Records from 1985 to 2025. Most recent: inspection, 15 June 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 73
15 June 2025
Damage Survey · In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8159803
13 March 2025
Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8093439
3 December 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8011766
23 October 2023
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7798204
24 January 2023
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7626950
29 September 2022
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7568653
28 August 2022
Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 7545754
4 October 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7326515
30 April 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7186167
20 January 2021
Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7126788
5 October 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7070023
9 July 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7001565
19 March 2020
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6929264
1 August 2019
COI Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6768331
11 June 2019
COI Inspection · Administrative Inspection · DAPI Audit · Initial Certification · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6709742
17 April 2019
Simplified Stability Test
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6664866
19 June 2018
Examination of Repairs · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6448495
14 November 2017
Plan Review "T" Boat · Construction Oversight · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6307209
12 April 2017
In-Service Inspection · Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6123300
13 June 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5905741
30 March 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5843962
8 April 2009
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3448657
1 April 2009
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3444364
31 March 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3175408
4 April 2007
MARPOL Annex V Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2901776
28 March 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2897322
10 April 2006
Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2621327
2 July 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2118748
8 April 2004
Annual Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2039848
27 March 2003
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1763457
11 April 2002
Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1610834
11 April 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1445786
4 April 2001
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1468637
28 February 2001
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058356
26 February 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1059060
1 May 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 817010
7 April 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1391269
23 June 1999
Type not recorded
No type recorded · USCGC HAWSER (WYTL 65610) · USCG Northeast District (CGD-NE) · Activity 1505827
22 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 651668
15 June 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 810202
7 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 103921
31 March 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1451378
24 March 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1462735
12 March 1999
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 805218
22 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1462736
8 April 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1123265
25 March 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1445325
4 April 1997
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1091685
14 March 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1092688
29 March 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1083531
5 April 1995
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843137
29 March 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834256
6 April 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857864
30 March 1994
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857857
6 April 1993
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1145931
19 July 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 103715
8 April 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 952927
25 March 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1256516
3 April 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1211173
3 April 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245385
26 March 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1218808
30 March 1990
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1235900
18 April 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 888817
4 April 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 888082
21 March 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 888537
13 April 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340075
1 April 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328144
27 March 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328131
29 May 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993113
7 April 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 998878
1 April 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 998405
2 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1307445
29 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 982810
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 June 2025
No resolution recorded
The intent of this part is to insure that the scantlings, material, fastenings, workmanship, and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate inspection. Primary consideration shall be given the the provision of a seaworthy hull. Vessel sustained damage to PORT BOW in an approximate 9' x 5' area affecting hull planking, transverse and longitudinal framing, deck supports, and collision bulkhead. Submit repair proposal prior to commencing work satisfactory to attending Marine Inspector. Proposal and repair shall be approved/completed. Authorized a one-time voyage for perminant repairs at Sector CORAM.
46 CFR 177.01-5 "OLD-T"
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 June 2025
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed. MI discovered STBD Main Engine throttle linkage damaged, resulting in inability to control RPM from the operating station. Replace damaged throttle linkage and conduct satisfactory sea trial to satisfaction of attending Marine Inspector.
46 CFR 182.05-1 "OLD-T"
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 November 2025
Resolution: Throttle system repaird. Completed satisfactory sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2024
No resolution recorded
Exhaust gas must not leak from the piping or any connections. MI identified exhaust leak on port engine. Repair prior to credit dry dock.
46 CFR 182.430(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. MI identified no lifesaving donning placards posted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2025
Resolution: Received photos of lifejacket donning placards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. MI identified no separation between adult and children life jackets and adult life jackets were not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 March 2025
Resolution: Received photographs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 December 2024
Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. MI identified push button connected to the horn is missing, whistle is inoperable. Repair and label within 14 days.
