MAURY USCG vessel records Sign in
← All vessels

CAPT. RAYNE

CAPT. RAYNE is a 1973 offshore supply vessel. The Coast Guard has recorded 67 inspections since 1981, most recently in February 2009, along with 145 deficiencies and 1 casualty investigation in 2009.

Records from 1981 to 2009. Most recent: casualty investigation, 28 May 2009.

Built
1973
Last inspected
5 February 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7573
Flag
UNITED STATES
366848780, 367073480 (licence lapsed)
Maury page id
psix-47566

Inspections, by type

…with no type recorded10
Years with a record 29 calendar years (1981–2009)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC7573MMSI 367073480 · expired · compulsorily equipped · granted 26 October 2005, cancelled 26 December 2015
WDA7934MMSI 366848780 · expired · compulsorily equipped · granted 24 April 2002, cancelled 30 June 2012 · licensed under a name not among this hull’s recorded names (not shown)
WYT8226MMSI not assigned · expired · compulsorily equipped · granted 14 June 1994, cancelled 16 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 67

5 February 2009 Re-Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3412745
8 February 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3144369
30 January 2007 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2863952
7 March 2006 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2598035
12 October 2005 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2512538
4 May 2005 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2349115
7 April 2005 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2334708
11 March 2005 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2334687
13 April 2004 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2043299
30 May 2003 Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1808442
8 April 2003 Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1770314
23 January 2003 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1734296
24 May 2002 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1620313
10 August 2001 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1422122
1 August 2001 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1471623
7 June 2001 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1065266
1 May 2001 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1362174
19 April 2001 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1362150
26 February 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1046478
8 February 2000 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1469610
10 May 1999 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1463467
26 March 1999 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1446744
15 April 1998 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 788911
23 March 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1124480
26 February 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 781048
11 February 1998 Deficiency Check · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1450130
6 June 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777011
24 May 1997 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1443870
12 February 1997 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1388209
24 May 1996 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1090450
6 March 1996 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 884763
23 February 1996 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1390199
25 September 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1189123
24 May 1995 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1374295
28 February 1995 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1470674
7 December 1994 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1422452
1 December 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 89667
21 March 1994 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1461566
2 March 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1446066
27 May 1993 Hull Examination · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 833782
17 March 1993 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1151874
8 March 1993 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1324334
8 May 1992 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1260419
13 March 1992 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1261204
10 March 1992 Deficiency Check · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1269322
6 November 1991 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1312882
21 March 1991 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1243530
14 March 1991 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1234710
14 March 1991 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1234997
11 May 1990 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 930284
23 March 1990 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1239016
2 November 1989 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1004443
21 March 1989 Deficiency Check · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1344470
24 February 1989 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1193983
12 January 1989 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1209274
10 November 1988 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1207947
23 March 1988 Deficiency Check · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1032542
19 March 1987 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1331444
25 March 1986 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1305649
11 May 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286656
28 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1288208
24 August 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1282443
12 April 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 977292
7 April 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1276464
11 May 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1276136
14 April 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 965891
14 May 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 971018

Deficiency record · 145

Fire Fighting › Fire Pumps › Gland Sealing
Issued 5 February 2009 Resolved
Fire pump not providing 60 psi pressure on one hose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2009
Resolution: Pump seal replaced. Pump tested to 70 psi
Lifesaving › Lifebuoys › Serviceable
Issued 5 February 2009 Resolved
Lifebuoy not serviceable. No manufacture information sticker and body cracking
Due 16 March 2009
Resolved 12 February 2009
Resolution: New lifebuoy purchased and placed on vessel.
