FREEDOM

FREEDOM is a 1973 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in June 2025, along with 64 deficiencies — 2 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 15 June 2025.

Built
1973
Last inspected
15 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 June 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK8940
Flag
UNITED STATES
Maury page id
psix-47614

Documentation record

Registered dimensions (L × B × D)60.4 ft × 20.1 ft × 5.7 ft
Registered tonnagegross 61 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1973
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJERSEY CITY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Gross Ton
41 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 21

15 June 2025 Damage Survey · In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8159803
13 March 2025 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8093439
3 December 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8011766
23 October 2023 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7798204
24 January 2023 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7626950
29 September 2022 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7568653
28 August 2022 Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 7545754
4 October 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7326515
30 April 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7186167
20 January 2021 Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7126788
5 October 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7070023
9 July 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7001565
19 March 2020 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6929264
1 August 2019 COI Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6768331
11 June 2019 COI Inspection · Administrative Inspection · DAPI Audit · Initial Certification · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6709742
17 April 2019 Simplified Stability Test
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6664866
19 June 2018 Examination of Repairs · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6448495
14 November 2017 Plan Review "T" Boat · Construction Oversight · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6307209
12 April 2017 In-Service Inspection · Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6123300
13 June 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5905741
30 March 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5843962

Deficiency record · 64

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 June 2025 No resolution recorded
The intent of this part is to insure that the scantlings, material, fastenings, workmanship, and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate inspection. Primary consideration shall be given the the provision of a seaworthy hull. Vessel sustained damage to PORT BOW in an approximate 9' x 5' area affecting hull planking, transverse and longitudinal framing, deck supports, and collision bulkhead. Submit repair proposal prior to commencing work satisfactory to attending Marine Inspector. Proposal and repair shall be approved/completed. Authorized a one-time voyage for perminant repairs at Sector CORAM. 46 CFR 177.01-5 "OLD-T"
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 June 2025 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed. MI discovered STBD Main Engine throttle linkage damaged, resulting in inability to control RPM from the operating station. Replace damaged throttle linkage and conduct satisfactory sea trial to satisfaction of attending Marine Inspector. 46 CFR 182.05-1 "OLD-T"
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 November 2025
Resolution: Throttle system repaird. Completed satisfactory sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2024 No resolution recorded
Exhaust gas must not leak from the piping or any connections. MI identified exhaust leak on port engine. Repair prior to credit dry dock. 46 CFR 182.430(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. MI identified no lifesaving donning placards posted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2025
Resolution: Received photos of lifejacket donning placards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2024 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. MI identified no separation between adult and children life jackets and adult life jackets were not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 March 2025
Resolution: Received photographs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 December 2024 Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. MI identified push button connected to the horn is missing, whistle is inoperable. Repair and label within 14 days. 33 CFR 83.33(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 March 2025
Resolution: Received photographs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2023 Resolved
Propulsion machinery shall be suitable in type and design... it is installed and capable of operating constant marine load. Observed starboard engine raw water leak on pipe to sea strainer with soft patch installed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Leaking pipe cut-out. Pay attention to mounting of flexible hose and sea water strainer. Not mounted securely
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2023 Resolved
...the inspection shall be such as to ensure that the vessel as regards main and auxiliary machinery... is in satisfactory condition and fit for service. Observed fuel leak on port main engine's forward fuel filter housing. 46 CFR 176.05-10(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Swapped filter
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2023 Resolved
...the inspection shall be such as to ensure that the vessel as regards main and auxiliary machinery... is in satisfactory condition and fit for service. Observed oil leak from filter on starboard main engine's inboard, forward side. 46 CFR 176.05-10(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Replaced gaskets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2023 Resolved
...the inspection shall be such as to ensure that the vessel as regards main and auxiliary machinery... is in satisfactory condition and fit for service. Observed fuel, oil, and jacket water leak on generator. Must clean for re-inspection by USCG inspector with generator running under load.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Plugged oil drain hose, replaced J/W hose which had a small leak, and cleaned drip pan.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 October 2023 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system...Vessel's starboard ventilation closure does not operate as designed. Operator must prove proper operation upon re-inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Re-did fasteners and installed a rubber gasket for improved seal.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Observed lack of proper electrical wire isolation/removal of wires no longer in use. 46 CFR 183.01-15(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2023
Resolved 7 December 2023
Resolution: Junction box installed over exposed wires.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 October 2023 Resolved
Vessel must carry a either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel had expired items within first aid kit. 46 CFR 184.710
Action required: 10 - Deficiency Rectified
Resolved 23 October 2023
Resolution: Replaced expired eye wash
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 October 2023 Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Vessel's engine cooling water discharge temperature and lubricating oil pressure gauges do not function properly.
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Gauges function
