Documentation record
Registered dimensions (L × B × D)135.1 ft × 36.0 ft × 10.8 ft
Registered tonnagegross 98 / net 29
ITC dimensions (L × B × D)135.1 ft × 36.0 ft × 10.8 ft
ITC tonnagegross 901 / net 293
BuilderWASHBURN & DOUGHTY ASSOCIATES INC · EAST BOOTHBAY, ME, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJACKSONVILLE, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 5 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
901 - Convention (Subpart B), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
293 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
8 November 2024
Administrative Inspection · Internal Structural Exam · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8032397
9 October 2018
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6558307
15 August 2018
Administrative Inspection · Special
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6558772
23 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6488461
30 May 2018
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6434346
16 April 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6333318
24 October 2017
Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6294335
18 October 2017
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6290212
25 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6274777
5 June 2017
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6166738
27 May 2017
MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6156701
26 May 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6156298
28 April 2017
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6134799
24 April 2017
Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6131605
20 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6129371
15 April 2017
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6126462
24 March 2017
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6110830
20 June 2016
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5938725
31 May 2016
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5969831
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 March 2025
Resolved
Observed and UT readings reflected areas of excessive wastage of bottom hull plating in Pump Room, Galley Bilge, Lazarette, and excessive wastage in several areas on the Port & Stbd side shells, and isolated deep pits in BT Tube. Attending MI required all areas wasted more than 25% of original to be cropped out and renewed. For specific areas, see St. John's Ship Yard 2025 Steel Repair drawings, 4 pages.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2026
Resolved 22 December 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 October 2018
Resolved
Vessel was issed a Captain of the Port order and failed to follow the order.
Action required: 705 - Other - as specified
Due 10 October 2018
Resolved 19 February 2019
Resolution: 19FEB19: COTP Order 051-18 rescinded.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 18 October 2017
Resolved
No bridge to bridge certificate on board and operating in a VTS zone.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 November 2017
Resolution: certificates reissued
Electrical › Electric Generation Source (service) › Generator
Issued 5 June 2017
Resolved
Vessel experienced a failure of a head on the #2 ship service generator. Restore generator to proper operation to the satisfaction of the attending Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2017
Resolution: Replaced Head tested SSDG under load all sat.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 5 June 2017
Resolved
Furniture such as chairs, sofas, and similar items must satisfy the UL 1056 "Fire Test of Upholstered Furniture" or be constructed of non-combustible materials under 46 CFR 72.05. Provide evidence to the attending Coast Guard marine inspector that all chairs/sofas comply with the above requirements prior to carrying >150 passengers.
Action required: 705 - Other - as specified
Resolved 12 June 2017
Resolution: Found historic evidence of compliance.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 5 June 2017
Resolved
Rugs and carpets must be constructed of 100 percent wool or equivalent as determined by a flame spread rating not exceeding 75 and a smoke developed rating not exceeding 100 when tested according to ASTM E 84 or have a critical radiant flux not less than 0.8 watts per square centimeter when tested according to ASTM E 648 and with a specific optical density...see narrative for full def.
Action required: 705 - Other - as specified
Resolved 10 June 2017
Resolution: Found historic evidence of compliance.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 20 April 2017
Resolved
Provide pre-employment drug testing results for crewmembers as defined 46 CFR 16.105, or provide documentation for pre-employment waiver for reason as defined 46 CFR 16.210(b)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2017
Resolution: Verified 15 negative pre-employment DOT 5 Panel Drug Test results. Verified documentation for 7 employees with documentation for transferring from an active Marine Drug Testing Program.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 April 2017
Resolved
Provide documentation all crewmembers required to submit for random drug testing are listed in selection pool.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2017
Resolution: Verified Employee Drug Testing Pool (22 employees) for Cruises to Nowhere LLC licensed crewmembers & safety sensitive position employees.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 20 April 2017
Resolved
Provide documentation that all crewmembers are as defined in 46 CFR 16.105 are properly trained before assuming safety sensitive positions.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2017
Resolution: Received documentation of all employees and 3 supervisors EAP training as required.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 20 April 2017
Resolved
Provide documentation of employee consent and attempt or results of drug test background check. 40CFR 40.25
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2017
Resolution: Verified documentation of drug test background check or verified company background was requested for but not obtainable.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 20 April 2017
Resolved
Provide documenataion of 2016 MIS report and all negative test results within 1 year.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 26 May 2017
Resolution: Local submision to DAPI Auditor in lieu of submission to inoperable USCG webpage.
Construction/Loadline › Structures › Superstructure
Issued 15 April 2017
Resolved
4"-5" wide crack on the portside covering 3/4 length of the VSL between 2nd and 3rd deck, structural crack on port loading door on 2nd deck. Make overhead space available by removing overhead in affected area for attending MI to conduct full inspection of damge.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2017
Resolved 21 April 2017
Resolution: Space made available.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 April 2017
Resolved
Replace both expired floating waterlights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2017
Stability › Watertight Integrity › General
Issued 5 April 2017
Resolved
Prior to carrying passengers make temp. repairs to aft lazaret hatch to the satisfaction of the USCG inspector attending with full replacement of the watertight hatch in 30days.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2017
Resolved 4 May 2017
Resolution: New hatch installed
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 5 April 2017
Resolved
Replace all plastic trash cans with approved non-combustible waste receptacles.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 4 May 2017
Resolution: Metal cans provided
Engineering › Pressure Vessel › Relief Valve
Issued 5 April 2017
Resolved
Install pressure-temperature relief device on pump room water heater.
Action required: 705 - Other - as specified
Resolved 4 May 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 April 2017
Resolved
Prove proper operation of all self closing doors.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 27 May 2017
Resolution: All fire doors operating in sat condition.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 April 2017
Resolved
Prove proper operation and marking of all ventilation fire dampers
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 4 May 2017
Resolution: Witnessed closing of all vent dampers
Fire Fighting › Fire Hoses › Condition
Issued 31 May 2016
Resolved
Replace worn fire hose IAW 46 CFR 118.320
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 31 May 2016
Resolution: Replaced in kind prior to completion of inspection. All sat.
Construction/Loadline › Structures › Door
Issued 31 May 2016
Resolved
Remove holdbacks on fire door in main vertical stairwell to comply w/ self-closing requirements of 46 CFR 116.435(c)(6)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 31 May 2016
Resolution: Hold backs removed as directed prior to completion of inspection. All sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 May 2016
Resolved
Remove electrical wiring IVO upper deck accommodation not in compliance w/ 46 CFR 120.340 (extension cord in overhead).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 31 May 2016
Resolution: Extension cord removed from overhead prior to completion of the inspection. All sat.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 31 May 2016
Resolved
Provide evidence of proper operation of all emergency lighting IAW 46 CFR 120.432(b)(A)(1).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 15 June 2016
Resolution: Provided satisfactory demonstration of emergency lighting functionality. All sat.
Engineering › Fuel Oil Service System › Filter
Issued 31 May 2016
Resolved
Install missing flame impingement bowls IAW 46 CFR 119.455(b)(5)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 15 June 2016
Resolution: Flame impingement bowls properly installed as directed. All sat.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 31 May 2016
Resolved
Provide non-conductive matting IVO of main switchboard as required by 46 CFR 120.330(g)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 15 June 2016
Resolution: Non-conductive mats provided as directed. All sat.