MONTE CARLO is a 1973 passenger vessel (inspected). The Coast Guard has recorded 92 inspections since 1985, most recently in February 2026, along with 168 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1985 to 2026. Most recent: inspection, 20 February 2026.

Built
1973
Last inspected
20 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD6745
Flag
UNITED STATES
368014440
Maury page id
psix-47660

Inspections, by type

…with no type recorded11
…past their stated due date1
Years with a record 39 calendar years (1985–2026)
The 92 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)71.0 ft × 22.3 ft × 6.4 ft
Registered tonnagegross 86 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT N VILLEGAS JR · VENTURA, CA, UNITED STATES · built 1973
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN PEDRO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ8235MMSI 368014440 · active · compulsorily equipped · granted 29 November 2017, expires 29 November 2027
WDD6745MMSI 367176990 · expired · compulsorily equipped · granted 30 March 2007, cancelled 3 June 2017
WTE2923MMSI not assigned · expired · compulsorily equipped · granted 20 January 1999, cancelled 23 May 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 92

20 February 2026 Deficiency Check · Annual Inspection · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8267680
22 January 2025 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8066841
14 January 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8009126
26 July 2024 Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7968144
14 December 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7806966
29 November 2023 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7806960
7 December 2022 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7577670
15 June 2022 Plan Review "T" Boat · Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7485387
8 March 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7407606
24 February 2022 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7405486
4 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7150251
2 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6919323
16 January 2020 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6881877
2 December 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6865837
14 November 2019 Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6855985
23 January 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6607416
2 January 2018 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6341795
12 December 2017 DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6306028
29 November 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6299220
29 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6314620
17 February 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6086250
26 February 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5811494
4 February 2016 Administrative Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5800780
28 March 2014 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4824849
12 March 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4806734
17 January 2012 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4219286
10 March 2010 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3693304
11 January 2010 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3690174
7 January 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3620588
7 April 2009 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3447658
21 February 2009 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3520623
14 January 2008 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3126155
10 January 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3123833
24 May 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2939439
9 April 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2903065
5 April 2006 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2594069
10 January 2006 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2560547
23 August 2005 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2473282
11 April 2005 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2326225
6 October 2004 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2215148
25 May 2004 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2086145
2 April 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2036237
28 June 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1851049
7 March 2003 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1739162
15 January 2003 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1730773
7 January 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1727232
12 February 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1485994
12 December 2001 Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1474433
9 January 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1413856
10 August 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 821728
11 January 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1423307
24 June 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1457668
1 June 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 803560
11 March 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 802933
26 January 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1410023
4 December 1998 Deficiency Check · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381400
30 June 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1129053
15 January 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368562
14 January 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1402371
16 December 1996 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1091524
13 December 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390391
18 August 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1090755
1 March 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1459978
7 November 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1442316
1 August 1995 Type not recorded
No type recorded · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 676884
27 February 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1174205
4 May 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1168811
5 April 1994 Deficiency Check · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 856089
2 March 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 854608
3 September 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 833640
2 September 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 136215
2 April 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1143061
8 March 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144032
20 April 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1256546
31 March 1992 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 959635
12 March 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 951735
11 April 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 908664
22 March 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 916052
22 March 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1227561
6 April 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1220839
27 March 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 907788
13 April 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1038568
6 April 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1210635
7 April 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1198006
17 December 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1014108
8 December 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1312023
10 August 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1336855
13 August 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1310195
14 April 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1306594
10 September 1985 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 990893
9 August 1985 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1291857
10 January 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1283949

