← All vessels
SUNSET QUEEN
SUNSET QUEEN is a 1973 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1984, most recently in July 2007, along with 220 deficiencies and 2 casualty investigations between 2004 and 2007.
Records from 1984 to 2007. Most recent: inspection, 9 July 2007.
- Built
- 1973
- Last inspected
- 9 July 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 220 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2004–2007
Identity
550882
WCZ7292
47651
Flag
UNITED STATES
367005720 (licence lapsed)
Maury page id
psix-47651
Inspections, by type
…with no type recorded13
Years with a record
24 calendar years (1984–2007)
The 72 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WCZ7292MMSI 367005720 · expired · compulsorily equipped · granted 28 March 2000, cancelled 29 May 2010
WCX7202MMSI not assigned · expired · compulsorily equipped · granted 4 September 1997, cancelled 10 November 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 72
9 July 2007
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2989068
27 March 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2896128
27 January 2007
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2863560
26 January 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2862698
25 October 2006
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2807917
21 April 2006
COI Inspection · MARPOL Annex V Examination · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2640508
8 September 2005
Deficiency Check · MTSA Verification · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2486919
8 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2385822
19 April 2005
Damage Survey · Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2337536
7 September 2004
Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2188854
27 July 2004
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2146389
13 July 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2131364
5 July 2004
Administrative Inspection · MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2122177
4 July 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2122252
4 July 2004
Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 2130845
8 September 2003
MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1899628
6 September 2002
Deficiency Check · Hull Examination · Administrative Inspection · Annual Inspection · Internal Structural Exam · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1680045
15 May 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1627329
29 April 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1611809
21 March 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1495812
8 June 2001
Inclining Experiment
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1063010
8 June 2001
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1373576
12 April 2001
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1062299
11 April 2001
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1062561
26 March 2001
Hull Examination · Construction Oversight
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1423551
9 March 2001
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1059723
28 February 2001
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058345
19 June 2000
Hull Examination · Construction Oversight
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1397546
18 April 2000
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051823
16 March 2000
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1424870
5 January 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 813484
30 September 1999
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1348029
24 August 1999
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1372733
5 August 1998
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 795710
24 June 1998
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1449074
31 January 1998
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1428915
23 December 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1117823
17 December 1997
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1111034
10 September 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1121610
20 August 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1119291
4 August 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1119531
27 June 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781195
17 January 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 878626
20 December 1995
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441004
16 December 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420894
14 December 1993
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1159600
18 November 1993
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 849315
2 March 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 665665
14 January 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1136304
15 October 1992
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 960067
15 October 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 960627
10 October 1991
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1251591
19 September 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 941754
28 November 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 919255
20 November 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214898
5 November 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 906492
10 October 1990
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1219489
26 May 1990
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1238701
6 February 1990
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1219552
13 October 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 897518
13 October 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227267
10 October 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227143
29 November 1988
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1207293
17 October 1988
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 887770
20 September 1988
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1193786
19 October 1987
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1023089
6 April 1987
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1022565
24 October 1986
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1325301
19 November 1985
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 993378
24 October 1985
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1301036
13 September 1985
Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1297607
25 October 1984
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 979020
Deficiency record · 220
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2006
Resolved
SECURE LIGHTING WIRE IN #2 VOID AS DISCUSSED WITH DECKHAND.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2006
Resolved
PUT SPLICE IN BOX IN HOLDING TANK SPACE.
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 April 2006
Resolved
REPAIR LEAKS ON POWER STEERING GEAR BOXES.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 21 April 2006
Resolved
DRY OUT BATTERY BOXES IN ENGINE ROOM
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 April 2006
Resolved
INSTALL EMERGENCY LIGHTING OVERHEAD OF BILGE MANIFOLD.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 21 April 2006
Resolved
INSTALL SEA RAILS ON ALL OPEN RANGE STOVES AND GRIDDLES.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 April 2006
Resolved
REMOVE SOFT PATCH AND INSTALL HARD PIPING ON COOLING WATER LINE ON STBD GENERATOR.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 21 April 2006
Resolved
REMOVE AND PROPERLY DISPOSE OF HYDRAULIC OIL IN ENGINE ROOM BILGE.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 April 2006
Resolved
REPAIR LEAK AND LOOSE FITTINGS ON WATER LINE OUTBOARD SIDE OF STDB ENGINE.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 21 April 2006
Resolved
ARRANGE EQUIPMENT AND TABLE IN LOWER GALLEY SO THAT FIRE DOOR HAS FREE MOVEMENT.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 21 April 2006
Resolved
REPAIR OIL FILTER LEAKS ON PORT ENGINE.
