Records from 1998 to 2025. Most recent: inspection, 20 October 2025.
Inspection history · 39
20 October 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8255960
2 October 2025
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8245552
3 January 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8049823
4 January 2024
Deficiency Check · Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7833886
13 December 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7608745
21 September 2022
Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7560521
4 January 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7375310
27 October 2020
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7089600
13 October 2020
Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7075889
6 January 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6883733
4 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6605688
10 December 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6595277
19 June 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6452397
21 September 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6271904
15 September 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6267398
27 October 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6030920
7 October 2015
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5737146
17 September 2015
Internal Structural Exam · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5726064
12 December 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4206823
13 September 2010
COI Inspection · Internal Structural Exam · Drydock Exam · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3846868
6 November 2008
Annual Inspection · Ballast Water Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3358180
24 September 2007
MTSA Verification · Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3065184
24 May 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2657597
13 September 2005
Examination of Repairs · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2501207
12 November 2004
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2295297
8 November 2004
MTSA Verification · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2237004
11 April 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2048610
15 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978043
10 December 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1961968
5 November 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1942427
25 March 2003
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1762589
1 November 2002
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1694396
27 July 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459731
14 September 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462884
1 December 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456759
20 October 1999
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125244
19 May 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806477
25 September 1998
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1369075
24 August 1998
Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 798262
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 October 2025
Resolved
For vessels assigned a load line, see Subchapter E (Load Lines) for closure of openings and the like. The following items must be verified complete prior to departing Golden Meadow/ Port Fourchon:
-Weld/ complete insert above the STBD MDE. NDT.
-Crop/renew wasted area of aft house to good metal. NDT.
-Wasted fire dampener on main deck. Repair.
46 CFR 125.140
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2025
Resolved 31 October 2025
Resolution: 30OCT25 attended, & verified completion of deck insert above STBD MDE – sat dye pen for NDT. Verified repairs to fire dampener.
31OCT – ABS reattended and verified completion of aft house insert/ dye pen NDT. ILLC endorsed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 October 2025
Resolved
Sea valves must be opened for examination every 5 years at the time of drydocking. The sea valve for the fire pump suction was replaced by the shipyard during the OCT25 drydocking. When testing the bilge pump with a crossover to the fire pump, the sea valve was found leaking.
46 CFR 61.20-5
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2025
Resolved 30 October 2025
Resolution: Crew pressured the fire pump at MI reattendance. Verified no leaks. Shipyard POC was present and informed that the shipyard tightened the packing glands to resolve the issue. Shipyard work report attached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2025
Resolved
Electrical equipment must be maintained to minimize accidental personal contact with energized parts and prevent electrical ignition. A spliced monitor cable, and a dead-end windshield wiper cable were under forward operating console.
46 CFR 129.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2025
Resolved 31 October 2025
Resolution: All dead ended wires from under the operating console were verified pulled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 October 2025
Resolved
Inspection for certification is made to determine safe/seaworthy condition of items to include piping. The nonmetallic connection on fuel piping in the main machinery space is dry rotting and has broken clamps and should be renewed.
46 CFR 126.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2025
Resolved 30 October 2025
Resolution: The nonmetallic connection was verified renewed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 January 2025
Resolved
Navigation light panel must visually and audibly signal the failure of each navigation light. Light panel does not have audible or visual indication of failure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2025
Resolved 3 January 2025
Resolution: Vessel repaired light pannel to indicate which light is on and indication of failure.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 January 2025
Resolved
Each vessel must meet the applicable navigation rules. Vessel bottom red light not functional, middle white light not installed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2025
Resolved 3 January 2025
Resolution: Vessel repaired inoperable lights
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 3 January 2025
Resolved
Each OSV muster station and embarkation station must be adequately illuminated by emergency source of power. Embarkation lights do not illuminate on emergency power.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2025
Resolved 3 January 2025
Resolution: Replaced embarkation lighting.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 January 2025
Resolved
Exhausts of internal combustion engines must be insulated. Port and STBD engine exhausts have missing insulation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2025
Resolved 14 January 2025
Resolution: Repaired exhaust wrap.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 January 2022
Resolved
Class-1 door may be installed at any place if... the vsl's pilothouse contains a visual indicator showing whether the door is opened or closed. There is no indicator in the pilothouse for the door between the main engine and generator spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2022
Resolved 6 January 2022
Resolution: Indicator panel installed in pilothouse.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 January 2022
Resolved
Inspection is made by a marine inspector to determine whether the vsl is ina safe and seaworthy condition. There is an exhaust leak in the port stack that is filling the generator space with exhaust fumes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2022
Resolved 6 January 2022
Resolution: Exhaust pipe renewed in stack.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 January 2022
Resolved
Each ring buoy on a vsl in ocean service must be marked in block capital letters with the name of the port marked on the stern of the vsl. "Raceland" is the port on the stern, but buoys were marked with "New Orleans".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2022
Resolved 6 January 2022
Resolution: Ring buoys properly marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 October 2020
Resolved
Non-metallic flexible hose must in accordance with SAW J1942; Starboard fuel line was observed to have a tear in the outer coating. Vessel shall maintain non-flexible fuel line to prevent possible fire.
