Records from 1998 to 2025. Most recent: inspection, 26 June 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
26 June 2025
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8160544
17 April 2025
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8114005
15 May 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7917406
10 January 2024
Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7848789
29 March 2023
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7660407
24 March 2022
Internal Structural Exam · COI Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7424424
5 March 2021
Drydock Exam · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7150985
15 July 2020
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7002856
28 March 2019
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6660471
24 October 2018
Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6580060
25 July 2018
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6507187
9 May 2018
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6420384
15 March 2017
COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6106208
9 April 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5851816
18 March 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4817810
17 February 2012
Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4246591
14 December 2009
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3650074
9 April 2009
Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3451600
3 March 2009
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3430524
18 April 2008
Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3187005
3 April 2008
Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3177691
23 April 2007
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2915570
13 October 2006
Simplified Stability Test
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2849746
1 March 2006
COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2594097
1 March 2005
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2301352
23 March 2004
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2034184
7 May 2003
Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 1788592
17 March 2003
Periodic Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 1736898
3 April 2002
Deficiency Check · Administrative Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1600947
20 February 2002
Deficiency Check · Periodic Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1492435
1 August 2001
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1071011
12 June 2001
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1067945
5 June 2001
Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1066798
11 May 2001
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1064385
24 April 2001
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1063314
27 March 2001
Hull Examination · COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1458857
11 May 2000
Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1441664
1 July 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1088272
17 May 1999
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1437554
22 May 1998
Initial Certification · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1466522
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 May 2024
Resolved
Pre-Engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. FF suppression system bottle in the aft void (port side)next to the gasoline fuel tank was found without a charge. Vessel owner shall replace extinguishing bottle prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2024
Resolution: Owner replaced extinguishing bottle with a charged bottle. Visual inspection all Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2024
Resolved
Fuel supply hose found with outer jacket chaffed near the carburetor. Fuel lines must installed and secured against excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protected against corrosion. Owner shall replace the fuel line and metal straps with new in accordance with the regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 16 May 2024
Resolution: Owner replaced fuel hose with new approved material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2024
Resolved
Engine exhaust pipe installation must be suitably insulated or shielded from combustible material. Vessels dry engine exhaust pipping from a gasoline powered engine found without out proper insulation. Owner shall properly insulate the engine exhaust system within 30 days of the inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2024
Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2 1/2 gallon) buckets. The words FIRE BUCKET must be stenciled in a contrasting color on each bucket. Vessel was found with three 4 1/2 gallon buckets. Owner shall replace with the 2 1/2 gallon buckets and stencil FIRE BUCKET on each.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photo of the fire buckets meeting the requirement of the regulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 May 2024
Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by electrolyte. Vessel battery found on the the deck near drivers seat without a tray/battery box. Owner shall place batteries in a appropriate tray/ box meeting the requirements with in 14 days of the inspection date.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photo of the batteries in a approved box.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2024
Resolved
The Vessel is required to process sistering information to Marine Safety Center(MSC) and get a stability letter prior to operating with full COI passenger count. The vessel is restricted to the carriage of 26 passengers and 1 crew member until the stability test process is completed and approved. Complete prior to August 30th 2024.
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 10 October 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2024
Resolved
Vessel is under going the modifications required by 46CFR175.124. Vessel will not be able to carry passengers in accordance with the COI until the requirements of the regulations are met.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2024
Resolution: Owner [name withheld] modifications and waiting on MSC stabilty letter
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 March 2023
Resolved
Fire Extinguishing Systems on board the vessel inspection dates were over due. Owner shall ensure the Fire fighting equipment is maintained and maintenance schedules are with in a annual period.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 10 May 2023
Resolution: Owner had fire extingushing equipment inspected by outside source. All Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 March 2023
Resolved
Shaft seal was observed with an excessive leak while under way. Owner shall repair or replace shaft seal to the manufactures specifications.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 26 April 2023
Resolution: Shaft seal was repaired and operating in accordance with manufactures recommendations.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 March 2023
Resolved
Vessel Stern light was broken and was not able to be operated. Vessel owner shall replace/repair light.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 26 April 2023
Resolution: Vessel replaced stern light and light is operational
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 March 2023
Resolved
Vessel missing one adult life Jacket. Vessel owner shall ensure that the vessel has the correct amount of life jackets on board according to the COI.
