Records from 1984 to 1996. Most recent: inspection, 26 February 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 97
26 February 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1080156
13 December 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425668
7 December 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 385699
19 October 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182541
1 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1183201
31 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 141472
13 April 1995
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 908945
14 March 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 829909
3 March 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 60098
24 August 1994
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1177807
1 July 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 24667
12 June 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 216384
9 May 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1168980
10 January 1994
Examination of Repairs · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1457144
11 December 1993
MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 836979
16 August 1993
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419152
2 April 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 33438
29 March 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1150091
4 February 1993
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1357992
29 January 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 961694
23 January 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1140063
5 December 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 72829
20 November 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1135405
12 November 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1134212
6 September 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 934629
2 September 1992
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 933067
4 August 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 178922
4 August 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 187214
27 July 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1265775
11 June 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 955550
8 June 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 950107
2 June 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 943469
22 May 1992
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1263279
21 April 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 956192
17 March 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261341
27 February 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1265294
5 February 1992
Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1448390
21 January 1992
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 943493
3 December 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317634
4 November 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245979
9 October 1991
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 934398
30 May 1991
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1219326
18 May 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 521674
15 May 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1217380
19 March 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 922124
15 March 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1225487
23 February 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1233653
31 December 1990
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 926013
8 October 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 225819
26 July 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236529
2 April 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987684
29 March 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1232314
25 March 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1220838
28 February 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 913866
11 January 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1244909
5 January 1990
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1221797
5 December 1989
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 915980
11 September 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032196
8 September 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 890959
19 August 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 513142
7 June 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198022
3 April 1989
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 890691
10 February 1989
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 895099
12 January 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 895009
13 December 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1209326
5 December 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1208058
22 November 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902159
22 November 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1213661
19 August 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1344761
9 June 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 893814
24 March 1988
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1195888
14 March 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1338614
11 January 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324426
28 October 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 468654
29 September 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320418
27 July 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1338915
20 July 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1334195
9 June 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311060
29 May 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029825
9 February 1987
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1018507
26 January 1987
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1313913
22 October 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 481974
20 August 1986
Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1295940
23 July 1986
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 991731
11 July 1986
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1294870
14 June 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 994820
12 March 1986
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 991765
6 March 1986
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1296325
13 February 1986
Credit Drydock · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 989099
16 November 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 305269
15 November 1985
Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 990535
16 August 1985
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1297630
8 August 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1295255
16 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984018
15 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983362
19 November 1984
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 976737
1 November 1984
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 975821
Fire Fighting
Issued 13 December 1995
Resolved
CONDUCT THE REQUIRED SERVICING OF ALL FIREFIGHTING EQUIPMENT NO LATER THAN FEBRUARY 28, 1996.
Condition: Unknown
Due 28 February 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 14 March 1995
Resolved
SUBMIT FOR APPROVAL TO [name withheld], PLAN FOR MODIFIED BALLAST SYSTEM.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Accommodation/Occupational Safety
Issued 14 March 1995
Resolved
SERVICE VESSEL'S ELEVATOR AND PROVIDE A COPY OF SERVICING REPORT TO [name withheld].
Condition: Unknown
Due 15 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 14 March 1995
Resolved
REPLACE E-GEN STARING BOX RELAYS WITH PROPERLY FITTING SPARE PARTS.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Electrical
Issued 14 March 1995
Resolved
REPLACE FUSE COVER FOR F10 (ON INBOARD SIDE OF EMERGENCY SWITCHBOARD).
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Accommodation/Occupational Safety
Issued 14 March 1995
Resolved
INSTALL MISSING VENTILATION DIFFUSER COVERS IN GALLEY OVERHEAD.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Engineering
Issued 14 March 1995
Resolved
REPACK BOTH SETS OF GLANDS FOR WATER-END OF NO.2 MAIN FEED PUMP.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Fire Fighting
Issued 14 March 1995
Resolved
PROVIDE TWO FLAME SAFETY LAMPS OR EQUIVALENT.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Lifesaving
Issued 14 March 1995
Resolved
RENEW LAGGING AS NECESSARY THROUGHOUT MAIN MACHINERY SPACE.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Deck/Cargo
Issued 14 March 1995
Resolved
REPAIR HYDRAULIC LEAK IWO PORT ANCHOR WINDLASS.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Fire Fighting
Issued 14 March 1995
Resolved
PROVE PROPER OPERATION OF NO.3 FOAM MONITOR.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Lifesaving
Issued 14 March 1995
Resolved
SUBMIT FOR APPROVAL TO [name withheld], LIFE SAVING ARRANGEMENT PLAN.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Fire Fighting
Issued 14 March 1995
Resolved
REPAIR WASTED FIRE MAIN BRACKETS FORWARD OF NO.5 CARGO HATCH.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Engineering
Issued 14 March 1995
Resolved
REPAIR OR REPLACE SNUBBER FOR MAIN STERM LINE AFT OF NO.1 BOILER.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Electrical
Issued 14 March 1995
Resolved
REPLACE E-GEN LUBE OIL PRESSURE SWITCH WITH PROPER SPARE PARTS.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Electrical
Issued 11 December 1993
Resolved
Provide two electrial outlet covers, external 'A' deck aft._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
Properly secure loose cable near fire extinguisher # 6._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
Properly secured loose cable at light above stb 'U' deck house access._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Fire Fighting
Issued 11 December 1993
Resolved
Provide handle and prove proper operation cut off valve for sta # 3 on maindeck._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Documentation
Issued 11 December 1993
Resolved
Provide copy of approved safety plan for vessel._x001C_
Condition: Unknown
Due 11 December 1993
Resolved 11 December 1993
Accommodation/Occupational Safety
Issued 11 December 1993
Resolved
Remove all high pressure cylinders (oxygen & acetylene) which are not approved by U.S. DOT. or the international maritime organization, dangerousgoods code (IMDG)._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Fire Fighting
Issued 11 December 1993
Resolved
HYDROSTATICALLY TEST ALL SCBA BOTTLES IN ACCORDANCE WITH D.O.T. SPECIFICATIONS.
