MAURY USCG vessel records Sign in
← All vessels

VOYAGER EAGLE

VOYAGER EAGLE is a 1973 passenger vessel (inspected). The Coast Guard has recorded 83 inspections since 1981, most recently in May 2002, along with 142 deficiencies and 1 casualty investigation in 2002.

Records from 1981 to 2002. Most recent: inspection, 7 May 2002.

Built
1973
Last inspected
7 May 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTS5229
Flag
UNITED STATES
—
Maury page id
psix-47584

Inspections, by type

…with no type recorded25
Years with a record 21 calendar years (1981–2002)
The 83 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it91 - Simplified, Gross Ton
62 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WTS5229MMSI not assigned · expired · compulsorily equipped · granted 16 January 1997, cancelled 24 March 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 83

7 May 2002 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1740681
7 April 2002 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2464142
26 March 2002 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1682014
29 November 2001 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1075941
5 July 2001 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1405268
29 March 2001 Deficiency Check · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1408738
7 July 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1403193
28 March 2000 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1468563
14 December 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 812773
12 November 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1395299
7 July 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1449205
31 March 1999 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1471190
10 July 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1455603
23 June 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 792842
12 March 1998 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1378306
23 July 1997 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1114756
10 July 1997 Re-Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1364242
6 May 1997 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1096344
12 March 1997 Examination of Repairs · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1413131
10 December 1996 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1092493
26 November 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354060
11 July 1996 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1414664
12 June 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1085923
12 June 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1085945
3 June 1996 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1390266
10 April 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1080937
28 December 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1184211
20 December 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 664451
29 October 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1186862
8 September 1995 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1442294
17 August 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 876108
31 July 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1183243
21 July 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 879956
14 July 1995 COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1470108
20 June 1995 Deficiency Check · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1385477
8 June 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 664452
25 May 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 872458
24 May 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1182648
19 May 1995 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1450974
15 May 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 664453
10 May 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 109698
3 February 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 836762
19 January 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 196660
19 January 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 754966
19 January 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 869806
21 December 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 846210
2 December 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 870532
17 November 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1179147
13 July 1994 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1417670
5 May 1994 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1436865
26 April 1994 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 664450
23 March 1994 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 15817
4 August 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1153611
27 January 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1136109
22 May 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1259465
14 May 1992 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 71656
14 May 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 958377
15 April 1992 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 957824
14 June 1991 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1315959
26 September 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1235102
18 June 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 918153
6 June 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 931033
15 March 1990 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1223147
4 January 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 930526
6 October 1989 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1331354
25 April 1989 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1340974
6 April 1989 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1348400
14 March 1989 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1197804
6 January 1989 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1195175
27 September 1988 Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 890287
23 September 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 890286
4 March 1988 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1038504
15 December 1987 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1004692
11 December 1987 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1315942
25 February 1987 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1315549
6 November 1986 Hull Examination · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1016065
19 May 1986 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 997531
30 April 1986 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 992120
18 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290813
17 July 1984 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1282153
17 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974123
26 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967727
12 March 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969326

Deficiency record · 142

Lifesaving
Issued 5 July 2001 Resolved
LABEL TOPS OF ALL LIFEJACKET STORAGE LOCKERS NO LATER THAN 13JUL01.
Condition: Unknown
Due 13 July 2001
Resolved 4 October 2001
Lifesaving
Issued 5 July 2001 Resolved
PROVIDE PROOF OF EPIRB REGISTRATION NO LATER THAN 05AUG01.
Condition: Unknown
Due 5 August 2001
Resolved 4 October 2001
Deck/Cargo
Issued 5 July 2001 Resolved
MOUNT ANCHOR NO LATER THAN 05AUG01.
Condition: Unknown
Due 5 August 2001
Resolved 4 October 2001
Construction/Loadline
Issued 5 July 2001 Resolved
REPAIR HIGH BILGE LEVEL SWITCH UNDER GALLEY NO LATER THAN 12JUL01.
Condition: Unknown
Due 12 July 2001
Resolved 4 October 2001
Lifesaving
Issued 5 July 2001 Resolved
PATCH ALL RIPS AND TEARS IN ALL LIFEFLOATS NO LATER THAN 05AUG01.