Engineering › Steering Gear System › Helix Shaft
Issued 21 April 2006
Resolved
TIGHTEN SHAFT PACKING ON BOTH SHAFTS.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 April 2006
Resolved
REPAIR VHF ANTENNA
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 April 2006
Resolved
RE - LABEL ELECTRICAL PANEL (BILGE ALARMS) ON BRIDGE.
Navigation › Collision/Grounding Avoidance › Radar
Issued 21 April 2006
Resolved
REPAIR INOPERABLE RADAR.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 April 2006
Resolved
UPDATE ALL NAVIGATION PUBS.
Electrical › Lighting (service) › Outlet Box
Issued 21 April 2006
Resolved
REPLACE LIGHTS ON BILGE HIGH LEVEL ALARM PANEL.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 April 2006
Resolved
UPDATE FIRST AID KIT.
Fire Fighting › Fire Pumps › Pressure
Issued 21 April 2006
Resolved
PROVE PROPER OPERATION OF POWER DRIVEN FIRE PUMP TO THE SAT OF THE ATTENDING CG MI.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 21 April 2006
Resolved
PROVIDE ADDITIONAL B-II CLASS EXTINGUISHER.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 September 2005
Resolved
Update the following navigation publications: US Coast Pilot, CG Light List, Tide Tables, and Current Tables.
Lifesaving › Hand Flares › Expired
Issued 8 September 2005
Resolved
Provide (3) red hand flares and (3) orange day smokes or proper substitution.
Documentation › Markings/Placards › Official Number (US)
Issued 8 September 2005
Resolved
Fill in Emergency Broadcast placard to make vessel specific.
Lifesaving › Lifefloat › Lifeline
Issued 8 September 2005
Resolved
Replace line on (5) waterlight lanyards on lifefloats as discussed with vsl rep.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 September 2005
Resolved
Update first aid kit (missing/expired meds).
Engineering › Bilge Water Management System › Not Operational
Issued 8 September 2005
Resolved
Repair visual indicator on bilge high level alarm panel.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 8 September 2005
Resolved
Tighten/replace shaft packing stbd. side.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 8 September 2005
Resolved
Install rubber mating on port and stbd side stairs leading into E/R IWO circuit panels.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 September 2005
Resolved
Permanently affix passenger lifejacket boxes.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 September 2005
Resolved
Properly affix PVC pipe in MSD void space. Remove wire from light fixture.
Documentation › Markings/Placards › Warning Signs
Issued 8 September 2005
Resolved
Properly label (placard) emergency exits (in the bow)
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 8 September 2005
Resolved
Properly post pax emergency evacuation plan.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 September 2005
Resolved
Properly adjust latch on stbd side fwd. door on third deck.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 September 2004
Resolved
Install proper size water light lanyard on port side top deck lifering bouy (3-6 ft is proper).
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 September 2004
Resolved
Clean out accumulated trash under galley stove and counters as needed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 September 2004
Resolved
Remove rusted drum of anti-freeze from aft starboard side deck.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 September 2004
Resolved
Conduct fire and man overboard drill prior to carrying passengers.
Stability › Watertight Integrity › Coaming
Issued 7 September 2004
Resolved
Make proper repairs to watertight door in engine room, prior to carrying passengers -chalk test-
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 September 2004
Resolved
Properly terminate pig tailed cord plugged in under deep fat fryer on top deck.
Engineering › Steering Gear System
Issued 8 September 2003
Resolved
Prover proper operation of Port Hydraulic steering pump. LEGACY COMPONENT DESC: Pump
Engineering › Bilge Water Management System
Issued 8 September 2003
Resolved
Prove proper operation of engine driven bilge pump installed on Stbd engine. LEGACY COMPONENT DESC: Pump
Navigation
Issued 8 September 2003
Resolved
Provide updated NavRules Publication 2D LEGACY COMPONENT DESC: Nav Rules Publication
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 September 2003
Resolved
Replace expired meds in first aid kit. LEGACY COMPONENT DESC: Meds
Engineering › Generator (propulsion-electric)
Issued 8 September 2003
Resolved
Install machinery guards on Port/Stbd diesel generators.