Action required: 10 - Deficiency Rectified
Due 27 October 2020
Resolved 2 November 2020
Resolution: Vessel rep provided photos of new fuel hose installation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020
Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to minimize accidental personal contact with energized parts; Dead end wire was observed on the starboard engine. Vessel shall maintain electrical wires to protect from electrical hazards.
Action required: 10 - Deficiency Rectified
Due 27 October 2020
Resolved 27 October 2020
Resolution: Vessel rep provided photographic evidence of dead end wires being removed from the starboard engine.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 October 2020
Resolved
A class-1 door may be installed at any place if: The vessel's pilothouse contains a visual indicator showing whether the door is open or closed; The watertight door indicator did not properly function to indicate if the door was open or closed. Vessel shall ensure the indicator is in working condition to indicate if the status of the door.
Action required: 10 - Deficiency Rectified
Due 27 October 2020
Resolved 27 October 2020
Resolution: Vessel rep provided video evidence of watertight door indicator properly operating.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 27 October 2020
Resolved
The inspection for certification is made by a marine inspector to determine whether the vessel is in a safe and seaworthy condition. The owner or builder shall make the vessel and its equipment available for inspection, including the following items: Watertight integrity, Main and auxiliary machinery.
Action required: 10 - Deficiency Rectified
Due 27 October 2020
Resolved 27 October 2020
Resolution: Dogs for the watertight door were tightened, ensuring satisfactory watertight integrity.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 October 2020
Resolved
Unless expressly provided otherwise in this part, this part applies to all inspected OSVs of the United States flag: By October 1, 1997, fit retro-reflective material on all floating appliances; Vessel had wasted retro-reflective material on 04 lifefloats; Replace retro-reflective material on 04 lifefloats.
Action required: 10 - Deficiency Rectified
Due 27 October 2020
Resolved 27 October 2020
Resolution: Vessel rep provided photographic evidence of newly installed retro-reflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 October 2020
Resolved
Lifefloats must be stowed in such a way that it runs out freely when the buoyant appartus, inflatable buoyant apparatus, or lifefloat floats away from the sinking OSV; Painter line on stbd side lifefloats was arranged in such a way that lifefloats would not freely pay out; Rearrange set-up to enable painter line to freely pay out.
Action required: 10 - Deficiency Rectified
Due 27 October 2020
Resolved 27 October 2020
Resolution: Vessel rep provided photographic evidence of painter line installation to ensure line would freely pay out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 October 2020
Resolved
The shaft seal on the port side was leaking a long drip stream every second without the shaft turning. Vessel shall maintain the shaft seal to maintain the watertight integrity against excessive dripping.
Action required: 10 - Deficiency Rectified
Due 27 October 2020
Resolved 27 October 2020
Resolution: Vessel rep satisfactorily installed new shaft seal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2020
Resolved
The following non-metallic hoses were worn and degraded leaking fuel oil; 02 hoses on forward generator, and 01 oil hose on the starboard MDE. Vessel must ensure the hoses and fittings are replaced and meet SAE J1942 & SAE J1475 standard respectively.
46CFR58.01-20
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2020
Resolved 6 January 2020
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 6 January 2020
Resolved
Vessel rudder angle indicator is multiple degrees off on both the forward and rear operating stations. Vessel must ensure rudder angle indicator operates properly.
46CFR130.130(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2020
Resolved 7 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2020
Resolved
Vessel had inoperable ballast pump located in generator space. Vessel must ensure pump is fixed and that vital system on board is operable.
