MAURY USCG vessel records Sign in
← All vessels

DREAMERS

DREAMERS is a 1998 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1998, most recently in November 2024, along with 165 deficiencies, 3 operational controls and 14 casualty investigations between 2001 and 2018.

Records from 1998 to 2024. Most recent: inspection, 8 November 2024.

Built
1998
Last inspected
8 November 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF6261
476396
Flag
UNITED STATES
367377040, 367472370 (licence lapsed)
Maury page id
psix-476396

Inspections, by type

…with no type recorded30
Years with a record 21 calendar years (1998–2024)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)135.1 ft × 36.0 ft × 10.8 ft
Registered tonnagegross 98 / net 29
ITC dimensions (L × B × D)135.1 ft × 36.0 ft × 10.8 ft
ITC tonnagegross 901 / net 293
BuilderWASHBURN & DOUGHTY ASSOCIATES INC · EAST BOOTHBAY, ME, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
901 - Convention (Subpart B), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
293 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF6261MMSI 367472370 · expired · compulsorily equipped · granted 23 November 2010, cancelled 23 January 2021
WDE6182MMSI 367377040 · expired · compulsorily equipped · granted 16 September 2008, cancelled 17 November 2018
WCY6695MMSI not assigned · expired · compulsorily equipped · granted 1 September 1998, cancelled 1 November 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 79

8 November 2024 Administrative Inspection · Internal Structural Exam · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8032397
9 October 2018 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6558307
15 August 2018 Administrative Inspection · Special
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6558772
23 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6488461
30 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6434346
16 April 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6333318
24 October 2017 Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6294335
18 October 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6290212
25 September 2017 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6274777
5 June 2017 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6166738
27 May 2017 MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6156701
26 May 2017 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6156298
28 April 2017 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6134799
24 April 2017 Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6131605
20 April 2017 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6129371
15 April 2017 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6126462
24 March 2017 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6110830
20 June 2016 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5938725
31 May 2016 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5969831
21 September 2015 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5720872
18 June 2014 Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4892296
12 June 2012 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4341522
1 June 2012 Excursion Permit
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4331176
10 February 2012 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4241900
26 September 2011 Drydock Exam · In-Service Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4154291
29 July 2011 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4129656
3 December 2010 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3917525
17 February 2010 In-Service Inspection · MTSA Verification · Administrative Inspection · DAPI Audit · Deficiency Check · Deadweight Survey · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3726136
15 December 2009 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3650706
15 September 2008 Periodic Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3420929
14 September 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3339552
15 February 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3149591
6 November 2007 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3098960
3 September 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3054331
29 June 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2985498
31 May 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2951050
4 May 2007 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2927594
19 April 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2929886
6 October 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2795318
3 September 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2787413
10 August 2006 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2742581
2 August 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2751133
31 July 2006 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2731465
26 October 2005 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2535116
2 August 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2448709
13 July 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2433154
1 July 2005 Hull Examination · Internal Structural Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2406524
25 April 2005 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2343842
28 January 2005 In-Service Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2282523
26 December 2004 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2265145
10 December 2004 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2256999
10 December 2004 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2257017
9 December 2004 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2256954
7 December 2004 Administrative Inspection
Administrative · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2255120
18 October 2004 MTSA Verification · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2219977
1 August 2004 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2155901
4 June 2004 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2124715
21 April 2004 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2049431
18 February 2004 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2008300
30 January 2004 Drydock Extension
Administrative · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1997670
14 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1985098
29 October 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1935419
6 September 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1934275
4 July 2003 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1838116
7 June 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1927262
18 November 2002 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1933913
30 October 2002 MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1697434
16 August 2002 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1667214
6 February 2002 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1484416
1 August 2001 COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1473290
15 May 2001 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1604393
10 October 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1450533
14 May 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 47841
24 February 2000 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1361342
2 August 1999 MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1369314
6 June 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 213864
16 April 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1124063
14 August 1998 MARPOL Annex V Examination · Initial Certification
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1131119
14 April 1998 Hull Examination · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 795170

Deficiency record · 165

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 March 2025 Resolved
Observed and UT readings reflected areas of excessive wastage of bottom hull plating in Pump Room, Galley Bilge, Lazarette, and excessive wastage in several areas on the Port & Stbd side shells, and isolated deep pits in BT Tube. Attending MI required all areas wasted more than 25% of original to be cropped out and renewed. For specific areas, see St. John's Ship Yard 2025 Steel Repair drawings, 4 pages.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2026
Resolved 22 December 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 October 2018 Resolved
Vessel was issed a Captain of the Port order and failed to follow the order.
Action required: 705 - Other - as specified
Due 10 October 2018
Resolved 19 February 2019
Resolution: 19FEB19: COTP Order 051-18 rescinded.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 18 October 2017 Resolved
No bridge to bridge certificate on board and operating in a VTS zone.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 November 2017
Resolution: certificates reissued
Electrical › Electric Generation Source (service) › Generator
Issued 5 June 2017 Resolved
Vessel experienced a failure of a head on the #2 ship service generator. Restore generator to proper operation to the satisfaction of the attending Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2017
Resolution: Replaced Head tested SSDG under load all sat.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 5 June 2017 Resolved
Furniture such as chairs, sofas, and similar items must satisfy the UL 1056 "Fire Test of Upholstered Furniture" or be constructed of non-combustible materials under 46 CFR 72.05. Provide evidence to the attending Coast Guard marine inspector that all chairs/sofas comply with the above requirements prior to carrying >150 passengers.