Condition: Unknown
Due 11 December 1993
Resolved 11 December 1993
Electrical
Issued 11 December 1993
Resolved
RENEW OR REPAIR BROKEN LATCHES ON THE POWER PANEL P1,P2 AND POWER PANEL ON SECOND LEVEL IN ENGINE ROOM ON FORWARD BULKHEAD NEAR EVAPORATOR.
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Construction/Loadline
Issued 11 December 1993
Resolved
Properly align vent closure for focsle deck stb aft vent._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Construction/Loadline
Issued 11 December 1993
Resolved
Install screen for vent closure on stb vent line, aft of hold # 9._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Deck/Cargo
Issued 11 December 1993
Resolved
Label all vents, trunks and hatches with correct and sufficient identification._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Construction/Loadline
Issued 11 December 1993
Resolved
Provide closure for vent, port side just forward of lifeboat davit._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Engineering
Issued 11 December 1993
Resolved
Provide closure for vent for port fuel oil settling tank vent._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
Remove dead end cables in crows nest on mast._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
Properly secured cables on mast riser with metal securing devises._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Deck/Cargo
Issued 11 December 1993
Resolved
Provide documentation of purchase of new mooring lines or present new lineson board._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
REWIRE PORTABLE CONTROL FOR TURNING GEAR, THE CABLE HAS LOST ITS OUTER SHIELD AND HAS EXPOSED THE WIRES FOR THE CONTROL._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Lifesaving
Issued 11 December 1993
Resolved
HYDRO TEST BOTH EEBA'S IN THE ENGINE ROOM, BOTH BOTTLES ARE PAST THE FIVE YEAR REQUIREMENT._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Construction/Loadline
Issued 11 December 1993
Resolved
Renew wasted ear pieces on stb vent line between holds # 8 and # 9._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
REPAIR STEAM GENERATOR LOW PRESSURE ALARM, SHUT DOWN WORKS WITH NO ALARM._x001C_
Condition: Unknown
Due 11 December 1993
Resolved 11 December 1993
Engineering
Issued 11 December 1993
Resolved
REPAIR FOUR BROKEN BRACKETS ON FEED WATER PIPING SYSTEM, THE BRACKETS ARE LOCATED NEAR THE ENGINE ROOM CONSOLE THREE ABOVE THE CONSOLE DECK AND ONE BELOW.
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Engineering
Issued 11 December 1993
Resolved
REPAIR VALVE FOR # 1 MAIN CIRC PUMP, TO SHOW INDICATION OF VALVE POSITION AS TO OPEN OR CLOSED._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Construction/Loadline
Issued 11 December 1993
Resolved
Renew wasted ear pieces on stb vent line between hold # 6 and# 7._x001C_
Condition: Unknown
Due 11 December 1993
Resolved 11 December 1993
Electrical
Issued 11 December 1993
Resolved
REPAIR ALARM INDICATOR LIGHTS FOR EMERGENCY GENERATOR ALARM PANEL IN EMERGENCY GENERATOR ROOM, ENSURE LIGHTS PROVIDE PROPER OPERATION._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Engineering
Issued 11 December 1993
Resolved
INSTALL PROPER SPRING COVER PLATES ON THE FOLLOWING BOILER SAFETY VALVES FOR THE STB BOILER, SUPERHEATER AND DRUM PILOT VALVE. BOTH VALVES WILL NEEDTO BE RESEALED AFTER REPAIRS.
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Fire Fighting
Issued 11 December 1993
Resolved
REPAIR FIRE DAMPER LOCATED ON STB SIDE MAIN DECK, PROVIDE PROPER MOUNTING FOR HOLDING DAMPER OPEN AND CLOSED._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Lifesaving
Issued 11 December 1993
Resolved
INSTALL INLET SCREEN ON ENGINE ROOM BLOWER ON STB SIDE MAIN DECK, OLD SCREEN IS WASTED._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
REPAIR SHORE POWER BOX ON MAIN DECK TO BE WATER TIGHT. BOX IS MISSING SCREWS AND IS NOT DOGGED PROPERLY._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
REMOUNT SUPPLY POWER CABLE FOR STERN DECK LIGHT, CABLE RUN HAS FOUR BROKEN BRACKETS AND WIRE IS LOOSE ON DECK._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
REPAIR LIGHT FIXTURE LOCATED OVER MAIN SWITCH, FIXTURE IS MISSING COVER._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
RENEW OR REPAIR THE FOLLOWING GAUGES ON THE STEAM GENERATOR, RPM, OIL TEMP(4) AND GLAND SEAL. THE ABOVE GAUGES ARE NOT READING PROPERLY._x001C_
Condition: Unknown
Due 11 December 1993
Resolved 11 December 1993
Accommodation/Occupational Safety
Issued 11 December 1993
Resolved
RENEW AND REPAIR WASTED AND HOLED DECK PLATES IN PUMP ROOM._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
REPAIR SOUND POWERED PHONE AT CONSOLE PHONE BOOTH TO ORGINIAL PRINT, ALARM AND WIRING HAS BEEN MODIFIED, ENSURE SYSTEM IS WORKING PROPERLY. _x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
PROVIDE LIGHTING FOR LIFE BOATS AND LIFE RAFTS STORAGE AREA AND EMBARKATIONAREA FROM A EMERGENCY POWER SUPPLY._x001C_
Condition: Unknown
Due 17 December 1993
Resolved 17 December 1993
Engineering
Issued 11 December 1993
Resolved
REPLACE MISSING PIPE BRACKETS ON PORT BOILER DESUPERHEATER LINE AND EXHAUSTPIPING FROM MAIN DRUM SAFETY VALVE._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Construction/Loadline
Issued 11 December 1993
Resolved
