MAURY USCG vessel records Sign in
← All vessels

GOOD TIMES

GOOD TIMES is a 1973 passenger vessel (uninspected). The Coast Guard has recorded 59 inspections since 1980, most recently in September 2015, along with 122 deficiencies.

Records from 1980 to 2015. Most recent: inspection, 25 September 2015.

Built
1973
Last inspected
25 September 2015
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD5720
Flag
UNITED STATES
366028000, 367162560 (licence lapsed)
Maury page id
psix-47594

Inspections, by type

…with no type recorded7
Years with a record 28 calendar years (1980–2015)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.8 ft × 17.0 ft × 7.3 ft
Registered tonnagegross 38 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROSE CRAFT BOAT WORKS · HARKERS ISLAND, NC, UNITED STATES · built 1973
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 14 September 2011
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD5720MMSI 367162560 · expired · compulsorily equipped · granted 25 January 2007, cancelled 1 April 2017
WCX3422MMSI not assigned · expired · compulsorily equipped · granted 25 March 1997, cancelled 27 May 2007
WAI9241MMSI 366028000 · expired · compulsorily equipped · granted 28 July 1994, cancelled 2 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 59

25 September 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5728579
15 March 2010 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3688399
26 February 2010 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3694941
3 December 2009 Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3644644
26 March 2009 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3440096
5 March 2009 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3427946
9 February 2009 Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3414520
26 March 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3168928
26 February 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3140097
16 March 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2889144
5 March 2007 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2880696
15 February 2007 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2872489
10 April 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2620888
12 December 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2550131
7 April 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2423969
21 March 2005 Internal Structural Exam · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2315962
15 March 2005 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2310335
23 April 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2051040
27 February 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2014380
19 February 2004 In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1993767
21 April 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1798378
20 March 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1758868
27 February 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1729985
15 February 2002 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1488606
25 September 2001 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1073472
6 September 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1073486
28 March 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1060016
26 March 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1060011
26 March 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1376521
10 April 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1048867
17 February 1999 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445424
22 September 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 803816
6 March 1998 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1364678
25 August 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1380978
25 April 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1396715
19 February 1997 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1107390
16 December 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1461754
19 August 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 842795
19 August 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1263023
15 March 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404105
31 July 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 875590
3 April 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1431501
10 February 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1458212
7 April 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 852947
7 April 1994 Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 856129
8 March 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 838473
26 February 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151062
18 February 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151060
5 September 1991 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1253449
22 March 1989 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1341164
31 May 1988 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 891718
23 September 1987 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1011317
23 June 1987 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1011310
16 June 1986 COI Inspection · Credit Drydock
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1307884
30 March 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1275978
23 March 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1271965
24 February 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 965844
10 December 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1278370
7 March 1980 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274848

Deficiency record · 122

Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 15 March 2010 Resolved
Provide and install fuel shut off valves at both main engines and generator.
Action required: 705 - Other - as specified
Due 15 April 2010
Resolved 13 April 2010
Resolution: Shut off valves were installed at both main engines and at generator as required and found to be satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2010 Resolved
Remove dead end wires located on fwd bulkhead in engine room by dead ending into a junction box or completely removing.
Action required: 705 - Other - as specified
Due 15 April 2010
Resolved 13 April 2010
Resolution: Master removed dead end wires as required and found to be in satisfactory condition.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 15 March 2010 Resolved
Replace deteriorated oil pressure sensor line coming from starboard engine in way of oil leak.
Action required: 705 - Other - as specified
Due 15 April 2010
Resolved 13 April 2010
Resolution: Oil pressure sensor line was replaced as required and found in satisfactory condition.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 March 2010 Resolved
Provide 3rd party servicing report for fixed fire system.
Action required: 705 - Other - as specified
Due 15 April 2010
Resolved 13 April 2010
Resolution: Received satisfactory 3rd party servicing report of fixed fire system.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 15 March 2010 Resolved
Provide updated navigation publications.
Action required: 705 - Other - as specified
Due 15 April 2010
Resolved 13 April 2010
Resolution: Updated pubs were provided as required.
Engineering › Bilge Water Management System › Not Operational
Issued 15 March 2010 Resolved
Prove proper operation of engine room bilge pump indicator light.