Lifesaving › Lifefloat › Float-free Link
Issued 5 February 2009 Resolved
Float-free link had no tag verifying breaking strength
Due 16 March 2009
Resolved 12 February 2009
Resolution: New float free link attached to lifefloat
Fire Fighting › Fire Pumps › Vacuum Pump
Issued 5 February 2009 Resolved
No Hand Fire pump on board
Due 16 March 2009
Resolved 12 March 2009
Resolution: Hand fire pump purchased and placed on board
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 February 2009 Resolved
Emergency light in generator room not operating
Due 16 March 2009
Resolved 12 February 2009
Resolution: New light installed
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 5 February 2009 Resolved
No latches on refrigerator/freezer doors
Due 16 March 2009
Resolved 12 February 2009
Resolution: Latches placed on refrigerator/freezer doors
Electrical › Lighting (service) › Lighting Fixture
Issued 5 February 2009 Resolved
No guard on stove light in galley
Due 16 March 2009
Resolved 12 February 2009
Resolution: Guard placed on light
Fire Fighting › Portable Foam Applicators › General
Issued 5 February 2009 Resolved
Foam eductor not operating properly
Due 16 March 2009
Resolved 12 February 2009
Resolution: Eductor repaired and operating properly
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 8 February 2008 Resolved
Lifejacket lights are expired and need to be replaced.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 February 2008 Resolved
Replace line on starboard ring buoy. Ring buoys and life floats need to be properly stenciled on both sides.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 February 2008 Resolved
Remove all dead end wiring throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Stability › Watertight Integrity › General
Issued 8 February 2008 Resolved
Place hard gasket on watertight door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2008
Stability › Weathertight Integrity › General
Issued 8 February 2008 Resolved
Replace ball valves on compartment vents.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Communications › Radio Communications › EPIRB
Issued 8 February 2008 Resolved
Replace antenna on EPIRB. Renew registration and hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2008
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 8 February 2008 Resolved
Remove all stores from berthing area below.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Engineering › Bilge Water Management System › Piping
Issued 8 February 2008 Resolved
Secure water ingress on piping of suction bilge.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2008
Resolved 14 February 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 8 February 2008 Resolved
Replace broken light bulbs in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 8 February 2008 Resolved
Replace emergncy lighting in generator room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 February 2008 Resolved
Fix fuel shut off reach rod on the port side of the vessel.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Breaker (overload/over current protection)
Issued 8 February 2008 Resolved
Fix overspeed on starboard generator.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 8 February 2008 Resolved
Properly secure freezer, washer and dryer.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Construction/Loadline › Structures › Door
Issued 8 February 2008 Resolved
Replace upper left missing dog on forward compartment emergency exit.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 8 February 2008 Resolved
Fire extinguisher in galley area is under charged. Must be recharged or replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 February 2008 Resolved
Port enging needs guard on front side pulley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Fire Fighting › Fire Pumps › Arrangement
Issued 8 February 2008 Resolved
Replace wiring on the fire pump junction box with marine grade wire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Engineering › Steering Gear System › Hydraulic Hose
Issued 8 February 2008 Resolved
Replace or repair leak in hydraulic line on the port side of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 8 February 2008 Resolved
Dryer needs lint box or to be vented outside.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Construction/Loadline › Structures › Door
Issued 8 February 2008 Resolved
Door alarms are improperly wired. Either remove or fix.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Engineering › Generator (propulsion-electric) › Winding
Issued 8 February 2008 Resolved
Clean windings on starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Electrical › Electrical Distribution System (emergency) › Outlet Box
Issued 8 February 2008 Resolved
Marine sanitation device needs to be hard wired. Outlet needs to be grounded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 8 February 2008 Resolved
Repair through hull penetration at fire main piping in engine room (starboard). Replace corroded piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 February 2008
Fire Fighting › Fire Pumps › Pressure
Issued 8 February 2008 Resolved
Fire pump is required to have a pressure of at least 60 PSI. Pump currently has 40 PSI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2008
Operations/Management › Drills/Instruction › Abandon Ship
Issued 8 February 2008 Resolved
Conduct fire and man overboard drill in presence of attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2008
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Nozzle, Injection (fuel injection)
Issued 8 February 2008 Resolved
Replace return line for main engines
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Engineering › Diesel Engine (propulsion-electric) › Gear, Timing
Issued 8 February 2008 Resolved
Replace or fix middle main diesel engine guage wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 8 February 2008 Resolved
Place double clamps on starboard generator cooling water line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Engineering › Compressed Air System (start air) › Control Gear
Issued 8 February 2008 Resolved
Replace pressire switch cable on starboard air receiver.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 February 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 February 2007 Resolved
Deadended electrical wires hanging throughout E/R. Remove all deadended wires.