Condition: Unknown
Due 5 August 2001
Resolved 4 October 2001
Lifesaving
Issued 5 July 2001 Resolved
PROVIDE 9 ADDITIONAL ADULT LIFEJACKETS. VESSEL IS RESTRICTED TO 141 PASSENGERS, 4 CREW, 145 TOTAL UNTIL CORRECTED.
Condition: Unknown
Due 5 July 2001
Resolved 4 October 2001
Documentation
Issued 5 July 2001 Resolved
PROVIDE CPR CERTIFICATION FOR AT LEAST 50% OF THE CREW.
Condition: Unknown
Due 5 August 2001
Resolved 4 October 2001
Engineering
Issued 5 July 2001 Resolved
PROVIDE ADDITIONAL HOSE CLAMPS ON CENTER AND STBD PROPULSION SHAFT PACKING GLANDS NO LATER THAN 13JUL01.
Condition: Unknown
Due 13 July 2001
Resolved 4 October 2001
Navigation
Issued 5 July 2001 Resolved
REPAIR RADAR NO LATER THAN 5AUG01.
Condition: Unknown
Due 5 August 2001
Resolved 4 October 2001
Accommodation/Occupational Safety
Issued 29 March 2001 Resolved
WELD UP CRACKED HANDRAILS PORT SIDE BOW.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Construction/Loadline
Issued 29 March 2001 Resolved
CAP OFF OPEN TUBE TO FOREPEAK COMPARTMENT PORTSIDE.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Accommodation/Occupational Safety
Issued 29 March 2001 Resolved
RE-ATTACH LADDER IN STEERING ROOM.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Electrical
Issued 29 March 2001 Resolved
PROVIDE COVERS FOR FOR COMPRESSOR PRESSURE SWITCHES PORT AND STBD SIDE.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Electrical
Issued 29 March 2001 Resolved
INSTALL TERMINAL COVERS ON BATTERIES FOR STBD GENERATOR AND BATTERIES IN LOWER COMPARTMENT UNDER MAIN PASSENGER COMPARTMENT.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Construction/Loadline
Issued 29 March 2001 Resolved
WELD UP CRACKED GUNWHALES PORT AND STBD BOW.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Construction/Loadline
Issued 29 March 2001 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, RENEW THROUGH HULL PIPES FOR SEWAGE DISCHARGE AND CABIN SINK DISCHARGE.
Condition: Unknown
Due 29 March 2001
Resolved 16 May 2001
Construction/Loadline
Issued 29 March 2001 Resolved
REPAIR/RENEW HATCH DOGS ON FWD ESCAPE HATCH AND MAIN DECK PASSENGER AREA HATCH LEADING TO LOWER AREA.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Engineering
Issued 29 March 2001 Resolved
PROPERLY BRACKET EXHAUST PIPE NEAR AFT ENGINE ROOM HATCH. (BAILING WIRE NOTACCEPTABLE).
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Engineering
Issued 29 March 2001 Resolved
REPACK CENTERLINE PROPULSION SHAFT.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Electrical
Issued 29 March 2001 Resolved
COVER EXPOSED LIGHT BULBS IN ALL COMPARTMENTS.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Electrical
Issued 29 March 2001 Resolved
INSTALL LIGHT BULBS AND COVER ON LIGHT FIXTURE NEAR AFT ENGINE ROOM HATCH.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Electrical
Issued 29 March 2001 Resolved
PROPERLY MOUNT FLOURESCENT LIGHT FIXTURE IN GENERATOR ROOM AND INSTALL LENSE COVER.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Electrical
Issued 29 March 2001 Resolved
CLEAN OIL SOAKED GENERATOR ELECTRICAL WINDINGS ON STBD GENERATOR.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Electrical
Issued 29 March 2001 Resolved
RE-ATTACH PORT GENERATOR JUNCTION BOX TO GENERATOR CASING.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Engineering
Issued 29 March 2001 Resolved
INSTALL MISSING LAGGING ON PORT AND STBD GENERATOR EXHAUST PIPES.
Condition: Unknown
Due 29 March 2001
Resolved 16 May 2001
Electrical
Issued 29 March 2001 Resolved
MAKE PROPER WIRING CONNECTION AT STBD GENERATOR STARTER SOLENOID.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Electrical
Issued 29 March 2001 Resolved
REMOVE NON-MARINE PORTABLE BATTERY CHARGER FROM GENERATOR ROOM.