Action required: 705 - Other - as specified
Due 15 April 2010
Resolved 13 April 2010
Resolution: Upon operation of bilge pump, indicator light was witnessed on bridge and found to be satisfactory.
Engineering › Bilge Water Management System › Not Operational
Issued 15 March 2010 Resolved
Remove paint from bilge high level alarm lights in wheel house.
Action required: 705 - Other - as specified
Due 15 April 2010
Resolved 13 April 2010
Resolution: Paint was removed from visual indicators as required and found to be in satisfactory condition.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 15 March 2010 Resolved
Provide and install rails for ladder leading to wheel house.
Action required: 705 - Other - as specified
Due 15 April 2010
Resolved 13 April 2010
Resolution: Ladder handles were installed as required.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 9 March 2009 Resolved
Provide valid FCC Safety Radio Telephony Certificate per 46 CFR 184.502.
Action required: 705 - Other - as specified
Due 9 April 2009
Resolved 26 March 2009
Resolution: The vessel had onboard a FCC safety radio certificate.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 March 2009 Resolved
Replace expired battery in waterlight on lifefloat per 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 9 April 2009
Resolved 26 March 2009
Resolution: The expired batteries were replaced in the water light.
Electrical › Electric Supply System (service) › Battery Charger
Issued 9 March 2009 Resolved
Clean port and stbd alternators of used motor oil per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 9 April 2009
Resolved 26 March 2009
Resolution: Both the port and starboard alternators were cleaned.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 March 2009 Resolved
Repair fuel leak on stbd fuel oil tank per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 9 April 2009
Resolved 26 March 2009
Resolution: The leak on the starboard fuel tank was repaired.
Engineering › Fuel Oil Service System › Filter
Issued 9 March 2009 Resolved
Repair leak on port fuel oil filter per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 9 April 2009
Resolved 26 March 2009
Resolution: The leak on the port fuel filter was secured.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 March 2009 Resolved
Provide and install lagging on port and stbd engines per 46 CFR 182.20-15.
Action required: 705 - Other - as specified
Due 9 April 2009
Resolved 26 March 2009
Resolution: Lagging was properly installed on the port engine exhaust.
Engineering › Lubricating Oil Service System › Valve
Issued 9 March 2009 Resolved
Secure excessive lube oil leaks on both main engines per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 9 April 2009
Resolved 26 March 2009
Resolution: Both engines were cleaned and according to the owner bolts were tighten.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 February 2009 Resolved
Repair starboard rail course on bow.
Action required: 705 - Other - as specified
Resolved 18 February 2009
Resolution: Deteriorated wood on deck removed and repaired; rail reattached satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 9 February 2009 Resolved
Clean marked sections of hull for further inspection.
Action required: 705 - Other - as specified
Resolved 18 February 2009
Resolution: All areas cleaned, area on port quarter repaired satisfactorily.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 February 2008 Resolved
Repair and prove operation of starboard side light as per 46 CFR 183.420
Due 26 March 2008
Resolved 26 March 2008
Resolution: Starboard side light has been repaired and operates properly.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 26 February 2008 Resolved
Provide NOAA registration for EPIRB as per 46 CFR 180.64
Due 26 March 2008
Resolved 26 March 2008
Resolution: EPIRB has been registered with NOAA.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 February 2008 Resolved
Provide donning placards for all styles of lifejackets onboard as per 46 CFR 185.604
Due 26 March 2008
Resolved 26 March 2008
Resolution: Donning placards are in place.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 February 2008 Resolved
Provide lifejacket storage placard for all adult lifejackets as per 46 CFR 185.604
Due 26 March 2008
Resolved 26 March 2008
Resolution: The placard is in place.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 February 2008 Resolved
Replace expired ammonia inhalants for first aid kit as per 46 CFR 184.710
Due 26 March 2008
Resolved 26 March 2008
Resolution: Ammonia inhalants are now up to date.
Construction/Loadline › Structures › Superstructure
Issued 26 February 2008 Resolved
Repair rotten area on overhang forward of pilot house as per 46 CFR 176.800
Due 26 March 2008
Resolved 26 March 2008
Resolution: The rotten area has been properly repaired.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 26 February 2008 Resolved
Provide deviation table for magnetic compass as per 46 CFR 185.304
Due 26 March 2008
Resolved 26 March 2008
Resolution: Deviation table has been provided.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 February 2008 Resolved
Properly mount the engine room bilge high level alarm as per 46 CFR 183.530
Due 26 March 2008
Resolved 26 March 2008
Resolution: The float switch for the alarm has been properly mounted.
