Records from 1981 to 2023. Most recent: inspection, 25 September 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 58
25 September 2023
Load Line/Change of Employment · Exemption
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7799265
20 May 2008
Hull Examination · Internal Structural Exam · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3211931
14 November 2007
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3097579
26 April 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2634071
10 January 2006
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2564047
17 May 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2360783
12 May 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2356220
16 April 2005
Periodic Inspection · MTSA/ISPS Verification · Deficiency Check · Ballast Water Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2333867
1 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2324553
14 December 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2259351
3 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087493
28 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995596
22 September 2003
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1908139
21 January 2003
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1733033
25 March 2002
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1495894
18 March 2002
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1494570
25 January 2002
Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1477934
9 January 2002
Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1495462
14 June 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1454963
5 September 2000
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 822868
7 September 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 779142
26 August 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 182788
30 June 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1466626
29 December 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 808767
5 November 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 785757
30 September 1997
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1406212
20 September 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409563
26 August 1996
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407696
26 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454362
20 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392487
20 May 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466422
13 May 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430200
25 July 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1461586
6 April 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 101466
13 December 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463803
29 October 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1258961
10 December 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 945701
16 September 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1310698
12 September 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1245596
18 May 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936260
3 May 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312797
15 October 1990
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1226295
12 September 1990
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1223434
22 August 1990
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 904506
3 May 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1037998
17 March 1988
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1039198
22 June 1987
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1311461
19 May 1987
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1013638
11 November 1986
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1015267
27 June 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 987669
16 October 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 979002
4 September 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1282475
25 July 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974476
17 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275574
29 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965196
27 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971789
6 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963345
20 July 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279227
Engineering › Fuel Oil Service System › Valve, Control
Issued 16 July 2008
Resolved
WHILE IN TRANSIT THE VESSEL MUST KEEP ALL SUCTION VLVS FOR THE #6 P & S FUEL TKS CLOSED WITH THE EXCEPTION OF THE LOW SUCTION VALVE FOR #6 PORT. THE WATERTIGHT DOOR TO SHAFT ALLEY MUST REMAIN CLOSED AT ALL TIMES WHILE UNDERWAY. ALL VALVES MUST BE REPAIRED AND TESTED PRIOR TO BEING ACTIVATED. IF ACTIVATED THE ABOVE MEASURES MUST BE FOLLOWED.
Action required: 705 - Other - as specified
Resolved 29 April 2010
Resolution: Hydraulic emergency shut downs on fuel valves installed and tested.
Engineering › Pressure Vessel › Shell Plate
Issued 16 July 2008
Resolved
ALL PRESSURE VESSELS LISTED ON THE COI MUST BE INSPECTED BY CG MARINE INSPECTOR PRIOR TO ACTIVATION.
Action required: 705 - Other - as specified
Resolved 24 April 2010
Resolution: All pressure vessels listed on the COI have been inspected and found in satisfactory condition.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 July 2008
Resolved
REPLACE/REPAIR NAVIGATION LIGHT FOUNDATIONS FOR THE P & S RUNNING LIGHTS PRIOR TO ACTIVATION.
Action required: 705 - Other - as specified
Resolved 28 April 2010
Resolution: Inspected navigation light foundations; found satisfactory.
Deck/Cargo › Cargo Stowage › General
Issued 16 July 2008
Resolved
PROVE PROPER OPERATION OF CARGO HOLD SPRINKLER SYSTEMS PRIOR TO ACTIVATION.
Action required: 705 - Other - as specified
Resolved 28 April 2010
Resolution: Witnessed operation of cargo hold sprinker system in each cargo hold. All satisfactory.
Engineering › Steam Boiler (propulsion) › Surface Blow Pipe
Issued 16 July 2008
Resolved
MAKE PERMENANT REPAIRS TO STBD SUPERHEATER DRAIN LINE IWO JUBILEE CLAMP PRIOR TO ACTIVATION.
Action required: 705 - Other - as specified
Resolved 24 April 2010
Resolution: Examined stbd superheater drain line; found satisfactory.
Engineering › Steam System (main) › Piping
Issued 23 April 2005
Resolved
Calibrate gauges on steam system.