Condition: Unknown
Due 29 April 2001
Resolved 16 May 2001
Engineering
Issued 7 July 2000 Resolved
Open both air receivers for internal examination.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Lifesaving
Issued 7 July 2000 Resolved
Renew broken antenna on EPIRB.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Accommodation/Occupational Safety
Issued 7 July 2000 Resolved
Renew broken window on starboard side of passenger accommodation space.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Construction/Loadline
Issued 7 July 2000 Resolved
Repair audible alarm for bilge high level alarms.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Construction/Loadline
Issued 7 July 1999 Resolved
Complete installation of bilge high level alarms.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Lifesaving
Issued 10 July 1997 Resolved
RENEW ALL PFD LIGHTS AND WHISTLES.
Condition: Unknown
Due 18 July 1997
Resolved 12 July 1997
Fire Fighting
Issued 10 July 1997 Resolved
RENEW PORTSIDE FIRE HOSE.
Condition: Unknown
Due 15 July 1997
Resolved 12 July 1997
Electrical
Issued 10 July 1997 Resolved
RENEW GENERATOR ANTI-PARALLEL SWITCH BAR.
Condition: Unknown
Due 14 July 1997
Resolved 12 July 1997
Construction/Loadline
Issued 26 November 1996 Resolved
CROP AND RENEW STERN PLATE AT WATERLINE AND UP INCLUDING STARBOARD SIDE FROM STERN FORWARD 4'.
Condition: Unknown
Due 26 November 1996
Resolved 26 November 1996
Construction/Loadline
Issued 26 November 1996 Resolved
CROP AND RENEW INSET AT BOW APPROX 6' DOWN INCLUDING ALL DEFORMED KEEL PLATE.
Condition: Unknown
Due 26 November 1996
Resolved 26 November 1996
Construction/Loadline
Issued 26 November 1996 Resolved
CROP AND RENEW APPROX 43' OF PORT-SIDE SIDE SHELL MID-SHIPS AT WATERLINE AND UP.
Condition: Unknown
Due 26 November 1996
Resolved 26 November 1996
Lifesaving
Issued 11 July 1996 Resolved
NO LATER THAN 11 MARCH 1997, INSTALL ON BOARD IN A FLOAT FREE ARRANGEMENT, A FCC ACCEPTED, CATEGORY 1, 406 EPIRB.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Construction/Loadline
Issued 11 July 1996 Resolved
COMPLETE ALL PREVIOSLY NOTED SIDE SHELL AND STRUCTURAL DISCREPANCIES PRIOR TO 01 NOV 96. VESSEL NOT TO OPERATE WITH PASSENGERS AFTER 01 NOV 96 UNTIL ALL REPAIRS ARE COMPLETED TO THE SATISFACTION OF THE COAST GUARD.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Lifesaving
Issued 11 July 1996 Resolved
INSTALL SOLAS APPROVED LIGHTS ON LIFE PRESERVERS AS NEEDED.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Electrical
Issued 12 June 1996 Resolved
PROPERLY INSTALL MACHINERY GUARDS ON ALL THREE DIESEL ENGINES AND THE PORT GENERATOR.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Construction/Loadline
Issued 3 June 1996 Resolved
PROVIDE A REPAIR PROPOSAL FOR THE INSET SECTION OF THE VSL'S TRANSOM, AS INDICATED BY THE CG MARINE INSPECTOR, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Engineering
Issued 3 June 1996 Resolved
REPLACE THE VESSEL'S STBD TAILSHAFT AND CONDUCT AN UNDERWAY TEST IN THE PRESENCE OF THE USCG.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Construction/Loadline
Issued 3 June 1996 Resolved
PROVIDE A REPAIR PROPOSAL FOR THE INSET AND DAMAGED AREA OF THE VSL'S STBD SIDE SHELL AS INDICATED BY THE CG MARINE INSPECTOR. PROPOSAL SHOULD INCLUDE THE STBD FUEL TANK.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Construction/Loadline
Issued 3 June 1996 Resolved
PROPERLY REPAIR THE SECTION OF WASTED AND HOLED SIDE SHELL PLATING AT THE WATERLINE ON THE STBD SIDE, JUST BELOW THE VESSEL'S PAINTED STRIPE, AND AS INICATED BY THE CG MAIRNE INSPECTOR, PRIOR TO OPERATING WITH PASSNEGERS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Lifesaving
Issued 3 June 1996 Resolved