33 CFR 83.33(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 March 2025
Resolution: Received photographs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2023
Resolved
Propulsion machinery shall be suitable in type and design... it is installed and capable of operating constant marine load. Observed starboard engine raw water leak on pipe to sea strainer with soft patch installed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Leaking pipe cut-out. Pay attention to mounting of flexible hose and sea water strainer. Not mounted securely
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2023
Resolved
...the inspection shall be such as to ensure that the vessel as regards main and auxiliary machinery... is in satisfactory condition and fit for service. Observed fuel leak on port main engine's forward fuel filter housing. 46 CFR 176.05-10(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Swapped filter
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2023
Resolved
...the inspection shall be such as to ensure that the vessel as regards main and auxiliary machinery... is in satisfactory condition and fit for service. Observed oil leak from filter on starboard main engine's inboard, forward side. 46 CFR 176.05-10(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Replaced gaskets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2023
Resolved
...the inspection shall be such as to ensure that the vessel as regards main and auxiliary machinery... is in satisfactory condition and fit for service. Observed fuel, oil, and jacket water leak on generator. Must clean for re-inspection by USCG inspector with generator running under load.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Plugged oil drain hose, replaced J/W hose which had a small leak, and cleaned drip pan.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 October 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system...Vessel's starboard ventilation closure does not operate as designed. Operator must prove proper operation upon re-inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Re-did fasteners and installed a rubber gasket for improved seal.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Observed lack of proper electrical wire isolation/removal of wires no longer in use. 46 CFR 183.01-15(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2023
Resolved 7 December 2023
Resolution: Junction box installed over exposed wires.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 October 2023
Resolved
Vessel must carry a either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel had expired items within first aid kit.
46 CFR 184.710
Action required: 10 - Deficiency Rectified
Resolved 23 October 2023
Resolution: Replaced expired eye wash
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 October 2023
Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Vessel's engine cooling water discharge temperature and lubricating oil pressure gauges do not function properly.
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Gauges function
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 October 2023
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked and clearly legible block capital letters with the vessel's name... Vessel had several lifejackets life that faded labeling and a two vessels' names on it. Lifejackets must have only one vessel's name. 46 CFR 185.604(b)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: Blacked out the second vessel's name in un-sat spots with sharpie. Re-did labelling in select lifejackets to "KEYPORT PRINCESS"
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2023
Resolved
Each floating water light must be approved in accordance with 161.010 and subchapter Q of this chapter or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Vessel ring buoy water light forward of the pilothouse is no longer water tight/operating as designed. The light's covering is broken and exposed to the elements.
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: Float light replaced with new unit.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 23 October 2023
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment
that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Observed overhead wire runs entirely by supported by plastic tie wraps a fire and personnel hazard. 46 CFR 183.01-5(a)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Metal electrical cable hangers installed all throughout ship
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 October 2023
Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or
near all pull boxes, stop valve controls and in the CO2 cylinder storage room... Vessel does have CO2 discharge instructions posted and the bottle locally or at pull station. 46 CFR 181.20-15(d)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Instructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 October 2023
Resolved
The painter must - Be stowed in such a way that it runs out freely when the life float or buoyant apparatus floats away from the sinking vessel. Vessel cannot use zip ties to keep the life float's painter lines tidy as they prevent them from floating freely. 46 CFR 180.15-5(c)(4)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: Painter lines now kept tidy with electrical tape. Painter line will float free.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 October 2023
Resolved
In accordance with Table 182.25-10(a), "S" vessels carrying more than 49 passengers and all "S" ferry vessels of 65 feet or less must have 1 fixed power pump and 1 portable hand pump. Vessel operator could not find portable hand pump at time of inspection. 46 CFR 182.25-10(a)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Bilge hand pump onboard
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 23 October 2023
Resolved
Where a flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used... the flexible section is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. With a flexible hose mid-section of the fuel fill pipe for both starboard and port fuel tanks, observed no electrical bonding between separated metal sections of this pipe. 46 CFR 182.20-30(d)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: Electrical bonding present now.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 23 October 2023
Resolved
Flexible hose runs shall be visible, easily accessible and shall not penetrate watertight bulkheads. Flexible hose run observed from starboard fuel tank penetrating aft watertight bulkhead to engine room. 46 CFR 182.20-40(a)(2)(i)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Replacement of flexible hose acceptable.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 23 October 2023
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment
that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Representing a significant fire hazard, observed battery start cable chaffing against port engine fuel line on the inboard side of the port engine.46 CFR 183.01-5(a)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Cable moved.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2023
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Portable fire extinguisher not properly secured in correct type of bracket in engine room. 46 CFR 181.30-10(b)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Approved bracket installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2023
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment
that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Observed improperly secured and exposed wires from bilge high level alarms to their respective junction boxes in the forepeak and in the engine room. 46 CFR 183.01-5(a)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Junction boxes suitable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2023
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment
that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. In cabinet containing CO2 pull remote pull station on main deck, several cable's sheathing is loose resulting exposed wires representing a fire hazard. 46 CFR 183.01-5(a)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: Sheathing tightened up. No more exposed wires.