Stability › Weathertight Integrity › General
Issued 26 February 2008 Resolved
Properly mount the door between the lazerette and the engine room as per 46 CFR 176.800
Due 26 March 2008
Resolved 26 March 2008
Resolution: The door has been properly mounted.
Lifesaving › Hand Flares › Storage
Issued 26 February 2008 Resolved
Provide a brightly colored storage container for the distress signals as per 46 CFR 185.614
Due 26 March 2008
Resolved 26 March 2008
Resolution: A brightly colored container has been provided.
Engineering › Fuel Oil Service System › Filter
Issued 26 February 2008 Resolved
Clean and tighten the connections for the fuel filters for both main engines as per 46 CFR 182.455
Due 26 March 2008
Resolved 26 March 2008
Resolution: The connections have been tightened and cleaned.
Engineering › Fuel Oil Service System › Valve
Issued 26 February 2008 Resolved
Install an extension for the port fuel shut off valve to bring handle within 12 inches of the opening as per 46 CFR 182.455
Due 26 March 2008
Resolved 26 March 2008
Resolution: An extension for the valve has been provided.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 26 February 2008 Resolved
Properly secure the strainer for the generator raw water intake as per 46 CFR 176.800
Due 26 March 2008
Resolved 26 March 2008
Resolution: The strainer has been secured to it''s mount.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 26 February 2008 Resolved
Properly support the rubber hoses on the outboard side of starboard engine as per 46 CFR 176.800
Due 26 March 2008
Resolved 26 March 2008
Resolution: The hoses are now properly supported.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 26 February 2008 Resolved
Properly support the metallic pipe on the outboard side of the port engine as per 46 CFR 176.800
Due 26 March 2008
Resolved 26 March 2008
Resolution: The pipe is now properly supported.
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2007 Resolved
Make the stem ready for inspection in way of removing all paint in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 21 March 2007
Resolution: Made stem ready for inspection.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 5 March 2007 Resolved
Replace the strut bearings on both the starboard and port shafts in accordance with 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 21 March 2007
Resolution: Replaced the strut bearings on both the port and starboard shafts.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 5 March 2007 Resolved
Make the propellers ready for inspection by cleaning and removing growth in accordance with 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 21 March 2007
Resolution: Made propellers ready for inspection by cleaning and removing growth.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 5 March 2007 Resolved
Prove proper operation of the valve at the hull for the raw water intake for the port main engine in accordance with 46 CFR 176.802.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 21 March 2007
Resolution: Proved proper operation of the valve at the hull for the raw water intake for port main engine.
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2007 Resolved
Remove all rotten planks and make proper repairs in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 21 March 2007
Resolution: Removed all rotten planks and made proper repairs.
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2007 Resolved
Remove all angel hair on structural members and interior of the hull in the engine room in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 30 March 2007
Resolution: Removed all angel hair on structural members and interior of the hull in the engine room.
Construction/Loadline › Hull › Transverse Frame
Issued 5 March 2007 Resolved
Replace the structural members in the engine room that have been cut/altered or deteriorated in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 30 March 2007
Resolution: Replaced the structual members in the engine room that have been cut/altered or deteriorated.
Engineering › Generator (propulsion/auxiliary-electric) › Receptacle
Issued 5 March 2007 Resolved
Prove proper operation of the generator raw water intake valve in accordance with 46 CFR 176.802.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 21 March 2007
Resolution: Proved proper operation of the generator raw water intake valve.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 5 March 2007 Resolved
Make repairs to the areas of both struts in way of the hardware and supports in accordance with 46 CFR 176.802.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 21 March 2007
Resolution: Made repairs to the areas of both struts in way of hardware and supports.
Construction/Loadline › Structures › Deck Plating
Issued 5 March 2007 Resolved
Remove angel hair from the frame heads and structural members in way of the gunwale and replace as needed in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 30 March 2007
Resolution: Removed angel hair from the frame heads and strucrtural members in way of the gunwale and replaced as needed.
Construction/Loadline › Hull › Keel
Issued 2 March 2007 Resolved
Replace the worm infested areas of the wormshoe in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 21 March 2007
Resolution: Replaced the worm infested areas of the wormshoe.