NO LATER THAN 11 MARCH 1997, INSTALL ON BOARD, IN A FLOAT FREE ARRANGEMENT,A FCC ACCEPTED CATEGORY 1, 406 MHz EPIRB.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Construction/Loadline
Issued 3 June 1996 Resolved
PROVIDE A REPAIR PROPOSAL FOR THE INSET AREA OF THE VESSEL'S BOTTOM IN WAY OF THE FWD PORT SIDE KEEL, AS INDICATED BY THE ATTENDING COAST GUARD MARINEINSPECTOR, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Engineering
Issued 3 June 1996 Resolved
PROVE PROPER OPERATION OF ALL OF THE VSL'S MACHINERY TO THE USCG, TO INCLUDE BOTH GENERATORS, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Electrical
Issued 3 June 1996 Resolved
PROPERLY CLEAN AND REMOVE ALL TRASH AND DEBRIS FROM THE GENERATOR ROOM, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Electrical
Issued 3 June 1996 Resolved
RENEW THE EXHAUST LAGGING ON THE PORT GENERATOR, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Lifesaving
Issued 3 June 1996 Resolved
REMOVE OIL FROM AND CLEAN THE CENTER VOID COMPARTMENT PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Electrical
Issued 3 June 1996 Resolved
REPAIR OR REMOVE THE BARE AND UNUSED ELECTRICAL WIRES AND SWITCHES FROM THEVESSEL'S HYDRAULIC STORAGE TANK IN THE GENERATOR ROOM, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Electrical
Issued 3 June 1996 Resolved
REPLACE THE PORT GENERATOR BATTERY BOX, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Electrical
Issued 3 June 1996 Resolved
CLEAN OIL FROM BOTH GENERATOR BATTERIES, AND PROVIDE WATER CAP FOR THE STBDBATTERY, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Construction/Loadline
Issued 3 June 1996 Resolved
PROVIDE A REPAIR PROPOSAL FOR THE INSET AND DAMAGED AREA OF THE VESSEL'S PORT SIDE SHELL AS INDICATED BY THE CG MARINE INSPECTOR. THIS PROPOSAL SHOULD INCLUDE THE PORT SIDE FUEL TANK.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Engineering
Issued 28 December 1995 Resolved
MAKE VESSEL AVAILABLE FOR UNDERWAY INSPECTION OF STBD SHAFT PRIOR TO 15FEB96.
Condition: Unknown
Due 28 December 1995
Resolved 28 December 1995
Documentation
Issued 8 September 1995 Resolved
PROPERLY POST CERTIFICATE OF INSPECTION ON THE VESSEL.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Construction/Loadline
Issued 8 September 1995 Resolved
PROPERLY REMOVE ALL OIL FROM THE ENGINE ROOM BILGE AND PROVIDE DISPOSAL DOCUMENTATION TO THE USCG.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Construction/Loadline
Issued 8 September 1995 Resolved
PROPERLY REMOVE ALL OIL FROM GENERATOR COMPARTMENT BILGE, AND PROVIDE DISPOSAL DOCUMENTATION TO THE USCG.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 8 September 1995 Resolved
PROPERLY CLEAN OR REPLACE BATTERY IN GENERATOR COMPARTMENT, AND PROPERLY STOW IN AN ADEQUATE BATTERY BOX.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Engineering
Issued 8 September 1995 Resolved
MAKE VESSEL AVAILABLE FOR UNDERWAY INSPECTION OF STBD SHAFT PRIOR TO 15OCT95.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Construction/Loadline
Issued 8 September 1995 Resolved
REPAIR ALL FRACTURES TO THE PORTSIDE HAND RAIL IN WAY OF THE PASSENGER EMBARKATION AREA.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Construction/Loadline
Issued 8 September 1995 Resolved
REPAIR FRACTURE TO THE BOW HANDRAIL ON THE PORTSIDE.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 8 September 1995 Resolved
REMOVE OR PROPERLY SECURE ALL TOOLS, SPARE PARTS, UNUSED MACHINERY AND BUCKETS IN GENERATOR COMPARTMENT.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Lifesaving
Issued 14 July 1995 Resolved
REMOVE ALL TRASH AND UNUSED MATERIALS FROM THE VESSEL AND SECURE ALL GEAR ADRIFT. (46CFR176.25-50(a))
Condition: Unknown
Due 14 July 1995
Resolved 14 July 1995
Lifesaving
Issued 14 July 1995 Resolved
STENCIL ALL LIFEJACKET BOXES.