Engineering
Issued 8 September 2003
Resolved
Double hose clamp flex hose on stbd eng after coolers. LEGACY COMPONENT DESC: After cooler
Stability › Watertight Integrity
Issued 8 September 2003
Resolved
Properly seal wire penetration on fwd blkd in lazarette. LEGACY COMPONENT DESC: Lazarette (fwd blkhd)
Engineering › Shafting/Propeller Arrangements
Issued 8 September 2003
Resolved
Repack port engine shaft. Shaft leaking excessively. LEGACY COMPONENT DESC: Shaft log packing
Electrical
Issued 8 September 2003
Resolved
Pull out dead end wires penetrating E/R watertight bulkhead and permanently seal. LEGACY COMPONENT DESC: Dead end wires
Fire Fighting › Fire Pumps
Issued 8 September 2003
Resolved
Replace fire pump gauge - inop LEGACY COMPONENT DESC: Gauge
Electrical
Issued 8 September 2003
Resolved
Remove electrical surge protector from 2nd deck pantry. LEGACY COMPONENT DESC: surge protector
Electrical
Issued 8 September 2003
Resolved
Properly enclose electric control box for dishwasher 2nd deck (plastic housing cracked) LEGACY COMPONENT DESC: Dishwasher
Construction/Loadline
Issued 8 September 2003
Resolved
Replace window main deck aft stbd side. LEGACY COMPONENT DESC: Window
Electrical
Issued 8 September 2003
Resolved
Replace electrical box cover for A/C electric control in E/R. LEGACY COMPONENT DESC: AC Electrical Box
Engineering
Issued 8 September 2003
Resolved
Remount vent cover on side of main switchboard in E/R. LEGACY COMPONENT DESC: Vent cover
Stability › Watertight Integrity
Issued 8 September 2003
Resolved
Properly seal w/flange and plug overboard drain in transome. LEGACY COMPONENT DESC: Overboard drain
Electrical
Issued 8 September 2003
Resolved
Properly seal junction box above 3rd deck canopy IWO stern light. LEGACY COMPONENT DESC: Junction Box
Engineering › Bilge Water Management System
Issued 8 September 2003
Resolved
Replace collapsed flex hose on belt driven fire/bilge pump on Stbd engine. LEGACY COMPONENT DESC: Hose
Fire Fighting
Issued 8 September 2003
Resolved
Re-install all missing insulation on Port/Stbd engine room bulkheads. LEGACY COMPONENT DESC: Insulation
Electrical › Electrical Distribution System (service)
Issued 6 September 2002
Resolved
Remove or properly terminate dead ended wires beneath TV shelf in wheelhouse. LEGACY COMPONENT DESC: Wiring
Electrical › Electrical Distribution System (service)
Issued 6 September 2002
Resolved
Install cover to light switch cover in wheelhouse LEGACY COMPONENT DESC: Switch
Lifesaving › Lifejacket/PFD (General)
Issued 6 September 2002
Resolved
Place lifejacket donning placards on bulkheads & in conspicious locations for passengers to see
Construction/Loadline › Penetrations
Issued 6 September 2002
Resolved
Make fore & aft bulkhead penetrations in tank space watertight.
Documentation › Logs/Records
Issued 6 September 2002
Resolved
Provide training log and indicate date and general description of training given. LEGACY COMPONENT DESC: Logbook (official)
Navigation › Piloting/Steering
Issued 6 September 2002
Resolved
Provide U.S. Coast Pilot [name withheld] List, Tide Tables & Tidal Current Tables for vessel.
Documentation › Certificates/Documents
Issued 6 September 2002
Resolved
Provide copy of FCC Safety Certificate. LEGACY COMPONENT DESC: FCC SSL
Documentation › Certificates/Documents
Issued 6 September 2002
Resolved
Provide copy of Certificate Of Documentation LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Documentation › Markings/Placards
Issued 6 September 2002
Resolved
Provide Station Bill IAW 46 CFR 122.514
Operations/Management › Lifesaving
Issued 6 September 2002
Resolved
Make passenger count either verbally or in writing & available ashore.
Lifesaving › Rigid Liferafts
Issued 6 September 2002
Resolved
Renew retro-reflective tape to lifefloats as necessary. LEGACY COMPONENT DESC: Markings
Lifesaving › Lifebuoys
Issued 6 September 2002
Resolved
Replace unservicable lifebuoys (2)
Lifesaving › Lifejacket/PFD (General)
Issued 6 September 2002
Resolved
Re-label 1st deck lifejacket stowage to reflect actual numbers LEGACY COMPONENT DESC: Storage
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 September 2002
Resolved
Provide first aid kit which complies with contents of 46CFR160.041
Fire Fighting › Miscellaneous Items
Issued 6 September 2002
Resolved
Provide fire axe & mount in or near wheelhouse.
Fire Fighting › Fire Pumps
Issued 6 September 2002
Resolved
Prove proper operation of stbd fire pump (belt driven)
Engineering › Fuel Oil Service System › Vent Pipe
Issued 8 June 2001
Resolved
Main Deck - Renew stbd fuel vent flame screens w/ 30 x 30 mesh.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 8 June 2001
Resolved
Make permanent repairs to spliced shore tie cable.