Engineering › Bilge Water Management System › Pump
Issued 15 February 2007 Resolved
Prove proper operation of indicator light for the bilge pump in the engine room to satisfaction of the attending Coast Guard Marine Inspector as required by 182.530.
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 21 March 2007
Resolution: Proved proper operation of indicator light for the bilge pump in the engine room.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 February 2007 Resolved
Prove proper operation of anchor light to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 183.420.
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 21 March 2007
Resolution: Proved proepr operation of the anchor light as required by 46 CFR 183.420.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 15 February 2007 Resolved
Provide a crew only sign leading up to the pilot house to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 17.900.
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 21 March 2007
Resolution: Provided a crew only sign leading up to the pilot house.
Construction/Loadline › Penetrations › Valve Flange
Issued 15 February 2007 Resolved
Provide a positive means for securing the overboard discharge for the independent bilge pump to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 182.510.
Due 15 March 2007
Resolved 21 March 2007
Resolution: Provided a positive means for securing the overboard discharge for the independent bilge pump as per 46 CFR 182.510.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 February 2007 Resolved
Provide and install adequate machinery guards over rotating machinery in the engine room to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 21 March 2007
Resolution: Provided and installed adequate machinery guards over rotating machinery in the engine room as per 46 CFR 177.960.
Engineering › Fuel Oil Service System › Filter
Issued 15 February 2007 Resolved
Replace the plastic plug on the fuel filter to the satisfaction of the attending Coast Guard Marine Inspector as required by 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 21 March 2007
Resolution: Replaced the palstic plug on the fuel filter as per 46 CFR 182.455.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 10 April 2006 Resolved
Provide and install retro-reflective material on the lifejacket as needed in accordance with 46 CFR 185.604(h).
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 22 May 2006
Resolution: Provided and installed retro-reflective material on the lifejacket as needed in accordance with 46 CFR 185.604(h).
Lifesaving › Buoyant Apparatus › Lifeline
Issued 10 April 2006 Resolved
Provide and install grab lines on the buoyant apparatus where needed in accordance w/ 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 22 May 2006
Resolution: Provided and installed grab lines on the buoyant apparatus where needed in accordance w/ 46 CFR 180.175.
Engineering › Bilge Water Management System › Pump
Issued 10 April 2006 Resolved
Prove the indication light for the bilge pump in the engine room is functional in accordance w/ 46 CFR 182.520(a).
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 22 May 2006
Resolution: Proved the indication light for the bilge pump in the engine room is functional in accordance w/ 46 CFR 182.520(a).
Engineering › Bilge Water Management System › Pump
Issued 10 April 2006 Resolved
Prove proper operation of the bilge pump in the lazarette in accordance w/ 46 CFR 182.520.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 22 May 2006
Resolution: Proved proper operation of the bilge pump in the lazarette in accordance w/ 46 CFR 182.520.
Engineering › Steering Gear System › Ram
Issued 10 April 2006 Resolved
Make repairs to the leaking steering ram or replace for the steering system located in the lazarette in accordance w/ 46 CFR 182.600.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 22 May 2006
Resolution: Made repairs to the leaking steering ram or replace for the steering system located in the lazarette in accordance w/ 46 CFR 182.600.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 April 2006 Resolved
Make repairs to the wet exhaust piping on the port main engine just aft of the water injection port in the way of the leak.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 22 May 2006
Resolution: Made repairs to the wet exhaust piping on the port main engine just aft of the water injection port in the way of the leak.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 April 2006 Resolved
Provide and install proper machinery guards on the port and starboard main engines and the ship service generator in accordance w/ 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 22 May 2006
Resolution: Provided and installed proper machinery guards on the port and starboard main engines and the ship service generator in accordance w/ 46 CFR 177.960.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 April 2006 Resolved
Provide a marine radio operators permit as required 46 CFR 184.502
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 22 May 2006
Resolution: Reviewed and found satisfactory marine radio operators permit issued to [name withheld] serial number MP00011940 effective 4/21/2006 with an expiration date of 4/21/2011.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 March 2005 Resolved
Provide proof of enrolement in a drug program as required by 46 CFR Part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Drug card was provided.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 15 March 2005 Resolved
Provide operator's license as required by 46 CFR 15.805.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Operator''s license was provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 March 2005 Resolved
Provide updated Light List and Coast Pilot IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 7 April 2005
Resolution: Light List and Coast Pilot were provided.