Condition: Unknown
Due 14 July 1995
Resolved 14 July 1995
Accommodation/Occupational Safety
Issued 14 July 1995 Resolved
PERMANENTLY MOUNT THE HOLDING TANKL FOR VESSEL'S INSTALLED TYPE III MSD.
Condition: Unknown
Due 14 July 1995
Resolved 14 July 1995
Lifesaving
Issued 14 July 1995 Resolved
CONDUCT SATISFACTORY CREW DRILL IN PRESENSE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 14 July 1995
Resolved 14 July 1995
Lifesaving
Issued 14 July 1995 Resolved
PROVE PROPER OPERATION OF ALL MACHINERY, AUXILLARY MACHINERY, GENERATORS, AND ELECTRICAL SYSTEMS.
Condition: Unknown
Due 31 July 1995
Resolved 14 July 1995
Accommodation/Occupational Safety
Issued 14 July 1995 Resolved
MAKE PERMANENT REPAIRS TO THE MEN'S TOILET. VESSEL NOT TO CARRY MORE THAN 49 PASSENGERS, OR VESSEL MAY NOT CONDUCT A VOYAGE OVER 30 MINUTES IN LENGTHUNTIL BOTH TOILETS ARE OPERATIONAL.
Condition: Unknown
Due 31 July 1995
Resolved 19 July 1995
Lifesaving
Issued 14 July 1995 Resolved
REMOVE UNUSED OIL STORAGE TANK FROM ENGINE ROOM AT NEXT DRYDOCK EXAM.
Condition: Unknown
Due 14 July 1995
Resolved 14 July 1995
Fire Fighting
Issued 14 July 1995 Resolved
PROVIDE ADAQUATE NUMBER OF SERVICED FIRE EXTINGUISHERS TO MEET THE REQUIREMENTS OF THE C.O.I.
Condition: Unknown
Due 31 July 1995
Resolved 19 July 1995
Lifesaving
Issued 14 July 1995 Resolved
REPLACE RETRO REFLECTIVE TAPE ON ALL (3) LIFE FLOATS.
Condition: Unknown
Due 31 July 1995
Resolved 14 July 1995
Lifesaving
Issued 14 July 1995 Resolved
STENCIL ALL LIFERINGS.
Condition: Unknown
Due 31 July 1995
Resolved 14 July 1995
Lifesaving
Issued 14 July 1995 Resolved
REPLACE/REPAIR DAMAGED LIFE-FLOAT.
Condition: Unknown
Due 14 July 1995
Resolved 14 July 1995
Fire Fighting
Issued 14 July 1995 Resolved
REPLACE STRUCTURAL FIRE PROTECTION IN ENGINE ROOM, ON THE PORT SIDE, PRIOR TO ANY INTERNATIONAL VOYAGE.
Condition: Unknown
Due 31 July 1995
Resolved 14 July 1995
Electrical
Issued 14 July 1995 Resolved
PROPERLY LABEL ALL CIRCUIT BREAKER BOXES.
Condition: Unknown
Due 31 July 1995
Resolved 19 July 1995
Lifesaving
Issued 14 July 1995 Resolved
PROVIDE ADAQUATE TYPE AND NUMBER OF PYROTECHNIC DISTRESS SIGNALS, IN ANA APPROVED CONTAINER TO MEET THE REQUIREMENTS OF 46CFR.
Condition: Unknown
Due 31 July 1995
Resolved 14 July 1995
Documentation
Issued 14 July 1995 Resolved
POST STABILITY LETTER ON THE VESSEL.
Condition: Unknown
Due 31 July 1995
Resolved 14 July 1995
Documentation
Issued 14 July 1995 Resolved
POST C.O.I. ON VESSEL.