Action required: 705 - Other - as specified
Resolved 12 June 2017
Resolution: Found historic evidence of compliance.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 5 June 2017 Resolved
Rugs and carpets must be constructed of 100 percent wool or equivalent as determined by a flame spread rating not exceeding 75 and a smoke developed rating not exceeding 100 when tested according to ASTM E 84 or have a critical radiant flux not less than 0.8 watts per square centimeter when tested according to ASTM E 648 and with a specific optical density...see narrative for full def.
Action required: 705 - Other - as specified
Resolved 10 June 2017
Resolution: Found historic evidence of compliance.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 20 April 2017 Resolved
Provide pre-employment drug testing results for crewmembers as defined 46 CFR 16.105, or provide documentation for pre-employment waiver for reason as defined 46 CFR 16.210(b)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2017
Resolution: Verified 15 negative pre-employment DOT 5 Panel Drug Test results. Verified documentation for 7 employees with documentation for transferring from an active Marine Drug Testing Program.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 April 2017 Resolved
Provide documentation all crewmembers required to submit for random drug testing are listed in selection pool.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2017
Resolution: Verified Employee Drug Testing Pool (22 employees) for Cruises to Nowhere LLC licensed crewmembers & safety sensitive position employees.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 20 April 2017 Resolved
Provide documentation that all crewmembers are as defined in 46 CFR 16.105 are properly trained before assuming safety sensitive positions.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2017
Resolution: Received documentation of all employees and 3 supervisors EAP training as required.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 20 April 2017 Resolved
Provide documentation of employee consent and attempt or results of drug test background check. 40CFR 40.25
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2017
Resolution: Verified documentation of drug test background check or verified company background was requested for but not obtainable.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 20 April 2017 Resolved
Provide documenataion of 2016 MIS report and all negative test results within 1 year.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 26 May 2017
Resolution: Local submision to DAPI Auditor in lieu of submission to inoperable USCG webpage.
Construction/Loadline › Structures › Superstructure
Issued 15 April 2017 Resolved
4"-5" wide crack on the portside covering 3/4 length of the VSL between 2nd and 3rd deck, structural crack on port loading door on 2nd deck. Make overhead space available by removing overhead in affected area for attending MI to conduct full inspection of damge.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2017
Resolved 21 April 2017
Resolution: Space made available.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 April 2017 Resolved
Replace both expired floating waterlights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2017
Stability › Watertight Integrity › General
Issued 5 April 2017 Resolved
Prior to carrying passengers make temp. repairs to aft lazaret hatch to the satisfaction of the USCG inspector attending with full replacement of the watertight hatch in 30days.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2017
Resolved 4 May 2017
Resolution: New hatch installed
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 5 April 2017 Resolved
Replace all plastic trash cans with approved non-combustible waste receptacles.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 4 May 2017
Resolution: Metal cans provided
Engineering › Pressure Vessel › Relief Valve
Issued 5 April 2017 Resolved
Install pressure-temperature relief device on pump room water heater.
Action required: 705 - Other - as specified
Resolved 4 May 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 April 2017 Resolved
Prove proper operation of all self closing doors.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 27 May 2017
Resolution: All fire doors operating in sat condition.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 April 2017 Resolved
Prove proper operation and marking of all ventilation fire dampers
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 4 May 2017
Resolution: Witnessed closing of all vent dampers
Fire Fighting › Fire Hoses › Condition
Issued 31 May 2016 Resolved
Replace worn fire hose IAW 46 CFR 118.320
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 31 May 2016
Resolution: Replaced in kind prior to completion of inspection. All sat.
Construction/Loadline › Structures › Door
Issued 31 May 2016 Resolved
Remove holdbacks on fire door in main vertical stairwell to comply w/ self-closing requirements of 46 CFR 116.435(c)(6)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 31 May 2016
Resolution: Hold backs removed as directed prior to completion of inspection. All sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 May 2016 Resolved
Remove electrical wiring IVO upper deck accommodation not in compliance w/ 46 CFR 120.340 (extension cord in overhead).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 31 May 2016
Resolution: Extension cord removed from overhead prior to completion of the inspection. All sat.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 31 May 2016 Resolved
Provide evidence of proper operation of all emergency lighting IAW 46 CFR 120.432(b)(A)(1).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 15 June 2016
Resolution: Provided satisfactory demonstration of emergency lighting functionality. All sat.
Engineering › Fuel Oil Service System › Filter
Issued 31 May 2016 Resolved
Install missing flame impingement bowls IAW 46 CFR 119.455(b)(5)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 15 June 2016
Resolution: Flame impingement bowls properly installed as directed. All sat.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 31 May 2016 Resolved
Provide non-conductive matting IVO of main switchboard as required by 46 CFR 120.330(g)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 15 June 2016
Resolution: Non-conductive mats provided as directed. All sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 February 2012 Resolved
Prove proper operation of all navigation lights. Navigation lights for vessel not under command were inoperable.
Due 14 March 2012
Resolved 24 February 2012
Resolution: Navigation lights were made operational.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 February 2012 Resolved
Properly log Broadcast Notice to Mariners and prove charts are being corrected.
