mark draft marks on vessel per stability letter. Draft marks to be completed during next scheduled dry-dock.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 July 2016
Resolved
Make permanent repairs to rail coarses on 3rd deck aft.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 11 August 2015
Resolved
Repair inboard port oil drive gear pump and conduct u/w sea trials with Coast Guard Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (air motor)
Issued 11 August 2015
Resolved
troubleshoot root cause of the inboard port MDE. Provide documentation to attending Coast Guard Marine Inspector with diagnoses and plans to rectify MDE.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 8 May 2014
Resolved
MSD tank, repair rust hole in port side of tank prior to passenger ops
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 May 2014
Resolved
Top deck rails, repair or replace snow fence coursings prior to passenger ops
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2014
Resolved
Main deck forward, properly dead end or remove loose wire
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 8 May 2014
Resolved
Anchor line, eight feet of line exposed to elements deteriorated, cut back to good material & re-splice line
Electrical › Electrical Distribution System (service) › Switchboard
Issued 8 May 2014
Resolved
Switchboard, amp meter not functioning, repair and test
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 8 May 2014
Resolved
Buoyant Apparatus, Renew retro reflective material on top 4 floats
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 May 2014
Resolved
02 Deck, Aft, renew line or replace life ring, ensure name of vessel stenciled on ring
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 May 2014
Resolved
Provide current coast pilot & light list
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 May 2014
Resolved
Provide passenger maximum per deck labels for 02 deck and top deck
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 8 May 2014
Resolved
MSD overboard valve, provide securing device on valve handle
Operations/Management › Drills/Instruction › Abandon Ship
Issued 8 May 2014
Resolved
Complete all crew drills within 30 days.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 24 May 2012
Resolved
Conduct all crew & security drills
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 April 2009
Resolved
Install passenger accomodations throughout vessel prior to carrying passengers.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 April 2009
Resolved
Replace inop nav lights prior to getting underway.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 8 April 2009
Resolved
Service life jackets (retro tape) prior to carrying passengers.
Operations/Management › Drills/Instruction › Fire
Issued 8 April 2009
Resolved
Conduct emergency drills (MOB, fire, etc) prior to carrying passengers.
Lifesaving › Lifebuoys › Serviceable
Issued 17 March 2009
Resolved
Replace retro tape on life ring on stbd side of wheelhouse.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 16 May 2008
Resolved
Portable extinguisher located behind snack bar in need of service.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 May 2008
Resolved
Replace plastic rubber waste barrels with non-combustible barrels.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 20 April 2006
Resolved
Replace door on breaker box located on port side of pilot house.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 20 April 2006
Resolved
Renew flame screen on fuel oil tank vents.
Lifesaving › Lifebuoys › Serviceable
Issued 20 April 2006
Resolved
Renew ring life buoy at port-side pilot house, due to color fading.
Communications › Radio Communications › EPIRB
Issued 20 April 2006
Resolved
Replace EPIRB hydrostatic release unit prior to July 01, 2006.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 20 April 2006
Resolved
Label fire damper to engine room in way of pax. head.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 14 April 2005
Resolved
PROVIDE B-II FIRE EXTINGUISHER FOR ENGINEROOM ACCESS.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 April 2005
Resolved
CONDUCT UNDERWAY DRILLS AND OPERATIONS.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 14 April 2005
Resolved
PROVIDE OIL POLLUTION PLACARD.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 14 April 2005
Resolved
PROVIDE CREW STATION BILL AS REQUIRED BY 46 CFR 122.514.
Operations/Management › Log/Records
Issued 12 April 2004
Resolved
PROVIDE A LOG FOR LIFESAVING EQUIPMENT TESTING, INSPECTIONS AND DRILLS.
Communications › Radio Communications
Issued 12 April 2004
Resolved
REPLACE EPIRB HYDROSTATIC RELEASE. LEGACY COMPONENT DESC: EPIRB
Operations/Management › Drills/Instruction
Issued 6 November 2002
Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS. LEGACY COMPONENT DESC: Man Overboard Recovery
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 6 November 2002
Resolved
CONDUCT UNDERWAY TESTING OF ALL MACHINERY AND AUXILLARY SYSTEMS.
Accommodation/Occupational Safety › Ventilation
Issued 6 November 2002
Resolved
LABEL ALL VENTILATION SHUTDOWNS.