Communications › Audible Communications › Horn/Whistle
Issued 15 March 2005 Resolved
Renew/repair horn to operate IAW 33 CFR Part 86.
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 7 April 2005
Resolution: Horn was repaired.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 15 March 2005 Resolved
Renew/repair waterlight attached to bouyant apparatus IAW 46 CFR 180.175.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Waterlight was renewed.
Lifesaving › Buoyant Apparatus › Painter
Issued 15 March 2005 Resolved
Attach painter to bouyant apparatus IAW 46 CFR 160.237.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Painter was attached to bouyant apparatus.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 15 March 2005 Resolved
Renew/replace retroreflective tape on bouyant apparatus as required by NVIC 2-63.
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 7 April 2005
Resolution: Retroreflective material was repaired.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 15 March 2005 Resolved
Renew/repair retroreflective material on 3 PFDs IAW 46 CFR 185.604(h).
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 7 April 2005
Resolution: Retroreflective material was repaired.
Construction/Loadline › Structures › Ventilators
Issued 15 March 2005 Resolved
Provide ventilation closure device for 1 port side vent IAW 46 CFR 182.15-45.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Ventilation shutdowns were provided and operated correctly.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 March 2005 Resolved
Renew/repair visual indicator for center bilge pump IAW 46 CFR 182.530(c).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Center bilge pump indicator light repaired.
Construction/Loadline › Hull › Side Shell
Issued 22 February 2005 Resolved
Repair or renew detriorated section of hull planking in way of amidships near water line were rotten through the hull. Areas must be repaired in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 1 March 2005
Resolution: Rotted planks were replaced in accoradnce with NVIC 7-95.
Construction/Loadline › Hull › Keel
Issued 22 February 2005 Resolved
Repair or renew deteriorated section of hull planking in way of aft end of the keel that is rotten. All repairs or renewals shall be conducted in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 1 March 2005
Resolution: Area was cut out and filled with epoxy putty.
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2005 Resolved
Recaulk two sections of hull planking in way chine port side approximately 15-ft aft of the stem. All repairs shall be conducted in accordance with NVIC 7-95.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 1 March 2005
Resolution: Area was satisfactorily recaulked.
Construction/Loadline › Structures › Deck Plating
Issued 22 February 2005 Resolved
Repair or renew deteriorated section of forecastle deck. All repairs or renewal shall be completed in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 March 2005
Resolution: Area was replaced with marine grade plywood and covered in fiberglass.
Lifesaving › Buoyant Apparatus
Issued 27 February 2004 Resolved
Renew buoyant apparatus lifeline and pendants IAW 46 CFR 180.175(d).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2004
Resolution: Lifeline and pendants on buoyant apparatus replaced IAW 46 CFR 180.175 (d).
Documentation › Certificates/Documents
Issued 20 March 2003 Resolved
Provide and post on board vessel a valid FCC Safety Certificate as required by 46 CFR 184.502 LEGACY COMPONENT DESC: FCC Safety Certificate
Due 20 April 2003
Resolved 21 April 2003
Resolution: FCC Safety Certifcate provided.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 15 February 2002 Resolved
REPAIR PORT MAIN ENGINE, WILL NOT SHIFT ASTERN.
Due 15 February 2002
Resolved 15 February 2002
Resolution: CORRECTED DURING INSPECTION.
