MAURY USCG vessel records
← All vessels

BRANT POINT

BRANT POINT is a 1973 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2016, most recently in January 2026, along with 54 deficiencies — 4 with no resolution recorded — and 3 casualty investigations between 2009 and 2017.

Records from 2009 to 2026. Most recent: inspection, 13 January 2026.

Built
1973
Last inspected
13 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 January 2026
…with no type recorded2
…past their stated due date4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI8858
Flag
UNITED STATES
Maury page id
psix-47557

Documentation record

Registered dimensions (L × B × D)112.4 ft × 27.0 ft × 6.9 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

13 January 2026 Vessel Attendance · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8295882
2 October 2025 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8229697
4 November 2024 Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8036803
1 October 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8000489
8 January 2024 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7844895
4 October 2023 Annual Inspection · Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7785856
27 April 2023 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7676617
12 January 2023 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7620786
4 October 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7566346
8 February 2022 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7386793
16 September 2021 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7311850
6 July 2021 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7231828
29 September 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7066795
20 April 2020 Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6943438
22 November 2019 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6857916
15 October 2019 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6834417
18 September 2018 In-Service Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6536918
13 September 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6539452
4 July 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6467486
20 June 2018 Security Breach
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6450598
22 May 2018 Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6420230
10 May 2018 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6416730
4 May 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6408039
13 April 2018 Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6391030
10 April 2018 Inclining Experiment · Deadweight Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6390276
17 October 2017 Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6285423
11 October 2017 Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6284854
6 October 2017 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6282816
6 October 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6285758
26 January 2017 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6077519
27 June 2016 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5921231
16 May 2016 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5878894