Deck/Cargo
Issued 8 June 2001
Resolved
Make stage pivot pin secure @ both ends.
Deck/Cargo
Issued 8 June 2001
Resolved
Provide retention pins for boom pivot pin
Deck/Cargo
Issued 8 June 2001
Resolved
Permanently attach main deck ladder to main deck and 01 deck.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 June 2001
Resolved
Provide proper rails/courses/dodgers in railings on main deck.
Construction/Loadline › Structures › Manhole
Issued 8 June 2001
Resolved
Provide locking mechanism for fore peak hatch, clean gasket and connect retention chain.
Accommodation/Occupational Safety
Issued 8 June 2001
Resolved
01 Deck - Secure TVs.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 June 2001
Resolved
Install blanks for missing circuit breakers in electrical panel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 June 2001
Resolved
Remove unused phase wires in electrical panel.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 June 2001
Resolved
Provide proper rails/courses/dodgers in railings on 01 deck.
Accommodation/Occupational Safety
Issued 8 June 2001
Resolved
Secure ice machines.
Accommodation/Occupational Safety
Issued 8 June 2001
Resolved
Secure galley equipment.
Fire Fighting › Grease Extraction Hood
Issued 8 June 2001
Resolved
02 Deck - Move to safe location manual release for fixed fire fighting actuation LEGACY COMPONENT DESC: Fire Extinguishing manual release
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 June 2001
Resolved
Install cable grommet where passes through steel bulkhead under bar.
Fire Fighting › Structural Fire Protection - General › Column/Stanchion Construction
Issued 8 June 2001
Resolved
Remove wooden handrails in stair tower to 02 deck.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 June 2001
Resolved
Remove temporary work lights.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 June 2001
Resolved
Repair/replace/prove proper operation of Nav lights.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 8 June 2001
Resolved
Compartment #1 - Re-stuff all bulkhead penetrations (aft).
Accommodation/Occupational Safety › Occupational Safety
Issued 8 June 2001
Resolved
Remove construction debris. LEGACY COMPONENT DESC: Sanitary Conditions
Construction/Loadline › Hull
Issued 8 June 2001
Resolved
Reinstall lower vertical plate stiffeners in stbd void. LEGACY COMPONENT DESC: Side Shell
Engineering › Bilge Water Management System › Piping
Issued 8 June 2001
Resolved
Remove flexible connection for bilge suction (hard pipe).
Construction/Loadline › Hull
Issued 8 June 2001
Resolved
Remove unused copper lines and plug bulkhead in outboard voids. LEGACY COMPONENT DESC: Watertight bulkhead penetrations
Construction/Loadline › Hull
Issued 8 June 2001
Resolved
Compartment #3 - Stuff penetrations in fwd bulkhead. LEGACY COMPONENT DESC: Watertight bulkhead penetrations
Accommodation/Occupational Safety › Occupational Safety
Issued 8 June 2001
Resolved
Compartment #2 - Remove debris. LEGACY COMPONENT DESC: Sanitary conditions
Electrical › Lighting (service) › Lighting Fixture
Issued 8 June 2001
Resolved
Install globes and guards for light fixtures.
Engineering › Bilge Water Management System › Piping
Issued 8 June 2001
Resolved
Hard pipe bilge suction line in compartment 3.
Accommodation/Occupational Safety › Cooking Systems
Issued 8 June 2001
Resolved
Prep Area - Secure warmer. LEGACY COMPONENT DESC: Warmer
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 8 June 2001
Resolved
MSD Space - Provide pipe hangars for all PVC piping.
Engineering › Bilge Water Management System
Issued 8 June 2001
Resolved
Complete float switch installation for buoyancy compartment located below MSD space. LEGACY COMPONENT DESC: Alarm
Electrical › Electric Supply System (service)
Issued 8 June 2001
Resolved
Provide electrical cover for sewage pump. LEGACY COMPONENT DESC: Protection
Accommodation/Occupational Safety › Occupational Safety
Issued 8 June 2001
Resolved
Clean debris from bilge area. LEGACY COMPONENT DESC: Sanitary Conditions
Construction/Loadline › Hull
Issued 8 June 2001
Resolved
Cut and cap 3 unused pipes which terminate in MSD space. LEGACY COMPONENT DESC: Water tight bulkhead penetrations
Engineering › Fuel Oil Service System › Filter
Issued 8 June 2001
Resolved
Provide flame impingement bowls for fuel filters for main engines.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 8 June 2001
Resolved
Provide electrical cover for air pressure switch.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 8 June 2001
Resolved
Hydrostatically test air receiver in presence of Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 June 2001
Resolved
Install/replace lagging on both generators. LEGACY COMPONENT DESC: Exhaust lagging
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 June 2001
Resolved
Secure batteries - port/stbd.