Action required: 705 - Other - as specified
Due 23 June 2005
Resolved 12 May 2005
Resolution: All gauges calibrated.
Engineering › Steam Boiler (propulsion) › Shell
Issued 3 October 2003
Resolved
CG 835: Complete hydrostatic test of both boilers prrior to operation.
Action required: 705 - Other - as specified
Resolved 23 April 2005
Resolution: Completed hydrostatic test of boilers on 17 APR 2005.
Engineering › Pressure Vessel › Relief Valve
Issued 22 September 2003
Resolved
Demonstrate proper operation of all safety relief devices on all pressure vessels.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Pressure vessel safety relief devices tested satisfactory.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 22 September 2003
Resolved
Fix all ground indicators on all ship service main switchboard.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Repaired all ground indicators.
Electrical › Lighting (emergency) › Outlet Box
Issued 22 September 2003
Resolved
Replace all junction box covers throughout the ship.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Junction box covers replaced or repaired.
Electrical › Electric Supply System (service) › Cable
Issued 22 September 2003
Resolved
Remove wiring tie wrap to CO2 discharge line on upper level engine room flat.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Removed wiring tie wraps.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 22 September 2003
Resolved
Remove all water from deck in battery locker.
Due 22 October 2003
Resolved 23 April 2005
Resolution: All water removed from deck in battery locker.
Construction/Loadline › Structures › Door
Issued 22 September 2003
Resolved
Repair all door closures throughout the vessel.
Due 22 October 2003
Resolved 23 April 2005
Resolution: All door closures repaired.
Electrical › Electric Generation Source (service) › Panelboard
Issued 22 September 2003
Resolved
Repair chafed wire and strap in bundle under panel for the boiler.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Repaired chafed wire.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 22 September 2003
Resolved
Install blanks in open breakers in box 2-53-1 LEGACY COMPONENT DESC: Circuit Breaker
Due 22 October 2003
Resolved 23 April 2005
Resolution: Blanks installed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 September 2003
Resolved
Label escape hatches in EDG room.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Labeled escape hatches.
Deck/Cargo › Ballast › Valves
Issued 22 September 2003
Resolved
Properly label all valves on ballast control mainfold.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Labeled valves on ballast control manifold.
Engineering › Steam Turbine (auxiliary) › Valve, Regulating
Issued 22 September 2003
Resolved
Replace lube oil cooler gauge on steam turbine generator.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Replaced lube oil cooler gauge on steam turbine generator.
Engineering › Steam Turbine (auxiliary) › Valve, Regulating
Issued 22 September 2003
Resolved
Replace aft bearing oil test gauge on steam turbine generator.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Replaced aft bearing oil test gauge on steam turbine generator.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 22 September 2003
Resolved
Replace door on breaker panel 2-80-1.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Door replaced.
Construction/Loadline › Structures › Door
Issued 22 September 2003
Resolved
Repair handrails throughout main deck.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Handrails repaired throughout
Electrical › Electric Generation Source (emergency) › Ground Detection
Issued 22 September 2003
Resolved
Repair test ground lights in EDG room breaker panel labelled "aft emergency 120V load center" and "emergency 24V DC load center."
Due 22 October 2003
Resolved 23 April 2005
Resolution: Ground lights repaired.
Construction/Loadline › Structures › Superstructure
Issued 22 September 2003
Resolved
Make permanent repairs to hole in bulkhead near #19 fire station.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Repaired hole in bulkhead.
Electrical › Electric Supply System (service) › Cable
Issued 22 September 2003
Resolved
Replace plastic wire ties throughout vessel with proper wire ties.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Wire ties replaced.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 22 September 2003
Resolved
Properly label breaker box 01-48-2.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Breaker box labeled properly.
Stability › Weathertight Integrity › General
Issued 22 September 2003
Resolved
Replace gaskets on doors & vents throughout the vessel. Weather decks missing most. Conduct chalk test. Gasket material on site and contractors currently working on vessel.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Replaced gaskets on doors and vents. Chalk tested satisfactory.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 22 September 2003
Resolved
Throughout accomodations, repair inoperable toilets.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Repaired or replaced inoperable toilets.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 22 September 2003
Resolved
Repair freezer alarms. Plunger is operable; however installed alarms do not function.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Alarms all tested satisfactory.