46CFR128.130(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2020
Resolved 7 January 2020
Construction/Loadline › Penetrations › Pipe Flange
Issued 21 September 2017
Resolved
Sewage overboard line leaking between between hull and valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 18 October 2017
Resolution: Provided picture as evidence that repairs have been made.
Engineering › Thrusters › Seal
Issued 21 September 2017
Resolved
Leaking Bow Thruster pump drive seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 17 October 2017
Resolution: Provided a service ticket report confirming replacement and repairs to thruster seal.
Engineering › Bilge Water Management System › Piping
Issued 21 September 2017
Resolved
Leaking bilge piping for overboard discharged cracked.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 18 October 2017
Resolution: Provided Shipyard invoice as which included bilge piping repair as evidence that repairs had been completed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 September 2017
Resolved
Water in battery boxes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 18 October 2017
Resolution: Provided picture as evidence that water had been removed.
Accommodation/Occupational Safety › Potable Water System › General
Issued 21 September 2017
Resolved
Lable water valves on water manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 18 October 2017
Resolution: Provided pictures as evidence that the manifold has been labeled.
Lifesaving › Lifebuoys › Serviceable
Issued 21 September 2017
Resolved
Renew retro tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 18 October 2017
Resolution: Provided picture that the reflective tape on bouys have been renewed.
Documentation › Certificates/Documents › FCC SSL
Issued 21 September 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 22 September 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 21 September 2017
Resolved
Provide prove of proper operation of ground fault detection system on main switch board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 20 October 2017
Resolution: Company submitted pictures of the ground fault sensor and third party service report stating that the Ground Fault detector has been replaced and tested satifactory.
Construction/Loadline › Structures › Machinery Space Opening
Issued 21 September 2017
Resolved
Adjust engine room quick acting WTD release to provide water tight integrity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 18 October 2017
Resolution: Provided picture that the water tight door dogs have been adjusted.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 21 September 2017
Resolved
Up date proper hailing port on the stern to match the hailing port on the COD.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 28 September 2017
Resolution: A new COD was applied for and received with the hailing port on the COD that match hailing port on the stern.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 October 2016
Resolved
Rox block installation had missing blocks.
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 28 October 2016
Resolution: ABS verified repairs while conducting Load Line survey.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 October 2016
Resolved
Watertight bulk head had holes drilled through it.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2016
Resolved 28 October 2016
Resolution: ABS verified repairs while conducting Load Line survey.
Construction/Loadline › Structures › Scuttle
Issued 27 October 2016
Resolved
Emergency escape hatch from engine room was not weather tight.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2016
Resolved 28 October 2016
Resolution: ABS verified repairs while conducting Load Line survey.
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 27 October 2016
Resolved
Fuel leak was discovered on fuel transfer manifold.
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 28 October 2016
Resolution: Bolts were tightened down on flanges to make a better fit.
Deck/Cargo › Ballast › Valves
Issued 27 October 2016
Resolved
2 Ballast piping transfer valves were inop.
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 28 October 2016
Resolution: Two new butterfly valves were installed and pictures were emailed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 October 2016
Resolved
Offshore Worker Cabin didn't not have adequate Emergency Lighting.
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: New e-lighting fixture installed.
Lifesaving › Lifebuoys › Serviceable
Issued 13 September 2010
Resolved
Replace two (2) cracked lifebuoys
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2010
Resolution: Lifebuoys replaced.
Engineering › Steering Gear System › Ram
Issued 13 September 2010
Resolved
Rudders unable to be turned from 35 degrees right rudder to 35 degrees left rudder
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2010
Resolution: Steering operating properly.
Construction/Loadline › Structures › Manhole
Issued 13 September 2010
Resolved
Found hole in port side escape hatch.
Due 1 October 2010
Resolved 24 September 2010
Resolution: Hole welded.
Lifesaving › Lifebuoys › Serviceable
Issued 24 September 2007
Resolved
2 of the Ringbuoys had cut lines making them unserviceable. Renew lines or replace ring buoys.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2007
Resolution: New ringbuoys put onboard.
Engineering › Compressed Air System (start air) › Valve
Issued 24 September 2007
Resolved
Pressure relief valves on both pressure vessels needs to be renewed or tested.
Due 3 November 2007
Resolved 3 October 2007
Resolution: New pressure relief valves installed on board.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 13 September 2005
Resolved
Provide vessel specific Ballast Water Management plan prior to 19 OCT 2005 or before conducting Ballast operations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 7 December 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 13 September 2005
Resolved
Provide spare Dry Chemical extinguishers for portable tanks prior to 19 OCT 2005, or before carriage of Portable tanks.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 20 October 2005
Resolution: Spare extinguishers provided.
