← All vessels
KURE
Freight Ship · General Dry Cargo Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named KURE
KURE is a 1996 freight ship. The Coast Guard has recorded 39 inspections since 1998, most recently in February 2026, along with 24 deficiencies and 6 operational controls.
Records from 1998 to 2026. Most recent: inspection, 11 February 2026.
- Built
- 1996
- Last inspected
- 11 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9085522 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5MA7
476384
Flag
LIBERIA
—
Maury page id
psix-476384
Inspections, by type
…with no type recorded8
Years with a record
13 calendar years (1998–2026)
The 39 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it81488 - Convention (Subpart B), Gross Ton
46444 - Convention (Subpart B), Net Ton
96103 - Dead Weight, Metric Ton
130421 - Displacement, Metric Ton
46444 - Convention (Subpart B), Net Ton
96103 - Dead Weight, Metric Ton
130421 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 39
11 February 2026
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8306568
10 February 2026
PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8308570
14 November 2025
PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8268421
3 August 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8198275
28 July 2025
Appeal · PSC A
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8193047
24 July 2025
PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8193378
14 July 2025
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8185817
27 April 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8120760
25 April 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8120132
22 April 2025
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8117177
21 February 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8080100
13 February 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8076378
4 February 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8074313
23 October 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8018937
30 January 2024
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7852236
15 March 2023
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7651272
27 November 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6587433
30 August 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6248378
14 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6240253
27 May 2017
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6152568
8 May 2017
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6141472
1 April 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6115622
13 October 2016
ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6021585
31 August 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5984066
23 July 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5950283
25 August 2015
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5225693
29 September 2011
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4158091
7 August 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4101908
21 April 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3188282
13 February 2008
ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3146267
25 September 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3066200
23 September 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3064417
7 May 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2924249
28 February 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2879258
7 March 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2598031
31 January 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2576834
30 January 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2577160
26 January 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2573850
23 July 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 418331
Deficiency record · 24
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 10 February 2026
Resolved
Rescue boats shall be stowed in a position suitable for launching and recovery. PSCO identified rescue boat davit unable to lift rescue boat from cradle. Vessel able to use port side lifeboat as back-up rescue boat.
74 SOLAS (97) III/14.2 15ac
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 July 2025
Resolved
The company should establish procedures for the implementation of corrective action, including measures intended to prevent recurrence. Objective evidence indicates the Company has failed to ensure nonconformities are rectified. IMO detentions dated 13 Feb 2025 and 24 July 2025 identified deficiencies, and follow-up ISM audits identified nonconformities, that continue to persist. Further examination today revealed additional objective evidence of an inability to implement an effective Safety Management System.
74 SOLAS (24) IX/3.1 - ISM Code 9.2
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 July 2025
Resolved
Every oil fuel pipe shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space. Quick closing valves to numerous storage tanks and daily service tanks in groups 1, 2, 3, 4, 6, 7, 8, and 9 failed to close associated valves.
74 SOLAS (97) II-2/15.2.5
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 July 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCOs observed fuel oil leaks on the fuel injector drains associated with cylinders 3, 5, 8, 9, 10, and 12.
74 SOLAS (24) I/11
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 July 2025
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Rescue boat failed to engage into forward gear.
74 SOLAS (01) III/20.2
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 July 2025
Resolved
The ring, lines and letters shall be permanently marked on the sides of the ship. Deck line on starboard side is not permanently marked.
ILLC66 Annex I Reg. 8
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 24 July 2025
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of the deficiencies noted in deficiency 2,4,and 5 below provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency.
74SOLAS(24) IX/3.1
ISM Code 10.1
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 July 2025
Resolved
Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling or daily service tank situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed eight of the ten hydraulic reservoirs for activating the vessel's quick closing valves did not have the required amount of hydraulic fluid. Upon testing points 1,2, & 9 the crew was unable to activate the quick closing valves in a timely manner. A review of the vessel's maintenance history shows the maintenance for the system was listed as "good" on work done date, 21 June 2025. Vessel's crew refilled reservoir which drained themselves again within two hours.
74SOLAS(97) II-2/15.2.5
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 July 2025
Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration. PSCO observed main engine electronic governor system panel being artificially cooled by auxiliary fan.
74SOLAS(04) II-1/3-1
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 24 July 2025
Resolved
Four sets of full protective clothing resistant to chemical attack shall be provided in addition to the fireman's outfits required by regulation 10.10 and shall be selected taking into account the hazards associated with the chemicals being transported and the standards developed by the organization according to the class and physical state. The protective clothing shall cover all skin, so that no part of the body is unprotected. PSCO noted that all four chemical protective clothing suits had severely dry-rotted rubber seals on either the neck or wrist, making the suits ineffective in a chemical emergency. A review of the vessel's monthly checks revealed that the crew inspected the suits, but these checks did not report the observed condition.
74SOLAS(2024) II-2/19.3.6
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 24 July 2025
Resolved
Each enclosed space entry and rescue drill shall include checking and use of instruments for measuring the atmosphere in enclosed spaces. PSCO observed that the vessel's three gas meters were overdue for annual shore calibration. A review of the vessel's SMS showed worked done date 04 June 2025 as "good" despite being overdue on this date.
