Records from 2016 to 2025. Most recent: inspection, 26 June 2025.
Inspection history · 14
26 June 2025
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8160544
17 April 2025
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8114005
15 May 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7917406
10 January 2024
Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7848789
29 March 2023
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7660407
24 March 2022
Internal Structural Exam · COI Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7424424
5 March 2021
Drydock Exam · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7150985
15 July 2020
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7002856
28 March 2019
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6660471
24 October 2018
Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6580060
25 July 2018
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6507187
9 May 2018
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6420384
15 March 2017
COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6106208
9 April 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5851816
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 May 2024
Resolved
Pre-Engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. FF suppression system bottle in the aft void (port side)next to the gasoline fuel tank was found without a charge. Vessel owner shall replace extinguishing bottle prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2024
Resolution: Owner replaced extinguishing bottle with a charged bottle. Visual inspection all Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2024
Resolved
Fuel supply hose found with outer jacket chaffed near the carburetor. Fuel lines must installed and secured against excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protected against corrosion. Owner shall replace the fuel line and metal straps with new in accordance with the regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 16 May 2024
Resolution: Owner replaced fuel hose with new approved material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2024
Resolved
Engine exhaust pipe installation must be suitably insulated or shielded from combustible material. Vessels dry engine exhaust pipping from a gasoline powered engine found without out proper insulation. Owner shall properly insulate the engine exhaust system within 30 days of the inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2024
Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2 1/2 gallon) buckets. The words FIRE BUCKET must be stenciled in a contrasting color on each bucket. Vessel was found with three 4 1/2 gallon buckets. Owner shall replace with the 2 1/2 gallon buckets and stencil FIRE BUCKET on each.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photo of the fire buckets meeting the requirement of the regulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 May 2024
Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by electrolyte. Vessel battery found on the the deck near drivers seat without a tray/battery box. Owner shall place batteries in a appropriate tray/ box meeting the requirements with in 14 days of the inspection date.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photo of the batteries in a approved box.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2024
Resolved
The Vessel is required to process sistering information to Marine Safety Center(MSC) and get a stability letter prior to operating with full COI passenger count. The vessel is restricted to the carriage of 26 passengers and 1 crew member until the stability test process is completed and approved. Complete prior to August 30th 2024.
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 10 October 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2024
Resolved
Vessel is under going the modifications required by 46CFR175.124. Vessel will not be able to carry passengers in accordance with the COI until the requirements of the regulations are met.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2024
Resolution: Owner [name withheld] modifications and waiting on MSC stabilty letter
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 March 2023
Resolved
Fire Extinguishing Systems on board the vessel inspection dates were over due. Owner shall ensure the Fire fighting equipment is maintained and maintenance schedules are with in a annual period.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 10 May 2023
Resolution: Owner had fire extingushing equipment inspected by outside source. All Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 March 2023
Resolved
Shaft seal was observed with an excessive leak while under way. Owner shall repair or replace shaft seal to the manufactures specifications.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 26 April 2023
Resolution: Shaft seal was repaired and operating in accordance with manufactures recommendations.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 March 2023
Resolved
Vessel Stern light was broken and was not able to be operated. Vessel owner shall replace/repair light.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 26 April 2023
Resolution: Vessel replaced stern light and light is operational
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 March 2023
Resolved
Vessel missing one adult life Jacket. Vessel owner shall ensure that the vessel has the correct amount of life jackets on board according to the COI.
Due 31MAR2023
Action required: 705 - Other - as specified
Due 31 March 2023
Resolved 26 April 2023
Resolution: Vessel owner replaced PFD. Vessel has required amount of PFD's on board.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2023
Resolved
Drug and Alcohol program (DAPI) was unavailable during inspection. Owner shall submit DAPI program to MSD Fort Smith inspector within 7 Days.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 10 May 2023
Resolution: Owner was able to send a copy of the DAPI program through email. All Sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022
Resolved
Vessel does not have shut off valves at the hull penetrations on the port side for the radiator hoses. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022
Resolved
Vessel does not have shut off valves at the hull penetrations on the front of the engine compartment for the hoses going to the deferential of the axle. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 March 2022
Resolved
Properly mark and stow PFD's in the correct vessel. Adult PFD's and Child PFD's shall be stowed and marked in the proper locations.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner properly stowed and Marked PFD's on board the Vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2022
Resolved
Vessel operator is unable to show the fuel is shut off after operating the emergency fuel shut off. Owner shall provide an indicator for the fuel shut off.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed a Fuel Shut off that indicates when the fuel is on or off.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021
Resolved
The COI shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request.
The vessel does not maintain a valid COI on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed COI
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 March 2021
Resolved
The stability letter shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request.
The vessel does not maintain a valid stability letter on
board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed Stability Letter
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021
Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Child size life jackets are not stowed separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Separated Child Sized life jackets
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 March 2021
Resolved
Isolated pitting found on interior hull plating , stbd side just forward of front passenger row, approximately 2 feet outboard of centerline. Pitting is found to be 1/16" deep.
Provide drawings showing thickness of hull.
Clad weld areas of isolated pitting and conduct float test after repairs are completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Made perm repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2021
Resolved
In systems where flexible hoses are permitted; double hose clamping is required.
Fuel line missing hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Installed hose clamps
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2021
Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration; Where passing through bulkheads must be protected.
There is no chaffing gear on the fuel line as it penetrates the bulkheads.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Installed chaffing gear
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 March 2021
Resolved
Inspection and operation of all weathertight closures above the weather deck and the provisions for drainage
of sea water from the exposed decks;
Forward hatch opening gasket missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Installed new gasket.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 March 2021
Resolved
The owner/operator must provide evidence of required servicing of fixed gas fire extinguishing systems.
The fixed gas fire extinguishing system servicing had expired.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2021
Resolution: Serviced fixed system
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 March 2021
Resolved
All electrical equipment and circuits must be clearly marked and identified.
The Navigation lights at the operating station are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Labeled NAV lights at operating station
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 July 2020
Resolved
Replace seals around engine compartment hatch, front ventilation hatch and rear door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 15 July 2020
Resolved
Clean bilge of all debris and oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
Construction/Loadline › Hull › Side Shell
Issued 9 May 2018
Resolved
Found a fracture on the shell plating near the port side wheel well. Crop/renew area.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 May 2018
Resolved 9 May 2018
Resolution: Area was cropped/renewed with an insert plate.
Engineering › Fuel Oil Service System › Filter
Issued 15 March 2017
Resolved
The fuel filter found in the engine space was plastic. Replace with a suitable metal marine type strainer meeting the requirements of the engine manufacturer.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 15 March 2017
Resolution: Fuel filter was replaced on the spot; requested that the owner verify the other vessels in the fleet do not have plastic fuel filters.