Records from 2013 to 2026. Most recent: inspection, 18 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 21
18 May 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8375295
16 June 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8160043
10 March 2025
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8090856
13 May 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7909830
15 May 2023
Annual Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7689028
6 February 2023
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7632424
15 December 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7609784
19 April 2022
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7434184
20 May 2021
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7201626
30 November 2020
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7103370
13 July 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7004808
19 June 2019
DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6718763
27 November 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6587214
15 November 2018
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6580754
1 June 2018
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6431653
21 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6419890
2 November 2017
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6299671
20 April 2017
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6128460
14 November 2016
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6040912
29 August 2016
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5986157
28 April 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5864417
01 - Certificates & Documentation › 011 - Ships Certificates › Operational Limitations for Passenger ships
Issued 18 May 2026
Resolved
"A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant." MI obserfved 02 expired handheld orange smokes. Restricted to daylight operations until rectified.
46CFR180.68(b)
Action required: 705 - Other - as specified
Resolved 20 May 2026
Resolution: Recieved picture via email of new flares 3 orange 3 red.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 18 May 2026
Resolved
"The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly related to the incident." MI observed expired alcohol swabs. Replace within 14 days.
46 CFR 4.06-3
46 CFR 185.212
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2026
Resolved 21 May 2026
Resolution: Recieved photo via email of new alcohol test strips.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 May 2026
Resolved
"Electrical equipment on a vessel must be installed and maintained to... Minimize accidental personnel contact with energized parts..." MI observed 12V breaker panel on bridge with improperly fitting blank covers exposing breaker internals. Rectify within 30 days.
46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2026
Resolved 8 June 2026
Resolution: recieved photo via email of new blanks on breaker panel
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 March 2025
Resolved
Repair the upper deck, portside mooring cleat.
Prior to Credit ddx
Action required: 705 - Other - as specified
Resolved 27 March 2025
Resolution: Vessel repaired the second deck mooring cleat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 December 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years (46 CFR 176.600(c)(1)) (701C)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2022
Resolved 27 February 2023
Resolution: All drydock items have been made available for inspection and inspected. All sat with exception of 2 defs that remain outstanding from activity 7632424.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 20 May 2021
Resolved
A vessel must have onboard that vessel the orignial Certifcate of Documentation currently in effect for that vessel. Vessel does not have COD onboard.
Rectify w/in 7 days
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 2 July 2021
Resolution: Operator submitted picture of DOC onboard
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 May 2021
Resolved
Suitable covers, guard, or rails shall be installed in way of all exposed gears, machinery, etc. Main engine not installed with guards.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 2 July 2021
Resolution: Operator submitted picture of machinery guards installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 May 2021
Resolved
Vessel is required to have ground fault detection.
46 CFR 183.10-30
Rectify by next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2022
Resolved 27 February 2023
Resolution: Ground detection has been installed in engine room electrical panel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2020
Resolved
EMPLOYERS MUST MAINTAIN RECORDS OF CHEMICAL TESTS AND MUST MAKE THESE RECRODS AVAILABLE TO COAST GUARD OFFICIALS UPON REQUEST. CURRENT DAPI PROGRAM ON VESSEL NEEDS TO BE UPDATED FOR 2020, INCLUDING PROOF OF ENROLLMENT IN CONSORTIUM.
46 CFR 16.260
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2019
Resolved
46 CFR 182 - port and stbd shaft seals excessively leaking
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
Resolution: MI verified that the shaft seals were not leaking excessively, both not engaged and while engaged.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2019
Resolved
46 CFR 183 - Plastic clasps in E/R for wire bundling
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 June 2019
Resolved
46 cfr 180 - Unserviceable LF, 9 adult, and 6 child PFDs. 4 life rings need retro tape and spliced line. 2 light floats did not illume.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: Life float removed, life jackets were replaced, ring life buoys were re-taped and had the lines spliced, and the floating water lights were operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2019
Resolved
46 CFR 183 - Install junction boxes at connection points (flaot switches, audio equipment)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2019
Resolution: The float switch connections were placed into junction boxes, as was the connection for lighting/speakers. the DJ equipment was disconnected until it could be hardwired in.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 June 2019
Resolved
33 CFR 84 - Anchor light out
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
Resolution: MI verified that the anchor light was operational.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 June 2019
Resolved
46 CFR 176 - Broken glass window pilothouse door
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 July 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 June 2019
Resolved
46 CFR 183 - E lights did not illume when in dead ship condition
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: MI verified that the E lights activated when power supply to the vessel was interrupted.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 June 2019
Resolved
46 CFR 184 - Update charts regularly
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 June 2019
Resolution: Crew member will be assigned to conduct routine checks. Additionally, the O/O purchased a new, up to date chart that was verified as being on the vessel 24JUN2019 by attending MI's.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 June 2019
Resolved
46 CFR 176 - Fire extinguisher obstructed on upper deck
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 19 June 2019
Resolution: Relocated
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 June 2019
Resolved
46 CFR 67 - COD/COI not updated with new owner. COD application submitted, backlogged due to furlough.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: A new COD was applied for by the O/O. Application emailed to MI.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 June 2019
Resolved
46 CFR 182 - Bilge alarm inaudible in pilothouse
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: New alarm/float switch installed and operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 June 2019
Resolved
Vessel was found operating outside of COI with passengers onboard. Vessel had 835 notating that the vessel was to not get underway with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 November 2018
Resolved
Vsl is not broadcasting a Call Sign and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 April 2022
Resolution: Verified proper opreation of AIS.