Deficiency record · 54

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 January 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Fuel Tank Space: Aft bracket for green pump in space has significant corrosion. Crop and replace horizontal and diagonal bracket sections. 46 CFR 115.830(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2026
Resolved 18 June 2026
Resolution: Bracket replaced
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 January 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Fuel Tank Space: Top longitudinal support frame for ladder well has significant corrosion. Crop and renew frame. 46 CFR 115.830(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2026
Resolved 18 June 2026
Resolution: Ladder support longitudinal renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 January 2026 No resolution recorded
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Bow plexi-glass window cracked and requires replacement. 46 CFR 116.1020
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 January 2026 No resolution recorded
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Upper Deck: Starboard fwd sliding door frame corroded. Crop and renew inboard side. 46 CFR 115.830(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2026 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. An exhaust leak in the steering gear space created an unsafe condition which precluded a visual inspection of the bilge suction, high water alarm, and steering gear.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2026
Resolution: Exhaust leak fixed. Tested steering, high water alarm, and bilge suction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2025 No resolution recorded
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Electrical cable protective sheathing for the starter on the starboard engine was severely chafed and overhead electrical cables above the engines lacked metal supports with required spacing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 October 2025 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Steering gear reservoir in machinery space is leaking hydraulic fluid. 46 CFR 182.30-1(a) ("Old T")
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 18 June 2026
Resolution: Leak repaired; new gasket installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 October 2025 Resolved
Piping, valves, and fittings in a fire main system must comply with part 119, subpart G of this subchapter. Aft hydrant on second deck near stairwell was leaking water at the stem while energized.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 23 October 2025
Resolution: Stem was tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 October 2025 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Bilge suction in all inspected voids was intermittent and sluggish. 46 CFR 182.25-1(a) ("Old T")
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 18 June 2026
Resolution: Tested bilge suction in steering gear compartment. Suction satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 October 2025 Resolved
Gages to indicate lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Port outboard engine L/O pressure gauge was inoperable. 46 CFR 182.20-5(b) ("Old T")
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 18 June 2026
Resolution: L/O pressure gauge renewed and tested.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 October 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(1) or a kit with equivalent contents and instructions. First aid kit was missing analgesics.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 23 October 2025
Resolution: Analgesics were provided.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 2 October 2025 Resolved
A passenger accommodation space must not contain any item that could injure a passenger, unless such an item is adequately shielded or isolated. Anchor line scuttle shielding and various bulwark stiffeners are broken or corroded, presenting sharp edges to passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 18 June 2026
Resolution: Renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 October 2025 No resolution recorded
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] or alterations that affect the safety of the vessel include, but are not limited to, the: repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of steering, propulsion and power supply systems. Unapproved silicone putty repair was found on both inboard stern tubes in the #5 void. Provide OCMI with report from gauging scheduled December 2025, submit a permanent repair proposal on the basis of said report, and repair prior to next credit drydock.
Action required: 705 - Other - as specified
Due 31 January 2026 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 October 2024 Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matte black inboard screens and meet the requirements of § 84.15…..Vessel does not have matte black inboard screens as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2024
Resolved 17 October 2024
Resolution: Matte black screens in place.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 October 2024 Resolved
Sidelights mean a green light on the starboard side and a red light on the port side each showing an unbroken light over an arc of the horizon of 112.5 degrees and so fixed as to show the light from right ahead to 22.5 degrees abaft the beam on its respective side. Stern light cover is broken allowing the attached screen to move, therefore changing the degrees in which the light is visible. Repair or renew port side light to the satisfaction of attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2024
Resolved 29 October 2024
Resolution: Conducted deficiency check and confirmed proper mounting of stern light and stern light housing direction.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 October 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 65 feet in length must also have navigation lights that meet UL 1104. The vessel replaced the lamps in the navigation lights with lamps that are not identified by the manufacture as required in UL 1104. Renew lamps with those identified by the manufacture to be used or provide proof that the replacement LED bulbs have been tested and approved by the manufacture to be used in the fixture and still comply with UL 1104, to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2024
Resolved 17 October 2024
Resolution: UL approved bulbs in place for navigation lights.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Cables for both sidelights are pulled from the plugs exposing the individual conductors. Additionally, the box connectors at the bottom of the shore power/heater knife switch are no longer attached to the box allowing the cables to rub on the edge of the box. Furthermore, the electrical panel for the top deck snack bar has an open space where a circuit breaker was removed. Make proper repairs to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2024
Resolved 17 October 2024
Resolution: All cables are properly housed and protected against chafing. Electrical panel properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 October 2024 Resolved
At least one ring buoy must be fitted with a floating water light. Vessel’s only floating water light was inoperable. Repair or renew floating water light that complies with 46 CFR 177.70 (d). VESSEL IS RESTRICTED TO DAYTIME OPERATION UNTIL DEFICIENCY CLEARED BY ATTENDING MARINE INSPECTOR.
Action required: 705 - Other - as specified
Due 15 October 2024
Resolved 17 October 2024
Resolution: New floating water light in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2024 Resolved
Nonmetallic piping materials, including nonmetallic flexible hose assemblies, must meet the requirements of 46 CFR 56.60-25 in subchapter F of this chapter. Nonmetallic flexible hose for the inboard starboard main engine’s raw water supply is cracking. Renew nonmetallic flexible hose to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2024
Resolved 19 December 2024
Resolution: Nonmetallic flexible hose replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2024 Resolved
All electrical equipment and circuits must be clearly marked and identified. 24 VDC Panel in engine room has breaker not properly marked to identify what it feeds.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2024
Resolved 17 October 2024
Resolution: Electrical panel properly labeled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Lube oil hose on starboard engine was laying across engine block and obtained heat damage to the outer sheathing of the hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2024
Resolved 17 October 2024
Resolution: Lube oil hose is properly secured away from engine block to prevent damage. New lube oil hose in place.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 October 2023 Resolved
Where fire extinguishing systems or equipment are installed but not required, the equipment and its installations are subject to 46 CFR 181. Provisions shall be made by means of plugs, covers, etc to prevent the admission of air into engine room in case of fire. Vessel port and starboard engine room ventilation louvers were deteriorated and not closing properly. O/O is to develop a repair plan and submit to OCMI for review then effect permanent repairs prior to carriage of passengers and prior to receiving hull credit at dry dock. 46 CFR 181.05-5 46 CFR 181.20-35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 February 2024
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 October 2023 Resolved