Renew the following gaskets, #2, 3 and 5 hole forward accress hatch and #7hold forward and aft access hatches. _x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Construction/Loadline
Issued 11 December 1993
Resolved
Repair hatch coaming on # 5 center hold access._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Construction/Loadline
Issued 11 December 1993
Resolved
Renew wasted vent pipe for forward peak tank._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Construction/Loadline
Issued 11 December 1993
Resolved
Renew wasted ear pieces on port ballast vent line between holds # 5 and #6._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Accommodation/Occupational Safety
Issued 11 December 1993
Resolved
Provide proper operation of ship's elevator. Elevator is to be secured fromuse until satisfied._x001C_
Condition: Unknown
Due 11 December 1993
Resolved 11 December 1993
Construction/Loadline
Issued 11 December 1993
Resolved
Renew wasted vent piping on port ballast vent line between holds # 7 and #_x001C_8. Soft patch not acceptable._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Accommodation/Occupational Safety
Issued 11 December 1993
Resolved
Provide ventilation diffuser in hospital space._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Deck/Cargo
Issued 11 December 1993
Resolved
Submit approved plans of cargo piping in its current layed-up configuration._x001C_
Condition: Unknown
Due 11 December 1993
Resolved 11 December 1993
Construction/Loadline
Issued 11 December 1993
Resolved
Renew wasted ear pieces on # 2 stb ballast tank aft vent._x001C_
Condition: Unknown
Due 11 December 1993
Resolved 11 December 1993
Electrical
Issued 11 December 1993
Resolved
Prove proper operation of all lights with proper globes, in the elevator_x001C_ machinery room._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Unknown
Issued 11 December 1993
Resolved
Hydrostatically test all oxygen bottles beyond 5 years from last hydro date._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Accommodation/Occupational Safety
Issued 11 December 1993
Resolved
Provide and prove proper operation of door knob and door latch for 'U' deckfan room._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Lifesaving
Issued 11 December 1993
Resolved
Remove welded steel trip hazard from deck aft of # 1 stb hatch._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Fire Fighting
Issued 11 December 1993
Resolved
Provide approved 50'x2 1/2" fire hoses at all stations where required by fire control plan. 75' hoses are then to be removed. If amendments to the fire control plan is desired, amendments are to be submitted for approval prior to actual reconfiguration._x001C_
Condition: Unknown
Due 11 December 1993
Resolved 11 December 1993
Electrical
Issued 11 December 1993
Resolved
Provide proper mounting brackets and positioning fixtures for all non-fixedlifeboats and liferafts lights, these shall not require tools to adjust aimof light and be secured in all positions._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
RENEW BREAKER FOR # 1 MAIN CIRC PUMP ON MAIN BOARD. BREAKER HAS BROKEN TAB._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Accommodation/Occupational Safety
Issued 11 December 1993
Resolved
RENEW SINK IN RESTROOM IN ENGINE ROOM. SINK HAS A SIX INCH HOLE IN IT._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
REPLACE ELECTRICAL BOX COVER ON STB FAN MOTOR, LOCATED ON MAIN DECK, COVER IS MISSING._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Fire Fighting
Issued 11 December 1993
Resolved
RENEW FIRE SCREEN DOOR FOR MACHINERY STORAGE ROOM TO MAIN PASSAGE WAY, DOORIS WASTED AND HOLED._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Engineering
Issued 11 December 1993
Resolved
MAKE PERMANENT REPAIRS TO BOILER VENT PIPING IN UPPER STACK, PIPE IS WASTEDAND HOLED._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Engineering
Issued 11 December 1993
Resolved
PROPERLY MOUNT FUEL FILTER ASSEMBLY FOR AUX DIESEL GENERATOR, THE BRACKET IN USE NOW ALLOWS TO MUCH MOVEMENT._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
RENEW OR REPAIR LIGHTING FIXTURES THROUGH OUT ENGINE ROOM, LIGHTING FIXTURES ARE MISSING COVERS OR ARE NOT WORKING._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
RENEW BATTERY CHARGER VOLT METER ON THE EMERGENCY SWITCH BOARD. METER HAS BROKEN FRONT COVER._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
RENEW INDICATOR LIGHTS FOR # 1 FORCE DRAFT BLOWER CONTROLER. LIGHTS AND COVER IS BROKE OFF._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
INSTALL BRACKET FOR POWER CABLE TO # 2 CIRC PUMP MOTOR, CABLE IS SUPPORTED NOW BY A LINE. _x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
REPAIR SLIGHT LUBE OIL LEAK ON THE STEAM GENERATOR AROUND LUBE OIL STRAINER._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Electrical
Issued 11 December 1993
Resolved
PROVIDE PROPER AND PERMANENT LABELS FOR STEAM TURBINE GENERATOR GAUGES AND CONTROLS._x001C_
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Engineering
Issued 23 January 1993
Resolved
MAKE TEMPORARY REPAIRS TO DC HEATER RELIEF VALVE EXHAUST PIPING IN FAN ROOM.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Engineering
Issued 23 January 1993
Resolved
RENEW RESET BUTTONS ON FOLLOWING MOTOR CONTROLLERS: DISTILLER 4P3 AND 3P3; MACHINE SHOP 6P5 AND 2P5; COLD BOILER START PUMP.