Action required: 705 - Other - as specified
Due 13 March 2007
Resolved 13 February 2007
Resolution: All deadended cables removed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 February 2007 Resolved
E/R deck plates were missing support beams on STBD side of center engine. Replace missing support beams as original.
Action required: 705 - Other - as specified
Due 12 March 2007
Resolved 13 March 2007
Resolution: Support beams replaced for deck plates.
Engineering › Bilge Water Management System › Pump
Issued 12 February 2007 Resolved
Bilge pump was not mounted and wiring was exposed out of pump. Mount pump and rewire properly.
Action required: 705 - Other - as specified
Due 12 March 2007
Resolved 13 February 2007
Resolution: Bilge pump was hard mounted and rewired.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 February 2007 Resolved
Two of vessels life float lights were not working. Replace or repair lights.
Action required: 705 - Other - as specified
Due 9 March 2007
Resolved 12 February 2007
Resolution: Both life float lights were repaired and are working properly.
Electrical › Electrical Distribution System (service) › Cable
Issued 30 January 2007 Resolved
Armor for cable for firepump is damaged resulting in loss of bonding. Renew cable to original.
Action required: 705 - Other - as specified
Due 12 March 2007
Resolved 13 March 2007
Resolution: New cable installed for fire pump.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 7 March 2006 Resolved
Repair overspeed on port generator, and provide overspeed for stbd generator.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2006
Resolved 9 March 2006
Resolution: Operator installed overspeed on stbd generator and repaired port generator overspeed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 March 2006 Resolved
Label Hi-water alarm panel on bridge.
Condition: Improper/Lack of Maintenance
Due 7 April 2006
Resolved 13 July 2006
Construction/Loadline › Structures › Door
Issued 7 March 2006 Resolved
Repair WTD indicator light for generator room door.
Condition: Improper/Lack of Maintenance
Due 7 April 2006
Resolved 13 July 2006
Communications › Radio Communications › EPIRB
Issued 7 March 2006 Resolved
Replace expired hydrostatic release on EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2006
Resolved 9 March 2006
Resolution: New hydrostatic release installed.
Lifesaving › Lifefloat › Painter
Issued 7 March 2006 Resolved
Re-rig lifefloats to required arrangement, ensure painter lengths are correct length for manual deployment.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2006
Resolved 9 March 2006
Resolution: Lifefloats properly rigged.
Lifesaving › Lifebuoys › Approval
Issued 7 March 2006 Resolved
Mark lifebuoys with retro-reflective tape on both sides of all lifebuoys.
Condition: Improper Installation
Due 7 April 2006
Resolved 13 July 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 7 March 2006 Resolved
Provide exhaust pipe hangers port engine and port generator.
Condition: Improper/Lack of Maintenance
Due 7 April 2006
Resolved 13 July 2006
Construction/Loadline › Structures › Manhole
Issued 7 March 2006 Resolved
Breakfree escape hatch in fwd crew compartment and repair dogging handles and striker plates.
Condition: Improper/Lack of Maintenance
Due 7 April 2006
Resolved 13 July 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 March 2006 Resolved
Put blanks in empty sockets in electrical panelboards.
Condition: Improper Installation
Due 7 April 2006
Resolved 13 July 2006
Engineering › Fuel Oil Service System › Hose
Issued 7 March 2006 Resolved
Replace flexible fuel hoses on stbd generator.
Condition: Improper/Lack of Maintenance
Due 7 April 2006
Resolved 9 March 2006
Resolution: New hoses installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 March 2006 Resolved
Repair damaged light fixtures in engine room and passenger bathroom.
Condition: Improper/Lack of Maintenance
Due 7 April 2006
Resolved 13 July 2006
Documentation › Markings/Placards › Official Number (US)
Issued 7 March 2006 Resolved
Punch mark official number into collision bulkhead.
Condition: Improper Installation
Due 7 April 2006
Resolved 13 July 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 March 2006 Resolved
Dye pen crack in WTD coaming, properly weld crack.
