Records from 2016 to 2026. Most recent: inspection, 20 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)64.9 ft × 21.0 ft × 10.0 ft
Registered tonnagegross 91 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPERFORMANCE MARINE · ARUNDEL, ME, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHYANNIS, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Simplified, Gross Ton
73 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
17 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
20 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8352698
18 February 2026
Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8312320
21 February 2025
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8082601
15 May 2024
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7897401
25 April 2024
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7899656
5 April 2023
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7661550
14 April 2022
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7431160
14 March 2022
Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7404641
25 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7170191
25 June 2020
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7089753
17 March 2020
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6923707
16 February 2019
Examination of Repairs · Deficiency Check · Plan Review "T" Boat · COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6632832
27 April 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6395586
15 March 2018
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6368372
9 May 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6139908
28 April 2016
Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5865712
4 March 2016
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5824707
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 April 2024
Resolved
STARBOARD MAIN DECK RAIL STANCHIONS (02) FRACTURED AT BASE. REWELD OR RENEW.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 April 2024
Resolved 9 May 2024
Resolution: V-OUT REWELDED.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 April 2024
Resolved
PLASTIC PIPE PENETRATION OF WTB ENGINE ROOM TO TANK ROOM. REPLACE WITH METALIC, W/SHUTOFF VALVES ON EACH SIDE.
Action required: 705 - Other - as specified
Due 25 April 2024
Resolved 9 May 2024
Resolution: STEEL PIPE WITH UNIONS THRU BULKHEAD, METALIC BALL VALVE ON EACH SIDE.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 April 2023
Resolved
Vessel has a fixed fire detection system installed in all below deck spaces including the engine room. All stations failed testing with smoke. Repair or replace the fire detection system with a system that is approved in accordance with CFR part 76.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2023
Resolution: Conducted an operational test of the fixed fire detection system
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 14 March 2022
Resolved
Whenever damage or deterioration to the hull plating or structural members that may affect the seaworthiness of a vessel is discovered, the OCMI may conduct an internal structural exam in any affected space. Crack found on main deck IWO hatch to fwd peak. Make repairs to affected area to the satisfaction of attending Marine Inspector. Prior to credit drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 April 2022
Resolved 14 April 2022
Resolution: Repairs conducted to the satisfaction of the CG MI.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 May 2019
Resolved
FCC EXPIRED.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 30 May 2019
Resolution: Completed FCC station safety license renewal.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 February 2019
Resolved
Missing items, expired items in first aid kit.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 17 May 2019
Resolution: Purchased new first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 February 2019
Resolved
Provide approved DVTP / QFA for new engine controls.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2019
Resolved 30 April 2020
Resolution: Approved DVTP / QFA provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 April 2018
Resolved
Battery for the light has expired. Replace battery.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2018
Resolved 1 May 2018
Resolution: Vessel rep replaced battery.
Construction/Loadline › Penetrations › Pipe Flange
Issued 27 April 2018
Resolved
Bulkhead penetration in engine room needs to filled with fire retardant material.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2018
Resolved 1 May 2018
Resolution: Vessel rep repaired penetration.
Engineering › Bilge Water Management System › Not Operational
Issued 27 April 2018
Resolved
Bilge alarms are not labeled properly.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2018
Resolved 1 May 2018
Resolution: Bilge alarms have been identified properly.
Construction/Loadline › Structures › Scuttle
Issued 15 March 2018
Resolved
Make deck and supporting beam wood repairs in way of forepeak scuttle.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 1 May 2018
Resolution: Verified repairs of forward deck iwo of forward hatch; all sat.
Engineering › Bilge Water Management System › Pump
Issued 9 May 2017
Resolved
FWD storage void submersible bilge pump does not work. Repair or replace and demonstrate to CG satisfaction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2017
Resolved 23 May 2017
Resolution: Pump has been repaired.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 May 2017
Resolved
Vessel does not have lifejacket donning placards. Provide and post to CG satisfaction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2017
Resolved 23 May 2017
Resolution: Donning placard has been installed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 May 2017
Resolved
Child lifejacket stowage is not properly marked and/or stenciled. Restencil stowage location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2017
Resolved 23 May 2017
Resolution: Child lifejacket stowage is now properly marked and/or stenciled.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 May 2017
Resolved
Battery terminals are severely corroded. Clean terminals and clean out the battery box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2017
Resolved 23 May 2017
Resolution: Battery terminals have been cleaned.