Engineering › Diesel Engine (auxiliary)
Issued 8 June 2001
Resolved
Properly support generator water supply lines. LEGACY COMPONENT DESC: Cooling water line
Engineering › Diesel Engine (auxiliary)
Issued 8 June 2001
Resolved
Remove PVC piping from port generator water supply lines. LEGACY COMPONENT DESC: Cooling water line
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 June 2001
Resolved
Repair aft emergency light.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 June 2001
Resolved
Replace light globes and guards throughout engine room.
Fire Fighting › Fire Main
Issued 8 June 2001
Resolved
Remove flexible hose from bilge/fire system @ engine driven pump. LEGACY COMPONENT DESC: Piping
Accommodation/Occupational Safety › Occupational Safety
Issued 8 June 2001
Resolved
Pilot House - Properly install windshield wiper. LEGACY COMPONENT DESC: Windshield wiper
Accommodation/Occupational Safety
Issued 8 June 2001
Resolved
Properly install loud hailer. LEGACY COMPONENT DESC: Loud hailer
Communications › Audible Communications
Issued 8 June 2001
Resolved
Provide 300mm (11.8") bell. LEGACY COMPONENT DESC: Ships Bell
Engineering › Bilge Water Management System
Issued 8 June 2001
Resolved
Install visual/audible high level alarm. LEGACY COMPONENT DESC: Alarms
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 8 June 2001
Resolved
Repair/reinstall the correct cover to the 12 volt panel.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 8 June 2001
Resolved
Install blanks for missing circuit breakers in 110 panel.
Construction/Loadline › Structures
Issued 8 June 2001
Resolved
Replace 4 damaged windows. LEGACY COMPONENT DESC: Windows
Engineering
Issued 8 June 2001
Resolved
Provide proof that AC unit is approved for marine use, and if so, properly install. LEGACY COMPONENT DESC: HVAC
Engineering › Steering Gear System
Issued 8 June 2001
Resolved
Pilot [name withheld] - Remove duct tape from key to steering wheel. LEGACY COMPONENT DESC: Spline key
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 June 2001
Resolved
Mount junction box stbd side of wheel house.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 June 2001
Resolved
Prove proper operation of engine start/stop. LEGACY COMPONENT DESC: Start/stop controlls
Accommodation/Occupational Safety
Issued 8 June 2001
Resolved
Properly install PA system. LEGACY COMPONENT DESC: Loud hailer/PA
Fire Fighting › Nozzles › Condition
Issued 8 June 2001
Resolved
Remove all suicide nozzles and replace with approved fire fighting nozzles.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 June 2001
Resolved
Provide drug and alcohol employer policy, contract, proof of supervisor training, & proof of pre-employment drug testing.
Personnel › Certificates/Documents/Licenses
Issued 8 June 2001
Resolved
Provide Senior Deck hand letter of designation. LEGACY COMPONENT DESC: [name withheld], Chief Mate
Engineering › Fuel Oil Service System › Valve, Control
Issued 8 June 2001
Resolved
Mark remote fuel shutoff stations indicating purpose of the valves and direction of operations (at least 1" letters).
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 June 2001
Resolved
Renew temporary engine control/gauge wiring. LEGACY COMPONENT DESC: Controls/Gauges
Electrical › Electric Supply System (service)
Issued 8 June 2001
Resolved
Renew temporary installation of battery for Navigation equipment located in engine room with proper installation in protected enclosure and wiring. LEGACY COMPONENT DESC: Battery Installation
Engineering
Issued 8 June 2001
Resolved
Renew missing bushings for mounts on A/C compressor. LEGACY COMPONENT DESC: HVAC
Construction/Loadline › Hull
Issued 8 June 2001
Resolved
Properly plug bulkhead penetrations in aft engine room bulkhead. LEGACY COMPONENT DESC: Watertight bulkhead penetrations
Electrical › Electrical Distribution System (service)
Issued 8 June 2001
Resolved
Remove all "deadended" wiring in engine room. LEGACY COMPONENT DESC: Wiring
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 June 2001
Resolved
Make repairs to main power distribution panel in engine room. Examples: inoperable ground ammeter, bad rotary switch for generator #1 ammeter, broken light covers, etc
Electrical › Electrical Distribution System (service) › Switchboard
Issued 8 June 2001
Resolved
Provide a means of interlocking generator #1, generator #2 and shore power from feeding main distribution panel at the same time.