Due 28 February 2012
Resolved 13 March 2012
Resolution: The charts were updated and the BNM''s are being maintained/updated.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 February 2012 Resolved
Properly remove or terminate wires beneath bridge console.
Due 28 February 2012
Resolved 24 February 2012
Resolution: Wires were nonenergized and capped.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 14 February 2012 Resolved
Replace structural fire protection - Engine room, port side, under blower motor.
Due 14 March 2012
Resolved 13 March 2012
Resolution: A new piece of SFP was installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 February 2012 Resolved
Double clamp wet cooler system, port side, main diesel engine exhaust.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2012
Resolution: Wet cooler system was double clamped.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 February 2012 Resolved
Install pipe hanger by reduction gear, both port and stbd side in engine room.
Due 14 March 2012
Resolved 24 February 2012
Resolution: Installed pipe hanger.
Electrical › Electric Generation Source (service) › Generator
Issued 14 February 2012 Resolved
Replace or repair stbd generator exhaust "4" - current temporary repair unsatisfactory.
Due 14 March 2012
Resolved 24 February 2012
Resolution: Cut off and welded new end cap.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 February 2012 Resolved
Properly remove or terminate dead wire in rudder space.
Due 28 February 2012
Resolved 24 February 2012
Resolution: Wired was removed.
Engineering › Fuel Oil Service System › Valve
Issued 14 February 2012 Resolved
Label fuel oil shut off valves located on stern deck.
Due 21 February 2012
Resolved 24 February 2012
Resolution: Valves labeled.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 24 May 2011 Resolved
Update Emergency Evacuation Plan, Escape Hatch Engine Room, and Fire and Safety Plans, to show the current/correct configuration and the current status of the vessel's fire and lifesaving equipment.
Action required: 705 - Other - as specified
Due 24 June 2011
Resolved 2 August 2011
Resolution: DRAWING APPROVED BY OCMI - CID LTR 046-11
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 24 May 2011 Resolved
Correct and update DC One Line drawing diagram to reflect current condition of the vessel, and submit to CG Sector Jacksonville for review/approval.
Action required: 705 - Other - as specified
Due 24 June 2011
Resolved 20 July 2011
Resolution: One line drawing was submitted and approved.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 24 May 2011 Resolved
Complete requirements noted IAW CG MSC letter S/N: E2-1100956, dtd April 07, 2011, and provide CG Sector Jacksonville with the drawings/documents for review/approval prior to CG witnessing testing procedures.
Action required: 705 - Other - as specified
Due 24 June 2011
Resolved 20 July 2011
Resolution: It was determined that a smoke detector IWO the E/R was not required.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 7 April 2011 Resolved
[name withheld], [phone withheld], [email withheld] CG Sector Jacksonville, FL Boarded the vessel on 07April2011 to correct previously issued deficiencies. I informed the vessel Captain of the requirements for the EPA Vessel General Permit. Captain was provided VGP regulation/contact information. The Captain was on the phone today to obtain VGP and will follow up with our office.
Action required: 705 - Other - as specified
Due 31 May 2011
Resolved 24 May 2011
Resolution: Vessel in compliance with VGP requirements.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 7 April 2011 Resolved
Provide updated/revised Electrical Load Analysis drawing as per comments provided by CG Marine Safety Center letter dated 17March2011. Contact CG Sector Jacksonville when a response is provided by CG Marine Safety Center for a Marine Inspector to witness/verify.
Action required: 705 - Other - as specified
Due 31 May 2011
Resolved 24 May 2011
Resolution: Vessel satisfactorily completed 3 hour load analysis; drawing will need to be updated/corrected to reflect current configuration - new CG-835 will be issued.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 18 January 2011 Resolved
Provide updated Coast Guard MSC approved drawings for Fire Detection.
Action required: 705 - Other - as specified
Due 31 May 2011
Resolved 24 May 2011
Resolution: Updated approved drawings submitted - Additional CG-835 written to provide them to CG Sector Jacksonville for review and testing of system.
Electrical › Electric Supply System (service) › Cable
Issued 18 January 2011 Resolved
Provide updated Coast Guard Marine Safety Center approved drawings for electrical one-line drawing diagram.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 7 April 2011
Resolution: Witnessed reviewed/approved drawings for electrical on-line drawing diagram.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 18 January 2011 Resolved
Provide updated Coast Guard Marine Safety Center approved drawings for electrical load analysis.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 7 April 2011
Resolution: Witnessed "examined" drawings for electrical load analysis and response letter from CG Marine Safety Center.
Construction/Loadline › Structures › Scuttle
Issued 18 January 2011 Resolved
Provide proposed plan and/or location for emergency escape scuttle from the engine room.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 7 April 2011
Resolution: Witnessed removal of slot machine machine IWO emergency escape scuttle as well as proper signage marking location of emergency escape.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 November 2010 Resolved
Install emergency ligting IWO each head on the 01 and 02 deck
Action required: 705 - Other - as specified
Due 10 December 2010
Resolved 10 December 2010
Resolution: Emergency lighting installed and opertional.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 November 2010 Resolved
Update/amend the fire and safety plan to remove rescue boat and add manual fire dampners IWO the engine room.
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 26 November 2010
Resolution: Fire and safety plan correctly amended reflecting the vessels current state.
Communications › Alarms/Indicators › Fire Alarm
Issued 24 November 2010 Resolved
Prove proper operation of the fire pull box located on the 01 deck outside the stairwell.