Electrical
Issued 26 March 2001 Resolved
PROVIDE GUARDS FOR LIGHT FIXTURES IN E/R AS REQUIRED BY 46 CFR 183.410
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Lifesaving
Issued 26 March 2001 Resolved
PROVIDE PROPERLY SIZED LIFE RING BUOY AS REQUIRED BY 46 CFR 180.70._x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 28 March 2001
Resolved 3 April 2001
Engineering
Issued 26 March 2001 Resolved
PROVIDE MACHINERY GUARD ON GENERATOR OVER EXPOSED BELTS AS REQUIRED BY 46 CFR 177.960
Condition: Unknown
Due 28 March 2001
Resolved 3 April 2001
Engineering
Issued 26 March 2001 Resolved
PROVIDE PROPER CLOSURE FOR E/R VENTS AS REQUIRED BY 46 CFR 182.465._x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 28 March 2001
Resolved 3 April 2001
Lifesaving
Issued 26 March 2001 Resolved
PROVIDE BATTERY FOR SMOKE DETECTOR IN SALON AS REQUIRED BY 46 CFR 181.450_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 28 March 2001
Resolved 3 April 2001
Electrical
Issued 26 March 2001 Resolved
PROVIDE PROPER SUPPORTS FOR BILGE HIGH LEVEL ALARM WIRING IN FUEL TANK SPACE AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Documentation
Issued 26 March 2001 Resolved
PROVIDE FCC SAFETY RADIO CERTIFICATE AND MARINE OPERATORS PERMIT AS REQUIRED BY 47 CFR 80.905
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Navigation
Issued 26 March 2001 Resolved
PROVIDE LIGHT FOR MAGNETIC COMPASS AS REQUIRED BY 46 CFR 184.402
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Lifesaving
Issued 26 March 2001 Resolved
PROVIDE PROPER SIZED WEAK LINK FOR LIFE FLOAT AS REQUIRED BY 46 CFR 180.200._x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 28 March 2001
Resolved 3 April 2001
Navigation
Issued 26 March 2001 Resolved
PROVE PROPER OPERATION OF HORN SIGNALING DEVICE AS REQUIRED BY 33 CFR 86
Condition: Unknown
Due 28 March 2001
Resolved 3 April 2001
Accommodation/Occupational Safety
Issued 26 March 2001 Resolved
PROVIDE MARKING INDICATING NO PASSENGERS ALLOWED ON UPPER DECKS AS REQUIREDBY 46 183.550
Condition: Unknown
Due 28 March 2001
Resolved 3 April 2001
Construction/Loadline
Issued 26 March 2001 Resolved
MAKE FWD AND AFT BULKHEADS IN E/R VAPOR TIGHT._x001C_
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Engineering
Issued 26 March 2001 Resolved
REPAIR FUEL LEAK ON PORT FUEL TANK SUCTION VALVE._x001C_
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Documentation
Issued 10 April 2000 Resolved
PROVIDE UP TO DATE SAFETY CERTIFICATE AS REQUIRED BY 47 CFR 80.15
Condition: Unknown
Due 10 May 2000
Resolved 26 April 2000
Engineering
Issued 6 March 1998 Resolved
RENEW FUEL FITTING ON GENERATOR RETUN HOSE WITH A FITTING THAT MEETS SAE STANDARD J-1475 AS PER 46 CFR 182.720(e).
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 6 March 1998 Resolved
RENEW FRACTURED SHELF CLAMP ON STARBOARD SIDE OF ENGINE ROOM. NIVC 7-95
Condition: Unknown
Due 6 March 1998
Resolved 26 March 1998
Construction/Loadline
Issued 6 March 1998 Resolved
RENEW DETERIORATED TOP BLOCKS OVER STRUTS BOTH PORT AND STARBOARD SIDE. SEENVIC 7-95.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 6 March 1998 Resolved
RENEW ROTTED DECK UNDER SINK AFT OF CABIN SEE NVIC 7-95.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 6 March 1998 Resolved
RENEW ROTTED DECK SUPPORT PORT SIDE AFT IN ENGINE ROOM. NVIC 7-95.
Condition: Unknown
Due 6 March 1998
Resolved 26 March 1998
Construction/Loadline
Issued 6 March 1998 Resolved
RENEW ROTTED BUTT BLOCK PORT SIDE AMIDSHIP AT THE CHINE. NVIC7-95.
Condition: Unknown
Due 6 March 1998
Resolved 26 March 1998
Construction/Loadline
Issued 6 March 1998 Resolved
RENEW CHINE BOARDS PORT SIDE. NVIC 7-95.
Condition: Unknown
Due 6 March 1998
Resolved 26 March 1998
Engineering
Issued 6 March 1998 Resolved
PROPERLY REPAIR EXHAUST LEAK ON PORT ENGINE OUTBOARD SIDE AS PER 46 CFR 182.15-20(a).