Condition: Unknown
Due 23 January 1993
Resolved 23 January 1993
Electrical
Issued 23 January 1993
Resolved
PROVIDE(REPLACE) PROPERLY RATED ELECTRICAL MATTING IN FRONT OF EMERGENCY DIESEL GENSET SWITCHBOARD.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Engineering
Issued 23 January 1993
Resolved
PROVIDE PRESS/TEMP (100PSI/210F) RELIEF VALVE ON ELECTRIC HOT WATER TANK ORMAKE AVAILABLE FOR INTERNAL INSPECTION BY USCG INSPECTOR.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Electrical
Issued 23 January 1993
Resolved
FREE-UP AND PROVE PROPER OPERATION OF EMERGENCY GENERATOR RADIATOR VENT LOUVERS.
Condition: Unknown
Due 23 January 1993
Resolved 23 January 1993
Engineering
Issued 23 January 1993
Resolved
RENEW BROKEN GLASS SAMPLING TUBE ON OWS MONITOR.
Condition: Unknown
Due 23 January 1993
Resolved 23 January 1993
Construction/Loadline
Issued 23 January 1993
Resolved
RENEW DISTORTED EXPANSION JOINT AT BALLAST PUMP STEAM RETURN TO CONDENSOR.
Condition: Unknown
Due 23 January 1993
Resolved 23 January 1993
Electrical
Issued 23 January 1993
Resolved
REPAIR AUXILARY DIESEL GENSET EXHAUST LEAK AT TURBO CONNECTION.
Condition: Unknown
Due 23 January 1993
Resolved 23 January 1993
Navigation
Issued 23 January 1993
Resolved
REPLACE STERN LIGHT WITH PROPER MARINE APPROVED SOCKET AND BULB PRIOR TO DEPARTING THE PORT OF NEW ORLEANS.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Electrical
Issued 23 January 1993
Resolved
MAKE PERMANENT REPAIRS TO WIRING FOR WINCH #3 MIDSHIPS, AND REMOVE OR REPAIR ALL ELECTRICAL WIRING AND FIXTURES IN HAZARDOUS AREAS IN ACCORDANCE WITH 46CFR111.105 PRIOR TO DEPARTING THE PORT OF NEW ORLEANS.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Electrical
Issued 23 January 1993
Resolved
BLANK OFF MISSING BREAKERS IN B DECK PANEL L6 AND GALLEY PANEL P10.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Deck/Cargo
Issued 23 January 1993
Resolved
DISABLE ALL CARGO AND IGS PIPING SYSTEMS PRIOR TO DEPARTING THE PORT OF NEWORLEANS.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Engineering
Issued 23 January 1993
Resolved
PER SEALIFT EXTENSION LTR DTD 21JAN93, MAKE DC HEATER AVAILABLE FOR INTERNAL INSPECTION BY USCG AND TEST RELIEF/SAFETY VALVE.
Condition: Unknown
Due 23 January 1993
Resolved 23 January 1993
Electrical
Issued 23 January 1993
Resolved
RENEW/RECALIBRATE ALL GAUGES ON STEAM TURBINE GENSET.
Condition: Unknown
Due 23 January 1993
Resolved 23 January 1993
Electrical
Issued 23 January 1993
Resolved
REPLACE GLASS IN EMERGENCY SHUTDOWN STATIONS FOR AUX. GENSET AND EMERGENCY GENSET PRIOR TO DEPARTING THE PORT OF NEW ORLEANS.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Engineering
Issued 23 January 1993
Resolved
PER SEALIFT EXTENSION LTR DTD 21JAN93, MAKE BOILER MOUNTINGS REMOVAL AVAILABLE FOR USCG INSPECTION IAW 46 CFR 61.05-15(b)(c).
Condition: Unknown
Due 23 January 1993
Resolved 23 January 1993
Engineering
Issued 23 January 1993
Resolved
CROP AND RENEW WASTED AREA OF SALTWATER COOLING PIPE JUST AFT OF OILY WATERSEPERATOR.
Condition: Unknown
Due 23 January 1993
Resolved 23 January 1993
Electrical
Issued 23 January 1993
Resolved
HARDPIPE FUEL SYSTEM LEADING FROM AUXILARY DIESEL GENSET RACOR FUEL FILTERSTO ENGINE (MINIMIZE FLEXIBLE HOSE LENGTH).
Condition: Unknown
Due 23 January 1993
Resolved 23 January 1993
Engineering
Issued 23 January 1993
Resolved
PER SEALIFT EXTENSION REQUEST DTD 21JAN93, MAKE PORT AND STBD BOILERS AVAILABLE FOR FIRESIDE AND WATERSIDE EXAMINATIONS BY USCG INSPECTORS.
Condition: Unknown
Due 23 January 1993
Resolved 23 January 1993
Deck/Cargo
Issued 2 September 1992
Resolved
PROVE PROPER OPERATION OF PORT ANCHOR WINDLASS (HYDAULIC UNIT) TO SATIFACTION OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Engineering
Issued 2 September 1992
Resolved
PROVE PROPER OPERATION OF STBD BOILER (PROPULSION) TO SATISFACTION OF ATTENDING C.G. INSPECTOR.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Unknown
Issued 11 June 1992
Resolved
CORRECT THE VESSEL NAME ON ALL FIREFIGHTING AND LIFESAVING EQUIPMENT TO REFLECT THE PRESENT NAME. PRIOR TO DEPARTURE FROM THE PORT OF NEW ORLEANS.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Engineering
Issued 3 December 1991
Resolved
Replace #1 and #2 30" diameter swing check valves between main ciculating pumps and main condenser as per 46 CFR 31.10-15 (b).