Condition: Unknown
Due 31 July 1995
Resolved 19 July 1995
Construction/Loadline
Issued 14 July 1995 Resolved
PROVIDE HANDLE FOR EMERGENCY GENERATOR ROOM HATCH.
Condition: Unknown
Due 31 July 1995
Resolved 19 July 1995
Engineering
Issued 14 July 1995 Resolved
DETERMINE SOURCE OF OIL LEAK ON THE STBD ENGINE AND MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 31 July 1995
Resolved 14 July 1995
Engineering
Issued 14 July 1995 Resolved
PROVIDE VENT COVERS FOR ENGINE ROOM INTAKES.
Condition: Unknown
Due 31 July 1995
Resolved 14 July 1995
Lifesaving
Issued 14 July 1995 Resolved
PROVIDE ADAQUATE NUMBER OF SERVICABLE LIFE JACKETS IN ORDER TO MEET THE REQUIREMENTS OF THE C.O.I.
Condition: Unknown
Due 31 July 1995
Resolved 19 July 1995
Electrical
Issued 14 July 1995 Resolved
REMOVE UNUSED ELECTRICAL CABLE FOR THE STOVE IN THE FWD CREW COMPARTMENT.
Condition: Unknown
Due 14 July 1995
Resolved 14 July 1995
Documentation
Issued 14 July 1995 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING PROGRAM I.A.W. 46 CFR PART 16.
Condition: Unknown
Due 31 July 1995
Resolved 14 July 1995
Documentation
Issued 14 July 1995 Resolved
POST PASSENGER SHIP SAFETY CERTIFICATE ON THE VESSEL.
Condition: Unknown
Due 31 July 1995
Resolved 19 July 1995
Navigation
Issued 14 July 1995 Resolved
PROPERLY SECURE THE STEERING SYSTEMS TIE-ROD/RAM CONNECTION, WITH DOUBLE NUT OR CODDER PIN.
Condition: Unknown
Due 31 July 1995
Resolved 19 July 1995
Lifesaving
Issued 14 July 1995 Resolved
REPLACE WASTED NET IN LIFEFLOAT.
Condition: Unknown
Due 14 July 1995
Resolved 14 July 1995
Lifesaving
Issued 14 July 1995 Resolved
Vessel capacity reduced by 22 passengers until additional lifefloat is placed aboard. (150-22=128 passengers)
Condition: Unknown
Due 31 July 1995
Resolved 20 July 1995
Lifesaving
Issued 14 July 1995 Resolved
RESTENCIL ALL FOUR (4) BUOYANT APPARATUS._x001C_
Condition: Unknown
Due 31 July 1995
Resolved 14 July 1995
Documentation
Issued 14 July 1995 Resolved
POST THE EMERGENCY INSTRUCTIONS IN THE PASSENGER AREA.
Condition: Unknown
Due 31 July 1995
Resolved 14 July 1995
Electrical
Issued 20 June 1995 Resolved
prior to next inspection for certification, have vessel's electrical systemsurveyed by a marine surveyor, provide report to the Coast Guard and conduct appropriate repairs.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Construction/Loadline
Issued 20 June 1995 Resolved
At the next drydock, make the following areas available for internal inspection by temporarily removing the structural fire protection insulation: (1) E/R, fwd in way of blkd stbd side (2) In way of stern corners in lazerette.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Engineering
Issued 20 June 1995 Resolved
Clean all sea strainers on main diesel engines (3).
