MAURY USCG vessel records
← All vessels

COV HERCULES

Built
1945
Last inspected
20 May 1999
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 20 May 1999
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1983–1999)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-47632

Documentation record

Tonnage as PSIX records it3823 - Convention (Subpart B), Gross Ton
3028 - Convention (Subpart B), Net Ton
8542 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MR. DYLAN Towing Vessel · MISLE 84709 · 20 May 1999 · activity 58686CANDACE ELISE Towing Vessel · MISLE 197718 · 26 January 1992 · activity 152718

Inspection history · 30

20 May 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 58686
18 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377678
28 April 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1176390
13 July 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1176445
21 January 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451916
8 April 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414133
2 October 1992 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245950
16 September 1992 Initial Construction-Excluding Oversight
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 934175
11 September 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 107827
19 March 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316571
28 February 1992 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 952311
26 January 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 152718
9 May 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1240340
18 April 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 915653
15 April 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1218646
7 March 1991 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1226275
17 February 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233685
30 November 1989 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906641
13 February 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1343658
4 May 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1346293
4 April 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993991
29 March 1988 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297837
24 February 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025628
18 February 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1330020
10 February 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010822
29 October 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014960
28 October 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016208
3 March 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309231
23 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283537
18 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278862

Deficiency record · 18

Electrical
Issued 21 January 1994 Resolved
RENEW ALL FRAYED HOSE LENGTHS ON EMERGENCYGENERATOR HYDRAULIC ACCUMULATOR.
Condition: Unknown
Due 21 February 1994
Resolved 28 January 1994
Engineering
Issued 21 January 1994 Resolved
INSTALL METAL GUARD AROUND FUEL LEVEL SIGHTGLASS ON DIESEL FUEL TANK IN GENERATOR SPACE.
Condition: Unknown
Due 21 February 1994
Resolved 28 January 1994
Electrical
Issued 21 January 1994 Resolved
MAKE SATISFACTORY REPAIRS TO EMERGENCY GENERATOR SHUTDOWN LINKAGE SUCH THATGENERATOR ENGINE COMPLETELY SHUTS DOWN.
Condition: Unknown
Due 21 February 1994
Resolved 28 January 1994
Deck/Cargo
Issued 28 February 1992 Resolved
MAKE REPAIRS TO ALL (FOUR) CARGO HATCHES. PROVE WATERTIGHTNESS OF HATCHES IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR. VESSEL IS PROHIBITED FROM LOADING OR CARRYING CARGO UNTIL ITEM IS CLEARED.
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Documentation
Issued 28 February 1992 Resolved
PROVIDE VALID LOADLINE CERTIFICATE ON BOARD VESSEL.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992
Deck/Cargo
Issued 7 March 1991 Resolved
MAKE REPAIR TO PORT MOORING WINCH CONTROL MOUNT.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Deck/Cargo
Issued 7 March 1991 Resolved
INSTALL WINCH MOTOR AND CONDUCT OPERATIONAL TEST TO THE SATIFACTION OF COGNIZANT O.C.M.I.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Construction/Loadline
Issued 17 February 1990 Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED AREA OF THE PORT SIDE STERN (NEAR DECK LEVEL) TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 February 1990
Resolved 17 February 1990
Deck/Cargo
Issued 17 February 1990 Resolved
MAKE PERMANENT REPAIRS TO THE FORWARD ANCHOR WINDLASS AND CONDUCT OPERATIONAL TEST TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 February 1990
Resolved 17 February 1990
Electrical
Issued 17 February 1990 Resolved
REMOVE ALL WIRING AND CONDUIT PIPING ASSOCIATED WITH THE PREVIOUS NAV LIGHTSYSTEM THAT IS NO LONGER SERVICABLE AND NO LONGER IN USE.
Condition: Unknown
Due 17 February 1990
Resolved 17 February 1990
Electrical
Issued 17 February 1990 Resolved
REPLACE COVER TO ELECTRICAL JUNCTION BOX LOCATED ON BARGE'S GENERATOR.
Condition: Unknown
Due 17 February 1990
Resolved 17 February 1990
Deck/Cargo
Issued 17 February 1990 Resolved
REPLACE OR REPAIR HYDRAULIC HOSES AND FITTINGS LOCATED ON BOTH PORT AND AFTMOORING WINCHES TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 February 1990
Resolved 17 February 1990
Construction/Loadline
Issued 24 February 1988 Resolved
PROVE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR THAT THE 42"X84" INSERT ON THE STBD BOW SIDESHELL IS WATERTIGHT. 46 CFR 91.30-1.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Construction/Loadline
Issued 24 February 1988 Resolved
PROVE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR THAT THE INSERTIN THE FWD CARGO TANK BULKHEAD IS WATERTIGHT. 46 CFR 91.25-10.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Electrical
Issued 10 February 1987 Resolved
LABEL THE REMOTE STOP CABLE FOR THE BARGE GENERATOR.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Electrical
Issued 10 February 1987 Resolved
PROVIDE METAAL GUARDS AND GLOBES AS REQUIRED ON EXPLOSION PROOF LIGHT FIXTURES IN THE GENERATOR ROOM AND HYDRAULIC ROOM.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Electrical
Issued 10 February 1987 Resolved
SUBMIT TO [name withheld], LA, PROOF THAT THE NAVIGATION LIGHT FIXTURES ARE APPROVED FOR USE IN HAZARDOUS LOCATIONS (EXPLOSION PROOF) OR REPLACE WITH FIXTURES WHICH ARE EXPLOSION FROOF.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Electrical
Issued 10 February 1987 Resolved
MAKE ALL WIRING, FIXTURES AND ELECRTICAL EQUIPMENT ON THE BARGE EXPLOSION- PROOF.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.