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Construction/Loadline
Issued 3 December 1991
Resolved
COMPLETE REPAIRS IN FOREPEAK VOID TANK BREAST HOOK PLATING WHERE FRACTURES OCCUR, PRIMARILY LOCATED FWD OF FRAME 5, 31FOOT LEVEL, ALSO TWO(2) SUPPORT FRAMES PORTSIDE BETWEEN FRAMES 5 & 10 AND ALSO PORT SIDE INTERMEDIATE FLOOR, JUST UNDER 31 FOOT LEVEL (APPRX 37 FOOT LEVEL)
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Construction/Loadline
Issued 3 December 1991
Resolved
INSPECT AND REPAIR AS NECESSARY ALL CARGO HOLD ACCESS HATCH COVER HINGES LOCATED BETWEEN CARGO HOLDS. (SEVERAL COVERS HELD IN PLACE BY HINGES ONLY)
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Construction/Loadline
Issued 3 December 1991
Resolved
REPAIR #6 FWD HATCH ACCESS COVER COMBING. (COMBING WASTED BUT GASKET CURRENTLY INTACT AND INPLACE)
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Engineering
Issued 3 December 1991
Resolved
Repair boiler casing as per original on Port and Stbd boiler bottoms and sides in accordance with 46 CFR 31.10-15 (b).
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Construction/Loadline
Issued 3 December 1991
Resolved
COMPLETE FOLLOWING REPAIRS IN THE #7 PORT BALLAST TANK; RENEW VERTICAL STIFFNER AFTER BLKH LOWER LEVEL, INSERT THREE EASTED UNDER DECK LONG'S-FWD BULKHEAD.
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Construction/Loadline
Issued 3 December 1991
Resolved
COMPLETE REPAIRS IN THE #8 PORT/STBD BALLAST TANKS AS FOLOWS; (P)-REBEW #1,2,3,4&5 DIAGONAL STIFFNERS-AFT BLKD,INSERT 3 UNDER DECK LONG'S & 1 VERT.STIFFNER (S)-INSERT UNDER CARGO DECK LONG'S FWD UPPER INWAY OF LADDER, 1 VERT. STIFFNER AFT LWR BLKD AND REWELD DIAGONALS # 2,3&4.
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Deck/Cargo
Issued 3 December 1991
Resolved
PRIOR TO LOADING ANY GRADE 'B' OR LOWER CARGOES, CONDUCT OPERATIONAL TEST TO CARGO PUMPS 1,2&3 REMOTE STOPS. AN OPERATIONAL TEST TO BE CONDUCTED AND WITNESSED BY VLS'S MASTER, LOGGED IN OFFICAL LOG AND FORWARD AFFADAVIT TO [name withheld].
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Construction/Loadline
Issued 3 December 1991
Resolved
REPAIR CREWS WASHROOM PORT LIGHT LOCATED ON 'U' DECK, STBD SIDE. DEAD COVERTO REMAIN CLOSED AND DOGGED WHILE UNDERWAY UNTIL REPAIRSARE COMPLETED.
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Lifesaving
Issued 3 December 1991
Resolved
PROVIDE ONBOARD VESSEL THREE(3) SOLAS 74/83 APPROVED PORTABLE LIFEBOAT RADIO'S. RETAIN CURRENT L/B EMERGENCY RADIO ONBOARD AFTER PROVIDING SOLAS_x001C_ RADIO'S TO MEET CURRENT REGULATIONS.
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Electrical
Issued 3 December 1991
Resolved
repair the followinig electrical controller reset panel buttons; Cargo hatch cover #1, Cargo winch #2 & #2 topping winch.
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Construction/Loadline
Issued 3 December 1991
Resolved
REPLACE MISSING WATER TIGHT DOOR DOGS FOR THE MAIN DECK, AFTER END OF MAIN HOUSE CREWS HEAD.
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Construction/Loadline
Issued 19 March 1991
Resolved
This modifies NYCMI item6, their MI91000605. Demonstrate proper welding of upper seam of insert between balolast tanks 6 & 7 Port, 14' above keel.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Construction/Loadline
Issued 23 February 1991
Resolved
PRIOR TO DEPARTURE FROM THE UNITED STATES, CROP AND INSERT BACK TO SOUND STEEL THE WASTED AND FRACTURED WATERTIGHT BULKHEAD BETWEEN BALLAST TANKS 6 AND 7 PORT, LOWER LEVEL, APPROXIMATELY 14 FEET ABOVE THE BOTTOM OF THE VESSEL.
Condition: Unknown
Due 23 February 1991
Resolved 23 February 1991
Construction/Loadline
Issued 23 February 1991
Resolved
PROVIDE THE OFFICER IN CHARGE, MARINE INSPECTION OFFICE NEW YORK, WITH A COPY OF THE GAUGINGS ALONG WITH ORIGINAL SCANTLINGS THAT WERE TAKEN DURING DRYDOCK IN SETUBAL, PORTUGAL, THE MONTH OF FEBRUARY 1991.
Condition: Unknown
Due 23 February 1991
Resolved 23 February 1991
Deck/Cargo
Issued 23 February 1991
Resolved
PRIOR TO THE CARRIAGE OF ANY OIL AS CARGO ABOARD THIS VESSEL, THE BELOW LISTED REPAIRS & TEST ARE TO BE ACCOMPLISHED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR; (A) REPAIR SOUNDING TUBES & PROVE PROPER OPERATION OF THE WASTE OIL TANKS PORT & STARBOARD. (CONT'D)
Condition: Unknown
Due 23 February 1991
Resolved 23 February 1991
Deck/Cargo
Issued 23 February 1991
Resolved
(B)MAKE PERMANENT REPAIRS TO THE VENT LINES, & INSTALL FLAMES SCREENS & CLOSURES WHERE NEEDED ON THE IGS SYSTEM. (C)OVERHAUL P/V VALVES, INSTALL PROPER SCREENS & (D) HYDROTEST ALL PIPING A& DEMONSTRATE PROPER OPERATION OF ALL CARGO VALVES. (E)THE OIL POLLUTION MONITORING SYSTEM LOCATED WITHIN
Condition: Unknown
Due 23 February 1991
Resolved 23 February 1991
Lifesaving
Issued 23 February 1991
Resolved
PRIOR TO DEPARTURE FROM THE U.S., DROP TEST BOTH EMBARKATION LADDERS TO THEPORT AND STARBOARD LIFEBOATS, INSURING PROPER STRENGTH. IF NOT UP TO PROPER STRENGTH, REPLACE WITH APPROVED LADDERS.