Due 31MAR2023
Action required: 705 - Other - as specified
Due 31 March 2023
Resolved 26 April 2023
Resolution: Vessel owner replaced PFD. Vessel has required amount of PFD's on board.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2023
Resolved
Drug and Alcohol program (DAPI) was unavailable during inspection. Owner shall submit DAPI program to MSD Fort Smith inspector within 7 Days.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 10 May 2023
Resolution: Owner was able to send a copy of the DAPI program through email. All Sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022
Resolved
Vessel does not have shut off valves at the hull penetrations on the port side for the radiator hoses. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022
Resolved
Vessel does not have shut off valves at the hull penetrations on the front of the engine compartment for the hoses going to the deferential of the axle. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 March 2022
Resolved
Properly mark and stow PFD's in the correct vessel. Adult PFD's and Child PFD's shall be stowed and marked in the proper locations.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner properly stowed and Marked PFD's on board the Vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2022
Resolved
Vessel operator is unable to show the fuel is shut off after operating the emergency fuel shut off. Owner shall provide an indicator for the fuel shut off.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed a Fuel Shut off that indicates when the fuel is on or off.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021
Resolved
The COI shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request.
The vessel does not maintain a valid COI on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed COI
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 March 2021
Resolved
The stability letter shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request.
The vessel does not maintain a valid stability letter on
board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed Stability Letter
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021
Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Child size life jackets are not stowed separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Separated Child Sized life jackets
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 March 2021
Resolved
Isolated pitting found on interior hull plating , stbd side just forward of front passenger row, approximately 2 feet outboard of centerline. Pitting is found to be 1/16" deep.
Provide drawings showing thickness of hull.
Clad weld areas of isolated pitting and conduct float test after repairs are completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Made perm repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2021
Resolved
In systems where flexible hoses are permitted; double hose clamping is required.
Fuel line missing hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Installed hose clamps
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2021
Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration; Where passing through bulkheads must be protected.
There is no chaffing gear on the fuel line as it penetrates the bulkheads.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Installed chaffing gear
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 March 2021
Resolved
Inspection and operation of all weathertight closures above the weather deck and the provisions for drainage
of sea water from the exposed decks;
Forward hatch opening gasket missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Installed new gasket.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 March 2021
Resolved
The owner/operator must provide evidence of required servicing of fixed gas fire extinguishing systems.
The fixed gas fire extinguishing system servicing had expired.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2021
Resolution: Serviced fixed system
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 March 2021
Resolved
All electrical equipment and circuits must be clearly marked and identified.
The Navigation lights at the operating station are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Labeled NAV lights at operating station
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 July 2020
Resolved
Replace seals around engine compartment hatch, front ventilation hatch and rear door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 15 July 2020
Resolved
Clean bilge of all debris and oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
Construction/Loadline › Hull › Side Shell
Issued 9 May 2018
Resolved
Found a fracture on the shell plating near the port side wheel well. Crop/renew area.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 May 2018
Resolved 9 May 2018
Resolution: Area was cropped/renewed with an insert plate.
Engineering › Fuel Oil Service System › Filter
Issued 15 March 2017
Resolved
The fuel filter found in the engine space was plastic. Replace with a suitable metal marine type strainer meeting the requirements of the engine manufacturer.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 15 March 2017
Resolution: Fuel filter was replaced on the spot; requested that the owner verify the other vessels in the fleet do not have plastic fuel filters.
Engineering › Gasoline Engine (propulsion) › Alternator (4 cycle)
Issued 18 March 2014
Resolved
Vessel's gasoline engine has a newly installed alternator. Any new installation must be ignition protected or intrinsically safe as per 46 CFR 183.530.
Due 18 April 2014
Resolved 10 April 2014
Resolution: New approved alternator was installed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 March 2014
Resolved
The vessel did not have a portable light at the operating station. The vessel must be equipped with a suitable number of portable battery lights as per OLD 46 CFR 184.30.
