MAURY USCG vessel records Sign in
← All vessels

SUNSET QUEEN

SUNSET QUEEN is a 1973 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1984, most recently in July 2007, along with 220 deficiencies and 2 casualty investigations between 2004 and 2007.

Records from 1984 to 2007. Most recent: inspection, 9 July 2007.

Built
1973
Last inspected
9 July 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ7292
Flag
UNITED STATES
367005720 (licence lapsed)
Maury page id
psix-47651

Inspections, by type

…with no type recorded13
Years with a record 24 calendar years (1984–2007)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCZ7292MMSI 367005720 · expired · compulsorily equipped · granted 28 March 2000, cancelled 29 May 2010
WCX7202MMSI not assigned · expired · compulsorily equipped · granted 4 September 1997, cancelled 10 November 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 72

9 July 2007 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2989068
27 March 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2896128
27 January 2007 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2863560
26 January 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2862698
25 October 2006 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2807917
21 April 2006 COI Inspection · MARPOL Annex V Examination · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2640508
8 September 2005 Deficiency Check · MTSA Verification · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2486919
8 June 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2385822
19 April 2005 Damage Survey · Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2337536
7 September 2004 Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2188854
27 July 2004 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2146389
13 July 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2131364
5 July 2004 Administrative Inspection · MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2122177
4 July 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2122252
4 July 2004 Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 2130845
8 September 2003 MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1899628
6 September 2002 Deficiency Check · Hull Examination · Administrative Inspection · Annual Inspection · Internal Structural Exam · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1680045
15 May 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1627329
29 April 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1611809
21 March 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1495812
8 June 2001 Inclining Experiment
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1063010
8 June 2001 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1373576
12 April 2001 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1062299
11 April 2001 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1062561
26 March 2001 Hull Examination · Construction Oversight
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1423551
9 March 2001 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1059723
28 February 2001 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058345
19 June 2000 Hull Examination · Construction Oversight
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1397546
18 April 2000 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051823
16 March 2000 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1424870
5 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 813484
30 September 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1348029
24 August 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1372733
5 August 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 795710
24 June 1998 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1449074
31 January 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1428915
23 December 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1117823
17 December 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1111034
10 September 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1121610
20 August 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1119291
4 August 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1119531
27 June 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781195
17 January 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 878626
20 December 1995 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441004
16 December 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420894
14 December 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1159600
18 November 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 849315
2 March 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 665665
14 January 1993 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1136304
15 October 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 960067
15 October 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 960627
10 October 1991 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1251591
19 September 1991 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 941754
28 November 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 919255
20 November 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214898
5 November 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 906492
10 October 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1219489
26 May 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1238701
6 February 1990 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1219552
13 October 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 897518
13 October 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227267
10 October 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227143
29 November 1988 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1207293
17 October 1988 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 887770
20 September 1988 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1193786
19 October 1987 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1023089
6 April 1987 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1022565
24 October 1986 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1325301
19 November 1985 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 993378
24 October 1985 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1301036
13 September 1985 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1297607
25 October 1984 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 979020

Deficiency record · 220

Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2006 Resolved
SECURE LIGHTING WIRE IN #2 VOID AS DISCUSSED WITH DECKHAND.
Due 9 May 2006
Resolved 4 May 2006
Resolution: WIRE SECURED WITH METAL BRACKETS.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2006 Resolved
PUT SPLICE IN BOX IN HOLDING TANK SPACE.
Due 9 May 2006
Resolved 4 May 2006
Resolution: VIEWED SPLICE ON WIRES.
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 April 2006 Resolved
REPAIR LEAKS ON POWER STEERING GEAR BOXES.
Due 9 May 2006
Resolved 4 May 2006
Resolution: LEAKS REPAIRED.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 21 April 2006 Resolved
DRY OUT BATTERY BOXES IN ENGINE ROOM
Due 9 May 2006
Resolved 4 May 2006
Resolution: BATTERY BOXES DRYED OUT.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 April 2006 Resolved
INSTALL EMERGENCY LIGHTING OVERHEAD OF BILGE MANIFOLD.
Due 9 May 2006
Resolved 4 May 2006
Resolution: INSTALLED.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 21 April 2006 Resolved
INSTALL SEA RAILS ON ALL OPEN RANGE STOVES AND GRIDDLES.
Due 9 May 2006
Resolved 4 May 2006
Resolution: SEA RAILS INSTALLED.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 April 2006 Resolved
REMOVE SOFT PATCH AND INSTALL HARD PIPING ON COOLING WATER LINE ON STBD GENERATOR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2006
Resolution: SOFT PATCH REMOVED AND HARD PIPE INSTALLED.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 21 April 2006 Resolved
REMOVE AND PROPERLY DISPOSE OF HYDRAULIC OIL IN ENGINE ROOM BILGE.
Due 9 May 2006
Resolved 4 May 2006
Resolution: OIL REMOVED.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 April 2006 Resolved
REPAIR LEAK AND LOOSE FITTINGS ON WATER LINE OUTBOARD SIDE OF STDB ENGINE.
Due 9 May 2006
Resolved 3 May 2006
Resolution: LEAK AND LOOSE FITTINGS REPAIRED.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 21 April 2006 Resolved
ARRANGE EQUIPMENT AND TABLE IN LOWER GALLEY SO THAT FIRE DOOR HAS FREE MOVEMENT.
Due 9 May 2006
Resolved 4 May 2006
Resolution: EQUIPMENT MOVED.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 21 April 2006 Resolved
REPAIR OIL FILTER LEAKS ON PORT ENGINE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2006
Resolution: OIL FILTER LEAKS REPAIRED.
Engineering › Steering Gear System › Helix Shaft
Issued 21 April 2006 Resolved
TIGHTEN SHAFT PACKING ON BOTH SHAFTS.
Due 9 May 2006
Resolved 3 May 2006
Resolution: SHAFT PACKING TIGHTENED.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 April 2006 Resolved
REPAIR VHF ANTENNA
Due 9 May 2006
Resolved 3 May 2006
Resolution: ANTENNA REPAIRED.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 April 2006 Resolved
RE - LABEL ELECTRICAL PANEL (BILGE ALARMS) ON BRIDGE.