01 - Certificates & Documentation › 013 - Documents › Declaration of AFS compliance
Issued 23 October 2023
Resolved
The marine employer shall ensure that all individuals engaged or employed on board a vessel are fully indoctrinated in the requirements of this subpart, and that appropriate vessel personnel are trained as necessary in the practical applications of these requirements. Vessel operator did not show evidence of entire crew's enrollment in a drug and alcohol program nor evidence of training to the crew on the program. 46 CFR 4.06-1(e)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: DAPT satisfactory
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2023
Resolved
An aggregate of more than 7.6 liters (two gallons) of flammable or combustible liquids stowed outside of an accommodation, control, or service space (other than a paint locker) or outside of a machinery space must be stowed in a paint locker that is marked with a warning sign indicating flammable or combustible liquid storage. Found an oxyacetylene bottle in a service locker and multiple pails of paint stored about the vessel all of which representing a fire hazard. 46 CFR 147.45
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 27 October 2023
Resolution: No more improperly stored flammables present.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 23 October 2023
Resolved
A vessel of not more than 19.8 meters (65 feet) in length is not required to carry a rescue boat unless: (1) The vessel carries passengers on an open or partially enclosed deck; and (2) The cognizant OCMI determines that the vessel is designed, arranged, or involved in operations so that the vessel itself cannot serve as an adequate rescue craft. Although authorized, the rescue platform is not properly secured to the vessel when deployed during a man overboard (MOB). Acting as a rescue boat in a man overboard, vessel will determine a way to more securely fasten the rescue platform to mitigate hazard to crew and increase effectiveness during a MOB. 46 CFR 180.210(b)
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 20 November 2023
Resolution: Rescue platform more securely mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2023
Resolved
The intent of this part is to insure ... that
the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to
afford adequate protection against fire, explosion, machinery failure and personnel injury. Excessive amount of oil present on generator windings and pooled in winding casing representing a fire hazard. 46 CFR 182.01-5(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2023
Resolved 20 November 2023
Resolution: Windings cleaned.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 September 2022
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel is not logging the drills above.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2022
Resolved 7 November 2022
Resolution: Operator submitted sat evidence.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 September 2022
Resolved
A vessel at anchor shall exhibit where it can best be seen: (i) In the fore part, an all-round white light or one ball; (ii) At or near the stern and at a lower level than the light prescribed in paragraph (i) of this Rule, an all-round white light. Vessel's anchor light was found inoperable.
Action required: 705 - Other - as specified
Due 6 October 2022
Resolved 30 September 2022
Resolution: Operator submitted sat photograph of operable light.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 October 2021
Resolved
Fire pump pressure gauge not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 29 September 2022
Resolution: Cleared during annual inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 October 2021
Resolved
STBD shaft seal leaking excessively.
Action required: 705 - Other - as specified
Resolved 29 September 2022
Resolution: Cleared during annual inspection.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 4 October 2021
Resolved
46CFR182.115 (d): On or before March 11, 1999, an existing vessel must comply with the bilge high level alarm requirements in § 182.530.
46CFR182.530(b): Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers.
Forepeak and rod locker required high level alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 29 September 2022
Resolution: Cleared during annual inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 April 2021
Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to
passengers and crews. Rails shall consist of evenly
spaced courses and the spacing between courses shall be not greater than 12 inches. On passenger decks of vessels engaged in a ferry or excursion type operation,
rails shall be at least 42 inches high. The space below the rail shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivalent. The vessel has incomplete rails installed on the main (entire deck)and second decks(aft starboard quarter). Additionally, the vessel engages in excursion operations. On the main deck the space below the top rail is not equipped with bulwarks, chain link fencing, wire mesh, or the equivalent on the second deck the netting serving as an equivalent to bulwarks/chain link on the rails is torn and missing. 46 CFR 177.35-1
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2021
Resolution: Railings installed to the satisfaction of attending marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 16 April 2021
Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured before getting underway for a voyage on other than protected waters. The hatch to the entrance of the vessel's second compartment is cracked and is being moved by the operator to make the entrance to the #2 compartment from the interior of the vessel however this repair is not complete. 46 CFR 185.20-15
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2021
Resolution: Old hatch cover is permanently secured and new entrance installed to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 October 2020
Resolved
Each life buoy must be of an approved type, constructed in accordance with subpart 160,050 if this chapter. Life buoy on vessel was deteriorated and cracked. Replace life buoy.
