Records from 2016 to 2026. Most recent: inspection, 30 April 2026.
Inspection history · 20
30 April 2026
Internal Structural Exam · Deficiency Check · COI Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8359354
29 May 2025
Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8149662
28 May 2025
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8183462
6 May 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8110306
29 April 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7899280
19 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7891824
2 May 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7665702
23 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7444405
25 April 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7420608
26 April 2021
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7162915
23 April 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6936464
7 April 2020
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6936467
23 April 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6658441
27 April 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6385235
20 April 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6385222
21 April 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6079631
5 July 2016
Damage Survey · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5930505
29 June 2016
Initial Construction-Excluding Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5923484
28 April 2016
COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5864447
25 February 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5821975
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 May 2026
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Provide closure devices.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2026
Resolved 27 May 2026
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 May 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. The required analgesics and burn gel were missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2026
Resolved 27 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Renew the grabline on the vessel's ring life buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2025
Resolved 16 June 2025
Resolution: New ring life buoy placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025
Resolved
Each lifeline on a ring life buoy must be buoyant;be of at least 18.3 meters (60 feet) in length;be non-kinking;ahve a diameter of at least 7.9 millimeters (5/16 inch);have a breaking strength of at least 5 kilonewtons (1,124 pounds); and be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Renew the lifeline.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2025
Resolved 16 June 2025
Resolution: Renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025
Resolved
Each ring life buoy must be marked with Type II retroreflective material. Add retroreflective tape to the lifebuoy and identified lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2025
Resolved 2 June 2025
Resolution: Retroreflective tape added.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 May 2025
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Prove operation of the audible alarm at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2025
Resolved 2 June 2025
Resolution: New high water alarm installed and operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Exposed wires were present at the fwd light for the engine space. Reconnect to the light or remove the electrical wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2025
Resolved 16 June 2025
Resolution: dead end wires removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Exposed wires were present on the starboard side of the engine. The insulation on a black wire was cut in two places exposing the wire and a dead end wire was located adjacent to, without a connector. Remove the electrical tape around the wires for further inspection and renew the identified wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 9 May 2024
Resolution: Identified wires renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 May 2023
Resolved
A vessel on a lakes, bays, and sounds route must carry three red hand flares and three orange smoke signals or six red hand flares. Only four flares onboard.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 2 May 2023
Resolution: Obtained 2 additional flares that were placed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 May 2023
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard and the words "FIRE BUCKET" stenciled in a contrasting color. Only 2 fire buckets onboard with no lanyards or markings.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 2 May 2023
Resolution: Additional fire bucket obtained and all buckets are properly marked with attached lanyards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2022
Resolved
Life buoy did not have retroreflective tape. Properly apply tape to life buoy.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2022
Resolution: Bought new life ring with retroreflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 May 2020
Resolved
Replace grab rotten grab line on life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2020
Resolved 6 May 2020
Resolution: New life ring installed, marked and properly outfitted.