Due 9 May 2006
Resolved 3 May 2006
Resolution: PANEL RE - LABELED.
Navigation › Collision/Grounding Avoidance › Radar
Issued 21 April 2006 Resolved
REPAIR INOPERABLE RADAR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2006
Resolution: RADAR REPAIRED.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 April 2006 Resolved
UPDATE ALL NAVIGATION PUBS.
Due 9 May 2006
Resolved 3 May 2006
Resolution: ALL NAV PUBS UPDATED.
Electrical › Lighting (service) › Outlet Box
Issued 21 April 2006 Resolved
REPLACE LIGHTS ON BILGE HIGH LEVEL ALARM PANEL.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2006
Resolution: LIGHTS REPLACED.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 April 2006 Resolved
UPDATE FIRST AID KIT.
Due 9 May 2006
Resolved 3 May 2006
Resolution: FIRST AID KIT UPDATED.
Fire Fighting › Fire Pumps › Pressure
Issued 21 April 2006 Resolved
PROVE PROPER OPERATION OF POWER DRIVEN FIRE PUMP TO THE SAT OF THE ATTENDING CG MI.
Action required: 705 - Other - as specified
Resolved 3 May 2006
Resolution: TESTED, ALL SAT.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 21 April 2006 Resolved
PROVIDE ADDITIONAL B-II CLASS EXTINGUISHER.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2006
Resolution: ADDITIONAL EXTINGUSIHER PROVIDED.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 September 2005 Resolved
Update the following navigation publications: US Coast Pilot, CG Light List, Tide Tables, and Current Tables.
Due 1 October 2005
Resolved 21 September 2005
Resolution: Viewed updated Nav pubs.
Lifesaving › Hand Flares › Expired
Issued 8 September 2005 Resolved
Provide (3) red hand flares and (3) orange day smokes or proper substitution.
Due 1 October 2005
Resolved 21 September 2005
Resolution: Viewed (3) red hand flares and (3) orange day smokes.
Documentation › Markings/Placards › Official Number (US)
Issued 8 September 2005 Resolved
Fill in Emergency Broadcast placard to make vessel specific.
Due 1 October 2005
Resolved 21 September 2005
Resolution: Viewed vsl specific emergency broadcast placard.
Lifesaving › Lifefloat › Lifeline
Issued 8 September 2005 Resolved
Replace line on (5) waterlight lanyards on lifefloats as discussed with vsl rep.
Due 1 October 2005
Resolved 21 September 2005
Resolution: Line on waterlight lanyards replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 September 2005 Resolved
Update first aid kit (missing/expired meds).
Due 1 October 2005
Resolved 21 September 2005
Resolution: Viewed update first aid kit.
Engineering › Bilge Water Management System › Not Operational
Issued 8 September 2005 Resolved
Repair visual indicator on bilge high level alarm panel.
Due 1 October 2005
Resolved 21 September 2005
Resolution: Viewed visual indicator on bilge high level alarm.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 8 September 2005 Resolved
Tighten/replace shaft packing stbd. side.
Due 1 October 2005
Resolved 21 September 2005
Resolution: Shaft packing tightened.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 8 September 2005 Resolved
Install rubber mating on port and stbd side stairs leading into E/R IWO circuit panels.
Due 1 October 2005
Resolved 21 September 2005
Resolution: Viewed installed rubber mating on port and stbd side stairs leading into E/R.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 September 2005 Resolved
Permanently affix passenger lifejacket boxes.
Due 1 October 2005
Resolved 21 September 2005
Resolution: Lifejacket boxes permanently affixed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 September 2005 Resolved
Properly affix PVC pipe in MSD void space. Remove wire from light fixture.
Due 1 October 2005
Resolved 21 September 2005
Resolution: Wires removed from light fixture, and PVC pipe is secured.
Documentation › Markings/Placards › Warning Signs
Issued 8 September 2005 Resolved
Properly label (placard) emergency exits (in the bow)
Due 1 October 2005
Resolved 21 September 2005
Resolution: Emergency exits properly labeled.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 8 September 2005 Resolved
Properly post pax emergency evacuation plan.
Due 1 October 2005
Resolved 19 October 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 September 2005 Resolved
Properly adjust latch on stbd side fwd. door on third deck.
Due 1 October 2005
Resolved 19 October 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 September 2004 Resolved
Install proper size water light lanyard on port side top deck lifering bouy (3-6 ft is proper).
Due 25 September 2004
Resolved 16 September 2004
Resolution: 6 ft lanyard installed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 September 2004 Resolved
Clean out accumulated trash under galley stove and counters as needed.
Due 25 September 2004
Resolved 16 September 2004
Resolution: Trashed removed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 September 2004 Resolved
Remove rusted drum of anti-freeze from aft starboard side deck.
Due 25 September 2004
Resolved 16 September 2004
Resolution: Drum removed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 September 2004 Resolved
Conduct fire and man overboard drill prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2004
Resolved 16 September 2004
Resolution: Conducted satisfactory underway MOB and fire drills.
Stability › Watertight Integrity › Coaming
Issued 7 September 2004 Resolved
Make proper repairs to watertight door in engine room, prior to carrying passengers -chalk test-
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2004
Resolved 16 September 2004
Resolution: Edge of watertight door thruway was filed down to make a level surface. Performed satisfactory chalk test.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 September 2004 Resolved
Properly terminate pig tailed cord plugged in under deep fat fryer on top deck.
Condition: Improper/Lack of Maintenance
Due 25 September 2004
Resolved 16 September 2004
Resolution: Pig tailed cord plug was replaced by 3 prong plug.
Engineering › Steering Gear System
Issued 8 September 2003 Resolved
Prover proper operation of Port Hydraulic steering pump. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 1 October 2003
Resolution: Steering pump rebuilt and tested, sat.
Engineering › Bilge Water Management System
Issued 8 September 2003 Resolved
Prove proper operation of engine driven bilge pump installed on Stbd engine. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 1 October 2003
Resolution: Sat test of belt driven bilge pump, dewatered fwd void.