Condition: Damaged By Earlier Event
Due 7 April 2006
Resolved 13 July 2006
Documentation › Certificates/Documents › FCC SSL
Issued 7 March 2006 Resolved
Provide FCC Safety Certificate.
Condition: Placed in Improper Service
Due 7 April 2006
Resolved 13 July 2006
Construction/Loadline › Structures › Door
Issued 7 March 2006 Resolved
Provide door handle stop on WTD for forward crew compartment.
Condition: Improper Installation
Due 7 April 2006
Resolved 13 July 2006
Electrical › Electric Generation Source (service) › Generator
Issued 7 March 2006 Resolved
Professionally clean generator armatures.
Condition: Improper/Lack of Maintenance
Due 7 April 2006
Resolved 13 July 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 March 2006 Resolved
Provide Not Under Command lights.
Condition: Improper Installation
Due 7 April 2006
Resolved 13 July 2006
Fire Fighting › Means of Escape › Blocked
Issued 7 March 2006 Resolved
Lower passenger compartment vertical escape hatch covered and inaccessible. New owner/operator to put back to original approved plans arrangement. Vsl may not carry passengers in lower compartment until corrected. Passenger count reduced to upper deck fixed seating. Vsl to correct at next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 February 2007
Resolution: Vessel owner decided to lower passenger count permanently and not allow passengers below the main deck. Two means of escape are provided for the crew.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 7 April 2005 Resolved
REPLACE SEAL WTD STBD SIDE AFT
Due 14 April 2005
Resolved 7 April 2005
Lifesaving › Lifebuoys › Serviceable
Issued 7 April 2005 Resolved
REPLACE STBD FWD LIFEBUOYS
Due 14 April 2005
Resolved 7 April 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 April 2005 Resolved
INSTALL MACHINERY GUARD OVER SHAFT
Due 14 April 2005
Resolved 7 April 2005
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 11 March 2005 Resolved
Replace starboard cutlass bearing
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 5 May 2005
Electrical › Electric Supply System (service) › Cable
Issued 11 March 2005 Resolved
install electrical through hull fittings for wires on the port side
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 5 May 2005
Electrical › Electrical Distribution System (service)
Issued 13 April 2004 Resolved
Properly terminate electrical wire under bridge console and repair oil leak from oil sending unit.
Condition: Improper Installation
Due 20 April 2004
Resolved 10 May 2004
Lifesaving › Visual Distress Signals Launcher
Issued 13 April 2004 Resolved
Replace battery EPRIB
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2004
Resolved 10 May 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 13 April 2004 Resolved
Mark out [name withheld] name on eight lifejackets LEGACY COMPONENT DESC: Marking
Due 20 April 2004
Resolved 10 May 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 April 2004 Resolved
Install machinery guard on engine and steering motor
Due 20 April 2004
Resolved 10 May 2004
Electrical › Electric Generation Source (service)
Issued 13 April 2004 Resolved
Replace port generator cable LEGACY COMPONENT DESC: Generator Cable
Due 20 April 2004
Resolved 10 May 2004
Engineering
Issued 23 January 2003 Resolved
REMOVE COMBUSTIBLES FROM GENERATOR SPACE.
Due 23 January 2003
Resolved 23 January 2003
Lifesaving › Visual Distress Signals (General) › Storage
Issued 23 January 2003 Resolved
STOW EXPIRED DISTRESS SIGNALS IN SEPERATE CONTAINER THAN CURRENT DISTRESS SIGNALS.
Condition: Placed in Improper Service
Due 23 January 2003
Resolved 23 January 2003
Fire Fighting
Issued 1 May 2001 Resolved
Provide nozzles for fire hoses prior to operation.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Lifesaving
Issued 1 May 2001 Resolved
Provide expiry date for EPIRB hydrostatic release.
