Documentation record
Registered dimensions (L × B × D)63.0 ft × 20.0 ft × 7.5 ft
Registered tonnagegross 75 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRALPH'S BOAT WORKS · GARDENA, CA, UNITED STATES · built 1973
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 21 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 31 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 31
22 July 2025
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8160624
11 February 2025
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8040167
14 August 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7927288
18 March 2024
Plan Review "T" Boat · Administrative Inspection · Special Consideration
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7885505
2 November 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7789789
5 May 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7681856
10 April 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7655861
9 April 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7649130
28 February 2023
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7643578
7 February 2023
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7609231
6 October 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7535674
6 May 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7457868
12 April 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7429775
16 September 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7313599
29 January 2021
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7133205
19 August 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7037616
5 May 2020
Administrative Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6948624
5 December 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6868883
29 October 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6844485
20 September 2019
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6816951
6 June 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6664506
22 January 2019
Deadweight Survey · Deficiency Check · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6592033
13 June 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6400935
13 December 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6324053
31 July 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6233668
13 July 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6174597
20 March 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6107714
19 March 2017
Damage Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6107711
18 January 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6016268
16 May 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5880749
28 April 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5824749
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2023
Resolved
Reattach grounding wires or prove grounding in engine room bilge at the base of the entry ladder.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2023
Resolved 7 March 2023
Resolution: Grounding wires firmly attached.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2023
Resolved
Prove proper operation of engine room distribution panel door closure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2023
Resolved 7 March 2023
Resolution: Distribution panel door has been secured and penetrations filled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 February 2023
Resolved
The owner or managing operator shall make a vessel available for drydock examinations. The vessel is overdue for the dryrock examination. The vessel shall not operate with passengers until a USCG Marine Inspector completes a drydock examination.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2023
Resolution: The vessel completed a successful drydock.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 October 2022
Resolved
Every vessel subject to Part III of Title III of the
Communications Act must have a detailed inspection of
the radio installation by an FCC-licensed technician in
accordance with § 80.59 once every five years.
Certificate is expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2022
Resolved 21 October 2022
Resolution: Vessels radio eqiupment inspected and new certificate issued by FCC-licensed technician.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 6 October 2022
Resolved
The equipment required for life floats and buoyant
apparatus must meet the following specifications: Each
paddle must be lashed to the life float to which it
belongs and buoyant. Paddles were not lashed to their
respective life floats.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
Resolution: O/O had crew lash paddles to respective life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 September 2021
Resolved
Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. Inspector found that paddles were not lashed to the life float.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 16 September 2021
Resolution: Operator lashed two paddles to each lifefloat.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 11 October 2019
Resolved
All mattresses must comply with either (1) the us department of commerce "standard for mattresses flammability" (FF 4-72.16) 16cfr part 1632 subpart a & not contain polyurethane foam or (2) IMO res. A.688(17) incorporated by reference 46cfr175.600. Mattresses that are tested to this standard nay contain polyurethane foam. Vessel to provide sufficient documentation to the standard onboard mattresses meet or replace/renew with ones that meet the standard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 12 April 2022
Resolution: Vessel removed all mattress from vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 October 2019
Resolved
At each initial & subsequent inspection for certification, reinspection & at every other vessel inspection the MI shall require that all observed unsafe practices & hazardous situations be corrected. Vessel is not authorized overnight accommodations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 October 2019
Resolution: Vessel made proper repairs to emergency lights, sinage and is authorized overnight accomodations.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 13 June 2018
Resolved
Provide a 2" extension beyond the last oriface and close with a cap
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2018
Resolved 21 February 2019
Resolution: Operator contracted approved fire maintenance technician to install the required 2 inch extension and cap.
Navigation › Piloting/Steering › Marine Charts
Issued 13 July 2017
Resolved
Provide updated charts
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 31 July 2017
Resolution: Def Cleared
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 13 July 2017
Resolved
Provide Training log with date of drill & training conducted with general description.
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 31 July 2017
Resolution: Def Cleared
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 13 July 2017
Resolved
Post Hotline number in common space
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 31 July 2017
Resolution: Def Cleared
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 13 July 2017
Resolved
Ensure CO2 instructions are legible
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 31 July 2017
Resolution: Def Cleared
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 March 2017
Resolved
Make permanent repairs to hull to restore watertight integrity and structural strength.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2017
Resolved 22 May 2017
Lifesaving › Lifefloat › Float-free Link
Issued 19 March 2017
Resolved
Arrange survival craft to comply with stowage requirements with regard to weak link, float free ability, and securing paddles.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2017
Resolved 22 May 2017
Engineering › Bilge Water Management System › Pump
Issued 19 March 2017
Resolved
Prove fully rated operation of installed bilge pumping system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2017
Resolved 22 May 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 18 January 2017
Resolved
Make bulkhead between lazarette and engine room is watertight in vicinity of port engine exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 9 February 2017
Resolution: Bulkhead between lazarette and engine room was made watertight to the satisfaction of the attending MI.
Communications › Alarms/Indicators › High Water Alarm
Issued 28 April 2016
Resolved
Provide high level bilge alarm in main cabin.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 7 June 2016
Resolution: Provided new bilge alarm for space
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 28 April 2016
Resolved
Provide updated DAPI crew list.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 7 June 2016
Resolution: Emailed current DAPI list
Documentation › Logs/Records › Logbook (official)
Issued 28 April 2016
Resolved
Provide vessel records of crew training and EPIRB testing.
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 7 June 2016
Resolution: Provided new records