Navigation
Issued 8 September 2003 Resolved
Provide updated NavRules Publication 2D LEGACY COMPONENT DESC: Nav Rules Publication
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 September 2003
Resolved 1 October 2003
Resolution: Updated Nav Rules.
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 September 2003 Resolved
Replace expired meds in first aid kit. LEGACY COMPONENT DESC: Meds
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 September 2003
Resolved 1 October 2003
Resolution: Expired meds replaced.
Engineering › Generator (propulsion-electric)
Issued 8 September 2003 Resolved
Install machinery guards on Port/Stbd diesel generators.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 1 October 2003
Resolution: Guards installed.
Engineering
Issued 8 September 2003 Resolved
Double hose clamp flex hose on stbd eng after coolers. LEGACY COMPONENT DESC: After cooler
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 1 October 2003
Resolution: All flex hoses double clamped.
Stability › Watertight Integrity
Issued 8 September 2003 Resolved
Properly seal wire penetration on fwd blkd in lazarette. LEGACY COMPONENT DESC: Lazarette (fwd blkhd)
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 1 October 2003
Resolution: Sealed wire penetration in laz.
Engineering › Shafting/Propeller Arrangements
Issued 8 September 2003 Resolved
Repack port engine shaft. Shaft leaking excessively. LEGACY COMPONENT DESC: Shaft log packing
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 September 2003
Resolved 1 October 2003
Resolution: Port shaft repacked.
Electrical
Issued 8 September 2003 Resolved
Pull out dead end wires penetrating E/R watertight bulkhead and permanently seal. LEGACY COMPONENT DESC: Dead end wires
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 September 2003
Resolved 1 October 2003
Resolution: Wires pulled out and penetration sealed.
Fire Fighting › Fire Pumps
Issued 8 September 2003 Resolved
Replace fire pump gauge - inop LEGACY COMPONENT DESC: Gauge
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 1 October 2003
Resolution: Fire pump guage replaced.
Electrical
Issued 8 September 2003 Resolved
Remove electrical surge protector from 2nd deck pantry. LEGACY COMPONENT DESC: surge protector
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 1 October 2003
Resolution: Surge protector removed.
Electrical
Issued 8 September 2003 Resolved
Properly enclose electric control box for dishwasher 2nd deck (plastic housing cracked) LEGACY COMPONENT DESC: Dishwasher
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 October 2003
Resolved 1 October 2003
Resolution: New plastic housing installed.
Construction/Loadline
Issued 8 September 2003 Resolved
Replace window main deck aft stbd side. LEGACY COMPONENT DESC: Window
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 1 October 2003
Resolution: Main deck window replaced.
Electrical
Issued 8 September 2003 Resolved
Replace electrical box cover for A/C electric control in E/R. LEGACY COMPONENT DESC: AC Electrical Box
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 1 October 2003
Resolution: Electrical box cover replaced.
Engineering
Issued 8 September 2003 Resolved
Remount vent cover on side of main switchboard in E/R. LEGACY COMPONENT DESC: Vent cover
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 1 October 2003
Resolution: Vent cover remounted.
Stability › Watertight Integrity
Issued 8 September 2003 Resolved
Properly seal w/flange and plug overboard drain in transome. LEGACY COMPONENT DESC: Overboard drain
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 1 October 2003
Resolution: Sealed overboard drain in transome.
Electrical
Issued 8 September 2003 Resolved
Properly seal junction box above 3rd deck canopy IWO stern light. LEGACY COMPONENT DESC: Junction Box
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 1 October 2003
Resolution: electrical box sealed above canopy.
Engineering › Bilge Water Management System
Issued 8 September 2003 Resolved
Replace collapsed flex hose on belt driven fire/bilge pump on Stbd engine. LEGACY COMPONENT DESC: Hose
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 1 October 2003
Resolution: Flex hose replaced and did not collapse while operating belt driven pump.
Fire Fighting
Issued 8 September 2003 Resolved
Re-install all missing insulation on Port/Stbd engine room bulkheads. LEGACY COMPONENT DESC: Insulation
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 1 October 2003
Resolution: All E/R insulation replaced on all blkds.
Electrical › Electrical Distribution System (service)
Issued 6 September 2002 Resolved
Remove or properly terminate dead ended wires beneath TV shelf in wheelhouse. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 13 September 2002
Resolved 1 October 2002
Electrical › Electrical Distribution System (service)
Issued 6 September 2002 Resolved
Install cover to light switch cover in wheelhouse LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Due 13 September 2002
Resolved 1 October 2002
Lifesaving › Lifejacket/PFD (General)
Issued 6 September 2002 Resolved
Place lifejacket donning placards on bulkheads & in conspicious locations for passengers to see
Condition: Improper Installation
Due 13 September 2002
Resolved 1 October 2002
Construction/Loadline › Penetrations
Issued 6 September 2002 Resolved
Make fore & aft bulkhead penetrations in tank space watertight.
Condition: Improper/Lack of Maintenance
Due 27 September 2002
Resolved 1 October 2002
Documentation › Logs/Records
Issued 6 September 2002 Resolved
Provide training log and indicate date and general description of training given. LEGACY COMPONENT DESC: Logbook (official)
Due 13 September 2002
Resolved 1 October 2002
Navigation › Piloting/Steering
Issued 6 September 2002 Resolved
Provide U.S. Coast Pilot [name withheld] List, Tide Tables & Tidal Current Tables for vessel.
Due 13 September 2002
Resolved 10 October 2002
Documentation › Certificates/Documents
Issued 6 September 2002 Resolved
Provide copy of FCC Safety Certificate. LEGACY COMPONENT DESC: FCC SSL
Due 20 September 2002
Resolved 16 October 2002
Documentation › Certificates/Documents
Issued 6 September 2002 Resolved
Provide copy of Certificate Of Documentation LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 20 September 2002
Resolved 1 October 2002
Documentation › Markings/Placards
Issued 6 September 2002 Resolved
Provide Station Bill IAW 46 CFR 122.514
Due 13 September 2002
Resolved 21 October 2002
Operations/Management › Lifesaving
Issued 6 September 2002 Resolved
Make passenger count either verbally or in writing & available ashore.
