← All vessels
MONICA P
MONICA P is a 1998 freight ship. The Coast Guard has recorded 16 inspections since 1998, most recently in June 2017, along with 21 deficiencies and 3 operational controls.
Records from 1998 to 2017. Most recent: inspection, 3 June 2017.
- Built
- 1998
- Last inspected
- 3 June 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 21 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9179218 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELVP4
475850
Flag
LIBERIA
—
Maury page id
psix-475850
Inspections, by type
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it27011 - Convention (Subpart B), Gross Ton
16011 - Convention (Subpart B), Net Ton
46667 - Dead Weight, Metric Ton
54446 - Displacement, Metric Ton
16011 - Convention (Subpart B), Net Ton
46667 - Dead Weight, Metric Ton
54446 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
3 June 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6164237
21 April 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6129471
14 April 2017
NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6119604
29 October 2015
COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5748483
2 March 2014
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4805129
11 February 2012
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4234548
16 December 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3897478
28 July 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3547314
24 July 2009
NPV Safety Exam · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3544603
5 February 2009
ISPS III Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3412777
13 August 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3283930
26 May 2006
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2659556
24 July 2003
Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1855704
17 August 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 431740
20 February 1999
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 425819
4 June 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 417087
Deficiency record · 21
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 14 April 2017
Resolved
1599- Other (Navigator)-All ships 300GT and upwards shall be fitted with speed and distance measuring device to indicate speed and distance through water. PSCO observed that speed log was inoperable. 74Solas (97) V/19.2.3.4 17b
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 14 April 2017
Resolved
1599- Other (Navigator)-Whenever a defect is discovered which affects the completeness of its life saving appliances or other equipment the master or owner shall report to the administration. PSCO discovered that the ship came into port without notifying the CG or Administration. 74Solas (97) Reg. 11(c) 17b
Fire Fighting › Fire Main › Condition
Issued 14 April 2017
Resolved
0799-Other (Firefighting equipment)-Firefighting equipment shall be kept in good working order and be available for immediate use at all times. PSCO observed a hole in the fire main forward of the NR 1 cargo hold and leaks in the fire main on the starboard side forward of the NR 4 cargo hold. 74 SOLAS (97) II-2/Reg. 2150b
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 14 April 2017
Resolved
0799-Other (Firefighting equipment)-the function of the detection system shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air at the appropriate temperature. PSCO observed ship’s crew attempting to use a cigarette lighter to test heat detector. 74 SOLAS (97) II-2/13.1.13 50b
Lifesaving › Lifeboat › Propulsion Transmission
Issued 2 March 2014
Resolved
0610- lifeboat- Before the ship leaves port and at all times during the voyage all life-saving appliances shall be in working order and ready for immediate use. Starboard side lifeboat coad not go ahead or astern. 74 SOLAS (97 Cons) Chapter III Reg 19.2
Engineering › Fuel Oil Service System › Filter
Issued 2 March 2014
Resolved
0945- -The machinery, boilers, and other pressure vessel associated piping systems and fitting shall be of a design and consturction adequate for the service for whihc that are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. The fuel filter on the emergency generator was leaking. 74SOLAS (97 CONS) Chapter II-1 Reg 26.1
Deck/Cargo › Holds/Tanks › Weathertight Door
Issued 11 February 2012
Resolved
Both exterior access doors on B deck wasted and holed. The company should ensure that apprpriate corrective action is taken. Means of access to crew accomdation shall ensure adequate protection against weather and sea. SOLAS 2009 Chapter IX Regulation 3.1 / ISM Code 10.2.3 / ILO 147 P. 33-1
Action Taken: 40 AC
Construction/Loadline › Structures › Door
Issued 5 February 2009
Resolved
1270; Both doors leading into the forward Bos'n stores are not water tight. SEC Hampton issued a requirement for starboard door in August 08. New O/O have taken over the vessel and were unaware of this requirement. The deficiency was re-issued for Class must come on and inspect these doors prior to the vessels departure.
Lifesaving › Lifebuoys › Serviceable
Issued 5 February 2009
Resolved
0650; There were several lifebuoys that were damaged and holed. In addition the starboard lifeboat is missing reflective tape and the windows are faded making them hard to see out. Lifesaving plan is missing the location of the L/J and immersion suits in the fwd Bos'n store, SOLAS training manual is missing and the instructions for launching the lifeboats are incorrect, Class needs to address.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 5 February 2009
Resolved
2040; The Voyage Plan was not completely filled out prior to the ship's arrival. Areas that were required to be marked no-go were not marked, tides and currents were not calculated out, and major navigational markings were not listed to name a few. Class must inspect the outbound voyage plan to ensure the crew is following their SMS procedures for safe navigation as per SOLAS 97 V/34.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 5 February 2009
Resolved
0900: There is no documentation on board that indicates the voltage rating of the electrical switchboard matting being used throughout the vessel. Some of the matting is missing or worn out. The company must provide documentation that the electrical matting on board is meets the SOLAS requirements and missing matting must also be replaced.
Engineering › Steering Gear System › Trick Wheel
Issued 5 February 2009
Resolved
0936: There is no non-slip surface between the engine room door to the steering control unit. The crew needs to install some type of walkway.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 5 February 2009
Resolved
0330: The sewage treatment plant is not being maintained as per the manufacturers requirements. Daily, weekly, monthly, semi annual and annual test are not being carried out. In addition the crew does not have a chlorine test kit on board to determine the chlorine content of the tank.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 5 February 2009
Resolved
2055: The following items were noted during the inspection of the ship's Ballast Water Management Plan. Crew training has not been carried out, sample points have not been identified, sediment documentation has not been recorded and the ballast water handling log form has not been filled out.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 5 February 2009
Resolved
2055; The Garbage Management Plan is not being followed by the crew. The color coding of the cans throughout the vessel do not match what is listed in the plan, mixed garbage was found in all of the cans on the vessel and the starting, stopping, latitude and longitude has not been recorded in the garbage log when items were incinerated.
Fire Fighting › Firemans Outfit › Lifeline
Issued 13 August 2008
Resolved
One lifeline is worn and partially parted. Fireproof lifeline will not withstand the required static load of 3.5 KN for 5 minutes without failure. Recitfy to the satisfaction of the USCG. FSS CODE 3/2.1.3. SOLAS 2004 CONS. II-2/ 10.1
Construction/Loadline › Structures › Door
Issued 13 August 2008
Resolved
Port side Bosun door at forecastle is not weathertight. At least 1/2 inch daylight can be seen when door is closed. Steel on bulkhead appears to be wasted to the point that the clamping devices proove ineffective.
Operations/Management › Drills/Instruction › Fire
Issued 26 May 2006
Resolved
Vsl drills fire/abandonship were not sufficiently conducted. Vsl crew to train and prepare for drills only on 31MAY06
Personnel › Training
Issued 24 July 2003
Resolved
Fire drill was not conducted in a timely and efficient manner. LEGACY COMPONENT DESC: Fire Fighting Basic
Personnel › Training › Proficiency in Survival Craft
Issued 24 July 2003
Resolved
Abandon ship drill was not performend in atimely and efficient manner.
Navigation
Issued 20 February 1999
Resolved
Vessel's number 2 radar unit was inoperable when vessel entered port. Vessel received letter of deviation to enter.