Deficiency record · 168

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 February 2026 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Fwd engine room bulkhead centerline, and aft engine room bulkhead stbd side have bulkhead penetrations not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2026
Resolved 25 February 2026
Resolution: Attended vessel, viewed holes appropriately filled
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 February 2026 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Broken conduit found resting on wiring in freezer compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2026
Resolved 25 February 2026
Resolution: Attended vessel, conduit re-attached.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 February 2026 Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Wheelhouse breaker distribution panel door unable to remain closed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2026
Resolved 25 February 2026
Resolution: Attended vessel, magnet used to secure door.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 February 2026 Resolved
Spaces containing machinery shall be fitted with at least two ducts to furnish natural or mechanical supply and exhaust ventilation. Vessel has no installed ventilation ducts for the engine room. Submit E/R supply and exhaust ventilation installation plans for review and approval by the [name withheld] fixed ventilation as per OCMI approved plans. 46 CFR 182.20-45(c)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 April 2026
Resolved 10 April 2026
Resolution: Observed proper installation of ventilation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 February 2026 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a), vessels more than 65 ft require 02 fixed power bilge pumps (50 GPM). Vessel only has one fixed power bilge pump. Submit bilge pump installation plans for review and approval by the [name withheld] secondary power bilge pump as per OCMI approved plans. 46 CFR 182.520(a)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 April 2026
Resolved 10 April 2026
Resolution: Observed proper operation and installation of second power bilge pump
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 February 2026 Resolved
Machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads. E/R door leading to accommodation space is not vapor tight. 46 CFR 182.35-1(a)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2026
Resolved 10 April 2026
Resolution: Observed proper sealing of engine room door.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 February 2026 Resolved
There shall be a minimum of two fire hydrants on all mechanically propelled "L" vessels. One length of 1.5 in diameter, 50 ft length hose shall be provided at each fire hydrant. Vessel only has one 1.5 in diameter fire hose installed fwd. Submit aft fire hose installation plans for review and approval by the [name withheld] aft fire hose as per OCMI approved plans. 46 CFR 181.15-5
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 April 2026
Resolved 10 April 2026
Resolution: Observed proper installation and operation of aft fire hose station.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 February 2026 No resolution recorded
On a vessel on a protected or partially exposed route, a watertight coaming with a height of at least 6 inches must be provided under each weather tight door. Coaming height does not meet 6 inch requirement in each weather tight door entryway. 46 CFR 179.360(d)(1)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 April 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 February 2026 Resolved
Spanner wrenches must be provided where 1.5 in diameter firehose is required. Fwd and Aft fire station did not have required spanner wrench.46 CFR 181.310(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2026
Resolved 10 April 2026
Resolution: Observed 02 spanner wrenches for fire stations.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 February 2026 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Update emergency instructions to state E/R door to be closed in the case of E/R fire or before activation of E/R fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 10 April 2026
Resolution: Removed requirement as engine room door seals properly and ventilation installed
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 December 2023 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life float (25 pax) carried on board were faded and no longer vivid in color as designed by the manufacture, renew/replace life-floats/buoyant apparatus.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2024
Resolution: L/F repainted
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 14 December 2023 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Mark upper deck for maximum allowed passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2024
Resolution: 2nd deck marked
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 March 2022 Resolved
The EPIRB test (monthly) shall be logged or otherwise documented. The EPIRB test has not been logged since December 2021.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
Resolution: Operator submitted photo of log book in place with EPIRB test logged 8 MAR.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 March 2022 Resolved
If the life float does not have a painter attachment fitting, a means for attaching the painter must be provided by a wire or line that encircles the body of the device. Line was not wrapped around the body of the life float.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
Resolution: Operator provided photo of life floats with painter properly secured around body of float.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 March 2022 Resolved
Each distribution panel must be totally enclosed and of the dead front type. The galley distribution panel has two open spaces at the bottom of the panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
Resolution: Operator provided photo of switchboard with blanks installed in unused slots.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2021 Resolved
An adult lifejacket must be provided for each person carried on board the vessel. MI condemned one (01) Kapok lifejacket.
Action required: 10 - Deficiency Rectified
Due 4 March 2021
Resolved 4 March 2021
Resolution: O/O replaced with new approved lifejacket on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2021 Resolved
Each lifejacket must be marked with type I retroreflective material. MI found 7 Adult lifejackets requiring new retroreflective material.
Action required: 10 - Deficiency Rectified
Due 4 March 2021
Resolved 4 March 2021
Resolution: O/O applied new type I retroreflective tape to the required lifejackets on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 March 2021 Resolved
All vessel must have navigation lights that are in compliance with the applicable section of the International and Inland Navigation Rules. MI found stern light inoperable.
Action required: 10 - Deficiency Rectified
Due 4 March 2021
Resolved 4 March 2021
Resolution: O/O repaired stern light on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 December 2019 Resolved
Vessel failed to conduct drydock exam IAW COI
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2019
Resolved 21 January 2020
Resolution: Vessel conducted satisfactory hull exam for credit drydock.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 January 2019 Resolved
Prove proper operation of pre-engineered fire extinguishing system for the generator. Found light and audible alarm for shutdown inoperable at operating station.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2019