Due 13 September 2002
Resolved 1 October 2002
Lifesaving › Rigid Liferafts
Issued 6 September 2002 Resolved
Renew retro-reflective tape to lifefloats as necessary. LEGACY COMPONENT DESC: Markings
Condition: Improper/Lack of Maintenance
Due 13 September 2002
Resolved 1 October 2002
Lifesaving › Lifebuoys
Issued 6 September 2002 Resolved
Replace unservicable lifebuoys (2)
Condition: Improper/Lack of Maintenance
Due 9 September 2002
Resolved 1 October 2002
Lifesaving › Lifejacket/PFD (General)
Issued 6 September 2002 Resolved
Re-label 1st deck lifejacket stowage to reflect actual numbers LEGACY COMPONENT DESC: Storage
Condition: Design Flaw
Due 13 September 2002
Resolved 1 October 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 September 2002 Resolved
Provide first aid kit which complies with contents of 46CFR160.041
Condition: Design Flaw
Due 20 September 2002
Resolved 10 October 2002
Fire Fighting › Miscellaneous Items
Issued 6 September 2002 Resolved
Provide fire axe & mount in or near wheelhouse.
Due 13 September 2002
Resolved 1 October 2002
Fire Fighting › Fire Pumps
Issued 6 September 2002 Resolved
Prove proper operation of stbd fire pump (belt driven)
Condition: Design Flaw
Due 13 September 2002
Resolved 10 October 2002
Engineering › Fuel Oil Service System › Vent Pipe
Issued 8 June 2001 Resolved
Main Deck - Renew stbd fuel vent flame screens w/ 30 x 30 mesh.
Due 8 June 2001
Resolved 8 June 2001
Resolution: Renewed
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 8 June 2001 Resolved
Make permanent repairs to spliced shore tie cable.
Due 8 June 2001
Resolved 8 June 2001
Resolution: Repaired
Deck/Cargo
Issued 8 June 2001 Resolved
Make stage pivot pin secure @ both ends.
Due 8 June 2001
Resolved 8 June 2001
Resolution: Repaired
Deck/Cargo
Issued 8 June 2001 Resolved
Provide retention pins for boom pivot pin
Due 8 June 2001
Resolved 8 June 2001
Resolution: Repaired
Deck/Cargo
Issued 8 June 2001 Resolved
Permanently attach main deck ladder to main deck and 01 deck.
Due 8 June 2001
Resolved 8 June 2001
Resolution: Attached
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 June 2001 Resolved
Provide proper rails/courses/dodgers in railings on main deck.
Due 8 June 2001
Resolved 8 June 2001
Resolution: Installed
Construction/Loadline › Structures › Manhole
Issued 8 June 2001 Resolved
Provide locking mechanism for fore peak hatch, clean gasket and connect retention chain.
Due 8 June 2001
Resolved 8 June 2001
Resolution: Installed
Accommodation/Occupational Safety
Issued 8 June 2001 Resolved
01 Deck - Secure TVs.
Due 8 June 2001
Resolved 8 June 2001
Resolution: Secured
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 June 2001 Resolved
Install blanks for missing circuit breakers in electrical panel.
Due 8 June 2001
Resolved 8 June 2001
Resolution: Installed
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 June 2001 Resolved
Remove unused phase wires in electrical panel.
Due 8 June 2001
Resolved 8 June 2001
Resolution: Removed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 June 2001 Resolved
Provide proper rails/courses/dodgers in railings on 01 deck.
Due 8 June 2001
Resolved 8 June 2001
Accommodation/Occupational Safety
Issued 8 June 2001 Resolved
Secure ice machines.
Due 8 June 2001
Resolved 8 June 2001
Resolution: Secured
Accommodation/Occupational Safety
Issued 8 June 2001 Resolved
Secure galley equipment.
Due 8 June 2001
Resolved 8 June 2001
Fire Fighting › Grease Extraction Hood
Issued 8 June 2001 Resolved
02 Deck - Move to safe location manual release for fixed fire fighting actuation LEGACY COMPONENT DESC: Fire Extinguishing manual release
Due 8 June 2001
Resolved 8 June 2001
Resolution: Moved
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 June 2001 Resolved
Install cable grommet where passes through steel bulkhead under bar.
Due 8 June 2001
Resolved 8 June 2001
Fire Fighting › Structural Fire Protection - General › Column/Stanchion Construction
Issued 8 June 2001 Resolved
Remove wooden handrails in stair tower to 02 deck.
Due 8 June 2001
Resolved 8 June 2001
Electrical › Lighting (service) › Lighting Fixture
Issued 8 June 2001 Resolved
Remove temporary work lights.
Due 8 June 2001
Resolved 8 June 2001
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 June 2001 Resolved
Repair/replace/prove proper operation of Nav lights.
Due 8 June 2001
Resolved 8 June 2001
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 8 June 2001 Resolved
Compartment #1 - Re-stuff all bulkhead penetrations (aft).
Due 8 June 2001
Resolved 8 June 2001
Resolution: Re-stuffed
Accommodation/Occupational Safety › Occupational Safety
Issued 8 June 2001 Resolved
Remove construction debris. LEGACY COMPONENT DESC: Sanitary Conditions
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline › Hull
Issued 8 June 2001 Resolved
Reinstall lower vertical plate stiffeners in stbd void. LEGACY COMPONENT DESC: Side Shell
Due 8 June 2001
Resolved 8 June 2001
Engineering › Bilge Water Management System › Piping
Issued 8 June 2001 Resolved
Remove flexible connection for bilge suction (hard pipe).
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline › Hull
Issued 8 June 2001 Resolved
Remove unused copper lines and plug bulkhead in outboard voids. LEGACY COMPONENT DESC: Watertight bulkhead penetrations
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline › Hull
Issued 8 June 2001 Resolved
Compartment #3 - Stuff penetrations in fwd bulkhead. LEGACY COMPONENT DESC: Watertight bulkhead penetrations
Due 8 June 2001
Resolved 8 June 2001
Accommodation/Occupational Safety › Occupational Safety
Issued 8 June 2001 Resolved
Compartment #2 - Remove debris. LEGACY COMPONENT DESC: Sanitary conditions
Due 8 June 2001
Resolved 8 June 2001
Electrical › Lighting (service) › Lighting Fixture
Issued 8 June 2001 Resolved
Install globes and guards for light fixtures.