Condition: Unknown
Due 23 February 1991
Resolved 23 February 1991
Fire Fighting
Issued 23 February 1991
Resolved
PRIOR TO DEPARTURE FROM THE UNITED STATES, PROPERLY REPAIR THE MAIN FIRE PUMP ELECTRICAL MOTOR TO INSURE THAT PUMP RUNS WITHOUT TRIPPING OF MAIN CIRCUIT BOARD.
Condition: Unknown
Due 23 February 1991
Resolved 23 February 1991
Engineering
Issued 23 February 1991
Resolved
PRIOR TO DEPARTURE FROM THE US, TEST IN THE PRESENCE OF A USCG MARINE INSPECTOR THE AUTOMATION FOR THE ENGINEROOM-THIS IS EXTENDING CG835 ISSUED BY GALVESTON ON 31 DEC 91, NUMBER 6. TO INCLUDE PROPER OPERATION OF THE HIGH AND LOW ALARMS FOR THE PORT FUEL OIL SETTLING TANK.
Condition: Unknown
Due 23 February 1991
Resolved 23 February 1991
Fire Fighting
Issued 23 February 1991
Resolved
PRIOR TO DEPARTURE FROM THE UNITED STATES, REPLACE THE WASTES SECTIONS OF FIRE MAIN ALONG THE MAIN DECK, IN THE AREA OF NUMBER 1,2 AND 4 HATCH. AFTER REPLACING, PRESSURE TEST TO 150 PSIG WITH WATER.
Condition: Unknown
Due 23 February 1991
Resolved 23 February 1991
Construction/Loadline
Issued 23 February 1991
Resolved
AS AUTHORIZED BY THE [name withheld], CARRY OUT THE PROGRAMMED REPAIRS ON THE VSL BY THE REPLACEMENT OF THE VARIOUS FRACTURED AND/OR WASTED STEEL FOUND WITHIN THE FOREPEAK & THE VARIOUS BALLAST TANKS-UPPER & LOWER, PORT & STARBOARD. ALL DEEP WEBS TO BE REPAIRED NOT LATER THAN 31AUG91, (CONT'D)
Condition: Unknown
Due 23 February 1991
Resolved 23 February 1991
Construction/Loadline
Issued 23 February 1991
Resolved
ALONG WITH AN ESTIMATED 50% OF ALL OTHER STEEL WORK. ALL REPAIRS TO BE COMPLETED NO LATER THAN 28 FEBRUARY 1992. SEE WORLIST OF 26 FEB 91 TO GIVE IDEA OF WORK TO BE ACCOMPLISHED.
Condition: Unknown
Due 23 February 1991
Resolved 23 February 1991
Lifesaving
Issued 31 December 1990
Resolved
END FOR END AND CONDUCT WEIGHT TEST ON PORT AND STBD LIFEBOATS AND CABLES.
Condition: Unknown
Due 31 December 1990
Resolved 31 December 1990
Fire Fighting
Issued 31 December 1990
Resolved
PROVIDE [name withheld] WITH A COPY OF THE CURRENT FOAM ANALYSIS.
Condition: Unknown
Due 31 December 1990
Resolved 31 December 1990
Engineering
Issued 31 December 1990
Resolved
PROVE PROPER OPERATION OF BOILER AUTOMATION.
Condition: Unknown
Due 31 December 1990
Resolved 31 December 1990
Lifesaving
Issued 31 December 1990
Resolved
REPLACE ALL RING BOUY LINES WITH FLOATING LINE.
Condition: Unknown
Due 31 December 1990
Resolved 31 December 1990
Engineering
Issued 31 December 1990
Resolved
OPEN AND PRESENT FOR CG INSPECTOR THE DC HEATER.
Condition: Unknown
Due 31 December 1990
Resolved 31 December 1990
Electrical
Issued 31 December 1990
Resolved
REPLACE NON-CONDUCTIVE MAT BEHIND SHIP'S SWITCHBOARD.
Condition: Unknown
Due 31 December 1990
Resolved 31 December 1990
Engineering
Issued 25 March 1990
Resolved
HAVE TUG OF ADEQUATE HORSEPOWER IN ATTENDANCE AT ALL TIMES UNTIL VESSEL IS REFLOATED AND SAFETY ANCHORED. THIS IS A MINIMUM REQUIREMENT.
Condition: Unknown
Due 25 March 1990
Resolved 25 March 1990
Construction/Loadline
Issued 25 March 1990
Resolved
COMPLETE INTERNAL EXAMINATION OF ALL BALLAST TANKS AND DOUBLE BOTTOMS UPON SAFE ANCHORAGE. ENSURE TANKS ARE TESTED AND CERTIFIED SAFE FOR WORKERS BY AMARINE CHEMIST. TANKS ARE TO BE MADE AVAILABLE FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 25 March 1990
Resolved 25 March 1990
Engineering
Issued 25 March 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF STBD BOILER LOW WATER ALARM AND LOW LOW COUTOUT. ALARM AND CUTOUT SHALL BVE CONSISTANT WITH PORT BOILER AND WITHIN MANUFACTURERS SPECIFICATIONS.
