Records from 1983 to 1999. Most recent: inspection, 20 May 1999.
Inspection history · 30
20 May 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 58686
18 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377678
28 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1176390
13 July 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1176445
21 January 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451916
8 April 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414133
2 October 1992
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245950
16 September 1992
Initial Construction-Excluding Oversight
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 934175
11 September 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 107827
19 March 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316571
28 February 1992
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 952311
26 January 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 152718
9 May 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1240340
18 April 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 915653
15 April 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1218646
7 March 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1226275
17 February 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233685
30 November 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906641
13 February 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1343658
4 May 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1346293
4 April 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993991
29 March 1988
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297837
24 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025628
18 February 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1330020
10 February 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010822
29 October 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014960
28 October 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016208
3 March 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309231
23 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283537
18 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278862
Electrical
Issued 21 January 1994
Resolved
RENEW ALL FRAYED HOSE LENGTHS ON EMERGENCYGENERATOR HYDRAULIC ACCUMULATOR.
Condition: Unknown
Due 21 February 1994
Resolved 28 January 1994
Engineering
Issued 21 January 1994
Resolved
INSTALL METAL GUARD AROUND FUEL LEVEL SIGHTGLASS ON DIESEL FUEL TANK IN GENERATOR SPACE.
Condition: Unknown
Due 21 February 1994
Resolved 28 January 1994
Electrical
Issued 21 January 1994
Resolved
MAKE SATISFACTORY REPAIRS TO EMERGENCY GENERATOR SHUTDOWN LINKAGE SUCH THATGENERATOR ENGINE COMPLETELY SHUTS DOWN.
Condition: Unknown
Due 21 February 1994
Resolved 28 January 1994
Deck/Cargo
Issued 28 February 1992
Resolved
MAKE REPAIRS TO ALL (FOUR) CARGO HATCHES. PROVE WATERTIGHTNESS OF HATCHES IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR. VESSEL IS PROHIBITED FROM LOADING OR CARRYING CARGO UNTIL ITEM IS CLEARED.
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Documentation
Issued 28 February 1992
Resolved
PROVIDE VALID LOADLINE CERTIFICATE ON BOARD VESSEL.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992
Deck/Cargo
Issued 7 March 1991
Resolved
MAKE REPAIR TO PORT MOORING WINCH CONTROL MOUNT.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Deck/Cargo
Issued 7 March 1991
Resolved
INSTALL WINCH MOTOR AND CONDUCT OPERATIONAL TEST TO THE SATIFACTION OF COGNIZANT O.C.M.I.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Construction/Loadline
Issued 17 February 1990
Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED AREA OF THE PORT SIDE STERN (NEAR DECK LEVEL) TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 February 1990
Resolved 17 February 1990
Deck/Cargo
Issued 17 February 1990
Resolved
MAKE PERMANENT REPAIRS TO THE FORWARD ANCHOR WINDLASS AND CONDUCT OPERATIONAL TEST TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 February 1990
Resolved 17 February 1990
Electrical
Issued 17 February 1990
Resolved
REMOVE ALL WIRING AND CONDUIT PIPING ASSOCIATED WITH THE PREVIOUS NAV LIGHTSYSTEM THAT IS NO LONGER SERVICABLE AND NO LONGER IN USE.
Condition: Unknown
Due 17 February 1990
Resolved 17 February 1990
Electrical
Issued 17 February 1990
Resolved
REPLACE COVER TO ELECTRICAL JUNCTION BOX LOCATED ON BARGE'S GENERATOR.
Condition: Unknown
Due 17 February 1990
Resolved 17 February 1990
Deck/Cargo
Issued 17 February 1990
Resolved
REPLACE OR REPAIR HYDRAULIC HOSES AND FITTINGS LOCATED ON BOTH PORT AND AFTMOORING WINCHES TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 February 1990
Resolved 17 February 1990
Construction/Loadline
Issued 24 February 1988
Resolved
PROVE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR THAT THE 42"X84" INSERT ON THE STBD BOW SIDESHELL IS WATERTIGHT. 46 CFR 91.30-1.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Construction/Loadline
Issued 24 February 1988
Resolved
PROVE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR THAT THE INSERTIN THE FWD CARGO TANK BULKHEAD IS WATERTIGHT. 46 CFR 91.25-10.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Electrical
Issued 10 February 1987
Resolved
LABEL THE REMOTE STOP CABLE FOR THE BARGE GENERATOR.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Electrical
Issued 10 February 1987
Resolved
PROVIDE METAAL GUARDS AND GLOBES AS REQUIRED ON EXPLOSION PROOF LIGHT FIXTURES IN THE GENERATOR ROOM AND HYDRAULIC ROOM.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Electrical
Issued 10 February 1987
Resolved
SUBMIT TO [name withheld], LA, PROOF THAT THE NAVIGATION LIGHT FIXTURES ARE APPROVED FOR USE IN HAZARDOUS LOCATIONS (EXPLOSION PROOF) OR REPLACE WITH FIXTURES WHICH ARE EXPLOSION FROOF.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Electrical
Issued 10 February 1987
Resolved
MAKE ALL WIRING, FIXTURES AND ELECRTICAL EQUIPMENT ON THE BARGE EXPLOSION- PROOF.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987