Action required: 705 - Other - as specified
Due 10 December 2010
Resolved 10 December 2010
Resolution: Fire box pulled station operated properly.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 November 2010 Resolved
Install larger/legable fire and safety plans on each deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2010
Resolution: Fire and safety plans were installed as directed.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 November 2010 Resolved
Provide proof of EAP training to applicable crewmembers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2010
Resolution: Training log with signatures provided as proof.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 24 November 2010 Resolved
Provide operating instructions and training to applicable crewmembers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2010
Resolution: Operating instructions posted and training proof provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 6 November 2007 Resolved
The port MDE exhaust pipe needs to be replaced from the through hull up to and including the first flex coupling.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 15 September 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 6 November 2007 Resolved
port MDE exhaust is leaking from the forward muffler where it attaches to the rubber flex coupling, repair leak.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 15 September 2008
Construction/Loadline › Penetrations › Gasket
Issued 6 November 2007 Resolved
The gasket for the hatch cover to the lazarette was missing, also the seat for the hatch needs to be cleaned.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 15 September 2008
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 6 November 2007 Resolved
The door to the oven did not have the required latches to prevent accidental opening in heavy weather.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 6 November 2007
Navigation › Piloting/Steering › Swing Meter
Issued 6 November 2007 Resolved
The bridge wing rudder angle indicators were out of adjustment and did not show the same information as the one on the bridge.
Due 6 December 2007
Resolved 6 November 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 August 2006 Resolved
Renew/ repair raw water flow switch for Stbd MDE.
Action required: 705 - Other - as specified
Due 18 August 2006
Resolved 14 August 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 10 August 2006 Resolved
Renew/ repair raw water flow switch for # 1Gen set .
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 14 August 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 10 August 2006 Resolved
Renew/ repair raw water flow switch for # 2 Gen set .
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 14 August 2006
Lifesaving › Buoyant Apparatus › Serviceable
Issued 10 August 2006 Resolved
Have all inflatable Buoyant apparratus serviced.
Due 31 October 2006
Resolved 27 November 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 August 2006 Resolved
Renew/ Repair and recharge the powder fire extinguisher located in the wheelhouse.
Condition: Improper/Lack of Maintenance
Due 16 August 2006
Resolved 14 August 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 10 August 2006 Resolved
Procure an up to date light list.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 14 August 2006
Documentation › Logs/Records › Garbage Recordkeeping
Issued 10 August 2006 Resolved
Provide a garbage log.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 14 August 2006
Operations/Management › Pollution › Control of Garbage
Issued 10 August 2006 Resolved
Provide a garbage plan.
Condition: Unknown
Due 16 August 2006
Resolved 14 August 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 10 August 2006 Resolved
Add CO2 extinguisher for paint locker to Fire safety Plan (FCP & EEP)
Due 31 August 2006
Resolved 14 August 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 August 2006 Resolved
Renew all fire door latches with 0.75 inches in length they are currently 0.5. To be completed at next yard period but not later than 28 Feb 06
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 15 September 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 August 2006 Resolved
Repair latch on fire door located on stbd side 2nd deck to stairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2006
Resolved 12 December 2006
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 August 2006 Resolved
Repair latch on fire door located on port side 2nd deck to Focs'le. Renew handle on the adjacent door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2006
Resolved 12 December 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 August 2006 Resolved
Renew fire door hold back on stbd side 2nd deck to stairs.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 16 August 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 10 August 2006 Resolved
Renew missing light covers located in 1st to 2nd deck port stair (egress )
Condition: Damaged By Earlier Event
Due 15 September 2006
Resolved 12 December 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 August 2006 Resolved
Restow ramp at entry way on port side so that it does not interfer with magnetic hold back on the fire door.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 14 August 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 10 August 2006 Resolved
Address the cause of breaker # 7 on gaming panel G2 tripping as soon as it is reset.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 August 2006
Resolved 12 December 2006
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 10 August 2006 Resolved
Ensure all audible and visual alarms for the fixed fire detection system are operational.
Action required: 705 - Other - as specified
Due 30 August 2006
Resolved 12 December 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 August 2006 Resolved
Properly install cable clamp through bulkhead located in access space above sewage compartment and behind the main deck change counter.
Condition: Improper Installation
Due 30 August 2006
Resolved 12 December 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 August 2006 Resolved
Remove extension cord from behind the maindeck change counter to beneath the slot machines.
Condition: Improper Installation
Due 16 August 2006
Resolved 14 August 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 10 August 2006 Resolved
Remove all power strips beneath gaming machines and install appropriate receptacles or terminal strips.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 August 2006
Resolved 12 December 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 August 2006 Resolved
Renew/repair stbd main deck fire door latch.
Condition: Improper/Lack of Maintenance
Due 16 August 2006
Resolved 14 August 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 August 2006 Resolved
Remove all extension cords to plasma TV's on all decks. Instal permanent wiring meetin 46 CFR 120.340.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 14 August 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 10 August 2006 Resolved
Renew/Repair the emergency exit sign on 2nd deck forward.
Condition: Improper/Lack of Maintenance
Due 16 August 2006
Resolved 14 August 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 10 August 2006 Resolved
Renew bulb and cover in way of the 2nd deck bar.