46 CFR 180.30-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 6 October 2020
Resolution: Recieved photo of new ring buoy
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 October 2020
Resolved
All pyrotechnics distress signals shall be stowed in a portable water-tight container. Vessel pyrotechnics were not in watertight container. Provide watertight container for flares and label.
46 CFR 180.35-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 6 October 2020
Resolution: Recieved photo of new watertight container for flares
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 October 2020
Resolved
Vessel must carry either first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions and stowed in watertight container. Vessel had incorrect first aid kit.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 8 October 2020
Resolution: Received photo of new and approved first aid kit.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 March 2020
Resolved
Repairs or alterations to the hull or safety equipment of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Prior to carrying passengers submit a repair proposal for the following to the satisfaction of the attending marine inspector: make available for inspection newly installed hand rails on the vessel's bow.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2020
Resolved 29 May 2020
Resolution: Handrail repaired and checked by Sector NY personnel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 August 2019
Resolved
Post emergency instructions on bridge.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2019
Resolved
Generate DAPI folder with company policy.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 August 2019
Resolved
Vacuum out all PFD storage boxes.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2019
Resolved
Replace ROMEX wiring on top deck lighting with boat cable.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2019
Resolved
LED lighting above stbd entryway to main cabin - place wire connection in enclosure.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2019
Resolved
Life jacket signs shall be of contrasting colors.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019
Resolved
Provide portable bilge pump.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2019
Resolved
Update emergency broadcast placard.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019
Resolved
Label bilge system with water resistant placards. Permanently mount the placards.
Action required: 705 - Other - as specified
Due 3 October 2019
Resolved 3 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 August 2019
Resolved
Repair stbd engine RPM gauge in pilothouse.
Action required: 705 - Other - as specified
Due 3 October 2019
Resolved 3 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019
Resolved
Replace pool pump with approved marine grade pump.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019
Resolved
Replace PVC piping connecting non-PTO pump to bilge system with metallic piping.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019
Resolved
Provide lock and chain for sewage overboard valve.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2019
Resolved
Provide marpol placard at overboard valve in engine room.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 4 September 2019
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 14 April 2017
Resolved
The port side indepented diesel fuel tank is leaking. Operator needs to submit repair proposal and complete repairs to tank prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2018
Resolution: see narrative
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 June 2016
Resolved
1) Make first aid kit readily accessible and contents easily accessible.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 13 June 2016
Resolved
2) Replace 02 children's life jackets. Children's count limited to 07 until replaced.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Construction/Loadline › Hull › Bottom Plating
Issued 13 June 2016
Resolved
3) Properly repair opening in deck from fore peak space so as to make water tight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 June 2016
Resolved
4)Properly clean all battery terminals and clamps.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Construction/Loadline › Structures › End Bulkhead
Issued 13 June 2016
Resolved
5) Properly repair opening in forward engine room bulkhead so as to make water tight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Engineering › Fuel Oil Service System › Hose
Issued 13 June 2016
Resolved
6) Make non-metallic fuel lines no more than 30 inches in length and marine grade.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 13 June 2016
Resolved
7) Properly install double hose clamps on fresh water feed for port main engine.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 June 2016
Resolved
8) Properly install guards on port main engine fly wheel and both shaft couplings for rotating machinery in engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 August 2016
Lifesaving › Lifefloat › Retroreflective Material
Issued 8 April 2009
Resolved
Replace retro tape on two life floats.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 9 April 2009
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 8 April 2009
Resolved
Replace two unservicable child size life jackets.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 9 April 2009
Construction/Loadline › Hull › Transverse Frame
Issued 1 April 2009
Resolved
Make permanent repairs to overhead transverse support in way of port and starboard MDEs.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 8 April 2009
Communications › Radio Communications › EPIRB
Issued 4 April 2007
Resolved
Renew EPIRB hydrostatic release.
