Records from 2016 to 2023. Most recent: inspection, 8 May 2023.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Professional
Detail on this page
12 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 12
8 May 2023
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7684405
28 November 2022
Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7601776
16 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7452483
27 May 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7209072
20 January 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7128944
2 June 2020
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6965925
17 June 2019
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6716604
26 March 2019
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6649182
13 June 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6443218
12 April 2017
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6122685
5 April 2017
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6118560
8 July 2016
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5934167
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 May 2022
No resolution recorded
MI discovered that the WHITE STAR's COI expired on 09MAY2022.
46CFR176.100(a): A vessel to which this subchater applies (T) may not be operated without having on board a valid US Coast Guard Certificate of Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2022 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 May 2021
Resolved
A voltmeter and an ammeter shall be provided that can be
used for measuring voltage and current of each generator that is in operation. For alternating-current generators a means for measuring frequency shall also be provided.
WHITE STAR currently is not fitted with means to measure these operating parameters. Install required meters.
46 CFR 183.10-5(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 14 June 2021
Resolution: Installed required meter.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2019
Resolved
Mark space storing CO2
Due 12 July 2019
Resolved 16 July 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2019
Resolved
Mark space protected by CO2
Due 12 July 2019
Resolved 16 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 June 2019
Resolved
Provide current Coast Pilot
Due 12 July 2019
Resolved 16 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2019
Resolved
Properly label PFD storage
Due 12 July 2019
Resolved 16 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 June 2019
Resolved
Replace wire nuts with proper connections
Due 12 July 2019
Resolved 16 July 2019
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 9 May 2017
Resolved
Provide labelling for numbers stored
Due 9 May 2017
Resolved 9 May 2017
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 May 2017
Resolved
Replace broken float light
Due 19 May 2017
Resolved 22 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 May 2017
Resolved
Remove wire nuts
Due 19 May 2017
Resolved 22 May 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 May 2017
Resolved
Provide alarms for tank and engine room.
Due 19 May 2017
Resolved 22 May 2017
Engineering › Fuel Oil Service System › Piping
Issued 9 May 2017
Resolved
Label fuel fills
Due 19 May 2017
Resolved 22 May 2017
Fire Fighting › Fire Hydrants › Condition
Issued 9 May 2017
Resolved
Provide working valve at hydrant
Due 19 May 2017
Resolved 22 May 2017
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 21 July 2016
Resolved
Provide proof of enrollment in a drug and alcohol testing program
Due 5 August 2016
Resolved 5 August 2016
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 July 2016
Resolved
Provide current light list and tide tables
Due 5 August 2016
Resolved 9 August 2016
Communications › Radio Communications › Satellite Communications Capability
Issued 21 July 2016
Resolved
Provide means for VHF to transmit GPS coordinates on DSC
Due 21 August 2016
Resolved 25 August 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 July 2016
Resolved
Provide blanks or cover for open spaces in bridge breaker panel
Due 5 August 2016
Resolved 9 August 2016
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 July 2016
Resolved
Replace fuel shutoff reach rods
Due 5 August 2016
Resolved 9 August 2016