Condition: Improper/Lack of Maintenance
Due 20 August 2006
Resolved 12 December 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 10 August 2006 Resolved
Properly secure the CO2 bottles located at the waitress station on the 2nd deck.
Condition: Improper Installation
Due 16 August 2006
Resolved 14 August 2006
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 10 August 2006 Resolved
Provide an accurate list of vessels fire detection zones corresponding to the main pannel.
Condition: Improper Installation
Due 16 August 2006
Resolved 14 August 2006
Construction/Loadline › Structures › Door
Issued 10 August 2006 Resolved
Remove and clean all tonnage doors to weather decks.
Condition: Improper/Lack of Maintenance
Due 16 August 2006
Resolved 11 August 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 August 2006 Resolved
Service all portable fire extinguishers.
Due 16 August 2006
Resolved 14 August 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 August 2006 Resolved
Service all fixed fire extinguishing systems.
Due 16 August 2006
Resolved 16 August 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 August 2006 Resolved
Renew line for the aft lifebuoy>
Condition: Unknown
Due 16 August 2006
Resolved 14 August 2006
Lifesaving › Rocket Parachute Flares › General
Issued 10 August 2006 Resolved
Change EEP/FCP to reflect actual required VDS on board.
Condition: Unknown
Due 31 August 2006
Resolved 14 August 2006
Fire Fighting › Fire Pumps › Power Source
Issued 10 August 2006 Resolved
Install a drip shield on the Fire pump's motor controller.
Condition: Improper Installation
Due 16 August 2006
Resolved 14 August 2006
Engineering › Thrusters › Motor
Issued 10 August 2006 Resolved
Address and correct the cause of the bow thrusters control circuits shorting out . Due at next drydock but not later than te due date.
Action required: 705 - Other - as specified
Due 28 February 2007
Resolved 14 June 2007
Resolution: Controler moved outsid the engineroom. Was not designed to operate in temperatures of a machinery space.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 10 August 2006 Resolved
Address and correct the cause of the HVAC system tripping off line when generators are run in normal conditions. ( cords holding open the throttles.) (Due at next dry dock but not later than the due date.)
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 6 November 2007
Resolution: Replaced faulty switch, problem resolved.
Construction/Loadline › Penetrations › Pipe Flange
Issued 10 August 2006 Resolved
Install appropriate glands on the through deck penetrations between the sewage compartment and air handling space. To be completed at next dry dock availability but no later than due date.
Condition: Improper Installation
Due 28 February 2007
Resolved 14 June 2007
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 10 August 2006 Resolved
Provide an engineer as required by MSU Savannah's MSIB 01-06.
Due 31 August 2006
Resolved 14 August 2006
Resolution: Engineer hired.
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 10 August 2006 Resolved
Install Structural fire insulation (A 60) in the air handling compartment located above the sewage compartment to extend doen the bulkhead 12 inches from the existing insulation beneath the stairs. Due at next drydock but not later than the due date.
Condition: Improper Installation
Due 28 February 2007
Resolved 14 June 2007
Resolution: Installed
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 26 October 2005 Resolved
Ensure all circut breakers are properly labeled and missing breakers are blanked off.
Condition: Improper/Lack of Maintenance
Due 27 October 2005
Resolved 27 October 2005
Resolution: corrected
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 26 October 2005 Resolved
Provide load analysis for circuit feeding rescue boat winch and permanently install suitable wiring.
Condition: Design Flaw
Due 30 November 2005
Resolved 26 October 2005
Resolution: Hand operated winch installed
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 October 2005 Resolved
Provide double hose clamps on the number two generator raw water cooling.
Condition: Improper/Lack of Maintenance
Due 15 November 2005
Resolved 30 May 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 26 October 2005 Resolved
Renew all trash receptacles with non-combustible materials.
Condition: Improper Installation
Due 15 November 2005
Resolved 30 May 2006
Documentation › Markings/Placards › Warning Signs
Issued 26 October 2005 Resolved
Stencil all escape hatches as per 46 CFR122.606
Condition: Improper/Lack of Maintenance
Due 15 November 2005
Resolved 30 May 2006
Operations/Management › Drills/Instruction › Fire
Issued 26 October 2005 Resolved
Update Fire Safety Emergency evacuation Plan to include all fire suppression equipment.
Condition: Improper/Lack of Maintenance
Due 30 November 2005
Resolved 14 August 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 October 2005 Resolved
Remove all hose clamps from exhaust system and renew with appropriate double t clamps.
Condition: Improper/Lack of Maintenance
Due 30 November 2005
Resolved 30 May 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 October 2005 Resolved
Remove all PVC exhaust cooling piping on port main engine. Renew with appropriate metallic materials.
Condition: Improper/Lack of Maintenance
Due 15 November 2005
Resolved 14 August 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 October 2005 Resolved
Reinstall RTD for flow alarm in the port main engine (PVC piping change) and connect alarm.
Condition: Improper/Lack of Maintenance
Due 15 November 2005
Resolved 30 May 2006
Engineering › Fuel Oil Service System › Gauge
Issued 26 October 2005 Resolved
Renew fuel sight glass with heat resistant material.
Condition: Improper Installation
Due 30 November 2005
Resolved 12 December 2006
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 26 October 2005 Resolved
Fuel tank sight glass valve shall be renewed with self closing valves.