Due 18 April 2014
Resolved 10 April 2014
Resolution: Vessel had two new flashlights at operating station.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 18 March 2014
Resolved
Vessel did not have a B-II fire extinguisher. Vessel must place a B-II fire extinguisher on board as per 46 CFR 181.500(a).
Due 18 April 2014
Resolved 10 April 2014
Resolution: Vessel provided B-II fire extinguisher.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 18 March 2014
Resolved
The dampers used for manual ventilation shut off to engine room in case of a fire did not close. Prove proper operation. 46 CFR 182.465.
Due 18 April 2014
Resolved 10 April 2014
Resolution: Proved proper operation of dampers.
Documentation › Certificates/Documents › Stability Letter
Issued 17 February 2012
Resolved
Identified discrepancy between stability letter and COI regarding person allowed on-board. Stability letter denotes 30 passengers allowed, where as COI denotes 31 persons allowed. Until the issue is resolved or a new COI issued, a CG-835 will be issued limiting the number of passengers to 29, making total number of persons allowed 30.
Action required: 705 - Other - as specified
Due 17 April 2012
Resolved 17 October 2016
Resolution: Amended COI.
Fire Fighting › Fire Bucket › Stenciling
Issued 3 March 2009
Resolved
Fire buckets not stenciled
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2009
Resolved
Port side vent closure not working
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2009
Engineering › Bilge Water Management System › Piping
Issued 3 March 2009
Resolved
Higgins pump not double clamped
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2009
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 March 2009
Resolved
Not properly marked
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2009
Construction/Loadline › Markings › Load Line Mark
Issued 3 March 2009
Resolved
Freeboard load line not marked on the hull of the vessel
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 March 2009
Resolved
Children lifejacket stowed location not appropriately marked as 46 CFR 180.78 (a) (5)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2009
Resolved
Throughout the vessel, plastic straps were used to attach wires to the vessel's hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2009
Resolved 9 April 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2009
Resolved
Segregate fuel tank compartment to ensure efficiency of fixed fire protection system
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 11 March 2009
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 3 March 2009
Resolved
Shaft packing leaking excessively.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Resolution: Water tested- All Sat.
Construction/Loadline › Hull › Weld
Issued 3 April 2008
Resolved
Starboard stern-rib caulk deteriorated, recommend reweld.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 May 2008
Resolved 18 April 2008
Resolution: Welded stern rib.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 3 April 2008
Resolved
Front shaft bracket support is broken.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 May 2008
Resolved 18 April 2008
Resolution: Repaired shaft bracket.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 3 April 2008
Resolved
Rear shaft support pin is missing
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 May 2008
Resolved 18 April 2008
Resolution: Replaced rear shaft support pin.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 April 2007
Resolved
Repair or replace bilge high water indicating light.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 1 June 2007
Resolution: Light replaced
Stability › Watertight Integrity › Coaming
Issued 13 October 2006
Resolved
Vessel is required to extend the watertight coaming around the aft deck area. The coaming is to be watertight to a height of 12" above the after deck.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 30 May 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 March 2006
Resolved
Repair FWD port high level bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2006
Engineering › Bilge Water Management System › Pump
Issued 8 March 2006
Resolved
Repair FWD port bilge pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2006
Construction/Loadline › Hull › Bottom Plating
Issued 8 March 2006
Resolved
Crop & renew to original by way of insert (radius corners) holed bottom plating fwd stbd side wheel well - aft of tire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 March 2005
Resolved
Install lock washers and renew cotter pins on retaining brackets.
IAW NVIC 01-01. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 March 2005
Resolved
Install restrictor plate. IAW NVIC 01-01. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 8 March 2005
Resolved
Properly strap down battery on vsl. Check ALL vsl's for this condition.
IAW 46 CFR 183.350(b). Prior 08 Apr 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 5 May 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 March 2005
Resolved
Provied proof of annual service on all vsl portable fire extinguishers IAW 46 CFR 176.810(b)(1). Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 March 2005
Resolved
Provide proof of annual service on vsl's fixed fire extinguisher IAW 46 CFR 176.810(b)(1). Prior to 01 Apr 2005.