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 October 2023 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked and clearly legible block capital letters with the vessel's name... Vessel had several lifejackets life that faded labeling and a two vessels' names on it. Lifejackets must have only one vessel's name. 46 CFR 185.604(b)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: Blacked out the second vessel's name in un-sat spots with sharpie. Re-did labelling in select lifejackets to "KEYPORT PRINCESS"
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2023 Resolved
Each floating water light must be approved in accordance with 161.010 and subchapter Q of this chapter or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Vessel ring buoy water light forward of the pilothouse is no longer water tight/operating as designed. The light's covering is broken and exposed to the elements.
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: Float light replaced with new unit.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 23 October 2023 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Observed overhead wire runs entirely by supported by plastic tie wraps a fire and personnel hazard. 46 CFR 183.01-5(a)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Metal electrical cable hangers installed all throughout ship
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 October 2023 Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room... Vessel does have CO2 discharge instructions posted and the bottle locally or at pull station. 46 CFR 181.20-15(d)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Instructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 October 2023 Resolved
The painter must - Be stowed in such a way that it runs out freely when the life float or buoyant apparatus floats away from the sinking vessel. Vessel cannot use zip ties to keep the life float's painter lines tidy as they prevent them from floating freely. 46 CFR 180.15-5(c)(4)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: Painter lines now kept tidy with electrical tape. Painter line will float free.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 October 2023 Resolved
In accordance with Table 182.25-10(a), "S" vessels carrying more than 49 passengers and all "S" ferry vessels of 65 feet or less must have 1 fixed power pump and 1 portable hand pump. Vessel operator could not find portable hand pump at time of inspection. 46 CFR 182.25-10(a)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Bilge hand pump onboard
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 23 October 2023 Resolved
Where a flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used... the flexible section is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. With a flexible hose mid-section of the fuel fill pipe for both starboard and port fuel tanks, observed no electrical bonding between separated metal sections of this pipe. 46 CFR 182.20-30(d)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: Electrical bonding present now.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 23 October 2023 Resolved
Flexible hose runs shall be visible, easily accessible and shall not penetrate watertight bulkheads. Flexible hose run observed from starboard fuel tank penetrating aft watertight bulkhead to engine room. 46 CFR 182.20-40(a)(2)(i)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Replacement of flexible hose acceptable.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 23 October 2023 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Representing a significant fire hazard, observed battery start cable chaffing against port engine fuel line on the inboard side of the port engine.46 CFR 183.01-5(a)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Cable moved.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2023 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Portable fire extinguisher not properly secured in correct type of bracket in engine room. 46 CFR 181.30-10(b)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Approved bracket installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2023 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Observed improperly secured and exposed wires from bilge high level alarms to their respective junction boxes in the forepeak and in the engine room. 46 CFR 183.01-5(a)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Junction boxes suitable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2023 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. In cabinet containing CO2 pull remote pull station on main deck, several cable's sheathing is loose resulting exposed wires representing a fire hazard. 46 CFR 183.01-5(a)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: Sheathing tightened up. No more exposed wires.
01 - Certificates & Documentation › 013 - Documents › Declaration of AFS compliance
Issued 23 October 2023 Resolved
The marine employer shall ensure that all individuals engaged or employed on board a vessel are fully indoctrinated in the requirements of this subpart, and that appropriate vessel personnel are trained as necessary in the practical applications of these requirements. Vessel operator did not show evidence of entire crew's enrollment in a drug and alcohol program nor evidence of training to the crew on the program. 46 CFR 4.06-1(e)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: DAPT satisfactory
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2023 Resolved
An aggregate of more than 7.6 liters (two gallons) of flammable or combustible liquids stowed outside of an accommodation, control, or service space (other than a paint locker) or outside of a machinery space must be stowed in a paint locker that is marked with a warning sign indicating flammable or combustible liquid storage. Found an oxyacetylene bottle in a service locker and multiple pails of paint stored about the vessel all of which representing a fire hazard. 46 CFR 147.45
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: No more improperly stored flammables present.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 23 October 2023 Resolved
A vessel of not more than 19.8 meters (65 feet) in length is not required to carry a rescue boat unless: (1) The vessel carries passengers on an open or partially enclosed deck; and (2) The cognizant OCMI determines that the vessel is designed, arranged, or involved in operations so that the vessel itself cannot serve as an adequate rescue craft. Although authorized, the rescue platform is not properly secured to the vessel when deployed during a man overboard (MOB). Acting as a rescue boat in a man overboard, vessel will determine a way to more securely fasten the rescue platform to mitigate hazard to crew and increase effectiveness during a MOB. 46 CFR 180.210(b)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Rescue platform more securely mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2023 Resolved
The intent of this part is to insure ... that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Excessive amount of oil present on generator windings and pooled in winding casing representing a fire hazard. 46 CFR 182.01-5(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2023
Resolved 20 November 2023
Resolution: Windings cleaned.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 September 2022 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel is not logging the drills above.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2022
Resolved 7 November 2022
Resolution: Operator submitted sat evidence.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 September 2022 Resolved
A vessel at anchor shall exhibit where it can best be seen: (i) In the fore part, an all-round white light or one ball; (ii) At or near the stern and at a lower level than the light prescribed in paragraph (i) of this Rule, an all-round white light. Vessel's anchor light was found inoperable.