Fire Fighting › Structural - A Class Divisions
Issued 8 June 2001
Resolved
Renew missing structural fire protection insulation to A-60 standards where missing between engine room and accommodations space (main deck). Temporary repair in place. LEGACY COMPONENT DESC: Decks - Accommodation Spaces
Engineering › Bilge Water Management System
Issued 8 June 2001
Resolved
Prove proper operation of bilge de-watering system in forepeak & lazerette. LEGACY COMPONENT DESC: Operation
Electrical › Electric Generation Source (service)
Issued 8 June 2001
Resolved
The stbd generator is restricted from use (tag out/lock out) until proper operation is shown to attending USCG Marine Inspector. LEGACY COMPONENT DESC: Generator
Construction/Loadline › Hull
Issued 8 June 2001
Resolved
At next drydock crop and renew longitudinal stringers in aft port engine room on old sideshell #2 & 3 up from deck. LEGACY COMPONENT DESC: Stiffener
Construction/Loadline › Hull
Issued 8 June 2001
Resolved
At next drydock crop & renew improper clad welded area repairing severe pitting in hull at stbd side outboard of water tanks. Area to be determined. LEGACY COMPONENT DESC: Hull Plating
Fire Fighting
Issued 26 March 2001
Resolved
Provide fire doors at terminus of stairs on 01 deck and renew latches for engine room fire doors. See NVIC 9-97 for guidance.
Fire Fighting
Issued 26 March 2001
Resolved
Provide fireload calculations for new furnishings/trim on main and 01 decks.
Fire Fighting
Issued 26 March 2001
Resolved
Provide specifications for newly installed carpet, including flame spread rating.
Fire Fighting
Issued 26 March 2001
Resolved
Remove wood handrails from internal stairways and provide non-combustible handrails.
Lifesaving
Issued 26 March 2001
Resolved
Provide incline experiment procedure to USCG Marine Safety Center for approval. Upon approval, conduct incline experiment in presence of USCG Marine Inspectors.
Fire Fighting
Issued 26 March 2001
Resolved
Provide proper structural fire boundary of galley and passenger accommodation areas including fire doors. See NVIC 9-97 for guidance.
Documentation
Issued 26 March 2001
Resolved
Inspection for Certification to be conducted upon completion of above items.
Electrical
Issued 26 March 2001
Resolved
Provide plans for approval of electrical modifications on all decks - including one-line-diagram, load analysis: from source - new generators through new wiring & distribution panels, to loads and new equipment.
Fire Fighting
Issued 26 March 2001
Resolved
Provide plans for new fire extinguishing system and new galley equipment on02 deck.
Fire Fighting
Issued 26 March 2001
Resolved
Provide plans for installing fixed fire extinguishing fo proposed boiler insponson.
Construction/Loadline
Issued 26 March 2001
Resolved
Replace (weld) deck and framing previously removed for installation of dumbwaiter. (project has been cancelled.)
Construction/Loadline
Issued 16 March 2000
Resolved
RENEW WASTED FRONT SUPPORT CLIP ON CINDER BLOCK BALLAST FRAMING LOCATED IN THE FOREPEAK.
Construction/Loadline
Issued 16 March 2000
Resolved
RENEW WASTED FORWARD MAIN DECK TONAGE DOOR FRAME.
Construction/Loadline
Issued 16 March 2000
Resolved
RENEW WASTED OVERHEAD PLATING IN WAY OF FORWARD COLLISION BLKHD IN CENTER- LINE VOID NO. 1.
Construction/Loadline
Issued 16 March 2000
Resolved
RENEW WASTED OVERHEAD PLATING IN WAY OF FORWARD COLLISION BLKHD IN PORT VOID #1.
Navigation
Issued 24 June 1998
Resolved
PROVIDE CURRENT GENERAL NAVIGATION PUBLICATIONS INCLUDING TIDE TABLES, CURRENT TABLES, RULES OF THE ROAD BOOK, COAST PILOT, AND LIGHT LIST._x001C_
Lifesaving
Issued 24 June 1998
Resolved
PROVIDE ADEQUATE SEPARATION FOR ADULT AND CHILD LIFEJACKETS THROUGHOUT VESSEL.
Construction/Loadline
Issued 24 June 1998
Resolved
REPAIR DECK HATCH SEALS FOR THE SECOND COMPARTMENT AFT AND THE LAZARETTE.
Lifesaving
Issued 24 June 1998
Resolved
PASSENGER COUNT IS LIMITED TO 395 UNTIL FOUR ADDITIONAL APPROVED AND PROPERLY MARKED LIFEJACKETS ARE PROVIDED.