Stability › Weathertight Integrity › General
Issued 22 September 2003
Resolved
Repair window on bridge. Make weathertight.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Window replaced.
Lifesaving › Lifeboat › Hull
Issued 22 September 2003
Resolved
Repair aft keel block on stbd lifeboat.
Due 22 October 2003
Resolved 23 April 2005
Resolution: AFT KEEL BLOCK REPAIRED.
Fire Fighting › Fire Hydrants › Condition
Issued 22 September 2003
Resolved
Repair door to fire station # 21 (tied shut)
Due 22 October 2003
Resolved 23 April 2005
Resolution: FIRE STATION #21 DOOR REPAIRED.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 September 2003
Resolved
Repair e-light bracket near hold #6 and #7 port.
Due 22 October 2003
Resolved 23 April 2005
Resolution: Repaired E-light bracket.
Fire Fighting › Fire Hydrants › Condition
Issued 22 September 2003
Resolved
Repair door to Fire Station 21
Action required: 705 - Other - as specified
Resolved 23 April 2005
Resolution: FIRE STATION 21 DOOR REPAIRED.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 September 2003
Resolved
Repair E-Light bracket near holds #6, #7 port.
Action required: 705 - Other - as specified
Resolved 23 April 2005
Resolution: Rapaired E-light bracket.
Lifesaving › Launching Appliances › Falls
Issued 25 January 2002
Resolved
Install both boat falls IAW 46 CFR 199.153(b) and test to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Falls
Action required: 705 - Other - as specified
Due 11 March 2002
Resolved 23 April 2005
Resolution: FALLS RENEWED AND WEIGHT TESTED 22 SEP 2003.
Electrical › Lighting (service)
Issued 25 January 2002
Resolved
Make proper repairs to all non-working lights in the cargo holds. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2002
Resolved 25 March 2002
Resolution: Affected sockets renewed.
Engineering › Steam Turbine (propulsion)
Issued 25 January 2002
Resolved
Prove proper operation of the throttle valve 'O' position (throttle will not return to neutral). LEGACY COMPONENT DESC: Valve, Throttle
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 February 2002
Resolved 25 March 2002
Resolution: Witnessed proper operation.
Engineering › Sea-water System (primary cooling)
Issued 25 January 2002
Resolved
Make proper repairs on the lube oil cooler upper salt water outlet valve, number 1440. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 February 2002
Resolved 25 March 2002
Electrical › Electrical Distribution System (service)
Issued 25 January 2002
Resolved
Permanently attach electrical outlet IWO lube oil cooler upper salt water outlet. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2002
Resolved 25 March 2002
Resolution: Item removed from ship.
Fire Fighting › Fire Main
Issued 25 January 2002
Resolved
Provide gauges for fire pump and bilge suction. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2002
Resolved 25 March 2002
Resolution: New gauges installed.
Engineering › Steam Boiler (propulsion)
Issued 25 January 2002
Resolved
Prove proper operation of alarm for engine order telegraph wrong way alarm.
Action required: 705 - Other - as specified
Due 24 February 2002
Resolved 25 March 2002
Resolution: Witnessed proper operation.
Engineering › Steam Turbine (propulsion)
Issued 25 January 2002
Resolved
Conduct test of L.P. and H.P. turbine ahead and astern overspeeds.
Action required: 705 - Other - as specified
Due 24 February 2002
Resolved 25 March 2002
Engineering › Steam System (main)
Issued 25 January 2002
Resolved
Properly install astern throttle manual override valve locking device. LEGACY COMPONENT DESC: Valve, Control
Action required: 705 - Other - as specified
Due 24 February 2002
Resolved 25 March 2002
Resolution: Locking device installed.
Stability › Incline Test
Issued 25 January 2002
Resolved
Vessel is not to load cargo until the vessel's stability book is updated and approved by the Coast Guard Marine Safety Center.
Action required: 705 - Other - as specified
Due 24 February 2002
Resolved 18 March 2002
Resolution: Received approval letter and copy of new Stability Letter from MSC.