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Engineering
Issued 20 June 1995 Resolved
Clean internal valve seatings of marine growth.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Construction/Loadline
Issued 20 June 1995 Resolved
Gauge hull in area of set in on port side below waterline at next drydock on forward third of hull.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Construction/Loadline
Issued 20 June 1995 Resolved
Repair cracked welds on stringer and frame in mid body compartment on stbd side, marked by CG inspector.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Construction/Loadline
Issued 20 June 1995 Resolved
Remove all "bondo" from hull in way of set in on port side forward prior togauging at next drydock.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Construction/Loadline
Issued 20 June 1995 Resolved
Repair properly, two improper inserts at the waterline on port side in way of engine room.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Engineering
Issued 20 June 1995 Resolved
Replace three propellers due to cracking throughout.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Accommodation/Occupational Safety
Issued 25 May 1995 Resolved
Close overboard discharge valves to the Marine Sanitation Device (MSD). Maintain MSD valves in a closed position while within 3 miles of a U.S. shoreline.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Navigation
Issued 19 May 1995 Resolved
REPAIR NUMEROUS HYDRAULIC FLUID LEAKS FOR STEERING SYSTEM.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Electrical
Issued 19 May 1995 Resolved
REPAIR STARBOARD GENERATOR TO OPERABLE CONDITION. DEMONSTRATE PROPER OPERATION OF GENERATOR IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR PRIOR TO PLACING IT IN OPERATION.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Construction/Loadline
Issued 19 May 1995 Resolved
CLEAN BILGES, MIDDLE COMPARTMENT (FORWARD OF ENGINE ROOM) FOR INSPECTION BYMARINE INSPECTOR._x001C_
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Accommodation/Occupational Safety
Issued 19 May 1995 Resolved
PROVIDE HANDLE FOR ENGINEROOM EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Navigation
Issued 19 May 1995 Resolved
REPAIR EXCESSIVE LEAKING OF PORT RUDDER POST.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Construction/Loadline
Issued 19 May 1995 Resolved
VERIFY ACCURACY OF DRAFT MARKS PRIOR TO RE-PAINTING.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Electrical
Issued 19 May 1995 Resolved
RE-ROUTE WIRING FROM BILGES OF GENERATOR COMPARTMENT TO BE AS HIGH ABOVE BILGES AS PRACTICABLE._x001C_
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Construction/Loadline
Issued 19 May 1995 Resolved
REPAIR FRACTURED WELD AT FLOOR/FRAME CONNECTION, PORT SIDE IN OLD AIR CONDITIONER SPACE.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Construction/Loadline
Issued 19 May 1995 Resolved
REPAIR FRACTURED WELD, 4TH LONGITUDINAL AT FORWARD BULKHEAD, SEWAGE TANK COMPARTMENT, STARBOARD SIDE._x001C_
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Fire Fighting
Issued 19 January 1995 Resolved
Repair and prove proper operation of vessels fire pumps prior to carrying passengers for hire.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Construction/Loadline
Issued 19 January 1995 Resolved
Properly remove accumulated oil that has drained into the bilge of the vessel. Pollution ticket # 00016221 issued 19JAN95.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Lifesaving
Issued 19 January 1995 Resolved
Properly remove all buckets of used engine oil from the vessel.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Lifesaving
Issued 19 January 1995 Resolved
Properly mark all buoyant apparatus with vessels name and capacity.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Fire Fighting
Issued 19 January 1995 Resolved
Service and properly locate portable fire extinguishers.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Construction/Loadline
Issued 21 December 1994 Resolved
MAKE PROPER REPAIRS TO BOTTOM HULL PER APPROVED PLANS, ALL REPAIRS ARE TO BE IN ACCORDANCE WITH GOOD MARINE PRACTICE. ALL REPAIRS ARE TO BE APPROVEDAND INSPECTED BY LOCAL COAST GUARD INSPECTION OFFICE.
Condition: Unknown
Due 21 December 1994
Resolved 21 December 1994
Construction/Loadline
Issued 17 November 1994 Resolved
Properly remove all oil and diesel fuel from bilges and provide the Coast Guard with documentation of the proper removal.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Lifesaving
Issued 17 November 1994 Resolved
Provide a SOLAS approved light for each PFD on board before sailing on an international voyage.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Lifesaving
Issued 17 November 1994 Resolved
Remove used oil stored in the engine room and crew area.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Engineering
Issued 17 November 1994 Resolved
Repair diesel fuel leak in engine room.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Construction/Loadline
Issued 5 May 1994 Resolved
SUBMIT REPAIR PROPOSAL FOR REPLACEMENT OF IMPROPER REPIARS TO HULL NOTED DURING DRYDOCK INSPECTION COMPLETED ON MAY 5, 1994. PENDING ACCEPTANCE OF PROPOSAL THE IMPROPER REPAIRS MUST BE VISUALLY INSPECTED EVERY SIX MONTHS AND A REPORT ON THEIR CONDITION SUBMITTED TO THE COAST GUARD BY THE MASTER.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Engineering
Issued 14 May 1992 Resolved
VESSEL'S COOLING SYSTEM FAILED ON THE PORT ENGINE DUE A RUPTURED HOSE. SUBEQUENTLY, THE HEAD ON THE ENGINE CRACKED. ENGINE NOTED TO BE INOPERABLEUPON INSPECTION.