Due 8 June 2001
Resolved 8 June 2001
Engineering › Bilge Water Management System › Piping
Issued 8 June 2001 Resolved
Hard pipe bilge suction line in compartment 3.
Due 8 June 2001
Resolved 8 June 2001
Accommodation/Occupational Safety › Cooking Systems
Issued 8 June 2001 Resolved
Prep Area - Secure warmer. LEGACY COMPONENT DESC: Warmer
Due 8 June 2001
Resolved 8 June 2001
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 8 June 2001 Resolved
MSD Space - Provide pipe hangars for all PVC piping.
Due 8 June 2001
Resolved 8 June 2001
Engineering › Bilge Water Management System
Issued 8 June 2001 Resolved
Complete float switch installation for buoyancy compartment located below MSD space. LEGACY COMPONENT DESC: Alarm
Due 8 June 2001
Resolved 8 June 2001
Electrical › Electric Supply System (service)
Issued 8 June 2001 Resolved
Provide electrical cover for sewage pump. LEGACY COMPONENT DESC: Protection
Due 8 June 2001
Resolved 8 June 2001
Accommodation/Occupational Safety › Occupational Safety
Issued 8 June 2001 Resolved
Clean debris from bilge area. LEGACY COMPONENT DESC: Sanitary Conditions
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline › Hull
Issued 8 June 2001 Resolved
Cut and cap 3 unused pipes which terminate in MSD space. LEGACY COMPONENT DESC: Water tight bulkhead penetrations
Due 8 June 2001
Resolved 8 June 2001
Engineering › Fuel Oil Service System › Filter
Issued 8 June 2001 Resolved
Provide flame impingement bowls for fuel filters for main engines.
Due 8 June 2001
Resolved 8 June 2001
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 8 June 2001 Resolved
Provide electrical cover for air pressure switch.
Due 8 June 2001
Resolved 8 June 2001
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 8 June 2001 Resolved
Hydrostatically test air receiver in presence of Marine Inspector.
Due 8 June 2001
Resolved 8 June 2001
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 June 2001 Resolved
Install/replace lagging on both generators. LEGACY COMPONENT DESC: Exhaust lagging
Due 8 June 2001
Resolved 29 April 2002
Resolution: Lagging replaced on both generators.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 June 2001 Resolved
Secure batteries - port/stbd.
Due 8 June 2001
Resolved 8 June 2001
Engineering › Diesel Engine (auxiliary)
Issued 8 June 2001 Resolved
Properly support generator water supply lines. LEGACY COMPONENT DESC: Cooling water line
Due 8 June 2001
Resolved 8 June 2001
Engineering › Diesel Engine (auxiliary)
Issued 8 June 2001 Resolved
Remove PVC piping from port generator water supply lines. LEGACY COMPONENT DESC: Cooling water line
Due 8 June 2001
Resolved 8 June 2001
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 June 2001 Resolved
Repair aft emergency light.
Due 8 June 2001
Resolved 8 June 2001
Electrical › Lighting (service) › Lighting Fixture
Issued 8 June 2001 Resolved
Replace light globes and guards throughout engine room.
Due 8 June 2001
Resolved 8 June 2001
Fire Fighting › Fire Main
Issued 8 June 2001 Resolved
Remove flexible hose from bilge/fire system @ engine driven pump. LEGACY COMPONENT DESC: Piping
Due 8 June 2001
Resolved 8 June 2001
Accommodation/Occupational Safety › Occupational Safety
Issued 8 June 2001 Resolved
Pilot House - Properly install windshield wiper. LEGACY COMPONENT DESC: Windshield wiper
Due 8 June 2001
Resolved 8 June 2001
Accommodation/Occupational Safety
Issued 8 June 2001 Resolved
Properly install loud hailer. LEGACY COMPONENT DESC: Loud hailer
Due 8 June 2001
Resolved 8 June 2001
Communications › Audible Communications
Issued 8 June 2001 Resolved
Provide 300mm (11.8") bell. LEGACY COMPONENT DESC: Ships Bell
Due 8 June 2001
Resolved 8 June 2001
Engineering › Bilge Water Management System
Issued 8 June 2001 Resolved
Install visual/audible high level alarm. LEGACY COMPONENT DESC: Alarms
Due 8 June 2001
Resolved 8 June 2001
Resolution: Temp
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 8 June 2001 Resolved
Repair/reinstall the correct cover to the 12 volt panel.
Due 8 June 2001
Resolved 8 June 2001
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 8 June 2001 Resolved
Install blanks for missing circuit breakers in 110 panel.
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline › Structures
Issued 8 June 2001 Resolved
Replace 4 damaged windows. LEGACY COMPONENT DESC: Windows
Due 8 June 2001
Resolved 8 June 2001
Engineering
Issued 8 June 2001 Resolved
Provide proof that AC unit is approved for marine use, and if so, properly install. LEGACY COMPONENT DESC: HVAC
Due 8 June 2001
Resolved 21 March 2002
Resolution: Received proper documentation indicating that the AC unit is foe marine use.
Engineering › Steering Gear System
Issued 8 June 2001 Resolved
Pilot [name withheld] - Remove duct tape from key to steering wheel. LEGACY COMPONENT DESC: Spline key
Due 8 June 2001
Resolved 8 June 2001
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 June 2001 Resolved
Mount junction box stbd side of wheel house.
Due 8 June 2001
Resolved 8 June 2001
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 June 2001 Resolved
Prove proper operation of engine start/stop. LEGACY COMPONENT DESC: Start/stop controlls
Due 8 June 2001
Resolved 8 June 2001
Accommodation/Occupational Safety
Issued 8 June 2001 Resolved
Properly install PA system. LEGACY COMPONENT DESC: Loud hailer/PA
Due 8 June 2001
Resolved 8 June 2001
Fire Fighting › Nozzles › Condition
Issued 8 June 2001 Resolved
Remove all suicide nozzles and replace with approved fire fighting nozzles.
Due 8 June 2001
Resolved 8 June 2001
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 June 2001 Resolved
Provide drug and alcohol employer policy, contract, proof of supervisor training, & proof of pre-employment drug testing.
