MAURY USCG vessel records
← All vessels

KANALOA

KANALOA is a 1998 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in July 2026, along with 42 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 15 July 2026.

Built
1998
Last inspected
15 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 July 2026
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY5919
475602
Flag
UNITED STATES
Maury page id
psix-475602

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 27

15 July 2026 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 8439257
6 April 2026 Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8343914
11 September 2025 Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8235040
14 August 2024 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7971873
16 November 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7825608
20 September 2023 Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7795382
23 February 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7640583
14 February 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7642917
2 November 2022 Deadweight Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7587855
9 August 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7528654
12 February 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7396886
4 August 2021 Deficiency Check · Drydock Exam · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7275732
30 March 2021 DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7170798
19 August 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7036897
12 February 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6925780
5 January 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6894227
5 January 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6895872
13 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6811357
6 September 2019 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6807994
27 August 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6796330
11 July 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6752236
11 July 2019 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 6752428
15 August 2018 Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6513055
7 November 2017 Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6304797
20 September 2017 Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6271355
29 August 2017 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6255635
15 August 2016 Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5973640

Deficiency record · 42

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. (04) Type 1 life jackets installed on vessel found to be deteriorated and not in serviceable condition. Renewal required for defective jackets. Vessel carriage capacity reduced to 20 passengers until replacement jackets installed on vessel. 46 CFR 176.808(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2025
Resolved 9 October 2025
Resolution: 04 new life jackets brought aboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2025 Resolved
Each life jacket and ring buoy must be marked in clearly legible block capital letters with the vessel's name. (02) life jackets had another vessel's name. Provide proper marking and identification on all life jackets. 46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2025
Resolved 24 September 2025
Resolution: Vessel name added to 02 life jackets
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2025 Resolved
The Certificate of Inspection (COI) issued to a vessel describes the vessel, the route(s) that it may travel, the minimum manning requirements, the survival and rescue craft carried, the minimum fire extinguishing equipment and...; vessel has aboard (01) 5 B:C and is missing the (01) 10 B:C portable fire extinguisher as required by COI. 46 CFR 176.103
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2025
Resolved 3 October 2025
Resolution: Owner purchased a 3A40BC dry chem FE
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2025 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI, and the words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. One fire bucket was broken in several places, restored with a new bucket. 46 CFR 181.610
Action required: 10 - Deficiency Rectified
Due 11 October 2025
Resolved 11 September 2025
Resolution: New fire bucket was purchased and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 September 2025 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. Starboard engine RPM gauge broken, repair or replace. 46 CFR 182.410 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2025
Resolved 24 September 2025
Resolution: Received video showing gauges functioning.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 September 2025 Resolved
Each survival craft must be... Stowed in a way that any protective covers will not interfere with launching and embarkation. Life float was fitting with tight fitting tied cover that inhibited easy access. Remove cover or make arrangements to improve access to life float in an emergency.46 CFR 180.130 (a) (8)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2025
Resolved 24 September 2025
Resolution: Life float cover now secured with a easily removable bungee cord
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2025 Resolved
A suitable metal marine type strainer... will specify if a flame shield is required. Vessel is equipped with 02 twist on fuel filters below deck (Racor B32013) equipped with plastic bowls. Replace with Racor metal bowls. 46 CFR 182.455 (b) (6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2025
Resolved 11 November 2025
Resolution: Vessel replaced plastic fuel filters with metal spin on type.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 September 2025 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. Vessel was missing (03) red hand flares. 46 CFR 180.68
Action required: 10 - Deficiency Rectified
Due 11 October 2025
Resolved 11 September 2025
Resolution: 03 new red hand flares were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 August 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. High water float did not provide audible alarm. 46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2024
Resolved 26 August 2024
Resolution: New bilge high water float switch purchased and installed. All sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 August 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol swabs on board were expired. Requires replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2024
Resolved 26 August 2024
Resolution: New alcohol swabs purchased and installed on vessel.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 November 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, orfire extinguishing equipment. In 2017 vessel changed collar structures and did not notify local USCG [name withheld] structural approvals have not be granted for this vessel. Provide collar structural plans to the Marine Safety Center for approval. 46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2023
Resolved 14 March 2024
Resolution: MSC reviewed and examined supporting calculations.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 September 2023 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Port running light housing unit was cracked and light was inoperable. Provide navigation lights that are in compliance with the Navigation Rules. 46 CFR 183.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2023
Resolution: Nav lights operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 September 2023 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 46 CFR 181.500(a) and other provisions of this section. Operating station missing 01 B-1, C-1 potable extingisher. Provide 01 B-1, C-1 fire extinguisher at operating station. 46 CFR 181.500(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2023
Resolved 23 October 2023
Resolution: 01 extinguisher provided at helm.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 9 August 2022 Resolved
The authority issuing the stability letter may dispense with the requirements of the simplified stability proof test when the the vessels stability can be adequately assessed by alternate means. KANALOA had a change to its hull in 2017 by switching inflatable collars. No means of adequately assessing the vessels stability could be made after this date. Vessel required to conduct stability test in accordance with MARINE SAFETY CENTER TECHNICAL NOTE (MTN) NO. 1-08, CH-2. 46 CFR 178.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 2 November 2022