Electrical
Issued 24 June 1998
Resolved
PROVIDE CIRCUIT BREAKER BLANK FOR PANEL BOX ON SECOND DECK BETWEEN STAIRWAYS.
Lifesaving
Issued 24 June 1998
Resolved
REPLACE 60' LINE ON RING LIFE BUOY ON AFT OF PILOT HOUSE.
Documentation
Issued 27 June 1997
Resolved
PROVIDE A METHOD OF RECOVERY FOR A M.O.B. AND CONDUCT EMERGENCY DRILLS IN THE PRESENCE OF A MARINE INSPECTOR.
Documentation
Issued 27 June 1997
Resolved
PROVE PROPER OPERATION OF THE DEPTH SOUNDER.
Documentation
Issued 27 June 1997
Resolved
LABEL ELECTRICAL PANEL ON BRIDGE.
Documentation
Issued 27 June 1997
Resolved
PROVIDE A 1996 EDITION OF 46 CFR SUBCHAPTER "K"
Documentation
Issued 27 June 1997
Resolved
PROVE PROPER OPERATION OF OF #1 PACKAGE GEN SET.
Documentation
Issued 27 June 1997
Resolved
PROVIDE PROPER COVERS FOR ALL ELECTRICAL BOXES IN THE ENGINE ROOM.
Documentation
Issued 27 June 1997
Resolved
PROVE NAV LIGHTS MEET COLREG. REQUIREMENTS OR REPLACE WITH APPROVED KIND.
Lifesaving
Issued 20 December 1995
Resolved
PROPERLY SECURE ALL GALLEY EQUIPMENT ON MAIN AND SECOND DECK.
Electrical
Issued 20 December 1995
Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP ON PORT GENERATOR.
Fire Fighting
Issued 20 December 1995
Resolved
PROVIDE GAUGE POR NEWLY INSTALLED FIRE PUMP.
Construction/Loadline
Issued 20 December 1995
Resolved
CROP AND RENEW TO GOOD METAL 2ND DECK AFT IN WAY OF PREVIOUSLY INSTALLED DOUBLERS.
Electrical
Issued 10 October 1991
Resolved
INSTALL KNOBS NO. 2 GEN AMMETER/VOLTMETER
Electrical
Issued 10 October 1991
Resolved
REPAIR 2ND DK EMERG. LIGHTS
Electrical
Issued 10 October 1991
Resolved
REPAIR GEN. NO. 2 AMMETER.
Fire Fighting
Issued 10 October 1991
Resolved
DEMONSTRATE GOPSI ELECT FIREPUMP OR REMOVE FROM FIREMAIN_x001C_ _x001C_
Construction/Loadline
Issued 10 October 1991
Resolved
REPLACE SUCTION HOSE-ELECT. BILGE PUMP.
Fire Fighting
Issued 10 October 1991
Resolved
REPAIR HOSE NOZZLE TO SHOW STRAIGHT STREAM._x001C_
Lifesaving
Issued 10 October 1991
Resolved
PROVIDE 6 ADULT PFD'S(LIMITED TO 393 PASS UNTILL COMPLETE)
Construction/Loadline
Issued 19 September 1991
Resolved
Install hose clamps as needed at bilge manifold prior to carrying passengers.
Construction/Loadline
Issued 19 September 1991
Resolved
Replace engine driven bilge pump outlet hose (top hose) prior to carrying passengers.
Construction/Loadline
Issued 19 September 1991
Resolved
Renew the drive belts for the engine driven bilge pump prior to carrying passengers.
Lifesaving
Issued 19 September 1991
Resolved
Clean oil and sludge from engine room bilges prior to carring passengers.
Construction/Loadline
Issued 19 September 1991
Resolved
Install new rungs to the forepeak access ladder prior to carrying passengers.
Lifesaving
Issued 19 September 1991
Resolved
Clean up the approximately 5 gallons of spilled liquid soap from the No. 2 Center compartment prior to carrying passengers.
Construction/Loadline
Issued 19 September 1991
Resolved
Install pipe bracket for bilge line in No. 2 Center compartment prior to carrying passengers.
Accommodation/Occupational Safety
Issued 19 September 1991
Resolved
Replace or frost the clear glass window in port aft toilet prior to carrying passengers.
Construction/Loadline
Issued 19 September 1991
Resolved
Renew gasket and wasted manhole landing to sewage compartment access prior to carrying passengers.
Accommodation/Occupational Safety
Issued 19 September 1991
Resolved
Repair leaks in the PVC piping at the forward bulkhead in the aft compartment prior to carrying passengers.
Fire Fighting
Issued 10 October 1990
Resolved
POST FIXED FIRE EXTINGUISHING SYSTEM INSTRUCTIONS OUTSIDE GALLEY ADJACENT TO DISCHARGE HANDLE AND AT FRYERS.