Action required: 705 - Other - as specified
Due 6 October 2022
Resolved 30 September 2022
Resolution: Operator submitted sat photograph of operable light.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 October 2021 Resolved
Fire pump pressure gauge not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 29 September 2022
Resolution: Cleared during annual inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 October 2021 Resolved
STBD shaft seal leaking excessively.
Action required: 705 - Other - as specified
Resolved 29 September 2022
Resolution: Cleared during annual inspection.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 4 October 2021 Resolved
46CFR182.115 (d): On or before March 11, 1999, an existing vessel must comply with the bilge high level alarm requirements in § 182.530. 46CFR182.530(b): Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers. Forepeak and rod locker required high level alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 29 September 2022
Resolution: Cleared during annual inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 April 2021 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. Rails shall consist of evenly spaced courses and the spacing between courses shall be not greater than 12 inches. On passenger decks of vessels engaged in a ferry or excursion type operation, rails shall be at least 42 inches high. The space below the rail shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivalent. The vessel has incomplete rails installed on the main (entire deck)and second decks(aft starboard quarter). Additionally, the vessel engages in excursion operations. On the main deck the space below the top rail is not equipped with bulwarks, chain link fencing, wire mesh, or the equivalent on the second deck the netting serving as an equivalent to bulwarks/chain link on the rails is torn and missing. 46 CFR 177.35-1
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2021
Resolution: Railings installed to the satisfaction of attending marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 16 April 2021 Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured before getting underway for a voyage on other than protected waters. The hatch to the entrance of the vessel's second compartment is cracked and is being moved by the operator to make the entrance to the #2 compartment from the interior of the vessel however this repair is not complete. 46 CFR 185.20-15
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2021
Resolution: Old hatch cover is permanently secured and new entrance installed to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 October 2020 Resolved
Each life buoy must be of an approved type, constructed in accordance with subpart 160,050 if this chapter. Life buoy on vessel was deteriorated and cracked. Replace life buoy. 46 CFR 180.30-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 6 October 2020
Resolution: Recieved photo of new ring buoy
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 October 2020 Resolved
All pyrotechnics distress signals shall be stowed in a portable water-tight container. Vessel pyrotechnics were not in watertight container. Provide watertight container for flares and label. 46 CFR 180.35-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 6 October 2020
Resolution: Recieved photo of new watertight container for flares
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 October 2020 Resolved
Vessel must carry either first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions and stowed in watertight container. Vessel had incorrect first aid kit. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 8 October 2020
Resolution: Received photo of new and approved first aid kit.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 March 2020 Resolved
Repairs or alterations to the hull or safety equipment of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Prior to carrying passengers submit a repair proposal for the following to the satisfaction of the attending marine inspector: make available for inspection newly installed hand rails on the vessel's bow.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2020
Resolved 29 May 2020
Resolution: Handrail repaired and checked by Sector NY personnel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 August 2019 Resolved
Post emergency instructions on bridge.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2019 Resolved
Generate DAPI folder with company policy.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 August 2019 Resolved
Vacuum out all PFD storage boxes.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2019 Resolved
Replace ROMEX wiring on top deck lighting with boat cable.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2019 Resolved
LED lighting above stbd entryway to main cabin - place wire connection in enclosure.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2019 Resolved
Life jacket signs shall be of contrasting colors.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019 Resolved
Provide portable bilge pump.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2019 Resolved
Update emergency broadcast placard.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019 Resolved
Label bilge system with water resistant placards. Permanently mount the placards.
Action required: 705 - Other - as specified
Due 3 October 2019
Resolved 3 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 August 2019 Resolved
Repair stbd engine RPM gauge in pilothouse.
Action required: 705 - Other - as specified
Due 3 October 2019
Resolved 3 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019 Resolved
Replace pool pump with approved marine grade pump.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019 Resolved
Replace PVC piping connecting non-PTO pump to bilge system with metallic piping.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019 Resolved
Provide lock and chain for sewage overboard valve.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019 Resolved
Provide marpol placard at overboard valve in engine room.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 14 April 2017 Resolved
The port side indepented diesel fuel tank is leaking. Operator needs to submit repair proposal and complete repairs to tank prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2018
Resolution: see narrative
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 June 2016 Resolved
1) Make first aid kit readily accessible and contents easily accessible.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 13 June 2016 Resolved
2) Replace 02 children's life jackets. Children's count limited to 07 until replaced.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Construction/Loadline › Hull › Bottom Plating
Issued 13 June 2016 Resolved
3) Properly repair opening in deck from fore peak space so as to make water tight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 June 2016 Resolved
4)Properly clean all battery terminals and clamps.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Construction/Loadline › Structures › End Bulkhead
Issued 13 June 2016 Resolved
5) Properly repair opening in forward engine room bulkhead so as to make water tight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Engineering › Fuel Oil Service System › Hose
Issued 13 June 2016 Resolved
6) Make non-metallic fuel lines no more than 30 inches in length and marine grade.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 13 June 2016 Resolved
7) Properly install double hose clamps on fresh water feed for port main engine.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 June 2016 Resolved
8) Properly install guards on port main engine fly wheel and both shaft couplings for rotating machinery in engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.