Condition: Unknown
Due 25 March 1990
Resolved 25 March 1990
Engineering
Issued 25 March 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF PORT BOILER LOW LOW CUTOUT. CUTOUT SHALL BE CONSISTANT WITH STARBOARD BOILER AND WITHIN MANUFACTURERS SPECIFICATIONS.
Condition: Unknown
Due 25 March 1990
Resolved 25 March 1990
Deck/Cargo
Issued 25 March 1990
Resolved
REPAIR HYDRALIC OIL LEAKS ON PORT CARGO WINCH PORT SIDE AMIDSHIPS
Condition: Unknown
Due 25 March 1990
Resolved 25 March 1990
Construction/Loadline
Issued 25 March 1990
Resolved
MAINTAIN BALLAST TANK AND FORE/AFT PEAK TANK SOUNDINGS IN LOG AND SOUND TANKS A MINIMUM OF ONCE EVERY 12 HOURS. IF ANY UNEXPECTED RISE OR FALL OF LEVELS IS INDICATED TAKE CORRECTIVE ACTION AND NOTIFY MSO NEW ORLEANS [phone withheld]
Condition: Unknown
Due 25 March 1990
Resolved 25 March 1990
Documentation
Issued 10 February 1989
Resolved
PROVIDE PROOF OF A CURRENT CERTIFICATE OF FINANCIAL RESPONSIBILITY TO MARINE INSPECTION OFFICE HOUSTON, TX.
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Fire Fighting
Issued 12 January 1989
Resolved
REPAIR EXCESSIVE WATER LEAKS TO THE MAIN FIRE PUMP.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Electrical
Issued 12 January 1989
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL ALARM FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Electrical
Issued 12 January 1989
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL ALARM FOR AUXILIARY DIESEL GENERATOR.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Construction/Loadline
Issued 12 January 1989
Resolved
CONDUCT HYDRO TEST OF PORT SETTLING TANK USING WATER FROM AFTER PEAK AND NOTIFY [name withheld] OF TEST BY TELEX OR MESSAGE.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Lifesaving
Issued 12 January 1989
Resolved
ADJUST BOTH PORT AND STARBOARD LIFEBOATS AS NECESSARY SO AS TO ALIGN DAVIT CHOCK TO MEET STRIKING PLATES TO AVOID DAMAGE TO LIFEBOATS.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Lifesaving
Issued 12 January 1989
Resolved
REPAIR THE PORT LIFEBOAT ENGINE PRIOR TO THE CARRIAGE OF OIL PRODUCTS. DEMONSTRATE TO THE SATISFACTION OF THE COGNIZANT OCMI THE PROPER OPERATION OF THE PORT LIFEBOAT AT FIRST U.S. PORT.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Fire Fighting
Issued 12 January 1989
Resolved
MAKE PERMANENT REPAIR TO THE FIRE MAIN STATION #5.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Fire Fighting
Issued 12 January 1989
Resolved
MAKE PERMANENT REPAIR TO THE EMERGENCY FIRE MAIN DISCHARGE PIPE,
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Accommodation/Occupational Safety
Issued 12 January 1989
Resolved
REPAIR AIR COMPRESSOR #3 IN THE ENGINEROOM.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Electrical
Issued 12 January 1989
Resolved
COVER EMERGENCY BUSTIE BREAKER TO MAIN SWITCHBOARD.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Electrical
Issued 12 January 1989
Resolved
REPAIR OR REPLACE MACHINERY SPACE (FAN) SUPPLY SYSTEM CONTROLLER #1 6-P5.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Engineering
Issued 12 January 1989
Resolved
REPAIR OR REPLACE OIL TEMP. TRANSMITTER IN #1 BOILER CONSOLE.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Construction/Loadline
Issued 22 November 1988
Resolved
CROP AND RENEW AS NECESSARY ALL WASTED BULKHEAD STIFFENERS TRANSVERSE FRAME, 3 AND BRACKETS ON FIRST LEVEL OF AFTERPEAK PORTSIDE FORWARD.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Engineering
Issued 9 June 1988
Resolved
MAKE AVAILABLE FOR INTERNAL EXAM OR CONDUCT 1.25 MAWP HYDRO OF DC HEATER.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Engineering
Issued 24 March 1988
Resolved
REPLACE ALL SAFETY VALVE ESCAPE PIPING FOR BOTH PORT AND STARBOARD BOILERS WHERE WASTED AWAY AND HOLED.
Condition: Unknown
Due 24 March 1988
Resolved 24 March 1988
Fire Fighting
Issued 11 January 1988
Resolved
MAKE PERMANENT REPAIRS TO OR REPLACE IN KIND THE NUMBER THREE (3) FOAM DECKMONITOR. I.A.W. 46 CFR 34.20-1 AND 46 CFR 34.20-25.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Engineering
Issued 11 January 1988
Resolved
READJUST PORT BOILER AFT WATER DRUM SAFETY VALVE BLOWDOWN TO RESEAT AT A PRESSURE NO LOWER THAN 96% OF SET PRESSURE AS REQUIRED BY ASME CODE,SECTIONI,PG-72. SET AND RESEAL IN PRESENCE OF A USCG INSPECTOR.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Engineering
Issued 11 January 1988
Resolved
OPEN PORT BOILERS WATER AND FIRE SIDES FOR U.S.C.G. INSPECTION AS REQUIRED BY 46 CFR 61.10-5(B).
