MAURY USCG vessel records Sign in
← All vessels

MISS LESLEA ANN

MISS LESLEA ANN is a 1953 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 1998, most recently in March 2026, along with 26 deficiencies.

Records from 1998 to 2026. Most recent: inspection, 16 March 2026.

Built
1953
Last inspected
16 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

476290
Flag
UNITED STATES
—
Maury page id
psix-476290

Inspections, by type

…with no type recorded1
Years with a record 24 calendar years (1998–2026)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it6 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 35

16 March 2026 COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8326842
26 June 2025 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8163216
10 April 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8109568
3 April 2024 Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7889440
11 January 2024 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7848118
29 August 2023 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7780165
16 June 2023 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7725429
1 June 2022 Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7465618
6 April 2021 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7165710
30 March 2020 Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6933308
7 May 2019 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6678093
5 March 2019 Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6640182
25 February 2019 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6635756
23 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6492399
2 April 2018 Drydock Exam · Annual Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6383784
30 May 2017 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6160553
7 October 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6018366
6 April 2016 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5848269
9 May 2012 Hull Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4331345
21 December 2011 Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4212056
28 May 2008 Deficiency Check · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3204624
6 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2960544
11 January 2007 Examination of Repairs
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2867440
12 June 2006 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2677349
2 August 2005 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2443341
5 August 2004 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2157054
2 June 2004 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2086318
23 July 2003 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1854947
13 August 2002 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1660703
3 June 2002 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1627222
17 May 2001 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1466221
11 May 2000 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1441665
1 July 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1084077
10 May 1999 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1437552
22 May 1998 Hull Examination · Initial Certification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1466521