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 17 April 2007
Lifesaving › Rocket Parachute Flares › General
Issued 4 April 2007
Resolved
Replace 03 expired orange flares.
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 17 April 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 April 2007
Resolved
Provide updated navigation publications onboard vessel.
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 17 April 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 April 2007
Resolved
Replace retro-tape on lifering.
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 17 April 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 4 April 2007
Resolved
Replace retro-tape on lifejackets as needed.
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 17 April 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 4 April 2007
Resolved
Place portable lighting (flashlight) at operating station.
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 17 April 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 April 2007
Resolved
Renew expired medications in first-aid kit.
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 17 April 2007
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 4 April 2007
Resolved
Properly label lifejackets as needed.
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 17 April 2007
Fire Fighting › Fire Pumps › Pressure
Issued 4 April 2007
Resolved
Prove proper operation of power driven fire pump to the sat of the attending CG MI.
Due 17 May 2007
Resolved 18 April 2007
Lifesaving › Lifefloat › Serviceable
Issued 4 April 2007
Resolved
Repair cracked/holed lifefloats to the sat of the attending CG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2007
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 10 April 2006
Resolved
Fresh water pump on starboard engine leaking.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 11 April 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 April 2006
Resolved
Light list and Coast Pilot outdated. Update/obtain current edition of USCG Light List and US Coast Pilot.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 18 April 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 April 2004
Resolved
Clean up and replace corroded wire connectors on P/S MDE start batteries
Due 9 May 2004
Resolved 8 April 2004
Resolution: Battery terminals reworked, sat.
Accommodation/Occupational Safety › Occupational Safety
Issued 8 April 2004
Resolved
Tighten both main and upper deck rails. LEGACY COMPONENT DESC: Deck Rail
Due 9 May 2004
Resolved 14 April 2004
Resolution: Observed installation of strengthening brackets on both decks, sat.
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 April 2004
Resolved
Replace 3 child lifjackets with dry rotted straps. Vsl retricted to carrying 6 children until new PFD's onboard. LEGACY COMPONENT DESC: Condition
Due 9 April 2004
Resolved 14 April 2004
Resolution: 3 child lifejackets replaced with new ones.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 8 April 2004
Resolved
Replace dry rotted raw water cooling hoses on port generator. LEGACY COMPONENT DESC: dry-rotted raw water cooling hoses
Due 9 April 2004
Resolved 14 April 2004
Resolution: Inspected installation of new raw water hoses on port gen.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 8 April 2004
Resolved
Replace wasted raw water cooling hose clamps. LEGACY COMPONENT DESC: raw water cooling hose clamps wasted
Due 8 April 2004
Resolved 8 April 2004
Resolution: Replaced.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 8 April 2004
Resolved
Replace missing double hose clamps on water injection hoses on port MSE exaust. LEGACY COMPONENT DESC: Wet Exhaust hose clamps missing
Due 8 April 2004
Resolved 8 April 2004
Resolution: Double clamped.
Documentation › Manuals/Policy Documentation
Issued 8 April 2004
Resolved
Provide current copy of Nav Rules. LEGACY COMPONENT DESC: NAV Rules
Due 9 May 2004
Resolved 14 April 2004
Resolution: New Nav Rules onboard.
Operations/Management › Drug and Alcohol Testing
Issued 11 April 2002
Resolved
Provide copy of employer's drug & alcohol policy & provide proof that supervisory personnel have received at least 60 minutes of training in regards to drug & alcohol program. LEGACY COMPONENT DESC: EAP Training Requirements
Due 10 May 2002
Resolved 9 May 2002
Resolution: Reviewed both - satisfactory.
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 April 2002
Resolved
Provide current U.S. Coast Pilot & Coast Guard Light List aboard vessel.
Due 18 April 2002
Resolved 1 May 2002
Resolution: Observed new USCP & CG Light List.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 11 April 2002
Resolved
Install vent closures to engine room vents. Closure devices must be readily available & mounted in the vicinity of the vent.