Engineering
Issued 30 June 1999
Resolved
PROVIDE TO [name withheld] ENGINEER DETAILING OPERATION/TEST OF MAINTURBINE OVERSPEED TRIP.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Unknown
Issued 30 June 1999
Resolved
RENEW VALVE HANDLE AT L/O TRANSFER PUMP OUTBOARD.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Electrical
Issued 30 June 1999
Resolved
REPAIR LEAK AT RAW WATER PUMP ON DIESEL GENERATOR.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Accommodation/Occupational Safety
Issued 30 June 1999
Resolved
PROVE PROPER OPERATION OF SEWAGE TREATMENT SYSTEM.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Engineering
Issued 30 June 1999
Resolved
REPAIR WASTED PIPE AT MAIN CIRC. PUMP, 3/4" LINE INBOARD SIDE.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Engineering
Issued 30 June 1999
Resolved
RENEW/REPAIR DEFECTIVE GAUGES IN BOILER/MACHINERY SPACE.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Electrical
Issued 30 June 1999
Resolved
REPAIR OIL LEAK AT DIESEL GENERATOR L/O LINE TO FILTER BANK.
Condition: Unknown
Due 2 July 1999
Resolved 6 July 1999
Unknown
Issued 30 June 1999
Resolved
MAKE PERMANENT REPAIRS TO 4" EVAP RAW WATER SUPPLY LINE.
Condition: Unknown
Due 30 June 1999
Resolved 6 July 1999
Electrical
Issued 30 June 1999
Resolved
REPAIR AND PROVE OPERATION OF PORT CONDENSATE PUMP/MOTOR.
Condition: Unknown
Due 2 July 1999
Resolved 6 July 1999
Engineering
Issued 30 June 1999
Resolved
REPAIR AND PROVE PROPER OPERATION OF LEVEL INDICATING DEVICE ON EMERG. GEN.F/O TANK, KING GAUGE.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Fire Fighting
Issued 30 June 1999
Resolved
REPAIR LEAKING FIREMAIN VALVE IN HALLWAY OUTSIDE OF STEERING GEAR ROOM ON PORT SIDE.
Condition: Unknown
Due 2 July 1999
Resolved 6 July 1999
Engineering
Issued 30 June 1999
Resolved
RENEW/REPAIR PORT FORCED DRAFT FAN FAILURE INDICATOR LIGHT.
Condition: Unknown
Due 2 July 1999
Resolved 6 July 1999
Engineering
Issued 30 June 1999
Resolved
REPACK MAIN CIRC. PUMP PACKING GLAND.
Condition: Unknown
Due 2 July 1999
Resolved 6 July 1999
Engineering
Issued 30 June 1999
Resolved
REPAIR AND PROVE OPERATION OF REMOTE D.C. WATER LEVEL INDICATING METER.
Condition: Unknown
Due 2 July 1999
Resolved 6 July 1999
Navigation
Issued 30 June 1999
Resolved
PROVE PROPER OPERATION OF LOSS OF POWER ALARM FOR STEERING GEAR.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Navigation
Issued 30 June 1999
Resolved
REPAIR MINOR HYDRAULIC LEAK ON STEERING SYSTEM.
Condition: Unknown
Due 2 July 1999
Resolved 6 July 1999
Electrical
Issued 30 September 1997
Resolved
REPAIR/REPLACE LUBE OIL ALARM AND SHUTDOWN ON DIESEL GENERATOR.
Condition: Unknown
Due 30 September 1997
Resolved 18 November 1997
Fire Fighting
Issued 30 September 1997
Resolved
EFFECT REPAIRS TO LEAKING Y-GATE F/S #8.
Condition: Unknown
Due 30 September 1997
Resolved 18 November 1997
Construction/Loadline
Issued 30 September 1997
Resolved
CHECK, REPLACE, AND/OR REPAIR OPERATION AND GASKETS OF ALL WATERTIGHT DOORS.
Condition: Unknown
Due 5 November 1997
Resolved 18 November 1997
Engineering
Issued 30 September 1997
Resolved
RENEW PLUG TO FUEL OIL CONTAINMENT AFT OF HOUSE.
Condition: Unknown
Due 5 November 1997
Resolved 18 November 1997
Fire Fighting
Issued 30 September 1997
Resolved
REPLACE/REPAIR NOZZLES AT #14, 17, 19, AND 22 FIRE STATIONS.