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 5 May 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 March 2005
Resolved
Make repairs and/or alterations to firewall so that it is
MORE vapor tight. IAW NVIC 01-01 encloser 1 page 27. Prior to 08 APR 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 5 May 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 March 2005
Resolved
Post lifejacket donning placard. IAW 46 CFR 185.516. Prior to 08 Apr 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 5 May 2005
Documentation › Markings/Placards › Garbage Placard
Issued 8 March 2005
Resolved
Post MARPOL Placard. IAW 33 CFR 151.59 (a)(I). Prior to 08 Apr 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 5 May 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 8 March 2005
Resolved
Post oil pollution placard at each bilge control station. IAW 33 CFR 155.450. Prior to 08 Apr 2004.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 5 May 2005
Communications › Audible Communications › Horn/Whistle
Issued 8 March 2005
Resolved
Provide a horn or sound signaling device. IAW 33 CFR 86. Prior to 08 Apr 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Documentation › Manuals/Policy Documentation
Issued 23 March 2004
Resolved
Provide Operations Manual for review. LEGACY COMPONENT DESC: Operations Manual
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 24 March 2004
Resolution: Operations Manual provided for review.
Documentation › Manuals/Policy Documentation
Issued 23 March 2004
Resolved
Provide Emergency Response Manual for review. LEGACY COMPONENT DESC: Emergency Response Manual
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 24 March 2004
Resolution: Emergency Response Manualprivied for review.
Documentation › Logs/Records
Issued 23 March 2004
Resolved
Provide vessel's name on passenger count log. LEGACY COMPONENT DESC: Logbook (official)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2004
Resolution: Vessel''s name provided on passenger count log.
Construction/Loadline › Structures
Issued 23 March 2004
Resolved
Repair vapor barrier in the engine space. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2004
Resolution: Vapor barrier in the engine space repaired.
Construction/Loadline › Structures
Issued 23 March 2004
Resolved
Make fuel tank space vapor tight.
Condition: Improper/Lack of Maintenance
Due 23 April 2004
Resolved 29 April 2004
Resolution: Fuel tank space made vapor tight.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 23 March 2004
Resolved
Provide evidence of 50% First Aid and CPR card. LEGACY COMPONENT DESC: First Aid
Due 1 June 2004
Resolved 1 June 2004
Personnel › Certificates/Documents/Licenses
Issued 23 March 2004
Resolved
Provide masters' licenses for review. LEGACY COMPONENT DESC: License, Master
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 24 March 2004
Resolution: Masters'''''''' licenses provided for review.
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 March 2004
Resolved
Provide onboard a USCG approved first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 23 April 2004
Resolved 29 April 2004
Resolution: Approved first aid kit provided on board.
Construction/Loadline › Structures
Issued 23 March 2004
Resolved
Remove unused rear axle hent vent hoses and cap off.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Unused rear axle hent vent hoses removed and capped off.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 23 March 2004
Resolved
Repair horn.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2004
Engineering › Bilge Water Management System
Issued 23 March 2004
Resolved
Prove operation of FWD STBD high-water alarm. LEGACY COMPONENT DESC: Water Level Alarm
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2004
Resolution: Operation of FWD STBD high-water alarm proven.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 March 2003
Resolved
Maintain fixed fire extinguishers semi-annualy IAW manufacturers instructions.
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: All extinguishers inspected and tagged.
Construction/Loadline › Hull
Issued 17 March 2003
Resolved
Crop and renew wasted hull plating in way of port aft sump. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 19 April 2003
Resolved 19 March 2003
Resolution: Wasted hull plated cropped and replaced with like material.
Lifesaving › Lifejacket/PFD (Type I)
Issued 17 March 2003
Resolved
Label PFD's with vessel name. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: All PFDs have correct vessel name.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 20 March 2002
Resolved
Remove safety for the fore and aft fixed fire extinguishing system cylinder heads. LEGACY COMPONENT DESC: Operating Controls
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2002
Resolution: Both pins have been removed.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 20 March 2002
Resolved
Install a sheet metal fire wall between the engine compartment and the passenger seating area to insure that the enigne compartment space does ot exceed 125 cubic feet. LEGACY COMPONENT DESC: Quantity of Gas
Due 20 March 2002
Resolved 20 March 2002
Resolution: A vapor barrier has been installed.