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 21 May 2018
Resolved
Marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Curtains in galley in front of ovens shall not be present while underway or when galley is in service.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2018
Lifesaving › Hand Flares › Expired
Issued 21 May 2018
Resolved
A vessel on rivers route must carry 03 hand red flare distress signals and 03 hand orange smoke signals. Remove expired flares, carry appropriate number of required flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2018
Lifesaving › Hand Flares › Storage
Issued 21 May 2018
Resolved
Portable watertight flares for distress flares and smoke signals shall be clearly marked in legible contrasting letters at least .5" high: DISTRESS SIGNALS.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2018
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 21 May 2018
Resolved
All electrical equipment must be clearly marked and identified. Clearly label or replace out of service switches on operating station distribution panel w/ blanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2018
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 April 2017
Resolved
Certificate of Documentation was missing and not on board.
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 27 April 2017
Resolution: Owner provided documentation showing that a new Certificate of Documentation had been applied for and furnished a temporary certificate/proof of pending application.
Lifesaving › Lifebuoys › Serviceable
Issued 20 April 2017
Resolved
Two ring buoys were no longer serviceable and required replacement (Aft and Port Side)
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 27 April 2017
Resolution: Two ring buoys were replaced.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 April 2017
Resolved
Renew retroreflective material on child lifejackets.
Due 27 April 2017
Resolved 27 April 2017
Resolution: Retro was renewed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 April 2017
Resolved
Ensure proper placard is posted for types of child lifejackets on board.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 27 April 2017
Resolution: Type of child lifejackets which did not have a corresponding placard were in excess of what was required and were removed from the vessel.
Lifesaving › Lifefloat › Serviceable
Issued 20 April 2017
Resolved
EPIRB and life floats were not properly serviced or installed correctly. These two items are not required per the COI and can either be removed or serviced.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 27 April 2017
Resolution: EPIRB and life floats were removed from the vessel.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 April 2017
Resolved
Make bulkhead watertight where port engine exhaust penetrates bulkhead.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 27 April 2017
Resolution: Penetration was made watertight.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 14 November 2016
Resolved
Exhuast present in lazarette after sea trials were conducted. Gave 7 days to ID and present repair proposal.
Condition: Improper/Lack of Maintenance
Due 21 November 2016
Resolved 28 November 2016
Resolution: Attended vessel for purpose of clearing deficiency; attested to proper repair of M/E exhaust.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 17 October 2016
Resolved
Conduct sea trials and examine starboard side exhaust piping while underway.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2016
Resolution: Conducted sea trials- all SAT. Exhaust fumes found in lazarette.
Engineering › Bilge Water Management System › Piping
Issued 17 October 2016
Resolved
Test bilge suction from tank space (just aft of ER) and lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2016
Resolution: Bilge pump tested- all SAT.
Fire Fighting › Fire Pumps › Arrangement
Issued 29 August 2016
Resolved
Test Fire Main System.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2016
Resolution: Tested fire main- all SAT.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 28 April 2016
Resolved
Provide valid FCC Radio Safert Certificate.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 29 April 2016
Resolution: Received copy of FCC Radio Safety Certificate
Communications › Radio Communications › VHF Radiotelephone
Issued 28 April 2016
Resolved
Install approved DSC VHF radio
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 29 April 2016
Resolution: Received proof of purchase and install.
Navigation › Piloting/Steering › Marine Charts
Issued 28 April 2016
Resolved
KK04 - Provide updated charts.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 29 April 2016
Resolution: Received proof of purchase.
Operations/Management › Passenger Operations › Safety Orientation
Issued 28 April 2016
Resolved
KK05 - Provide safety orientation in accordance w/ 46CFR185.25-1(d)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 28 April 2016
Resolution: Corrected on the spot.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 April 2016
Resolved
KK06 - Provide repair proposal for aft engine room bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 6 May 2016
Resolution: Received repair proposal from North River Shipyard. Repairs must be complete before receiving credit drydock in August 2016.