Lifesaving › Buoyant Apparatus
Issued 6 November 2002
Resolved
REMOVE BUNGEE CORD TIE DOWNS FROM ALL B/A's AND INSTALL A RELEASE SYSTEM.
Engineering › Fuel Oil Storage/Transfer System
Issued 6 November 2002
Resolved
INSTALL EMERGENCY SHUT OFF FOR THE FUEL LINE FOR THE BOW THRUSTER. VALVE MUST BE LOCATED OUTSIDE THE SPACE WITH THE VALVE. LEGACY COMPONENT DESC: Valve
Communications › Radio Communications
Issued 6 November 2002
Resolved
REPLACE EPIRB HYDROSTATIC RELEASE. LEGACY COMPONENT DESC: EPIRB
Construction/Loadline › Hull
Issued 3 December 2001
Resolved
Crop and renew main longitudinal frames on port and stbd outboard of inboard main diesel engine transmission supports. LEGACY COMPONENT DESC: Longitudinal Frame
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 December 2001
Resolved
Replace missing lagging on dry exhaust. LEGACY COMPONENT DESC: Exhaust Lagging
Construction/Loadline › Hull
Issued 3 December 2001
Resolved
Crop and renew main transverse frames on port and stbd outboard of inboard main diesel engine transmission supports. LEGACY COMPONENT DESC: Transverse Frame
Construction/Loadline › Hull
Issued 3 December 2001
Resolved
Crop and renew main longitudinal frames under exhausts where 80-100% wastage and hydrostatically buckled at lower 1-2" against hull. LEGACY COMPONENT DESC: Longitudinal Frame
Construction/Loadline › Hull
Issued 3 December 2001
Resolved
Crop and renew framing, decking, and side shell stiffeners in way of engineroom escape hatch. LEGACY COMPONENT DESC: Stiffener
Construction/Loadline › Structures
Issued 3 December 2001
Resolved
Provide means of opening engine room escape hatch from engine room. LEGACY COMPONENT DESC: Machinery Space Opening
Fire Fighting › Structural - A Class Divisions
Issued 3 December 2001
Resolved
Renew door latch to engine room fire door. Note that replacement latch must have a 3/4 throw bolt. LEGACY COMPONENT DESC: Openings - Fire Doors
Fire Fighting › Structural - A Class Divisions
Issued 3 December 2001
Resolved
Reinstall structural fire protection where missing/removed in engine room overhead. LEGACY COMPONENT DESC: Decks - Machinery Spaces
Electrical › Electrical Distribution System (service)
Issued 3 December 2001
Resolved
Remove deadended wiring and properly re-splice wiring above stbd main diesel engine. LEGACY COMPONENT DESC: Wiring
Electrical › Electrical Distribution System (service)
Issued 3 December 2001
Resolved
Repair junction box above wire tray at stbd main diesel engine. LEGACY COMPONENT DESC: Junction Box
Electrical › Electrical Distribution System (service)
Issued 3 December 2001
Resolved
Remove dead-ended wiring above stbd exhaust. LEGACY COMPONENT DESC: Wiring
Documentation › Certificates/Documents
Issued 3 December 2001
Resolved
Vessel COI is deactivated/revoked. In order to regain Certification all required repairs must be made at drydock with USCG Marine Inspectors in attendance. LEGACY COMPONENT DESC: Certificate of Inspection
Construction/Loadline › Hull
Issued 3 December 2001
Resolved
Crop and renew deep web frame on side shell on stbd side above previous repair. LEGACY COMPONENT DESC: Transverse Frame
Construction/Loadline › Hull
Issued 3 December 2001
Resolved
Crop and renew deck in way of ladder behind main deck bar and lower bulkhead in same area. LEGACY COMPONENT DESC: Deck Plating
Construction/Loadline › Hull
Issued 3 December 2001
Resolved
Remove plastic bags filled with fiberglass insulation from and renew framing and deck as needed around all engine room vents. LEGACY COMPONENT DESC: Engine room ventilation penetrations - deck& framing
Lifesaving
Issued 5 November 2001
Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS AT THE START OF THE SPRING OPERATING SEASON.
Lifesaving
Issued 24 April 1998
Resolved
Unknown Component - Unknown Cause/Condition
Construction/Loadline
Issued 20 November 1995
Resolved
RENEW FOREPEAK BILGE STRAINER PRIOR TO NEXT OPERATING SEASON.