Resolution: Deadweight survey completed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 August 2022 Resolved
An embarkation ladder, approved IAW 160.017 in sub-chapter Q of this chapter. Port side embarkation ladder bolt holes are worn. Repair holes. 46 CFR 180.50 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 31 August 2022
Resolution: New plate welded and holed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 August 2022 Resolved
Construction and arrangement must allow for safe operation. Cracks located on outboard side of aft mounting plate starboard side for bimini. Make repairs to mounting plate. 46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 31 August 2022
Resolution: Repair made to mounting plate.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 August 2022 Resolved
Rescue boat must be marked with retro-reflective material. Retro-reflective materiel has faded/wasted. Provide new retro-relective materiel. 46 CFR 185.604(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 31 August 2022
Resolution: Retro tape provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 August 2022 Resolved
Floating water light lanyard for ring buoy (3 to 6 ft in length) and life float (18 ft in length) must be provided. Both lanyards showing damage due to UV light. Provide new lanyards. 46 CFR 180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 31 August 2022
Resolution: Line provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 August 2022 Resolved
Stability letter must be on board in weather-tight container readily available for use by the crew and display to passengers and other on request. Stability letter not on vessel. Provide stability letter. 46 CFR 176.306
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 2 September 2022
Resolution: Stability letter provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 August 2022 Resolved
The master and crew will be familial with and have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard. Emergency instructions not provided. 46 CFR 185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 2 September 2022
Resolution: Emergency instructions provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 August 2022 Resolved
All circuits must be clearly marked and identified. Circuits at helm panel not marked or identified. Provide marking/identification. 46 CFR 183.220(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 5 September 2022
Resolution: Circuits marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 August 2022 Resolved
Blower duct must be rigid and made of same materiel as the hull or noncombustible material. Blower ducting under helm holed at connection. Provide new ducting. 46 CFR 182.460
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 5 September 2022
Resolution: New ducting provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 August 2021 Resolved
A vessel must have operational navigation sidelights. Port navigation sidelight extinguished. Provide operational port navigation sidelight. 46 CFR 183.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2021
Resolution: New nav light installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 August 2021 Resolved
Construction and arrangement must allow for safe operation. Cracks located on outboard side of aft mounting plate of both port and starboard sides for bimini. Make repairs to mounting plate. 46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2021
Resolved 16 August 2021
Resolution: Cracks welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2021 Resolved
Vessel has a mechanical exhaust system powered by blower with ventilation ducts. Ventilation ducts holed and have temporary repairs. Replace ducting to make permanent repair. 46 CFR 182.460
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2021
Resolved 16 August 2021
Resolution: New ducts installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Dead end wire leading from transom to engine. Trace and remove wire or install according to manufacturer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2021
Resolved 16 August 2021
Resolution: Dead end wire removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Electrical equipment exposed to the weather must be watertight. A hole on helm where switch used to be under stereo allows rain and seawater to drip on to electrical equipment. Make electrical equipment watertight or provide blank to close hole. 46 CFR 183.210(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2021
Resolved 16 August 2021
Resolution: Blank provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2021 Resolved
Vessel exhaust blower interlock not operational on vessel that has fuel tanks for gasoline. Blower switch must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. Provide operational interlock. 46 CFR 182.460
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2021
Resolved 21 August 2021
Resolution: Interlock installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Provide Letter of Regulatory Compliance (LORC) for Reliable Drug Testing Services Consortium.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Update EAP Information to reflect current changes to DAPI program (i.e., Provide EAP information posted in vessel common space; Identify SAP and update EAP information with contact information; Hot-line information, etc).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Provide the DAPI covered employees list for BWR vessels. Confirm all employees have record of preemployment test or subject to random since COVID-19 shutdown.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel (continued on second page).Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Confirm Blue Water Rafting's policy regarding employment for mariner's who have tested positive on any of the five types of DOT chemical tests and the MRO return to work process.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2021
Resolved 6 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 August 2020 Resolved
Gauges at helm not operating. Provide operational RPM, oil pressure, and cooling water temp gauges at helm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 31 August 2020
Resolution: New RPM indicator installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2020 Resolved
Engine alarm due to O2 sensor sounding on starboard engine. Repair engine to ensure all alarms cleared and system made fully operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 28 August 2020
Resolution: Replaced o2 sensor. All alarms cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 August 2019 Resolved
Radio Safety Certificate was expired. Provide current certificate in accordance with 46 CFR 184.502.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 13 September 2019
Resolution: Current certificate provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 September 2017 Resolved
Navigation lights inoperative. Vessel is restricted to daytime operations.
Action required: 705 - Other - as specified
Resolved 29 September 2017
Resolution: Nav lights operable.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 September 2017 Resolved
Battery tray covers were not present and trays were not secured.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 21 September 2017
Resolution: Covers provided and secured.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 15 August 2016 Resolved
Provide Proof that the installed fixed fire system has been service with in the last year.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Vessel purchased a new bottle.
Unknown
Issued 15 August 2016 Resolved
Repair or replace Stbd aft sponson to meet 5% pressure drop test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Vessel repaired sponson. I informed company that sponson was looking a bit worn and may need to be replaced at next inspection.
Lifesaving › Lifebuoys › Serviceable
Issued 15 August 2016 Resolved
Provide serviceable 24" lifering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Vessel purchased and installed new lifering.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 August 2016 Resolved
Vessel operating beyond the Certificate of Inspection expriation date.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2016
Resolved 15 August 2016
Resolution: Vessel completed COI.

Ownership record