Condition: Improper Installation
Due 28 February 2007
Resolved 14 June 2007
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 26 October 2005 Resolved
Resize anchor and ground tackle for appropriate size vessel as per manufactures recommendations.
Condition: Improper Installation
Due 28 September 2007
Resolved 23 November 2010
Resolution: As per OCMI approval, the vessel got underway, released and proved proper operation and anchor and ground tackle. The anchor and ground tackle appropriately held the vessel in place to the satisfaction of the attending marine inspectors.
Engineering › Thrusters › Piping
Issued 26 October 2005 Resolved
Repair hydraulic leaks on bow thruster and forward winch systems.
Condition: Improper/Lack of Maintenance
Due 15 November 2005
Resolved 30 May 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 October 2005 Resolved
Renew the flex coupling in the port main engine in way of aft bulkhead.
Condition: Improper/Lack of Maintenance
Due 15 November 2005
Resolved 30 May 2006
Construction/Loadline › Penetrations › Weld
Issued 26 October 2005 Resolved
Make permanant repairs to the leak in the Port side fuel tank, in way of fuel sight glass.
Condition: Improper/Lack of Maintenance
Due 31 July 2006
Resolved 12 December 2006
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 26 October 2005 Resolved
Provide vessel electricla oneline and load analysis for review not later than 15 June 2006.
Condition: Unknown
Due 28 February 2007
Resolved 14 June 2007
Resolution: Existing installations verified. Additionally some gaming electronics removed since original installation.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 26 October 2005 Resolved
Renew/repair emergency lighting at Port gangway entrance, prior to getting underway with passengers.
Condition: Improper/Lack of Maintenance
Due 31 May 2006
Resolved 29 June 2006
Engineering › Steering Gear System › Ram Seal
Issued 18 October 2004 Resolved
Replace seal in starboard steering ram.
Due 18 November 2004
Resolved 3 November 2004
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 18 October 2004 Resolved
Properly secure stall wall in men's head 2nd deck.
Due 18 November 2004
Resolved 3 November 2004
Fire Fighting › Ventilation Systems › Ducts
Issued 18 October 2004 Resolved
Properly install fire damper auto closure device in way of overhead vent, 2nd deck port side stern.
Due 18 November 2004
Resolved 18 November 2004
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 October 2004 Resolved
Clean behind all bars.
Due 18 November 2004
Resolved 18 November 2004
Electrical › Electric Supply System (service) › Cable
Issued 18 October 2004 Resolved
Remove extension cords behind bars, hardwire outlets were needed.
Due 18 November 2004
Resolved 3 November 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 18 October 2004 Resolved
Repair and prove proper operation of fresh air intake closure devices 1st and 2nd deck.
Due 17 December 2004
Resolved 5 January 2005
Construction/Loadline › Structures › Superstructure
Issued 18 October 2004 Resolved
Submit plans for 3rd deck plexiglasss/ aluminum wall. Alternative is to knock it down.
Due 7 January 2005
Resolved 18 November 2004
Resolution: Plans mailed to MSFO 18Oct04.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 18 October 2004 Resolved
Owner/operator has a transverse bulkhead installed on the upper deck, this is now an enclosed space behind existing tonnage openings, remove bulkhead or have the vessel admeasured for tonnage.
Due 28 February 2005
Resolved 1 July 2005
Resolution: Vessel has opening in bulkhead
Stability › Watertight Integrity
Issued 18 February 2004 Resolved
Remove standing water from bilge fwd of the collision bulkhead LEGACY COMPONENT DESC: Bilge
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 21 April 2004
Accommodation/Occupational Safety
Issued 18 February 2004 Resolved
Repair leak to sanitary tank piping stbd side. LEGACY COMPONENT DESC: Sewage Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 21 April 2004
Accommodation/Occupational Safety
Issued 18 February 2004 Resolved
Remove temp repair (flex) piping on sanitation tank and make permanent repairs. LEGACY COMPONENT DESC: Flex Sanitary Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 21 April 2004
Engineering › Thrusters
Issued 18 February 2004 Resolved
Repair Bow Thruster hydraulic piping leak in pump room. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 21 April 2004
Electrical › Electrical Distribution System (service)
Issued 18 February 2004 Resolved
Remove power cord near bar area on second deck & install outlet receptacle. LEGACY COMPONENT DESC: Power Cord
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 21 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 18 February 2004 Resolved
Replace inkind cracked glass on port/stbd white doors adjacent to pilothouse. LEGACY COMPONENT DESC: Windows
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 18 February 2004 Resolved
Replace cracked glass on port side, fwd door leading to forcastle. LEGACY COMPONENT DESC: Windows
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 21 April 2004
Construction/Loadline › Structures
Issued 18 February 2004 Resolved
Adjust closures on 3 doors IWO 3rd deck. LEGACY COMPONENT DESC: Doors
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 21 April 2004
Engineering › Steering Gear System
Issued 30 October 2002 Resolved
Repair bowthruster contorl on stbd bridge wing. LEGACY COMPONENT DESC: Actuator
Condition: Improper/Lack of Maintenance
Due 20 November 2002
Resolved 19 November 2002
Communications › Alarms/Indicators
Issued 30 October 2002 Resolved
Repair stbd bridge wing engine tachometers. LEGACY COMPONENT DESC: Propeller Revolutions Rate Indicator
Condition: Improper/Lack of Maintenance
Due 20 November 2002
Resolved 19 November 2002
Communications › Alarms/Indicators
Issued 30 October 2002 Resolved
Repair bilge alarm in pump room. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Due 20 November 2002
Resolved 19 November 2002
Engineering › Steering Gear System
Issued 30 October 2002 Resolved
Repair/renew pipe hangers for bowthruster piping in the pump room. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 20 November 2002
Resolved 19 November 2002
Construction/Loadline › Penetrations
Issued 30 October 2002 Resolved
Repair wire penetrations for all bhd & deck boundaries were proper strain relief, chaffing & sealing appliances are not used.