A sufficient number of emergency lights should be installed throughout the machinery spaces to permit the performance of essential operations and observations under emergency conditions and to facilitate restoration of services. Vessel did not have any emergency lighting the vicinity of the main/emergency switchboard. O/O is to install emergency lighting adequate to facilitate restoration of electrical power to the vessel under emergency conditions. 46CFR112.15-1(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 6 November 2023
Resolution: O/O installed emergency lighting in the vacinity of the emergency switchboard.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 January 2023 Resolved
C/R keel where wasted beyond 25% to good metal.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 January 2023 Resolved
C/R port side aft box keel where wasted beyond 25% to good metal.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 January 2023 Resolved
C/R stbd side aft box keel where wasted through to good metal as discussed with vessel rep.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2023
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 12 January 2023 Resolved
C/R horizontal keel box frames #1-#4 from aft E/R bulkhead where wasted/holed through to good metal.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 April 2022 Resolved
Repair wasted/holed frame on stbd aft freight door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 4 October 2022
Resolution: Repair sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2022 Resolved
Renew port and stbd propulsion shafts at next credit drydock as per repair plan dtd 04Mar22.
Action required: 705 - Other - as specified
Due 31 January 2024
Resolved 19 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 July 2021 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. The forward bilge suction was inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 July 2021
Resolution: Inspected repair, tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2021 Resolved
All wiring shall be run as high as practicable above bilges. The cable from the port generator was not secured and was laying in the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2021
Resolution: Cable secured properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 July 2021 Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. The oil pressure indicator for the port engine was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2021
Resolution: oil pressure indicator for the port engine was installed and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2021 Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. A portable extension cord was used in the galley to run two permanently installed machines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2021
Resolution: Installed outlet with 15 amp breaker and 14 AWG wire.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 29 September 2020 Resolved
Flexible fill pipe sections shall be secured with two clamps of corrosion resistant material. The port side fuel fill line lacks the second clamp on both the top and bottom side of the flexible hose. Install the second clamps on both sides of the hose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 September 2020
Resolved 29 September 2020
Resolution: Operator installed two hose clamps as required.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 September 2020 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. The starboard side navigation light is burned out and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 September 2020
Resolved 29 September 2020
Resolution: Operator installed new navigation light.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 September 2020 Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Both the port and starboard batteries are installed with temporary wing nuts.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 29 September 2020
Resolved 29 September 2020
Resolution: Proper nuts were intalled during inspection.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 29 September 2020 Resolved
The marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. A distribution panel is missing a breaker creating an electrical hazard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 September 2020
Resolved 29 September 2020
Resolution: Blank Cover was installed during inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2019 Resolved
Each vessel of more than 65 feet in length must have permanent draft marks at each end of the vessel. 46 CFR 122.602 (c)(1). Vessel does not have draft marks. Permanently mark draft marks on vessel during planned drydock JAN2020.
Action required: 705 - Other - as specified
Due 15 November 2019
Resolved 13 April 2020
Resolution: Draft marks installed and painted contrasting color.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 October 2019 Resolved
A-class bulkheads and decks must be insulated with approved structural insulation. 46 CFR 116.415 (a)(2)(i). Engine room overhead missing portions of insulation above the port engine and starboard battery bank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 29 October 2019
Resolution: Installed insulation on missing areas.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
Vsl is broadcasting invalid MMSI, Vsl is broadcasting Invalid Call Sign and Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 November 2018
Resolution: While running a query in VIVS, all information had been updated and AIS was broadcasting the proper information.
Stability › Incline Test › General
Issued 10 May 2018 Resolved
Provide proof of valid stability letter.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2018
Resolved 17 May 2018
Resolution: Received stability letter from MSC.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 7 May 2018 Resolved
The vessel does not have draft marks on each end. Permanently install draft marks on both sides of each end of the vessel at next haul out and no later than 31JAN2020.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2020
Resolved 13 April 2020
Resolution: Draft marks installed and painted in contrasting color.
Construction/Loadline › Structures › Deck Plating
Issued 13 April 2018 Resolved
Crop & renew punctured hole on the aft portion of the weatherdeck above the lazarette.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2018
Resolution: Deck inserts all sat.
Construction/Loadline › Hull › Hull Plating
Issued 30 January 2018 Resolved
Repair two holes in deck of lazarette that resulted from the removal of a drainage pipe.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2018
Resolved 2 May 2018
Resolution: Deck repairs completed satisfactory.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 11 October 2017 Resolved
Replace E/R insulation to original construction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 10 May 2018
Resolution: Vessel rep. replaced E/R structural fire protection to original construction.
Documentation › Markings/Placards › Warning Signs
Issued 11 October 2017 Resolved
Label E/R escape hatch.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 11 October 2017
Resolution: Cleared on the spot.
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Board
Issued 11 October 2017 Resolved
Prove proper operation of port generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 2 May 2018
Resolution: Proved proper operation of port genertator.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 11 October 2017 Resolved
Make shaft runouts and stuffing boxes (all four) available for NDT.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 28 November 2017
Resolution: Tailshafts and stuffing boxes were determined to be in satisfactory condition.
Construction/Loadline › Hull › Bottom Plating
Issued 11 October 2017 Resolved
De-scale port inboard MDE blige pocket aft of port block for close up inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 November 2017
Resolved 28 November 2017
Resolution: Area was descaled and made available for further inspection.
Construction/Loadline › Hull › Hull Plating
Issued 6 October 2017 Resolved
Crop and renew damaged area as marked in #2 void IWO Port Bow to satisfaction of attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2017
Resolution: Insert tested satisfactory.
Construction/Loadline › Structures › Deck Plating
Issued 15 July 2016 Resolved
Provide repair proposal for hole on deck above #7 void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 1 August 2016
Operations/Management › Vessel Safety Management › Designated Person(s)
Issued 15 July 2016 Resolved
No pax access fwd of pilot house, provide aft deck chains.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 July 2016
Resolution: Sign installed. Corrected on the spot.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 15 July 2016 Resolved
Find/mark draft marks on vessel per stability letter. Draft marks to be completed during next scheduled dry-dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 7 May 2018
Resolution: Reissued with new compliance date.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 July 2016 Resolved
Make permanent repairs to rail coarses on 3rd deck aft.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: Stainless steel clamps installed.

Casualty record · 3

17 September 2009Routine · role: Involved in a Marine Casualty · activity 3607473
5 August 2011Routine · role: Involved in a Marine Casualty · activity 4110424
6 October 2017Routine · role: Involved in a Marine Casualty · activity 6285758
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.