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Deck/Cargo
Issued 11 January 1988
Resolved
PROVE OPERATION OF REMOTE SHUTDOWNS AND OVERSPEED TRIPS ON THREE (3) STEAM TURBINE CARGO PUMPS AND ONE (1) STEAM TURBINE BALLAST PUMP AS REQUIRED BY ABS RULES 33.11 AND 33 CFR 155.780(A)(B)(C).
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Engineering
Issued 11 January 1988
Resolved
PROVE OPERATION OF THE RELIEF VALVES AND OPEN THE FOLLOWING PRESSURE VESSELS FOR AN INTERNAL INSPECTION: AIR RECEIVER IN EMERG. GEN. ROOM, AIR RECEIVER IN STACK, AND AIR RECEIVER IN FOREPEAK. THIS TEST AND INSPECTION IS REQUIRED BY 46 CFR 61.10-5(B) AND 46 CFR 61.10-5(I).
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Deck/Cargo
Issued 27 July 1987
Resolved
PRIOR TO LOADING OIL CARGOES, MAKE PERMANENT ALTERATIONS TO DISABLE THE EXISTING CROSS-CONNECT BETWEEN THE 9C CARGO TANK AND THE BALLAST SYSTEM. BOLTED FLANGES ARE NOT ACCEPTABLE.
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Electrical
Issued 27 July 1987
Resolved
MAKE PERMANENT REPAIRS TO THE REMOTE BILGE PUMP SHUTDOWN AT THE MAIN DECK.
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Engineering
Issued 27 July 1987
Resolved
DISCONNECT SUCTION PIPE BETWEEN THE SLUDGE TANK AND THE BILGE PUMP MANIFOLDAND RE-PIPE SLUDGE TANK TO MAIN DECK DISCHARGE WITH APPROPRIATE PUMP. DOUBLE CHECK VALVES MUST BE INSTALLED AT THE BILGE PUMP/DECK DISCHARGE PIPECONNECTION TO PREVENT OIL SLUDGE FROM RETURNING TO THE BILGE SYSTEM.
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Documentation
Issued 27 July 1987
Resolved
PRIOR TO LOADING "OIL" CARGOES, PROVIDE ON BOARD THE UPDATED TRIM & STABILITY BOOK, THE TYPE TEST APPROVAL LETTER FOR CARGO OIL MONITOR, AND ANAMENDED CRUDE OIL WAS & IGS OPERATIONS MANUAL.
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Engineering
Issued 27 July 1987
Resolved
PROVIDE ON BOARD A STANDARD DISCHARGE CONNECTION. (33 CFR 155.430)
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Fire Fighting
Issued 11 July 1986
Resolved
VESSEL TO PROVE OPERATIONAL TEST OF ONBOARD FIRE PUMPS TO CG MARINE INSPECTOR.
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Navigation
Issued 11 July 1986
Resolved
VESSEL TO PROVE OPERATIONAL TEST OF BRIDGE STEERING POWER FAILURE ALARMS TO CG MARINE INSPECTOR.
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Unknown
Issued 14 June 1986
Resolved
THE STEERING SYSTEM SHALL BE INSPECTED/TESTED PRIOR TO DEPARTING THE NEXT U.S. PORT A WATCHSTANDER SHALL BE STATIONED IN THE STEERING GEAR ROOM DURING ALL MANEUVERING SITUTATIONS UNTIL SYSTEM HAS BEEN REINSPECTED BY A SUITABLE TECHNICAL EXPERT.
Condition: Unknown
Due 14 June 1986
Resolved 14 June 1986
Unknown
Issued 13 February 1986
Resolved
RESET STARBOARD SUPERHEATER SAFETY VALVE, PROVE PROPER OPERATION OF THE VALVE AND HAVE WITNESSED BY USCG.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Unknown
Issued 13 February 1986
Resolved
REPAIR ENGINE COVER ON PORT LIFEBOAT.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Unknown
Issued 13 February 1986
Resolved
MAKE REPAIRS TO EMERGENCY FIRE PUMP BREAKER AND PROVE OPERATION OF PUMP AND RELIEF VALVE. THIS SHALL BE COMPLETED PRIOR TO LOADING CARGO AND PRIOR TO DEPARTURE FROM THE NEXT PORT.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Unknown
Issued 13 February 1986
Resolved
RECALIBRATE OR RENEW PRESSURE AND TEMPERATURE GAUGES ON MAIN CONSOLE IN ENGINE ROOM.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Unknown
Issued 13 February 1986
Resolved
INSTALL EMERGENCY ALARM BELL FOR ELEVATOR.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Unknown
Issued 13 February 1986
Resolved
TEST EMERGENCY SHUT DOWN AND OVERSPEED TRIPS TO CARGO PUMPS. THIS SHALL BE COMPLETED PRIOR TO LOADING CARGO.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Unknown
Issued 13 February 1986
Resolved
PROVIDE NEW JACOBS LADDER FOR PORT LIFEBOAT.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Navigation
Issued 16 November 1985
Resolved
VESSEL DID NOT HAVE A TIDAL CURRENT TABLES.
Condition: Unknown
Due 16 November 1985
Resolved 16 November 1985
Construction/Loadline
Issued 15 November 1985
Resolved
MAKE PERMANENT REPAIRS TO TWO FRACTURES/LEAKS IN THE PORT AND STARBOARD WING BUNKER TANKS IN WAY OF FRAME #258 (PUMP ROOM FORWARD BULKHEAD) APPROX.15 FEET BELOW MAIN DECK.
Condition: Unknown
Due 15 November 1985
Resolved 15 November 1985
Deck/Cargo
Issued 1 November 1984
Resolved
PROVE OPERATION OF INERT GAS SYSTEM TO THE SATISFACTION OF THE COGNIZANT COAST GUARD MARINE INSPECTION OFFICE.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984