74SOLAS(24) III/19.3.6.2.3
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 24 July 2025
Resolved
For all ships the means for embarkation shall be inspected and maintained in a suitable condition. PSCO observed a that at the top of the gangway where the gangway connects to the ship, the bolts were missing their washers and were in danger of pulling through the connection.
74SOLAS(2024) II-1/3-9.3
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 24 July 2025
Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration. PSCO observed starboard brake motor for the anchor inoperable, causing the anchor and half a shot of chain to be released and unable to be retracked.
74SOLAS(04) II-1/3-1
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 15 February 2025
Resolved
Fire protection systems shall be maintained and ready for use. The ships fire detection system was found to be inoperable in at least five (05) zones including: CO2 room, emergency generator room, fuel/purifier separator room, workshop and Main Diesel Generator (MDG) spaces (port and starboard). Available SMS records indicates that at least some faults were present since January 5th. There was no record that flag/class was informed until the day of, and just prior to, the PSC exam, at which point a dispensation was issued.
SOLAS(2004 Cons) II-2/14.1.1 30 a/c
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 February 2025
Resolved
A secondary starting source of energy shall be provided for the emergency generator. The hydraulic accumulator for the EDG was inoperable. While SMS records demonstrate the ship reported the issue to the company on January 13, 2025, there was no objective evidence that the failure was reported to class or flag until yesterday (12 Feb 2025) when a dispensation was issued one day prior to USCG exam.
SOLAS(2004 Cons) II-1/44.2.1 30 a/c
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 15 February 2025
Resolved
Hydraulic steering gears shall be provided with audible/visual alarms on the navigation bridge to indicate a leak or loss of hydraulic fluid. These alarms were not fitted on the ships navigation bridge.
SOLAS(2004 Cons) II-1/29.12.2 17a/c
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 13 February 2025
Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company. Objective evidence indicates that the company has failed to report various deficiencies to the Administration or the Recognized Organization and failed to take appropriate corrective actions in a timely fashion resulting in repeated failures, particulary of the ships' alarm systems. An external safety management audit shall be carried out by the Administration or the RO prior to the ship being released from detention.
SOLAS(2020 Cons) IX/3.1 & ISM 10.1 30 a/c
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 13 February 2025
Resolved
Fire protection systems shall be maintained and ready for use. The ships fire detection system was found to be inoperable in at least five (05) zones including: CO2 room, emergency generator room, fuel/purifior separator room, workshop and Main Diesel Generator (MDG) spaces (port and starboard). Available SMS records indicates that at least some faults were present since January 5th. There was no record that flag/class was informed until the day of, and just prior to, the PSC exam, at which point a dispensation was issued.
SOLAS(2004 Cons) II-2/14.1.1 30 a/c
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 13 February 2025
Resolved
A secondary starting source of energy shall be provided for the emergency generator. The hydraulic accumulator for the EDG was inoperable. While SMS records demonstrate the ship reported the issue to the company on January 13, 2025, there was no objective evidence that the failure was reported to class or flag until yesterday (12 Feb 2025) when a dispensation was issued one day prior to USCG exam.
SOLAS(2004 Cons) II-1/44.2.1 30 a/c
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 13 February 2025
Resolved
Hydraulic steering gears shall be provided with audible/visual alarms on the navigation bridge to indicate a leak or loss of hydraulic fluid. These alarms were not fitted on the ships navigation bridge.
SOLAS(2004 Cons) II-1/29.12.2 17a/c
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 13 February 2025
Resolved
A clear view from navigation bridge windows shall be provided at all times. The bridge has two windows that each have spiderweb cracking over ~4ft of glass panes. Interviews of onboard deck officers indicates that the windows have been broken for at least five months and no records could be found that the ship or the company had made any attempts to repair.
SOLAS(2004 Cons) V/29.9.4 50 a/c
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 23 October 2024
Resolved
The Oil Record Book Part I shall be completed on each occasion, on a tank-to-tank basis if appropriate, whenever any of the following machinery space operations take place in the ship: bunkering of fuel or bulk lubricating oil. PSCO's observed Bunker Delivery Notes dated that was not entered into the Oil Record Book.
Cite: MARPOL Annex I Reg. 17.2.5
Code: 10c
Lifesaving › Launching Appliances › Winch Brake
Issued 30 August 2017
Resolved
0635: MANUAL BRAKES SHALL BE ARRANGED SO THAT THE BRAKE IS ALWAYS APPLIED UNLESS THE OPERATOR, EITHER ON DECK OR IN THE SURVIVAL CRAFT, HOLDS THE BRAKE CONTROL IN THE "OFF" POSITION. THE PSCO NOTED DURING THE LOWERING OF THE PORT LIFE BOAT THAT THE BRAKE REMAINED OFF WHEN THE OPERATOR LET GO. 74 SOLAS(97) III/48.2.10
Lifesaving › Launching Appliances › Winch Brake
Issued 7 August 2011
Resolved
Number 2 lifeboat could not be recovered after three attempts. Cite: 74 SOLAS (04 Con ed.) Chapter III Reg. 20.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.