Condition: Unknown
Due 3 October 1997
Resolved 18 November 1997
Navigation
Issued 30 September 1997
Resolved
POST EMERGENCY STEERING DIAGRAM/ INSTRUCTIONS ON BRIDGE.
Condition: Unknown
Due 5 November 1997
Resolved 18 November 1997
Engineering
Issued 13 May 1996
Resolved
RE-WRITE VESSEL OPERATING PROCEDURE 2.8.8 PARA. 1 TO REMOVE THE USAE OF A GARDEN HOSE FOR FUEL OIL TRANSFERS.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Construction/Loadline
Issued 13 May 1996
Resolved
MAKE REPAIRS TO HINGE ON EXTERIOR WTD - UPPER DECK - STB SIDE.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Electrical
Issued 13 May 1996
Resolved
INSTALL HAND RAIL ON MAIN ELEC. DISTRIBUTION BOARD IN VICINITY OF SHORE TIEBREAKER._x001C_
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Lifesaving
Issued 13 May 1996
Resolved
PROVIDE HAMMER FOR PORT EMERGENCY SHUT DOWN PANEL OUTSIDE OF PORT ENG. ROOMACCESS.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Engineering
Issued 13 May 1996
Resolved
RE-WRITE AUTOMATION TEST PROCEDURES "II,C" TO REMOVE AUDIBLE REFERENCE, ALARM IS VISUAL ONLY.
Condition: Unknown
Due 13 June 1996
Resolved 26 June 1996
Electrical
Issued 13 May 1996
Resolved
LOCATE AND CORRECT CAUSE OF GROUNDS THROUGHOUT SHIP'S ELECTRICAL DISTRIBUTION SYSTEM.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Fire Fighting
Issued 13 May 1996
Resolved
PROVE PROPER OPERATION OF AUTOMATIC CO2 DAMPER IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Fire Fighting
Issued 13 May 1996
Resolved
OBTAIN APPROVAL FOR SMOKE DETECTING SYSTEM ALTERATION FROM THE U.S. COAST GUARD MARINE SAFETY CENTER AS PER 46 CFR 91.55-10.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Lifesaving
Issued 13 May 1996
Resolved
CONDUCT WEIGHT TEST ON PORT AND STB (BOTH) LIFEBOATS, AND LOWER STB EMBARKATION LADDER FOR INSPECTION.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Lifesaving
Issued 25 July 1994
Resolved
PRIOR TO ACTIVATION PROVIDE INVOICE & LETTER TO OCMI THAT CONDEMNED 15- PERSON LIFERAFT HAS BEEN REPLACED WITH ANOTHER SATISFACTORY LIFERAFT.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Lifesaving
Issued 25 July 1994
Resolved
PRIOR TO ACTIVATION DEMONSTRATE TO ATTENDING CG INSPECTOR SUFFICIENT & UPDATED LIFEBOAT EQUIPMENT FOR BOTH LIFEBOATS.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Documentation
Issued 25 July 1994
Resolved
PRIOR TO ACTIVATION PROVIDE EVIDENCE OF VALID FCC CERTIFICATE TO THE COGNIZANT OCMI.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Lifesaving
Issued 25 July 1994
Resolved
PRIOR TO ACTIVATION PROVIDE FOR ATTENDING CG INSPECTOR UPDATED NAVIGATION PUBLICATIONS, BRIDGE PYROTECHNIC DEVICES, & HOSPITAL SUPPLIES.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Engineering
Issued 25 July 1994
Resolved
COMPLETE AN OVERSPEED TRIP TEST ON THE MAIN ENGINES AND LOG THE TIME, DATE AND LOCATION OF TEST DONE IN SHIP'S LOG BOOK
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Lifesaving
Issued 29 October 1992
Resolved
CONDUCT FIRE AND BOAT DRILL
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Engineering
Issued 3 May 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF ENGINE BEARING MONITOR SENSORS NUMBER ONE AND THREE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Engineering
Issued 3 May 1991
Resolved
PROVE PROPER OPERATION OF ALL VISIBLE ENGINE ROOM CONSOLE ALARMS.