Condition: Unknown
Due 1 May 2001
Resolved 2 May 2001
Construction/Loadline
Issued 1 May 2001 Resolved
Provide bilge alarms for two (2) compartments midships iwo A/C condensor unit.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Navigation
Issued 1 May 2001 Resolved
Correct linkage travel path to prevent contact with hydraulic ram assembly.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Engineering
Issued 1 May 2001 Resolved
SECURE OIL LEAK FROM PORT ENGINE TURBO HOUSING AND CLEAN OR REPLACE OIL SOAKED EXHAUST MANIFOLD LAGGING.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Engineering
Issued 1 May 2001 Resolved
PROVIDE PRESSURE RELIEF VALVES ON CONTROL AIR RECEIVERS (2) IN LAZZARETTE.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Accommodation/Occupational Safety
Issued 1 May 2001 Resolved
REPAIR CRACKED DECK BEAM AND REATTACH DECK PLATE BEHIND CENTER MAIN ENGINE.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Electrical
Issued 1 May 2001 Resolved
PROVIDE DRIP COVER FOR ELECTRICAL BOX BELOW STARBOARD ENGINE ROOM FRESH AIRVENT.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Navigation
Issued 1 May 2001 Resolved
PROVIDE RUDDER STOPS FOR BOTH RUDDERS.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Construction/Loadline
Issued 8 February 2000 Resolved
Install high level bilge alarms as required in 46 CFR 182.530.
Condition: Unknown
Due 8 February 2000
Resolved 8 February 2000
Lifesaving
Issued 26 February 1998 Resolved
REPAIR/REPLACE 1 LIFE FLOAT, ASSOCIATED WATER LIGHTS AND WEAK LINKS DAMAGEDIN STORM.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Engineering
Issued 26 February 1998 Resolved
REPAIR CENTER ENG EXHAUST COOLING SYSTEM.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Documentation
Issued 11 February 1998 Resolved
PROVIDE WASTE MGT PLAN.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Lifesaving
Issued 11 February 1998 Resolved
PROPERLY MARK PFD STORAGE IAW 46 CFR 185.604 (F).
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Lifesaving
Issued 11 February 1998 Resolved
PROVIDE RESCUE PLATFORM.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Lifesaving
Issued 11 February 1998 Resolved
PROVIDE PORTABLE WATERTIGHT CONTAINER FOR FLARES W/PROPER MARKINGS IAW 46CFR 185.614.
Condition: Unknown
Due 11 February 1998
Resolved 18 February 1998
Lifesaving
Issued 11 February 1998 Resolved
PROPERLY MARK EPIRB W/VSLS NAME.
Condition: Unknown
Due 11 February 1998
Resolved 18 February 1998
Engineering
Issued 11 February 1998 Resolved
MAKE REPAIRS TO STBD ENGINE EXHAUST. (CRACKS IN WATER COOLED EXHAUST SYSTEMLEAKING)
Condition: Unknown
Due 11 February 1998
Resolved 18 February 1998
Lifesaving
Issued 11 February 1998 Resolved
REPLACE/REPAIR PAINTER LINES AQND ONE WATERLIGHT LINE, FOR LIFEFLOATS.
Condition: Unknown
Due 11 February 1998
Resolved 18 February 1998
Engineering
Issued 11 February 1998 Resolved
REPLACE WIRE NUTS WITH PROPER CONNECTORS ON STBD MAIN ENGINE TACH.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Navigation
Issued 11 February 1998 Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Construction/Loadline
Issued 11 February 1998 Resolved
PROVE WATERTIGHT INTEGRITY OF ALL WATERTIGHT DOORS PRIOR TO 26 FEB 98.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Lifesaving
Issued 11 February 1998 Resolved
PROVIDE LIFEJACKET PLACARD IN LOUNGE AREA.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Lifesaving
Issued 11 February 1998 Resolved
MARK RING BUOYS W/RETRO TAPE.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Unknown
Issued 11 February 1998 Resolved
UPDATE EXPIRED FIRST AID KIT.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Construction/Loadline
Issued 11 February 1998 Resolved
REPLACE CURRENT WATERTIGHT DOORS BELOW MAIN DECK WITH QUICK ACTING WATERTIGHT DOORS PRIOR TO 11MAR98. WATERTIGHT DOORS ARE TO BE INSTALLED TOTHE SATISFACTION OF COGNIZANT [name withheld] 46 CFR 170.270 (a)(d).