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Documentation
Issued 15 April 1992 Resolved
PROVIDE PROPOSAL FOR PRE-EMPLOYMENT, POST CASUALTY, REASONABLE CAUSE, AND RANDOM DRUG TESTING.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Electrical
Issued 18 June 1990 Resolved
PROVIDE GLOBES FOR ALL ELECTRICAL LIGHTS IN THE ENGINE ROOM.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Engineering
Issued 6 June 1990 Resolved
COMPLETE COAST GUARD FORM CG-2692 AND MAIL TO THIS OFFICE WITH INFORMATION CONCERNING LOSS OF CENTER LINE MAIN DIESEL ENGINE.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Engineering
Issued 6 June 1990 Resolved
REPAIR CENTER LINE MAIN DIESEL ENGINE AND HAVE THE COGNIZANT [name withheld] TEST ON THE REPAIRED ENGINE.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Lifesaving
Issued 6 June 1990 Resolved
PROPERLY INSTALL THE LIFE FLOATS LOCATED ON THE BOW TO A POSITION AFT OF THE WHEEL HOUSE. THE RAFTS SHALL BE SECURED PROPERLY, USING GOOD MARINE PRACTICES. THE INSTALLATION SHALL BE WITNESSED BY THE COGNIZANT OCMI.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Accommodation/Occupational Safety
Issued 15 March 1990 Resolved
REPAIR TO MAKE OPERATIONAL, THE MALE HEAD. ENSURE THAT THE HEAD IS PROPERLY INSTALLED TO THE MARINE SANITATION DEVICE (MSD).
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Electrical
Issued 15 March 1990 Resolved
REPAIR THE FIXED EMERGENCY LIGHTING SYSTEM THROUGHOUT THE VESSEL. ENSURE THAT EMERGENCY LIGHTS WORK IN ALL SPACES INCLUDING THE GENERATOR ROOM AND ENGINE ROOM.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Construction/Loadline
Issued 4 January 1990 Resolved
INSTALL NEW GASKETS IN THE WATERTIGHT DOOR AND THE MAIN DECK HATCHES.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Construction/Loadline
Issued 4 January 1990 Resolved
HOSE TEST MAIN DECK HATCHES AND WATERTIGHT DOOR TO DETERMINE EXTENT OF WATERTIGHT INTEGRITY.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Construction/Loadline
Issued 4 January 1990 Resolved
CLEAN ALL RESIDUAL FUEL FROM FOREPEAK TANK.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Construction/Loadline
Issued 4 January 1990 Resolved
REINSTALL STANCHIONS IN ENGINEROOM AT FORWARD PORTION OF DECK HATCH OPENING
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Lifesaving
Issued 23 September 1988 Resolved
PROPERLY INSTALL LIFERAFTS AND PROPERLY ATTATCH PAINTERS
Condition: Unknown
Due 23 September 1988
Resolved 23 September 1988
Lifesaving
Issued 23 September 1988 Resolved
REPLACE TWO WORN RING LIFE BUOYS
Condition: Unknown
Due 23 September 1988
Resolved 23 September 1988
Electrical
Issued 30 April 1986 Resolved
REWELD PORT GENERATOR EXHAUST BRACKET.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Construction/Loadline
Issued 30 April 1986 Resolved
INSTALL DOG ON WTD TO ACCOMIDATION SPACE.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Engineering
Issued 30 April 1986 Resolved
WELD STARBOARD EXHAUST THRU HULL CONNECTION.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Fire Fighting
Issued 17 February 1984 Resolved
PROVIDE APPROVED FIRE EXTINGUISHER MOUNTING BRACKETS AS PER NAME PLATE DATA ON EXTINGUISHER.
Condition: Unknown
Due 17 February 1984
Resolved 17 February 1984
Unknown
Issued 17 February 1984 Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE M/V HENRY D, O.N. DN549541.
Condition: Unknown
Due 17 February 1984
Resolved 17 February 1984

Casualty record · 1

7 April 2002Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2464142
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record