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Navigation
Issued 3 May 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF NAVIGATION LIGHT FUSE PANEL ALARM FOR STERN LIGHT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Accommodation/Occupational Safety
Issued 3 May 1991
Resolved
REMOVE TEMPORARY PATCH AND MAKE PERMANENT REPAIRS TO MARINE SANITATION DEVICE TANK. ALL PERMANENT REPAIRS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Engineering
Issued 3 May 1991
Resolved
REPLACE IMPROPER SAFETY RELIEF VALVE FOR POTABLE HOT WATER HEATER (PRESSUREVESSEL #72087) WITH APPROVED 100 POUND SAFETY RELIEF VALVE.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Engineering
Issued 3 May 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF CONSOLE STARBOARD BOILER LEVEL INDICATOR IN ENGINE ROOM (LOW-LOW WATER) TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Navigation
Issued 3 May 1991
Resolved
REMOVE TEMPORARY PATCH AND MAKE PERMANENT REPAIRS TO THE PORT STEERING MOTOR HYDRAULIC OIL TANK. ALL PERMANENT REPAIRS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Electrical
Issued 3 May 1991
Resolved
REPLACE CRACKED FLEXIBLE JOINT CONNECTION TO SHIP'S SERVICE GENERATOR.
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Navigation
Issued 3 May 1991
Resolved
RENEW MAIN RUDDER SHAFT SEALS AT NEXT DYRDOCK AND IN NO CASE LATER THAN 30 SEPTEMBER 1991. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Lifesaving
Issued 3 May 1991
Resolved
PROVIDE TWO BUOYANT PROJECTILES FOR KILGORE LINE THROWING GUN.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Construction/Loadline
Issued 3 May 1991
Resolved
REPAINT DRAFT MARKS PORT AND STARBOARD TO RENDER THEM EASILY LEGIBLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Lifesaving
Issued 3 May 1991
Resolved
REPAIR OR REPLACE PORT MOTOR LIFEBOAT ENGINE, AND PROVE PROPER OPERATION THREREOF TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO DEPARTING THE PORT OF LIVORNO, ITALY AND IN NO CASE LATER THAN 20 MAY 1991.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Navigation
Issued 3 May 1991
Resolved
REPAIR OR REPLACE MODIFIED NAVIGATION FIXTURES AS ORIGINAL CONDITION AND REPLACE BULBS WITH APPROVED VERTICLE FILAMENT BULBS.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Construction/Loadline
Issued 3 May 1991
Resolved
DESCALE, CLEAN, GAUGE, AND PROVIDE REPORT ON THICKNESS OF STRUCTURAL MEMBERS FOR AFTER PEAK PORT AND STARBOARD, WITH ORIGINAL SCANTLINGS AND ORIGINAL THICKNESS READINGS AT NEXT DRYDOCK AND IN NO CASE LATER THAN 30 SEPTEMBER 1991.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Deck/Cargo
Issued 3 May 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF ALL DECK CARGO CRANE WARNING SIRENS AND LIGHTS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Engineering
Issued 22 August 1990
Resolved
DEMONSTRATE OPERATION OF OILY WATER SEPERATOR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
DEMONSTRATE PROPER OPERATION OF AUTOMATIC LOAD TRANSFER TO THE EMERGENCY GENERATOR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Documentation
Issued 22 August 1990
Resolved
SUBMIT AN APPROVED COPY OF THE FIRE AND SAFETY PLAN OR SUBMIT FOR REVIEW AND APPROVAL A REVISED FIRE AND SAFETY PLAN.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Fire Fighting
Issued 22 August 1990
Resolved
DEMONSTRATE OPERATION OF LOUVER CLOSURE FOR EMERGENCY GENERATOR SPACE. THISSPACE MUST BE MANNED WHILE EMERGENCY GENERATOR IS IN OPERATION UNTIL LOUVERCLOSURE OPERATES PROPERLY.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Lifesaving
Issued 22 August 1990
Resolved
PROPERLY STENCIL PORT LIFE BOAT WITH NAME, HAILPORT AND CAPACITY.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Lifesaving
Issued 22 August 1990