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Construction/Loadline
Issued 11 February 1998 Resolved
MAKE PERM.REPAIRS TO INSPECTION PORT ON MAIN DECK IWO WINDLASS.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Engineering
Issued 11 February 1998 Resolved
REPLACE POP-OFFS ON BOTH AIR RECEIVERS. (NEITHER RESET AFTER RELIEVING)
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Electrical
Issued 11 February 1998 Resolved
PROVIDE BLANKS FOR GEN CONTROL PANEL AND AFT ENG RM BRKR PANEL.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Unknown
Issued 11 February 1998 Resolved
REPLACE PLASTIC WIRE TIES WITH METAL FASTENERS THROUGHOUT ENGINEROOM AND WHEELHOUSE.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Electrical
Issued 11 February 1998 Resolved
REPLACE/PROPERLY SPLICE CABLE FROM STARTER TO BATTERY ON PORT GENERATOR.
Condition: Unknown
Due 26 February 1998
Resolved 27 February 1998
Construction/Loadline
Issued 23 February 1996 Resolved
Make permanent repairs to 'V' shaped web bracket, located where #2 transverse frames meet in the forepeak.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Fire Fighting
Issued 23 February 1996 Resolved
Replace holed 1.5" fire hose. Vessel requires two acceptable 1.5" fire hoses on board proir to vessel getting underway.
Condition: Unknown
Due 26 February 1996
Resolved 26 February 1996
Engineering
Issued 23 February 1996 Resolved
Repair pinhole leak in aft exhaust line on port engine, port side bulkhead.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Engineering
Issued 23 February 1996 Resolved
Renew center exhaust sleeve on port engine, port side bulkhead.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Construction/Loadline
Issued 23 February 1996 Resolved
Make permanent repairs to fracture where port generator exhaust joins the port bulkhead.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Lifesaving
Issued 7 December 1994 Resolved
WHEN VESSEL IS AFLOAT, AWAY FORM BEACH INSPECT VESSEL SPACES FOR FLOODING/DAMAGE.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Lifesaving
Issued 7 December 1994 Resolved
IF VESSEL IS TAKING ON WATER/FLOODING MAKE TEMP. REPAIRS TO AREAS LEAKING PRIOR TO ENTERING FREEPORT JETTIES.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Construction/Loadline
Issued 7 December 1994 Resolved
MAKE VESSEL AVAILABLE FOR DRY DOCK EXAM.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 7 December 1994 Resolved
MAKE TEMP. REPAIRS TO PORT AND STARBOARD AIR RECIVERS BY WELDING CRACKS, HYDRO. TEST TO 1.5 MAWP, X-RAY WELD AND INSTALL 125 PSI RELIEF VALVE.
Condition: Unknown
Due 7 December 1994
Resolved 16 December 1994
Lifesaving
Issued 7 December 1994 Resolved
PLACE A DEWATERING PUMP ONBOARD VESSEL PRIOR TO PULLING VESSEL OFF GROUND
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 7 December 1994 Resolved
RENEW PORT AND STARBOARD AIR RECIVERS PRIOR TO 02MAR95.
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Engineering
Issued 2 March 1994 Resolved
REPAIR SMALL EXHAUST COOLING WATER LEAK (PORT SIDE) FOR MAIN DIESEL ENGINE.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Construction/Loadline
Issued 2 March 1994 Resolved
REPAIR OR REPLACE REACH ROD FOR FOREPEAK BILGE SUCTION
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Engineering
Issued 2 March 1994 Resolved
REMOVE PET COCKS FROM RACOR BRAND FILTERS AND PROVIDE SHIELDS.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Electrical
Issued 2 March 1994 Resolved
REPAIR OVERSPEED TRIP FOR STARBOARD GENERATOR
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Engineering
Issued 2 March 1994 Resolved
PUT GUARDS OVER FLY WHEELS FOR MAIN DIESEL ENGINES.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Construction/Loadline
Issued 8 March 1993 Resolved
MAKE CABLE IN STARBOARD AFT ENGINE ROOM BULKHEAD WATERTIGHT.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Engineering
Issued 8 March 1993 Resolved
PROPERLY REPAIR WATER LEAK IN CENTER MAIN ENGINE SEA STRAINER.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Engineering