Due 8 June 2001
Resolved 8 June 2001
Personnel › Certificates/Documents/Licenses
Issued 8 June 2001 Resolved
Provide Senior Deck hand letter of designation. LEGACY COMPONENT DESC: [name withheld], Chief Mate
Due 8 July 2001
Resolved 29 April 2002
Resolution: Vsl rep provided copy of Senior Deck Hand Letter of Designation.
Engineering › Fuel Oil Service System › Valve, Control
Issued 8 June 2001 Resolved
Mark remote fuel shutoff stations indicating purpose of the valves and direction of operations (at least 1" letters).
Due 8 June 2001
Resolved 8 June 2001
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 June 2001 Resolved
Renew temporary engine control/gauge wiring. LEGACY COMPONENT DESC: Controls/Gauges
Due 8 June 2001
Resolved 8 March 2002
Resolution: Engine control wiring renewed.
Electrical › Electric Supply System (service)
Issued 8 June 2001 Resolved
Renew temporary installation of battery for Navigation equipment located in engine room with proper installation in protected enclosure and wiring. LEGACY COMPONENT DESC: Battery Installation
Due 8 July 2001
Resolved 8 March 2002
Resolution: Navigational battery properly installed and protected.
Engineering
Issued 8 June 2001 Resolved
Renew missing bushings for mounts on A/C compressor. LEGACY COMPONENT DESC: HVAC
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline › Hull
Issued 8 June 2001 Resolved
Properly plug bulkhead penetrations in aft engine room bulkhead. LEGACY COMPONENT DESC: Watertight bulkhead penetrations
Due 8 June 2001
Resolved 8 March 2002
Resolution: Bulkhead plugged
Electrical › Electrical Distribution System (service)
Issued 8 June 2001 Resolved
Remove all "deadended" wiring in engine room. LEGACY COMPONENT DESC: Wiring
Due 8 June 2001
Resolved 8 March 2002
Resolution: Deadend wiring was removed
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 June 2001 Resolved
Make repairs to main power distribution panel in engine room. Examples: inoperable ground ammeter, bad rotary switch for generator #1 ammeter, broken light covers, etc
Due 8 June 2001
Resolved 8 June 2001
Electrical › Electrical Distribution System (service) › Switchboard
Issued 8 June 2001 Resolved
Provide a means of interlocking generator #1, generator #2 and shore power from feeding main distribution panel at the same time.
Due 8 June 2001
Resolved 8 June 2001
Fire Fighting › Structural - A Class Divisions
Issued 8 June 2001 Resolved
Renew missing structural fire protection insulation to A-60 standards where missing between engine room and accommodations space (main deck). Temporary repair in place. LEGACY COMPONENT DESC: Decks - Accommodation Spaces
Due 8 July 2001
Resolved 29 April 2002
Resolution: Vsl installed proper (A-60) insulation where missing.
Engineering › Bilge Water Management System
Issued 8 June 2001 Resolved
Prove proper operation of bilge de-watering system in forepeak & lazerette. LEGACY COMPONENT DESC: Operation
Due 8 June 2001
Resolved 8 June 2001
Electrical › Electric Generation Source (service)
Issued 8 June 2001 Resolved
The stbd generator is restricted from use (tag out/lock out) until proper operation is shown to attending USCG Marine Inspector. LEGACY COMPONENT DESC: Generator
Due 8 July 2001
Resolved 8 March 2002
Resolution: New Stbd generator installed.
Construction/Loadline › Hull
Issued 8 June 2001 Resolved
At next drydock crop and renew longitudinal stringers in aft port engine room on old sideshell #2 & 3 up from deck. LEGACY COMPONENT DESC: Stiffener
Due 30 June 2002
Resolved 29 April 2003
Construction/Loadline › Hull
Issued 8 June 2001 Resolved
At next drydock crop & renew improper clad welded area repairing severe pitting in hull at stbd side outboard of water tanks. Area to be determined. LEGACY COMPONENT DESC: Hull Plating
Due 30 June 2002
Resolved 28 April 2003
Fire Fighting
Issued 26 March 2001 Resolved
Provide fire doors at terminus of stairs on 01 deck and renew latches for engine room fire doors. See NVIC 9-97 for guidance.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Fire Fighting
Issued 26 March 2001 Resolved
Provide fireload calculations for new furnishings/trim on main and 01 decks.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Fire Fighting
Issued 26 March 2001 Resolved
Provide specifications for newly installed carpet, including flame spread rating.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Fire Fighting
Issued 26 March 2001 Resolved
Remove wood handrails from internal stairways and provide non-combustible handrails.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Lifesaving
Issued 26 March 2001 Resolved
Provide incline experiment procedure to USCG Marine Safety Center for approval. Upon approval, conduct incline experiment in presence of USCG Marine Inspectors.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Fire Fighting
Issued 26 March 2001 Resolved
Provide proper structural fire boundary of galley and passenger accommodation areas including fire doors. See NVIC 9-97 for guidance.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Documentation
Issued 26 March 2001 Resolved
Inspection for Certification to be conducted upon completion of above items.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Electrical
Issued 26 March 2001 Resolved
Provide plans for approval of electrical modifications on all decks - including one-line-diagram, load analysis: from source - new generators through new wiring & distribution panels, to loads and new equipment.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Fire Fighting
Issued 26 March 2001 Resolved
Provide plans for new fire extinguishing system and new galley equipment on02 deck.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Fire Fighting
Issued 26 March 2001 Resolved
Provide plans for installing fixed fire extinguishing fo proposed boiler insponson.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Construction/Loadline
Issued 26 March 2001 Resolved
Replace (weld) deck and framing previously removed for installation of dumbwaiter. (project has been cancelled.)