Due 10 May 2002
Resolved 1 May 2002
Resolution: Observed satisfactory vent closures.
Engineering › Bilge Water Management System
Issued 11 April 2002
Resolved
Install visible & audible indicators at operating station for bilge high level alarms in each protected space. LEGACY COMPONENT DESC: Visible/Audible Indicators
Due 10 May 2002
Resolved 1 May 2002
Resolution: Observed visible/audible indicators at op station for 3 protected spaces.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 11 April 2002
Resolved
Properly wire freezer located on aft stbd deck.
Due 10 May 2002
Resolved 9 May 2002
Resolution: Receptacle satisfactorily hard wired with AWG 12 boat cable.
Construction/Loadline
Issued 11 April 2002
Resolved
Vessel restricted to carrying not more than 16 passengers on upper deck forward of the "dodger." Submit proposal to [name withheld] addressing means to egress personnel from upper deck without requiring them to "hurdle the dodger."
Due 10 May 2002
Resolved 1 May 2002
Resolution: Access door cut into "dodger" with hinges. This will allow egress from upper deck without "hurdling the dodger."
Lifesaving
Issued 11 April 2001
Resolved
Properly attach bouyant apparatuses and lifefloats to painter.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Engineering
Issued 11 April 2001
Resolved
Fuel hose return line on port generator have clamps that rely solely on spring tension. Replace with correct clamps. Prove proper hose or replace hose equivalent to SAE standard J-1942.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Lifesaving
Issued 11 April 2001
Resolved
EPIRB located in pilothouse. Properly install EPIRB outside pilothouse.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Engineering
Issued 11 April 2001
Resolved
Fuel leak on copper tubing, port generator engine at discharge to fuel pump. Replace fitting or tubing to seal leak prior to operating engine.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Engineering
Issued 11 April 2001
Resolved
Replace fuel line between secondary fuel filter and fuel pump on port generator. Fuel line is deteriorated.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Lifesaving
Issued 11 April 2001
Resolved
Ring buoy must have waterlight attached using a corrosion resistant clip_x001C_ prior to embarking passengers.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Lifesaving
Issued 11 April 2001
Resolved
Floating lights for life floats and bouyant apparatus must be attached prior to embarking passengers.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Engineering
Issued 4 April 2001
Resolved
Renew stbd cutlass bearing and provide dye penetrant testing of shaft in way of suspected crevice corrosion.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Construction/Loadline
Issued 4 April 2001
Resolved
Make repairs to "Knee" on centerline in lazerette, below deck at aft_x001C_ boarding door.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Fire Fighting
Issued 7 April 2000
Resolved
Provide proof of annual servicing of fixed fire extinguishing system, IAW 46 CFR 176.810(b)(2).
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Documentation
Issued 7 April 2000
Resolved
Provide proof of valid CPR/First Aid Certification for 1 member of the vessel's crew, IAW NVIC 1-91.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Navigation
Issued 24 March 1999
Resolved
Provide 200mm (8") ships bell in accordance with 33CFR86.21 and Nav rules
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999
Lifesaving
Issued 24 March 1999
Resolved
Renew hydrostatic release for EPIRB.
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999
Electrical
Issued 24 March 1999
Resolved
Remove unapproved porcelain socket light blub/screw in plug receptacle and plug-in wiring for bilge pump in lazerette. Properly rewire lighting curcuit and bilge pump circuit.
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999
Electrical
Issued 24 March 1999
Resolved
Properly rewire bilge pump circuit plcing connections in receptacle box. Provide proper hard wire or UL grade receptacle for wet locations for temporary fan installation.
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999
Electrical
Issued 24 March 1999
Resolved
Remove household wire nuts in Controll Station and on port MDE alternator and properly rewire with UL marine grade crimp connectors
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999
Lifesaving
Issued 24 March 1999
Resolved
Provide rescue boat or suitable alternative acceptable to the OCMI in accordance with 46CFR180.210(b)(2)
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999
Fire Fighting
Issued 22 January 1999
Resolved
Vessel is not to be operated with passengers for hire after March 11, 1999,until the above requirements have been cleared to the satisfaction of an attending U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999
Fire Fighting
Issued 22 January 1999
Resolved
Install a Fixed Fire Fighting System in machinery spaces in accordance withU.S. Coast Guard approved plans.