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Electrical
Issued 6 March 1998 Resolved
PROVIDE AND POST GENERATOR DATA PLATE AS PER 46 CFR 183.05-5.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Engineering
Issued 25 April 1997 Resolved
THE VESSEL'S ENGINES REQUIRED GUARDS FOR THE PULLEY ASSEMBLIES.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Lifesaving
Issued 25 April 1997 Resolved
THE WATERLIGHT FOR THE VESSEL'S LIFE FLOAT WAS NOT SEALING AND WATER WAS LEAKING IN.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Fire Fighting
Issued 25 April 1997 Resolved
ALL OF THE VESSEL'S B-II PORTABLE FIRE EXTINGUISHER MOUNTS WERE BROKEN OR NOT OF THE TYPE REQUIRED FOR THE EXTINGUISHER.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Navigation
Issued 25 April 1997 Resolved
THE OPERATOR DID NOT PROVIDE UP-TO-DATE PUBLICATIONS IN ACCORDANCE WITH 46 CFR 184.420.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Accommodation/Occupational Safety
Issued 25 April 1997 Resolved
THE OPERATOR DID NOT HAVE A WASTE MANAGEMENT PLAN POSTED FOR THE VESSEL IN ACCORDANCE WITH 33 CFR 151.57.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Lifesaving
Issued 25 April 1997 Resolved
ONE CHILDREN'S PFD WAS MISSING AS REQUIRED BY ;46 CFR 185.604(f).
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Accommodation/Occupational Safety
Issued 25 April 1997 Resolved
THE EXTERIOR SIDE OF THE VESSEL'S EMERGENCY EXIT WAS NOT MARKED IN ACCORDANCE 46 CFR 185.606.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Engineering
Issued 25 April 1997 Resolved
THE VESSEL'S FUEL LINE REMOTE EMERGENCY SHUT-OFF VALVES' HANDLES WERE EXCESSIVELY CORRODED AND BROKE OFF.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Navigation
Issued 25 April 1997 Resolved
THE VESSEL DID NOT HAVE A SHIP'S BELL IN ACCORDANCE WITH 72 COLREGS ANNEX III 2(b).
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Engineering
Issued 15 March 1996 Resolved
PROVIDE FUEL OIL SHUTOFF VALVES LOCATED NEAR ENGINES FOR ALL DIESEL ENGINESIAW 46 CFR 182.20-40(b)(3).
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Engineering
Issued 15 March 1996 Resolved
REMOVE ALL PUSH ON FUEL LINES FROM ALL ENGINES AND REPLACE WITH PERMANENT FACTORY-ATTACHED END CONNECTIONS.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Lifesaving
Issued 15 March 1996 Resolved
REPAIR OR RENEW RING BOUY, REPAINT AND RE-STENCIL.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Documentation
Issued 3 April 1995 Resolved
PROVIDE FCC OPERATOR'S LICENSE.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 3 April 1995 Resolved
PROVIDE THREE ORANGE DISTRESS FLARES.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Deck/Cargo
Issued 3 April 1995 Resolved
INSTALL THIMBLE ON ANCHOR LINE.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 3 April 1995 Resolved
PERMANENTLY ATTACH 60 FOOT LINE TO RING BUOY.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 3 April 1995 Resolved
INSTALL FREQUENCY METER FOR GENERATOR.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 3 April 1995 Resolved
PROVIDE AND INSTALL LOCK ON MARINE SANITATION DEVICE OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 April 1994 Resolved
MAKE VSL AVAILABLE FOR HULL EXAMINATION DUE TO LEAKAGE NOTED DURING UNDERWAY OPERATIONAL TEST. AREAS OF CONCERN ARE THE PORT SIDE BOW STEM, FRAMES 6 THROUGH 12 IN ENGINEROOM AND JUST FWD OF STEERING GEAR HATCH, STBDSIDE OF KEEL.
Condition: Unknown
Due 7 April 1994
Resolved 7 April 1994
Unknown
Issued 31 May 1988 Resolved
REPAIR OR REPLACE THREE ADULT LIFE PRESERVERS.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Unknown
Issued 31 May 1988 Resolved
PROVIDE TWO VENT COVER/SCOUPS - ONE ON PORT AND ONE ON STBD.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Unknown
Issued 31 May 1988 Resolved
PROVE PROPER OPERATION OF ALL NAVIGATION LIGHTS.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Documentation
Issued 23 June 1987 Resolved
JPROVIDE VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Documentation
Issued 23 June 1987 Resolved
PROVIDE VALID FCC STATION LICENSE.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Documentation
Issued 23 June 1987 Resolved
PROVIDE RENEWAL DECAL FOR COD.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987

Ownership record