Construction/Loadline › Markings
Issued 20 March 2002
Resolved
Provide a permanent and painted mark indicating the 15.5 inch freeboard at the vessel's stern. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 20 March 2002
Resolved 20 March 2002
Resolution: A permanent and painted mark has been provided.
Engineering › Shafting/Propeller Arrangements
Issued 20 March 2002
Resolved
Provide and install a total of 4 cotter pins in way of the hinge pin on the shaft housing hinge assembly as per page 329 of the GM technical manual. LEGACY COMPONENT DESC: Coupling
Condition: Improper Installation
Due 20 March 2002
Resolved 20 March 2002
Resolution: All 4 required cotter pins have been provided and installed.
Engineering › Fuel Oil Service System
Issued 20 March 2002
Resolved
Replace flexible fuel hoses with SAE J 1492 standard hose. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 10 April 2002
Resolved 10 April 2002
Resolution: MSO Memphis received a fax letter dated 4/15/2002 from the owner/operator stating that the fuel line was changed on 4/10/2002.
Electrical › Electric Supply System (service)
Issued 20 March 2002
Resolved
Proivde and install a battery box that is corrosion-resistant. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper Installation
Due 20 March 2002
Resolved 20 March 2002
Resolution: A battery box has been installed.
Operations/Management › Drills/Instruction
Issued 20 March 2002
Resolved
Provide and post Emergency Instructions in accordance with 46 CFR 185.510. LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Due 20 March 2002
Resolved 20 March 2002
Resolution: The posted instructions were reviewed.
Documentation
Issued 24 April 2001
Resolved
Provide for USCG review, a company operations manual as per NVIC 1-01.
Condition: Unknown
Due 31 August 2001
Resolved 20 February 2002
Resolution: Manual provided for review.
Engineering
Issued 27 March 2001
Resolved
Provide and install cotter pin in way of propeller nut prior to carrying passengers.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Navigation
Issued 27 March 2001
Resolved
Make watertight the area in way of the starboard running light.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 27 March 2001
Resolved
Make watertight the area in way of lap seam between the center piece on thebow and the starboard fender.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 27 March 2001
Resolved
Provide valves/piping for keel cooler.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Fire Fighting
Issued 27 March 2001
Resolved
Submit written proposal for installation of pre-engineered fire fighting system.
Condition: Unknown
Due 31 December 2001
Resolved 20 February 2002
Resolution: Sea-Fire FE-241 Model FE 125 A was installed.
Construction/Loadline
Issued 27 March 2001
Resolved
Prior to carrying passengers, ensure hinge plate assembly has a minimum of 2 cap screws and properly install all 3 cap screws.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Accommodation/Occupational Safety
Issued 27 March 2001
Resolved
Replace wire rope in way of stern boarding ladder winch.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 27 March 2001
Resolved
Make watwertight the holes where the port and starboard headlights' electrical wire make it's penetration.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 27 March 2001
Resolved
Provide a permanent (welded bead or punched mark) and painted mark indicating minimum freeboard at vessel's stern.
Condition: Unknown
Due 31 December 2001
Resolved 20 February 2002
Resolution: Not resolved. Re-issued in MISLE Activity 1492435.
Fire Fighting
Issued 27 March 2001
Resolved
Install a mechanism that will permit the operator to secure the engine compartment hatch cover.
Condition: Unknown
Due 31 December 2001
Resolved 20 February 2002
Resolution: Mechanism installed and tested satisfactory.
Fire Fighting
Issued 27 March 2001
Resolved
Provide and post operating instructions for the installed fire extinguishing system.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 27 March 2001
Resolved
Provide and install vapor detectors in the forward and aft compartments PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Lifesaving
Issued 27 March 2001
Resolved
IN ACCORDANCE WITH 46 CFR 185.516(A) POST THE LIFEJACKET DONNING INSTRUCTIONS IN A CONSPICUOUS LOCATION.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 27 March 2001
Resolved
Provide aft compt fuel shutoff valve.
Condition: Unknown
Due 31 August 2001
Resolved 20 February 2002
Resolution: Valve installed.