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999
Fire Fighting
Issued 22 January 1999
Resolved
Submit plans for review and approval for the installation of a Fixed Fire Fighting System in the machinery spaces in accordance with 46 CFR 181.115(b) and 46 CFR 181.400
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Unknown
Issued 25 March 1998
Resolved
Post drug hotline "800" phone number.
Condition: Unknown
Due 25 March 1998
Resolved 25 March 1998
Documentation
Issued 25 March 1998
Resolved
Provide proof/logs of drills and training.
Condition: Unknown
Due 25 March 1998
Resolved 25 March 1998
Documentation
Issued 25 March 1998
Resolved
Provide garbage log.
Condition: Unknown
Due 25 March 1998
Resolved 25 March 1998
Electrical
Issued 25 March 1998
Resolved
Prove proper operation of emergency lighting system.
Condition: Unknown
Due 25 March 1998
Resolved 25 March 1998
Navigation
Issued 14 March 1997
Resolved
PAINT PYRO CONTAINER AND LABEL "DISTRESS SIGNALS"
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Navigation
Issued 14 March 1997
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Fire Fighting
Issued 30 March 1994
Resolved
REPLACE B-II DRY CHEMICAL PORTABLE FIRE EXIT IN MAIN CABIN IWO E/R LADDER (OR SERVICE/REFILL PRESENT ONE).
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Navigation
Issued 30 March 1994
Resolved
PROVIDE US COAST PILOT FOR WHEELHOUSE.
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Electrical
Issued 30 March 1994
Resolved
PROPERLY SPLICE ALTERNATER WIRE ON PORT ENG ALT.
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Electrical
Issued 30 March 1994
Resolved
PROPERLY SPLICE LUBE OIL SENSOR WIRE ON STBD ENG.
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Lifesaving
Issued 30 March 1994
Resolved
REPLACE RING BUOY FWD OF PILOTHOUSE AND ATTACHED LINE.
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Lifesaving
Issued 30 March 1994
Resolved
REPLACE GRAB LINED FOR 20 PERSON BUOYANT APPARATUS.
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Lifesaving
Issued 30 March 1994
Resolved
REPLACE PAINTER FOR BUOYANT APPARATUSES.
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Navigation
Issued 30 March 1994
Resolved
REPLACE BAR STOCK CONNECTORS IN STEERING GEAR LINKAGE WITH CLEVIS PINS.
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Lifesaving
Issued 8 April 1992
Resolved
PROVIDE WATERLIGHT FOR LIFERING. VESSEL RESTRICTED TO DAYTIME OPERATIONS UNTIL REQUIREMENT SATISFIED. ABOVE REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 May 1992
Resolved 6 May 1992
Engineering
Issued 8 April 1992
Resolved
MAKE AVAILABLE FOR CLOSE INSPECTION STBD SIDE WET EXHAUST ELBOW FITTING.
Condition: Unknown
Due 6 May 1992
Resolved 6 May 1992
Navigation
Issued 4 April 1989
Resolved
REPLACE RUNNING LIGHTS MAST AND STERN LIGHTS WITH 2 MILE CG. APPROVED NAV. LIGHTS.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Engineering
Issued 1 April 1986
Resolved
INSTALL FACTORY PROVIDED DAHL FIRE SHIELDS ON TWO (2) DAHL FUEL FILTERS IN ENGINE ROOM.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Construction/Loadline
Issued 1 April 1986
Resolved
REPAIR DOGS ON WATERTIGHT HATCHES ON MAIN DECK (2ND HAND 3RD AFT OF FOR- WARD).
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Construction/Loadline
Issued 2 April 1985
Resolved
PROVIDE PROTECTION FOR EXPOSED SECTION OF BILGE TUBING IN ENGINE ROOM.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Engineering
Issued 2 April 1985
Resolved
PROVIDE ONE VENT DUCT IN ENGINE ROOM WHICH EXTENDS TO THE BOTTOM OF ENGINE SPACE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Construction/Loadline
Issued 2 April 1985
Resolved
PROVIDE RESTRAINING DEVICES FOR ALL WEATHER DECK HATCHES.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985