Condition: Improper Installation
Due 20 November 2002
Resolved 19 November 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 30 October 2002 Resolved
Renew exhaust piping blanket for stbd engine. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 27 December 2002
Resolved 6 January 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 30 October 2002 Resolved
service fixed CO2 system for engine space in the presence of a C.G. Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 27 December 2002
Resolved 6 January 2003
Electrical
Issued 30 October 2002 Resolved
Remove wire nuts from electrical connections in engine monitoring wiring harness.
Condition: Improper Installation
Due 20 November 2002
Resolved 19 November 2002
Operations/Management › Drug and Alcohol Testing
Issued 30 October 2002 Resolved
Provide proof of MIS submital for drug screening program. LEGACY COMPONENT DESC: MIS Submission
Condition: Unknown
Due 6 November 2002
Resolved 5 November 2002
Operations/Management › Drug and Alcohol Testing
Issued 30 October 2002 Resolved
Provide list of "supervisors" & date each received their one hour training. LEGACY COMPONENT DESC: EAP Training Requirements
Condition: Unknown
Due 6 November 2002
Resolved 5 November 2002
Construction/Loadline › Markings
Issued 23 January 2002 Resolved
Permanently affix 7 ft draft marks on hull both fore and aft. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 6 February 2002
Resolved 30 October 2002
Fire Fighting › Means of Escape
Issued 23 January 2002 Resolved
Permanently install device to make escape hatch in engine room operable from inside engine room.
Due 6 February 2002
Resolved 30 October 2002
Construction/Loadline › Structures
Issued 23 January 2002 Resolved
Install captive device to hatch cover to lazarette. LEGACY COMPONENT DESC: Manhole
Due 6 February 2002
Resolved 6 February 2002
Documentation
Issued 1 August 2001 Resolved
POST EMPLOYEE ASSISTANCE PROGRAM.
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Lifesaving
Issued 1 August 2001 Resolved
UPDATE EMERGENCY PROCEDURES PLACARD TO BE VESSEL SPECIFIC.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Documentation
Issued 1 August 2001 Resolved
UPDATE CREWLIST COVERED BY CONSORTIUM.
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Electrical
Issued 1 August 2001 Resolved
ENCLOSE WIRE NUTS FOR SPLICES OR REPLACE NUTS WITH CRIMP CONNECTORS AND TAPE.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Lifesaving
Issued 1 August 2001 Resolved
REMOVE CHILD LIFE JACKET LOCATION MARKINGS.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Lifesaving
Issued 1 August 2001 Resolved
REPLACE EYEWASH AND OINTMENT IN FIRST AID KITS.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Documentation
Issued 1 August 2001 Resolved
PROVIDE SUPERVISOR TRAINING.
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Engineering
Issued 1 August 2001 Resolved
DEMONSTRATE POWER FAILURE TEST OF MICROPROCESSOR FOR BRIDGE CONTROL (46 CFR121.620).
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Lifesaving
Issued 1 August 2001 Resolved
REPLACE PENDANTS ON LIFE FLOATS THAT ARE FRAYING.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Lifesaving
Issued 1 August 2001 Resolved
CONDUCT FIREFIGHTING, MAN OVERBOARD AND ABANDON SHIP DRILS IN ACCORDANCE WITH 46 CFR 122.520 AND 122.524.
Condition: Unknown
Due 1 August 2001
Resolved 1 August 2001
Lifesaving
Issued 10 October 2000 Resolved
HYDROSTATIC RELEASE FOR EPIRB HAS NO DATE. PROVIDE DOCUMENTATION OF LAST TEST OR REPAIR/RENEW.
Condition: Unknown
Due 7 November 2000
Resolved 7 November 2000
Construction/Loadline
Issued 10 October 2000 Resolved
WTD ON STBD SIDE MAINDECK NEEDS NEW GASKET. REPAIR/RENEW
Condition: Unknown
Due 7 November 2000
Resolved 7 November 2000
Engineering
Issued 10 October 2000 Resolved
SIGHT GLASS ON BOTH FUEL TANKS ARE NOT SELF CLOSING AND ARE NOT APPROVED MARINE TYPE. THE VALVE ON THE PORT FUEL TANK LEAKS. GAUGES ARE TO BE AN APPROVED MARINE TYPE WITH SELF CLOSING VALVES. VALVES ARE TO BE KEPT CLOSEDUNTIL CORRECTED
Condition: Unknown
Due 10 October 2000
Resolved 10 October 2000
Engineering
Issued 10 October 2000 Resolved
MAIN ENGINE MUFFLERS LEAK IN AFTER STEERING. CENTER GENERATOR MUFFLER LEAKSFWD OF MUFFLER. REPAIR/RENEW
Condition: Unknown
Due 7 November 2000
Resolved 7 November 2000
Documentation
Issued 10 October 2000 Resolved
PROVIDE DOCUMENTATION FROM CONSORTIUM ON DRUG TESTING PROGRAM.