Resolved
MARK RELEASING GEAR FOR BOTH LIFEBOATS WITH A WHITE STRIP ACROSS THE WIDTH OF BOAT.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Lifesaving
Issued 22 August 1990
Resolved
PROPERLY STENCIL ALL STOWAGE BOXES ON BRIDGE WINGS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
CALIBRATE ALL GUAGES ON MAIN CONSOLE, INCLUDING RECALIBRATION OF PORT BOILER DRUM PRESSURE GUAGE.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Lifesaving
Issued 22 August 1990
Resolved
CONDUCT A FIRE AND BOAT DRILL.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Lifesaving
Issued 22 August 1990
Resolved
PROVIDE TWO(2) SMOKE FLOATS FOR BRIDGE WING LIFE BOUYS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
PROVIDE SUITABLE NICKEL-CADMIUM BATTERIES FOR USE AS EMERGENCY BATTERIES.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
DEMONSTRATE OPERATION OF DIESEL GENERATOR ALARM LIGHTS AND EMERGENCY GENERATOR ALARM LIGHTS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
REMOVE GROUND ON AFT 120VAC DISTRIBUTION PANEL TO MACHINERY SPACE LIGHTING.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
INSTALL SUITABLE SIZED FUEL OIL CONTAINMENT TANKS FOR BOTH PORT/STBD F/O FILL HEADER MANIFOLDS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVIDE SUITABLE METALLIC CONNECTION TO FORWARD BURNERS ON BOTH BOILERS. REMOVE LENGTHS OF NON-METALLIC HOSES.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Documentation
Issued 3 May 1989
Resolved
PRIOR TO ACTIVATION COMPLETE ALL INSPECTION ITEMS FOR INSPECTION FOR CERTIFICATION.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Fire Fighting
Issued 25 July 1984
Resolved
FREE UP MANUAL FIRE DAMPER EXHAUST SYSTEM 01-101-2 FOR EMERGENCY GENERATOR ROOM AT PORT STACK HOUSE.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
REPLACE MISSING WT CLOSURE ON #4 OBSW BALLAST TANK VENT AT THE PORT STACK HOUSE.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
RENEW WASTED VENT IN WAY OF E/R VENT DAMPERS AT THE PORT STACK HOUSE.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
REPLACE WT VENT COVER FOR THE VENT IN WAY OF #17.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
REPLACE MISSING WT COVER FOR #1 SW BALLAST TANK ON THE STARBOARD SIDE.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Accommodation/Occupational Safety
Issued 25 July 1984
Resolved
RENEW WASTED CABLE GUARDS ON THE PORT AND STARBOARD DAVITS.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Lifesaving
Issued 25 July 1984
Resolved
CHANGE DIESEL FUEL IN THE MOTOR LIFEBOAT.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Lifesaving
Issued 25 July 1984
Resolved
REPLACE "D" RINGS ON SOLAS COVER FOR LIFEBOAT #1 OR REPLACE ENTIRE SOLAS COVER.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Lifesaving
Issued 25 July 1984
Resolved
RENEW SOLAS COVER FOR LIFEBOAT #2.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Navigation
Issued 25 July 1984
Resolved
REPAIR OR REPLACE MANUAL SHIPS WHISTLE ON THE BRIDGE.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Engineering
Issued 25 July 1984
Resolved
MAKE REPAIRS TO THE LOW LUBE OIL PRESSURE TRIP FOR THE MAIN TURBINE.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Electrical
Issued 25 July 1984
Resolved
PLACE ADDITIONAL RUBBER MATTING AT THE REAR OF THE EMERGENCY SWITCHBOARD.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
REPAIR/RENEW WASTED LIFE RAILS ON THE PORT SIDE IN WAY OF 18 AND 19 AND THESTARBOARD SIDE IN WAY OF 17, 18, 23 AND 24.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Electrical
Issued 25 July 1984
Resolved
LINE THE BATTERY BOX FOR THE EMERGENCY GENERATOR START WITH LEAD.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