Navigation
Issued 20 November 1995
Resolved
TIGHTEN/ADJUST STARBOARD RUDDER POST ARM PRIOR TO NEXT OPERATING SEASON.
Construction/Loadline
Issued 20 November 1995
Resolved
PROVIDE GUARD FOR ELECTRIC BILGE PUMP SHAFT PRIOR TO NEXT OPERATING SEASON.
Lifesaving
Issued 20 November 1995
Resolved
CONDUCT UNDERWAY DRILLS PRIOR TO NEXT OPERATING SEASON.
Construction/Loadline
Issued 20 November 1995
Resolved
CROP TO GOOD METAL AND RENEW, SIDE SHELL LONGS AT AFT ENGINEROOM BULKHEAD INWAY OF MDE EXHAUST PORT AND STARBOARD SIDE PIOR TO NEXT OPERATING SEASON.
Lifesaving
Issued 25 May 1995
Resolved
CONDUCT UNDERWAY FIRE AND BOAT DRILLS NOT LATER THAN 12JUN95.
Engineering
Issued 25 May 1995
Resolved
RE-ROUTE PVC BREATHER LINE ON THE PORT MAIN ENGINE.
Accommodation/Occupational Safety
Issued 25 May 1995
Resolved
LABEL MEANS OF ESCAPE FROM THE ENGINE ROOM.
Fire Fighting
Issued 25 May 1995
Resolved
INSTALL A PRESSURE GAUGE FOR VESSEL'S ELECTRIC FIRE PUMP.
Construction/Loadline
Issued 25 May 1995
Resolved
FREE UP FOZEN REACH ROD TO FOREPEAK BILGE VALVBE.
Construction/Loadline
Issued 25 May 1995
Resolved
PLUG PENETRATIONS IN FORWARD ENGINE AND AFT FUEL SPACE BULKHEADS.
Lifesaving
Issued 19 May 1992
Resolved
Conduct fire and boat drill in presence of a CG marine inspector.
Electrical
Issued 19 May 1992
Resolved
Secure power cable properly.
Navigation
Issued 19 May 1992
Resolved
Make all speakers in the P.A. system operational prior to carrying passengers.
Electrical
Issued 19 May 1992
Resolved
Make emergency lighting operational in the engineroom prior to carrying passengers.
Electrical
Issued 19 May 1992
Resolved
Provide a belt guard for the port generator.
Construction/Loadline
Issued 25 February 1988
Resolved
4) C&R BOTTOM PLATING NEAR FRONT OF OUTBOARD STBD KEEL COOLER WHERE WALTED 5) C&R BOTTOM PLATING NEAR FORWARD PART OF INBOARD STBD KEEL COOLER WHERE WASTED 6) C&R BOTTOM PLATING IN BTWN AFT END OF KEEL COOLERS STBD SIDE WHOLE WASTD
Construction/Loadline
Issued 25 February 1988
Resolved
7) C&R BOTTOM PLATING AT END OUTBOARD STERN TUBE PORT SIDE WHERE WASTED 8) C&R BOTTOM PLATING FWD PART IN WAY OF KEEL COOLER PORTSIDE WHERE WASTED
Construction/Loadline
Issued 25 February 1988
Resolved
1) C&R AREAS IN AFT BULKHEAD WHERE WASTED 2) C&R BOTTOM PLATING OUTBOARD OF STBD OUTBOARD SHAFT WHERE WASTED 3) C&R BOTTOM PLATING MIDWAY OF KEEL COOLER AT TURN OF BILGE WHERE WASTED STBD SIDE BOTTOM SECTION OF E/R BULKHEAD.
Navigation
Issued 13 December 1984
Resolved
REPAIR PIVOT PIN ON STARBOARD RAM WHERE IT ATTACHES TO HOLDING BAR.
Electrical
Issued 13 December 1984
Resolved
REPAIR COUPLING ON ELECTRIC BILGE PUMP.
Unknown
Issued 13 December 1984
Resolved
REPLACE MSD HOLDING TANK.
Casualty record · 3
17 September 2009Routine · role: Involved in a Marine Casualty · activity 3607473
5 August 2011Routine · role: Involved in a Marine Casualty · activity 4110424
6 October 2017Routine · role: Involved in a Marine Casualty · activity 6285758
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.