1987
Last inspected
15 January 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 January 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

475763
Flag
UNITED STATES
Maury page id
psix-475763

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

15 January 2026 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8283420
2 October 2025 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8241777
15 October 2024 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8019212
9 February 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7859184
19 October 2023 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7809342
10 November 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7591541
23 December 2021 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7372681
7 September 2021 Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7302078
24 August 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7041921
10 December 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6873261
28 May 2019 Annual Inspection · Construction Oversight
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6698079
27 August 2018 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6524289
1 June 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6430442
16 May 2017 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6146529
28 March 2016 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5845411
8 March 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5829508

Deficiency record · 10

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 November 2022 Resolved
Missing portable bilge hand pump at least 5 gallons per minute. Provide required hand pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2022
Resolved 10 November 2022
Resolution: Portable bilge pump is onboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 September 2021 Resolved
Pre engineered fire system does not shut down engine. Engine needs to be able to secure with the system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2021
Resolution: Vsl fixed fire system was service and corrected by tech. The system operates as intended.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2021 Resolved
Bilge high water alarm has no audible indicator. Alarm needs both audible and visual indicators.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 22 September 2021
Resolution: Bilge alarm has audible and visual alarm working.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 September 2021 Resolved
First aid kit onboard has expired eye wash and aspirin. Kit must be updated with current requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2021
Resolved 22 September 2021
Resolution: Vsl rep purchased a new first aid kit with required contents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 August 2020 Resolved
Lifejackets not easily accessible during an emergency. Each lifejacket should be readily available.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2020
Resolved 11 September 2020
Resolution: Lifejackets are labelled and stowed with easier access.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 August 2020 Resolved
Life buoy is missing retro tape. Must be in accordance with 160.050.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2020
Resolved 11 September 2020
Resolution: Life buoy has required retro tape.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 August 2020 Resolved
First-aid kit has expired aspirin and eye wash. Must have approved kit under 160.041.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2020
Resolved 11 September 2020
Resolution: Vessel has the required first aid kit onboard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 August 2020 Resolved
Fixed fire fighting doesn't have safety pin on the activation handle installed correctly. General arrangement doesn't meet the annual maintenance required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2020
Resolved 11 September 2020
Resolution: Safety pin has been replaced and is in good working order.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 August 2020 Resolved
Fire extinguisher required outside the machinery space has excessive corrosion. Required to have an extinguisher in good working order and free of excessive corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2020
Resolved 11 September 2020
Resolution: Vessel replaced fire extinguisher with new one that was serviced Aug20.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 May 2019 Resolved
The by-pass for the fire bottle will not let operator re-start engine once fire bottle has been extinguished.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2019
Resolution: Witnessed operational test

Ownership record