Electrical
Issued 10 October 1990
Resolved
REPAIR/CORRECT FOLLOWING ELECTRICAL ITEMS: A) REMOVE SJ CABLE BAND AREA. PROVIDE SUFFICIENT OUTLETS, HARD WIRED. B) REPAIR PORT DEEP FRYER OUTLET.
Construction/Loadline
Issued 10 October 1990
Resolved
MAKE PROPER DECK PENETRATIONS PORT MN DECK SEWAGE LINES AND SEAL UNUSED PENETRATION.
Lifesaving
Issued 10 October 1990
Resolved
PROVIDE 11 ADULT LIFE PRESERVERS. VESSEL RESTRICTED TO NO MORE THAN 390 PASSENGERS UNTIL PROVIDED.
Accommodation/Occupational Safety
Issued 10 October 1990
Resolved
OPEN AIR RECEIVER FOR INTERNAL EXAM.
Lifesaving
Issued 10 October 1990
Resolved
PROVIDE 6 ORANGE HAND DISTRESS FLARES.
Fire Fighting
Issued 10 October 1990
Resolved
PROVIDE ONE BII PORTABLE FIRE EXTINGUISHER.
Navigation
Issued 10 October 1990
Resolved
INSTALL COTTER PIN AT CROSS BAR AT STBD STEERING GEAR.
Construction/Loadline
Issued 26 May 1990
Resolved
CREITED DRYDOCK DUE DUE 30NOV91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE.
Accommodation/Occupational Safety
Issued 6 February 1990
Resolved
REMOVE ALL BOXES OF GLASSES AT DRYDOCK INSPECTION.
Accommodation/Occupational Safety
Issued 6 February 1990
Resolved
CLEAN SEWAGE TANK SPACE OF WATER AND SLUDGE.
Construction/Loadline
Issued 6 February 1990
Resolved
REPAIR LONGITUDINAL FRAME UNDER PORT RUDDER STOP.
Deck/Cargo
Issued 6 February 1990
Resolved
INSTALL BOLTS AND BACKING BARS ON P&S DECK PLATES TO COMPARTMENTS NEXT TO FUEL TANK.
Construction/Loadline
Issued 6 February 1990
Resolved
MAKE ALL MAIN DECK PENETRATIONS WATERTIGHT. (WHERE DRAIN HOSES LEAD TO SEWAGE TANK)
Accommodation/Occupational Safety
Issued 17 October 1988
Resolved
RENEW GAUGE FOR AIR RECEIVER.
Lifesaving
Issued 17 October 1988
Resolved
PROVIDE 76 ADULT AND 9 CHILD LIFE PRESERVERS. TOTAL PERSONS CARRIED ARE REDUCED BY THESE AMOUNTS UNTIL PROVIDED.
Lifesaving
Issued 19 October 1987
Resolved
PROVIDE AN ADDITIONAL 26 ADULT LIFE PRESERVERS. PASSENGERS SHALL BE REDUCED BY 26 UNTIL COMPLETED.
Lifesaving
Issued 19 October 1987
Resolved
REBUILD LIFE JACKET LOCKER STBD SIDE SECOND DECK.
Fire Fighting
Issued 19 October 1987
Resolved
PROVIDE HAND PORTABLE FIRE PUMP.
Construction/Loadline
Issued 19 October 1987
Resolved
MAKE MANHOLE COVER IN GALLEY DECK WATERTIGHT AND INSTALL SECURING DEVICE.
Navigation
Issued 19 October 1987
Resolved
CLEAN OIL FROM BILGES IN STEERING GEAR COMPARTMENT.
Deck/Cargo
Issued 19 October 1987
Resolved
CLEAN BILGES IN SEWAGE TANK COMPARTMENT.
Accommodation/Occupational Safety
Issued 24 October 1985
Resolved
CLEAN UP STORE ROOM & REMOVE EXTRANEOUS PORTABLE EXTENSION CORDS.
Electrical
Issued 24 October 1985
Resolved
SUPPLY BATTERY BOX COVERS FOR GEN. START BATTERY BOXES.
Lifesaving
Issued 24 October 1985
Resolved
REPAIR THIRTY-ONE (31) ADULT & FOUR (4) CHILDS PFD'S.
Electrical
Issued 24 October 1985
Resolved
RESECURE OVERHEAD WIRING ON HURRICANE DECK CANOPY.
Casualty record · 2
4 July 2004Routine · role: Suspected to be in Violation of Law or Reg · serious marine incident, as classified · 1 injured · activity 2122252
26 January 2007Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2862698
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.