Condition: Unknown
Due 7 November 2000
Resolved 7 November 2000
Fire Fighting
Issued 2 August 1999 Resolved
INSTALL A RED COVER OVER FIRE ALARM STROBE LIGHT ON BRIDGE TO PREVENT BLINDING VESSEL [name withheld] IN THE EVENT THE WHITE STROBE LIGHT GOES OFF.
Condition: Unknown
Due 7 August 1999
Resolved 18 August 1999
Accommodation/Occupational Safety
Issued 2 August 1999 Resolved
RESTENCIL EMERGENCY ESCAPE HATCH FM E/R TO MAIN DECK AND REMOVE CHAIR OR RELOCATE SLOT MACHINE IWO THIS ESCAPE HATCH. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 2 August 1999
Resolved 18 August 1999
Fire Fighting
Issued 2 August 1999 Resolved
INSTALL A COUNTER WEIGHT AND GASKET ON STBD SIDE E/R VENT FAN OPENING AND AGASKET ON THE PORT E/R VENT FAN OPENING.
Condition: Unknown
Due 2 September 1999
Resolved 18 August 1999
Construction/Loadline
Issued 2 August 1999 Resolved
LABEL VALVE IN WOMENS HEAD ON 1ST DECK, FOREPEAK SECTION WHICH MUST BE CLOSED PRIOR TO PUMPING BILGE.
Condition: Unknown
Due 2 September 1999
Resolved 18 August 1999
Accommodation/Occupational Safety
Issued 2 August 1999 Resolved
PROPERLY SECURE MICROWAVE OVEN AND REFRIDGERATOR IN CREW BREAK ROOM. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 3 August 1999
Resolved 18 August 1999
Documentation
Issued 2 August 1999 Resolved
PROVIDE AND POST FCC RADIO SAFETY TELEPHONY CERTIFICATE. NO PASSENGERS FORHIRE UNTIL CLEARED.
Condition: Unknown
Due 3 August 1999
Resolved 18 August 1999
Electrical
Issued 2 August 1999 Resolved
SHOW OPERATION OF EMERGENCY LIGHTING IN GALLEY AND PORTSIDE MAIN DECK ENTRANCE._x001C_ _x001C_ NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 3 August 1999
Resolved 18 August 1999
Construction/Loadline
Issued 2 August 1999 Resolved
PROVIDE AND INSTALL PROPER SCREEN OVER DRAIN IN CRASH COMPT.
Condition: Unknown
Due 2 September 1999
Resolved 18 August 1999
Fire Fighting
Issued 2 August 1999 Resolved
HAVE FIXED FIRE FIGHTING SYSTEM SERVING RANGE HOOD IN GALLEY SERVICED._x001C_ _x001C_ _x001C_ NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 3 August 1999
Resolved 18 August 1999
Construction/Loadline
Issued 2 August 1999 Resolved
PROVE THAT BILGE SUCTION FROM CRASH COMPT. HAS A CHECK VALVE INSTALLED IN THE PIPING TO PREVENT BACK FLOW OF WATER.
Condition: Unknown
Due 2 September 1999
Resolved 18 August 1999
Unknown
Issued 14 August 1998 Resolved
SHOW COMPLIANCE W/CG DRUG TESTING REGS.
Condition: Unknown
Due 30 September 1998
Resolved 6 October 1998
Lifesaving
Issued 14 August 1998 Resolved
SHOW PROOF OF EPIRB REGISTRATION.
Condition: Unknown
Due 14 October 1998
Resolved 1 September 1998
Unknown
Issued 14 August 1998 Resolved
LABEL MAXIMUM NUMBER OF PASSENGERS PER DECK AS ALLOWED BY VESSELS STABILITYLETTER.
Condition: Unknown
Due 21 August 1998
Resolved 1 September 1998
Lifesaving
Issued 14 August 1998 Resolved
PROVIDE INFLATABLE PRIMARY LIFE SAVING EQUIPMENT PRIOR TO OPERATING DURING COLD WATER MONTHS.
Condition: Unknown
Due 30 November 1998
Resolved 2 November 1998

Casualty record · 14

15 May 2001Routine · role: Involved in a Marine Casualty · 1 injured · activity 1604393
4 June 2004Routine · role: Involved in a Marine Casualty · 1 injured · activity 2124715
25 April 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2343842
13 July 2005Routine · role: Involved in a Marine Casualty · activity 2433154
3 September 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2787413
19 April 2007Routine · role: Involved in a Marine Casualty · activity 2929886
31 May 2007Routine · role: Involved in a Marine Casualty · activity 2951050
29 June 2007Routine · role: Involved in a Marine Casualty · activity 2985498
4 August 2007Routine · role: Involved in a Marine Casualty · activity 3051744
3 September 2007Routine · role: Involved in a Marine Casualty · activity 3054331
14 September 2008Routine · role: Involved in a Marine Casualty · activity 3339552
12 June 2011Routine · role: Involved in a Marine Casualty · activity 4045878
12 April 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4567766
16 April 2018Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6333318
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 3

MIDNIGHT GAMBLER II (2001–2008), JACKS OR BETTER CASINO (2011–2013), JACKS OR BETTER 1 (2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.