Issued 8 March 1993 Resolved
DOUBLE HOSE CLAMP ALL SALT WATER HOSES.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Engineering
Issued 8 March 1993 Resolved
PROPERLY REPAIR SALT WATER LEAK IN PORT MAIN ENGINE PIPING.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Engineering
Issued 8 March 1993 Resolved
REMOVE PETCOCK AND INSTALL PLUGS AND FLAMESCREEN ON FUEL OIL FILTER FOR MAIN DIESEL ENGING.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Lifesaving
Issued 10 March 1992 Resolved
REPLACE (1) 15 PERSON LIFEFLOAT W/A NEW ONE.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Accommodation/Occupational Safety
Issued 10 March 1992 Resolved
REPAIR UPPER LOUNGE MSD. MAKE IT FLUSH.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Navigation
Issued 10 March 1992 Resolved
REPLACE OUTDATED RULES OF TH ROAD BOOK W/ UPDATED COPY.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Electrical
Issued 14 March 1991 Resolved
PROVE PROPER OPERATION OF STARBOARD GENERATOR OVERSPEED.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Fire Fighting
Issued 14 March 1991 Resolved
INSTALL PRESSURE GUAGE FOR FIRE PUMP.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Engineering
Issued 14 March 1991 Resolved
OBTAIN HOSE FOR HAND BILGE PUMP.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Electrical
Issued 14 March 1991 Resolved
INSTALL HANDLE FOR STARBOARD BATTERY BOX KNIFE SWITCH.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Electrical
Issued 14 March 1991 Resolved
INSTALL EXHAUST WRAP FOR STARBOARD GENERATOR.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Navigation
Issued 14 March 1991 Resolved
INSTALL ELECTRICAL COVER FOR HYDRAULIC PUMP LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Construction/Loadline
Issued 14 March 1991 Resolved
SEAL BULKHEAD PENETRATION IN GENERATOR ROOM STARBOARD SIDE.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Navigation
Issued 14 March 1991 Resolved
TIGHTEN NUTS ON PORT RUDDER STOCK.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Electrical
Issued 24 February 1989 Resolved
PROVIDE GLOBE ON LIGHT OVER SINK IN HEAD.
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Electrical
Issued 24 February 1989 Resolved
REMOVE ALL WIRING TO AFT BUNK LIGHT BACK TO THE JUNCTION BOX. IF REWIRED USE PROPER MARINE WIRING.
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Electrical
Issued 24 February 1989 Resolved
REMOVE AFT BUNK OVERHEAD LIGHT AND REPLACE WITH PROPER MARINE FIXTURE. IF NO FIXTURE IS INSTALLED REMOVE ALL WIRING FOR FIXTURE.
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Electrical
Issued 10 November 1988 Resolved
PLACE COVERS ON LIGHTS IN GENERATOR ROOM.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Construction/Loadline
Issued 10 November 1988 Resolved
RENEW GASKETS IN WATER TIGHT DOORS BETWEEN GENERATOR & MACHINERY SPACE AND MACHINERY & ACCOMODATION SPACE.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Electrical
Issued 10 November 1988 Resolved
PLACE WIRING FOR SHOWER PUMP BACK INTO JUNCTION BOX, WIRING HAS BEEN PULLEDOUT.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Accommodation/Occupational Safety
Issued 10 November 1988 Resolved
PROVIDE ENGING ROOM/GENERATOR ROOM VENTILATION IN ACCORDANCE WITH 46CFR182 20.45.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Lifesaving
Issued 28 March 1985 Resolved
PROVIDE AND POST PROPER EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 12 April 1984 Resolved
INSTALL A TYPE II OR TYPE III MARINE SANITATIONDEVICE IN ACCORDANCE WITH 33CFR 159.7(C)1 NO NLT 12JUL84.UNTIL THE ABOVE REQUIREMENT IS COMPLETED SIGNS
Condition: Unknown
Due 12 April 1984
Resolved 12 April 1984
Unknown
Issued 12 April 1984 Resolved
POSITIVE LOCK WILL BE INSTALLED ON THE SEWAGE OVERBOARD DISCHARGE.
Condition: Unknown
Due 12 April 1984
Resolved 12 April 1984

Casualty record · 1

28 May 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 3488740
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record