Documentation › Certificates/Documents › FCC SSL
Issued 13 September 2005
Resolved
Provide station license with MMSI number prior to 19 OCT 2005.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 7 December 2006
Resolution: New FCC SSL and MMSI valid.
Engineering
Issued 5 November 2003
Resolved
Provide shaft tachs per 46 CFR 113.37.
Action required: 705 - Other - as specified
Due 5 January 2004
Resolved 10 December 2003
Resolution: Provided
Communications
Issued 5 November 2003
Resolved
Provide emergency power for SSB radio.
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 10 December 2003
Resolution: Provided
Pollution Prevention/Response
Issued 5 November 2003
Resolved
Provide annual hydrostatic test for F/O transfer hoses.
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 10 December 2003
Resolution: Provided
Engineering
Issued 5 November 2003
Resolved
Provide mud basket strainer at bilge pump suction inlet per 46 CFR 56.50-50.
Action required: 705 - Other - as specified
Due 5 January 2004
Resolved 10 December 2003
Resolution: Provided
Communications
Issued 5 November 2003
Resolved
Provide red light for general alrm in generator room per 46 CFR 113.25-10.
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 10 December 2003
Resolution: Provided
Pollution Prevention/Response
Issued 5 November 2003
Resolved
Provide 3/4 full alarm for MSD holding tank per 46 CFR 131.940.
Action required: 705 - Other - as specified
Due 5 January 2004
Resolved 10 December 2003
Resolution: Provided
Construction/Loadline
Issued 20 October 1999
Resolved
REPAIR DAMAGE IN PORT SIDE SHELL PLATE AT GALLEY MAINDECK AREA AND ADJACENTFRAMING. REMOVE TEMPORARY REPAIR, INSTALL INSERTS IN KIND, TO BE COMPLETED TO THE SATISFACTION TO THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS, THE PLANS FOR THE STEERING CONTROL SYSTEM AS REQUIRED BY 46 CFR 127.110(d)(3).
Condition: Unknown
Due 25 September 1998
Resolved 25 September 1998
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS, THE PLANS FOR ELECTRICAL ARRANGEMENT, SWITCHBOARD, AND ELECTRICAL ONE LINE DIAGRAM ASREQUIRED BY 46 CFR 127.110(e).
Condition: Unknown
Due 25 September 1998
Resolved 25 September 1998
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS THE PLANS FOR THE BOW THRUSTER FLUID POWER SYSTEM AS REQUIERD BY 46 CFR 127.110(d)
Condition: Unknown
Due 25 September 1998
Resolved 25 September 1998
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS, THE PLANS FOR THE COMPRESSED AIR SYSTEM AS REQUIRED BY 46 CFR 127.110(d)(2)(ix).
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS, THE PLANS FOR THRU HULL PENETRATIONS AND SHELL CONNECTIONS AS REQUIRED BY 46 CFR 127.110(d)(2)(vi).
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS, THE PLANS FOR THE SANITARY SYSTEM AS REQUIRED BY 46 CFR 127,110(d)(2)(vii).
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSATNDING COMMENTS, THE PLANS FOR VENTS, SOUNDINGS AND OVERFLOWS AS REQUIRED BY 46 CFR 127.110(d)(2)(viii).
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS, THE PLANS FOR THE PROPULSION CONTROL SYSTEM AS REQUIRED BY 46 CFR 127.110(d)(4).
Condition: Unknown
Due 25 September 1998
Resolved 25 September 1998
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS, THE PLANS FOR THE BALLAST SYSTEM AS REQUIRED BY 46 CFR 127.110(d)(2)(iv).
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS, THE PLANS FOR FUEL OIL FILL, SERVICE, AND TRANSFER AS REQUIRED BY 46 CFR 127.110(d)(2)(i).
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS, THE PLANS FOR THE FIRE MAIN SYSTEM AS REQUIRED BY 46 CFR 127.110(d)(2)(ii).
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Documentation
Issued 25 September 1998
Resolved
VESSEL TO SUBMIT TO G-MSC, THE PLANS FOR THE BILGE SYSTEM AND RESOLVE ALL OUTSTANDING COMMENTS AS REQUIRED BY 46 CFR 127.110 (d)(2)(iii).
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999