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Construction/Loadline
Issued 16 March 2000 Resolved
RENEW WASTED FRONT SUPPORT CLIP ON CINDER BLOCK BALLAST FRAMING LOCATED IN THE FOREPEAK.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Construction/Loadline
Issued 16 March 2000 Resolved
RENEW WASTED FORWARD MAIN DECK TONAGE DOOR FRAME.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Construction/Loadline
Issued 16 March 2000 Resolved
RENEW WASTED OVERHEAD PLATING IN WAY OF FORWARD COLLISION BLKHD IN CENTER- LINE VOID NO. 1.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Construction/Loadline
Issued 16 March 2000 Resolved
RENEW WASTED OVERHEAD PLATING IN WAY OF FORWARD COLLISION BLKHD IN PORT VOID #1.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Navigation
Issued 24 June 1998 Resolved
PROVIDE CURRENT GENERAL NAVIGATION PUBLICATIONS INCLUDING TIDE TABLES, CURRENT TABLES, RULES OF THE ROAD BOOK, COAST PILOT, AND LIGHT LIST._x001C_
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Lifesaving
Issued 24 June 1998 Resolved
PROVIDE ADEQUATE SEPARATION FOR ADULT AND CHILD LIFEJACKETS THROUGHOUT VESSEL.
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Construction/Loadline
Issued 24 June 1998 Resolved
REPAIR DECK HATCH SEALS FOR THE SECOND COMPARTMENT AFT AND THE LAZARETTE.
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Lifesaving
Issued 24 June 1998 Resolved
PASSENGER COUNT IS LIMITED TO 395 UNTIL FOUR ADDITIONAL APPROVED AND PROPERLY MARKED LIFEJACKETS ARE PROVIDED.
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Electrical
Issued 24 June 1998 Resolved
PROVIDE CIRCUIT BREAKER BLANK FOR PANEL BOX ON SECOND DECK BETWEEN STAIRWAYS.
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Lifesaving
Issued 24 June 1998 Resolved
REPLACE 60' LINE ON RING LIFE BUOY ON AFT OF PILOT HOUSE.
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Documentation
Issued 27 June 1997 Resolved
PROVIDE A METHOD OF RECOVERY FOR A M.O.B. AND CONDUCT EMERGENCY DRILLS IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 27 July 1997
Resolved 4 August 1997
Documentation
Issued 27 June 1997 Resolved
PROVE PROPER OPERATION OF THE DEPTH SOUNDER.
Condition: Unknown
Due 27 July 1997
Resolved 4 August 1997
Documentation
Issued 27 June 1997 Resolved
LABEL ELECTRICAL PANEL ON BRIDGE.
Condition: Unknown
Due 27 July 1997
Resolved 4 August 1997
Documentation
Issued 27 June 1997 Resolved
PROVIDE A 1996 EDITION OF 46 CFR SUBCHAPTER "K"
Condition: Unknown
Due 27 July 1997
Resolved 4 August 1997
Documentation
Issued 27 June 1997 Resolved
PROVE PROPER OPERATION OF OF #1 PACKAGE GEN SET.
Condition: Unknown
Due 27 July 1997
Resolved 4 August 1997
Documentation
Issued 27 June 1997 Resolved
PROVIDE PROPER COVERS FOR ALL ELECTRICAL BOXES IN THE ENGINE ROOM.
Condition: Unknown
Due 27 July 1997
Resolved 4 August 1997
Documentation
Issued 27 June 1997 Resolved
PROVE NAV LIGHTS MEET COLREG. REQUIREMENTS OR REPLACE WITH APPROVED KIND.
Condition: Unknown
Due 27 June 1997
Resolved 27 June 1997
Lifesaving
Issued 20 December 1995 Resolved
PROPERLY SECURE ALL GALLEY EQUIPMENT ON MAIN AND SECOND DECK.
Condition: Unknown
Due 20 January 1996
Resolved 24 January 1996
Electrical
Issued 20 December 1995 Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP ON PORT GENERATOR.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Fire Fighting
Issued 20 December 1995 Resolved
PROVIDE GAUGE POR NEWLY INSTALLED FIRE PUMP.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Construction/Loadline
Issued 20 December 1995 Resolved
CROP AND RENEW TO GOOD METAL 2ND DECK AFT IN WAY OF PREVIOUSLY INSTALLED DOUBLERS.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Electrical
Issued 10 October 1991 Resolved
INSTALL KNOBS NO. 2 GEN AMMETER/VOLTMETER
Condition: Unknown
Due 17 October 1991
Resolved 18 October 1991
Electrical
Issued 10 October 1991 Resolved
REPAIR 2ND DK EMERG. LIGHTS
Condition: Unknown
Due 17 October 1991
Resolved 18 October 1991
Electrical
Issued 10 October 1991 Resolved
REPAIR GEN. NO. 2 AMMETER.
Condition: Unknown
Due 17 October 1991
Resolved 18 October 1991
Fire Fighting
Issued 10 October 1991 Resolved
DEMONSTRATE GOPSI ELECT FIREPUMP OR REMOVE FROM FIREMAIN_x001C_ _x001C_
Condition: Unknown
Due 17 October 1991
Resolved 18 October 1991
Construction/Loadline
Issued 10 October 1991 Resolved
REPLACE SUCTION HOSE-ELECT. BILGE PUMP.