REPLACE THE MISSING DOG ON THE PORT "PIPE AND ACCESS TUNNEL" VENT.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
RENEW WASTED VENT SCREENING IN WAY OF THE PORT AND STARBOARD STACK HOUSES.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
FREE UP THE VENT CLOSURE TO THE STARBOARD "PIPE AND ACCESS TUNNEL" VENT.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Accommodation/Occupational Safety
Issued 25 July 1984
Resolved
REMOVE THE LOCKINGBARS FROM THE SHIP'S STORES REEFER BOXES OR PROVIDE AN ALARM SYSTEM. SUBMIT PLANS ON INSTALLATION OF THE REEFER ALARM SYSTEM TO THE COAST GUARD FOR APPROVAL.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Accommodation/Occupational Safety
Issued 25 July 1984
Resolved
MAKE PERMANENT REPAIRS TO THE AC COOLING OVERBOARD LINE.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Fire Fighting
Issued 25 July 1984
Resolved
SEAL OPEN ALL FIREMAIN CUT-OUT VALVES (TIE WRAPS FOR BUTTERFLY TYPE AND CHAIN WITH LOCK FOR HANDWHEEL TYPE) AND PROVIDE AN UPDATED DIAGRAM OF SYSTEM.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Accommodation/Occupational Safety
Issued 25 July 1984
Resolved
PROVIDE AND POST A LETTER FROM THE COMMANDANT, U. S. COAST GUARD, INDICAT- ING ACCEPTANCE OF THE RED FOX SEWAGE TREATMENT UNIT.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Unknown
Issued 25 July 1984
Resolved
MAKE THE DC HEATER AVAILABLE FOR INTERNAL EXAMINATION BY A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Unknown
Issued 25 July 1984
Resolved
TEST THE RELIEF VALVE FOR THE DC HEATER TO THE SATISFACTION OF A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Accommodation/Occupational Safety
Issued 25 July 1984
Resolved
PROVIDE A PRESS-TEMP RELIEF VALVE THAT MEETS ANSI STANDARD 721.22 AND WHICH RELIEVES AT 210 DEGREES F AND BELOW THE MAWP OF THE ELECTRIC H.W. HEATER IN THE SEWAGE TREATMENT ROOM.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Electrical
Issued 25 July 1984
Resolved
TAG AND DISABLE ALL ELECTRICAL CIRCUITS TO HOMOGENIZER SYSTEM OR MAKE PERMANENT REPAIRS TO THE EQUIPMENT.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
REPLACE WT COVERS ON AFT OF THE SOUTH WEST BALLAST TANK VENTS ON THE PORT AND STARBOARD SIDES.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
FREE UP WT COVER FOR THE "N.E.F.M. SHAFT ALLEY" VENT.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Unknown
Issued 25 July 1984
Resolved
REPLACE WASTED BASE AND DRIP PAN ON PORT BUNKER LOADING MANIFOLD.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
REPLACE 2 MISSING PINS IN WT CLOSURE FOR #6 W.G.F.O. TANK VENTS ON PORT SIDE.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Construction/Loadline
Issued 25 July 1984
Resolved
REPLACE MISING WT COVERS ON STANDBY FUEL PUMP AND BILGE AND BALLAST SEA CHEST VENT.
Condition: Unknown
Due 25 July 1984
Resolved 25 July 1984
Electrical
Issued 29 August 1983
Resolved
PROVE SATISFACTORY OPERATION OF LOW LUBE OIL ALARM FOR DIESEL GENERATOR (SHIP'S SERVICE).
Condition: Unknown
Due 29 August 1983
Resolved 29 August 1983
Electrical
Issued 29 August 1983
Resolved
PROVE SATISFACTORY OPERATION OF SUPPLY AIR VENT LOUVERS FOR EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 29 August 1983
Resolved 29 August 1983
Electrical
Issued 29 August 1983
Resolved
PROVE SATISFACTORY OPERATION OF REMOTE CONTROLS FOR NO. 6 HIGH SUCTION F.O.VALVE IN SHAFT ALLEY.
Condition: Unknown
Due 29 August 1983
Resolved 29 August 1983
Unknown
Issued 29 August 1983
Resolved
ALL REPAIRS ARE TO BE TO THE SATISFACTION TO THE COGNIZANT COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 29 August 1983
Resolved 29 August 1983
Unknown
Issued 29 August 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESEL DELTA NORTE, DN550900
Condition: Unknown
Due 29 August 1983
Resolved 29 August 1983