Deficiency record · 26

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 April 2026 Resolved
An adult life jacket must be provided for each person carried on board a vessel. All life jackets adult and child were severely weathered and tearing when inspected.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2026
Resolution: Received video evidence of replaced life-jackets
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 April 2026 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to provisions for a seaworthy hull. The bearing bolts for the shaft were leaking water when underway.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2026
Resolution: Received video evidence of repaired shaft seal bolts.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 April 2026 Resolved
Each ring life buoy on a vessel must: be approved IAW 46 CFR 160.050and a vessel must carry one floating water light. Life buoy did not have retro reflective tape and the floating water light did not operate properly. Vessel is restricted to daytime operations only.
Action required: 705 - Other - as specified
Resolved 7 April 2026
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 April 2018 Resolved
VSL is at least 5 net tons and does not have a COD.
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 6 April 2018
Resolution: VSL was able to get a certificate of number from the state of Texas.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 2 April 2018 Resolved
No drug testing results or documentation since 2013-2014.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 April 2018
Resolution: VSL rep provided documention of enrollment DOT approved consortium dated 02 APR2018. Also received MIS data collection form. All, sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 April 2018 Resolved
VSL's all around white light is inoperable. Master was working on replacing light during inspection and upon completion of inspection vsl still does not have a working all around white light required by rule 23. Repair prior to operating at at and low visibility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 3 April 2018
Resolution: VSL rep installed new all around white light. All sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 April 2018 Resolved
Battery on float light was dead line holdig float light to lifebuoy was not long enought to tie around the body. Lifebuoy was missing the required 4 evenly spaced pieces of retro tape.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 3 April 2018
Resolution: VSl rep replaced battery and retro tape and line for light.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 April 2018 Resolved
1 Adult and 1 Child PFD was not serviceable, and needed to be replaced. Master corrected on the spot, old PFD's destroyed.
Action required: 705 - Other - as specified
Resolved 2 April 2018
Resolution: Corrected on the spot
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 April 2018 Resolved
vsl first aid kit is expired and no longer serviceable.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 17 April 2018
Resolution: Vsl rep provided documention that new first aid kits have been purchased.
Construction/Loadline › Hull › Longitudinal Frame
Issued 2 April 2018 Resolved
Aft compartment inboard support beam detached at bottom weld and metal is wasted. Crop and repalce wasted frame.
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 10 April 2018
Resolution: Wasted metal has been repaired, all sat.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 30 May 2017 Resolved
Vessel's passenger count increased to 28. Limited to number of passengers provided for by number of lifesaving equipment.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 30 May 2017
Resolution: New lifejackets acquired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 May 2017 Resolved
Vessels navigation lights not operable. Restricted to operating between 15 minutes after sunrise to 15 minutes before sunset.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 31 May 2017
Resolution: Nav lights replaced and tested.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 6 April 2016 Resolved
Examined fixed CO2 system which had two 20 lbs CO2 bottles installed.. Per MSC approval letter dated, 6/15/2005, the system lsit two 35 lbs bottles of CO2 installed. Proved evidence showing vessel has sufficient amount of CO2 per 46 CFR 181.20-10.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 23 May 2016
Resolution: O/O submitted, to MSC, calculations for the cubic footage of the below deck spaces being protected and total amount of CO2 onboard to which MSC replied via email stating there was a sufficient amount of CO2 onboard per the calculations. Def cleared.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 30 May 2008 Resolved
PROVIDE MEANS OF MANUAL MECHANICAL VENTILATION SHUT-DOWN IWO CO2 PROTECTION SPACE TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR PRIOR TO OPERATION
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2008
Resolution: POC SUPPLIED PICTURES AND NARRATIVE INDICATING THAT PERMANENT VENT SHUT-DOWNS HAVE BEEN INSTALLED. DEF CLEARED.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 June 2006 Resolved
Vessel did not have a valid COI. Vessel must obtain a valid COI prior to operation.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2006
Resolved 12 June 2006
Resolution: Conducted a satisfactory COI examination and issued a valid COI.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 June 2006 Resolved
Vessel missed hull exam dated 03JUN06. Vessel must complete a valid hull examination prior to operation.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2006
Resolved 12 June 2006
Resolution: Vessel completed a satisfactory hull examination.
Lifesaving › Lifebuoys › Serviceable
Issued 2 August 2005 Resolved
Replace current life buoy with satisfactory replacement due to wastage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2005
Resolved 16 August 2005
Resolution: Life buoy was replaced with new.
Construction/Loadline › Hull › Bracket
Issued 2 August 2005 Resolved
Renew or replace forward hinge pin assembly due to wastage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2005
Resolved 16 August 2005
Resolution: Repaired hinge pin assembly.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 August 2005 Resolved
Renew or replace current first aid kit with an approved USCG type with vaild non expired contents.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2005
Resolved 16 August 2005
Resolution: Vessel replaced first aid kit with an approved type.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 2 June 2004 Resolved
Install and demonstrate proper operation of a vapor detection system in engine compartment and gasoline fuel tank compartment. 46 CFR 182.410(c) 46 CFR 182.480 LEGACY COMPONENT DESC: Vapor detection system
Due 2 July 2004
Resolved 10 August 2004
Resolution: Vapor detection system in engine and gasoline fuel tank compartments is installed and is IAW 46 CFR 182.480.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 June 2004 Resolved
Install and demonstrate proper operation of auto bilge pump indicator lights. 46 CFR 182.539(c) LEGACY COMPONENT DESC: Auto bilge pump run alarm
Due 2 July 2004
Resolved 10 August 2004
Resolution: Observed proper operation of auto bilge pump indicator lights.
Personnel › Training
Issued 23 July 2003 Resolved
Provide copy of Red Cross first aid/CPR cards for master. LEGACY COMPONENT DESC: First Aid/CPR
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2003
Resolved 6 August 2003
Resolution: Master attended course and provided proof of completion.
Operations/Management › Drug and Alcohol Testing
Issued 23 July 2003 Resolved
Provide proof of participation in an approved drug testing program. LEGACY COMPONENT DESC: Employee Coverage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2003
Resolved 5 November 2003
Resolution: Company employees enrolled in drug consortium.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 23 July 2003 Resolved
Provide one B-II fire extiguisher onboard as required by COI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2003
Resolved 6 August 2003
Resolution: B-II fire extinguisher placed onboard.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 July 2003 Resolved
Renew lifeline on ringbuoy with black or other UV resistant bouyant line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2003
Resolved 6 August 2003
Resolution: Line renewed with polypropylene line.
Construction/Loadline › Structures
Issued 23 July 2003 Resolved
Renew font drive shaft hinge assembly and mounting brackets. LEGACY COMPONENT DESC: Hinge assembly
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 August 2003
Resolved 6 August 2003
Resolution: Hinge assembly and mounting brackets renewed and inspected.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.