Condition: Unknown
Due 17 October 1991
Resolved 18 October 1991
Fire Fighting
Issued 10 October 1991 Resolved
REPAIR HOSE NOZZLE TO SHOW STRAIGHT STREAM._x001C_
Condition: Unknown
Due 17 October 1991
Resolved 18 October 1991
Lifesaving
Issued 10 October 1991 Resolved
PROVIDE 6 ADULT PFD'S(LIMITED TO 393 PASS UNTILL COMPLETE)
Condition: Unknown
Due 17 October 1991
Resolved 18 October 1991
Construction/Loadline
Issued 19 September 1991 Resolved
Install hose clamps as needed at bilge manifold prior to carrying passengers.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Construction/Loadline
Issued 19 September 1991 Resolved
Replace engine driven bilge pump outlet hose (top hose) prior to carrying passengers.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Construction/Loadline
Issued 19 September 1991 Resolved
Renew the drive belts for the engine driven bilge pump prior to carrying passengers.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Lifesaving
Issued 19 September 1991 Resolved
Clean oil and sludge from engine room bilges prior to carring passengers.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Construction/Loadline
Issued 19 September 1991 Resolved
Install new rungs to the forepeak access ladder prior to carrying passengers.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Lifesaving
Issued 19 September 1991 Resolved
Clean up the approximately 5 gallons of spilled liquid soap from the No. 2 Center compartment prior to carrying passengers.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Construction/Loadline
Issued 19 September 1991 Resolved
Install pipe bracket for bilge line in No. 2 Center compartment prior to carrying passengers.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Accommodation/Occupational Safety
Issued 19 September 1991 Resolved
Replace or frost the clear glass window in port aft toilet prior to carrying passengers.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Construction/Loadline
Issued 19 September 1991 Resolved
Renew gasket and wasted manhole landing to sewage compartment access prior to carrying passengers.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Accommodation/Occupational Safety
Issued 19 September 1991 Resolved
Repair leaks in the PVC piping at the forward bulkhead in the aft compartment prior to carrying passengers.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Fire Fighting
Issued 10 October 1990 Resolved
POST FIXED FIRE EXTINGUISHING SYSTEM INSTRUCTIONS OUTSIDE GALLEY ADJACENT TO DISCHARGE HANDLE AND AT FRYERS.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Electrical
Issued 10 October 1990 Resolved
REPAIR/CORRECT FOLLOWING ELECTRICAL ITEMS: A) REMOVE SJ CABLE BAND AREA. PROVIDE SUFFICIENT OUTLETS, HARD WIRED. B) REPAIR PORT DEEP FRYER OUTLET.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Construction/Loadline
Issued 10 October 1990 Resolved
MAKE PROPER DECK PENETRATIONS PORT MN DECK SEWAGE LINES AND SEAL UNUSED PENETRATION.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Lifesaving
Issued 10 October 1990 Resolved
PROVIDE 11 ADULT LIFE PRESERVERS. VESSEL RESTRICTED TO NO MORE THAN 390 PASSENGERS UNTIL PROVIDED.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Accommodation/Occupational Safety
Issued 10 October 1990 Resolved
OPEN AIR RECEIVER FOR INTERNAL EXAM.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Lifesaving
Issued 10 October 1990 Resolved
PROVIDE 6 ORANGE HAND DISTRESS FLARES.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Fire Fighting
Issued 10 October 1990 Resolved
PROVIDE ONE BII PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Navigation
Issued 10 October 1990 Resolved
INSTALL COTTER PIN AT CROSS BAR AT STBD STEERING GEAR.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Construction/Loadline
Issued 26 May 1990 Resolved
CREITED DRYDOCK DUE DUE 30NOV91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE.
Condition: Unknown
Due 26 May 1990
Resolved 26 May 1990
Accommodation/Occupational Safety
Issued 6 February 1990 Resolved
REMOVE ALL BOXES OF GLASSES AT DRYDOCK INSPECTION.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Accommodation/Occupational Safety
Issued 6 February 1990 Resolved
CLEAN SEWAGE TANK SPACE OF WATER AND SLUDGE.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Construction/Loadline
Issued 6 February 1990 Resolved
REPAIR LONGITUDINAL FRAME UNDER PORT RUDDER STOP.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Deck/Cargo
Issued 6 February 1990 Resolved
INSTALL BOLTS AND BACKING BARS ON P&S DECK PLATES TO COMPARTMENTS NEXT TO FUEL TANK.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Construction/Loadline
Issued 6 February 1990 Resolved
MAKE ALL MAIN DECK PENETRATIONS WATERTIGHT. (WHERE DRAIN HOSES LEAD TO SEWAGE TANK)
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Accommodation/Occupational Safety
Issued 17 October 1988 Resolved
RENEW GAUGE FOR AIR RECEIVER.
Condition: Unknown
Due 17 October 1988
Resolved 17 October 1988
Lifesaving
Issued 17 October 1988 Resolved
PROVIDE 76 ADULT AND 9 CHILD LIFE PRESERVERS. TOTAL PERSONS CARRIED ARE REDUCED BY THESE AMOUNTS UNTIL PROVIDED.
Condition: Unknown
Due 17 October 1988
Resolved 17 October 1988
Lifesaving
Issued 19 October 1987 Resolved
PROVIDE AN ADDITIONAL 26 ADULT LIFE PRESERVERS. PASSENGERS SHALL BE REDUCED BY 26 UNTIL COMPLETED.
Condition: Unknown
Due 19 October 1987
Resolved 19 October 1987
Lifesaving
Issued 19 October 1987 Resolved
REBUILD LIFE JACKET LOCKER STBD SIDE SECOND DECK.
Condition: Unknown
Due 19 October 1987
Resolved 19 October 1987
Fire Fighting
Issued 19 October 1987 Resolved
PROVIDE HAND PORTABLE FIRE PUMP.
Condition: Unknown
Due 19 October 1987
Resolved 19 October 1987
Construction/Loadline
Issued 19 October 1987 Resolved
MAKE MANHOLE COVER IN GALLEY DECK WATERTIGHT AND INSTALL SECURING DEVICE.
Condition: Unknown
Due 19 October 1987
Resolved 19 October 1987
Navigation
Issued 19 October 1987 Resolved
CLEAN OIL FROM BILGES IN STEERING GEAR COMPARTMENT.
Condition: Unknown
Due 19 October 1987
Resolved 19 October 1987
Deck/Cargo
Issued 19 October 1987 Resolved
CLEAN BILGES IN SEWAGE TANK COMPARTMENT.
Condition: Unknown
Due 19 October 1987
Resolved 19 October 1987
Accommodation/Occupational Safety
Issued 24 October 1985 Resolved
CLEAN UP STORE ROOM & REMOVE EXTRANEOUS PORTABLE EXTENSION CORDS.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Electrical
Issued 24 October 1985 Resolved
SUPPLY BATTERY BOX COVERS FOR GEN. START BATTERY BOXES.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Lifesaving
Issued 24 October 1985 Resolved
REPAIR THIRTY-ONE (31) ADULT & FOUR (4) CHILDS PFD'S.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Electrical
Issued 24 October 1985 Resolved
RESECURE OVERHEAD WIRING ON HURRICANE DECK CANOPY.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985

Casualty record · 2

4 July 2004Routine · role: Suspected to be in Violation of Law or Reg · serious marine incident, as classified · 1 injured · activity 2122252
26 January 2007Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2862698
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.