Resolved 23 January 2019
Resolution: Discrepancy corrected later the same day, to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2019 Resolved
Make freezer compartment/sonar compartment bulkhead watertight. Found space surrounding wire penetration on port side to be not watertight.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 23 January 2019
Resolution: This discrepancy was corrected prior to departure, to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2019 Resolved
Replace unservicable retroreflective marterial on 30 identified lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 23 January 2019
Resolution: This discrepancy was corrected prior to departure, to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 January 2019 Resolved
Replace plastic zip ties in sonar compsrtment and fuel tank compartment with metal supports. Found multiple runs of cable/wire to be supported to overhead beams with zipties.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2019
Resolved 30 January 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 January 2019 Resolved
Provide EPIRB log for monthly EPIRB testing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 23 January 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 12 December 2017 Resolved
PROVIDE PROOF OF SUPERVISOR TRAINING FOR EAP TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46CFR16.401(b)
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 2 January 2018
Resolution: Owner/Operator provided proof of Supervisory Training for EAP.
Lifesaving › Lifefloat › Capacity
Issued 12 December 2017 Resolved
PROVIDE AND INSTALL LIFE FLOAT TO ACCOMODATE 100% OF TOTAL PERSONS PERMITTED ON BOARD TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. TOTAL PERSONS REDUCED TO 75. 46CFR180.205(a)
Action required: 705 - Other - as specified
Resolved 12 December 2017
Resolution: OWNER PROCURED 15 PERSON LIFEFLOAT AND INSTALLED PROPERLY. TOTAL LIFEFLOAT CAPACITY: 90
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 12 December 2017 Resolved
PROVIDE 2 ADULT PFD'S. TOTAL PERSON COUNT REDUCED TO 84. ITEM #2 TAKES PRECEDENCE. 46CFR180.71(a)
Action required: 705 - Other - as specified
Resolved 12 December 2017
Resolution: OWNER PROCURED 2 NEW ADULT SIZED PFDS.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 February 2017 Resolved
Dead end wires in the lazerrete.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 22 February 2017
Resolution: Master removed all dead end wiring.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 February 2017 Resolved
Found multiple hose clamps missing on the overboard discharge lines for both MDE’s and SSDG’s
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 22 February 2017
Resolution: Master placed two hose clamps on all overboard discharge lines for both MDE’s and SSDG’s.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 February 2017 Resolved
Found lighting in the lazarrete to be inoperable and hanging from overhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 22 February 2017
Resolution: New LED lights were placed in the lazerrete
Fire Fighting › Fire Main › Pressure
Issued 17 February 2017 Resolved
Pressure gauge on the fire main system was not operating properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 22 February 2017
Resolution: New pressure gauge was placed on the fire pump
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 February 2017 Resolved
Found temporary type connectors on batteries in the lazerrete and tank room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 22 February 2017
Resolution: Permanent connections were placed on all battery installations
Lifesaving › Lifefloat › Float-free Link
Issued 17 February 2017 Resolved
Found float-free link for life floats improperly installed
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 17 February 2017
Resolution: Installed float free link properly
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 February 2016 Resolved
Complete a satisfactory hull exam with a Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2016
Resolved 12 February 2016
Resolution: Credit drydock conducted to the satisfaction of the attending Marine Inspector.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 March 2014 Resolved
Line connecting ring buoy and waterlight was too short. Item was corrected on the spot.
Due 12 March 2014
Resolved 12 March 2014
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 12 March 2014 Resolved
Retroreflective tape on 01 child lifejacket was missing. Item was replaced on the spot.
Due 12 March 2014
Resolved 12 March 2014
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 March 2014 Resolved
Watertight transverse bulkhead had multiple holes from wiring. Holes were properly filled and item was fixed on the spot.
Due 12 March 2014
Resolved 12 March 2014
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 March 2014 Resolved
A Longitudinal frame located in the laz was unsupported and sagging. Item was not repaired following the vessel's repower. Issued 01 CG-835 to provide support for the deck in the laz.
Action required: 705 - Other - as specified
Due 2 April 2014
Resolved 28 March 2014
Resolution: Vessel owner installed new stainless steel support stanchion beneath deck in lazerette inboard of stabroard generator. Above deck was well supported and stanchion was securely installed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 17 January 2012 Resolved
Repair port main engine wet exhaust leak.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 8 February 2012
Resolution: Wet exhaust leak repaired.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 March 2010 Resolved
Install covers for missing breakers in Galley and Bridge pannels
Action required: 705 - Other - as specified
Resolved 24 May 2010
Resolution: Covers have been installed
Fire Fighting › Fire Hoses › Condition
Issued 10 March 2010 Resolved
Replace fire hose due to rupture
Action required: 705 - Other - as specified
Due 13 April 2010
Resolved 13 April 2010
Resolution: New hoses was purchased and receipt was faxed to the office
Fire Fighting › Grease Extraction Hood › General
Issued 10 March 2010 Resolved
Repair/replace galley ventilation fan
Action required: 705 - Other - as specified
Resolved 24 May 2010
Resolution: Fan has been replaced
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 7 January 2010 Resolved
Contactor cover for anchor capstain is missing. Located in forward compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 18 February 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 7 January 2010 Resolved
Broken light fixture on aft stbd bulkhead in fuel tank space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 January 2010
Resolved 15 January 2010
Resolution: Fixture was removed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 January 2010 Resolved
In accordance with 46 CFT 181.400 & 181.410, vessel must provide a fixed fire extinguishing system for aft generator compartment. Plans for system must be provided to USCG Sector LA/LB prior to installation.
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 15 January 2010
Resolution: Installed new SEA-FIRE system. System was tested on 15JAN2010.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 7 January 2010 Resolved
Fuel leaking from port forward fuel tank.
Action required: 705 - Other - as specified
Due 30 January 2010
Resolved 18 February 2010
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 January 2010 Resolved
Clean Rot to good wood on overhead forward bulkhead and at entrace to engine room space. Treat areas.
Action required: 705 - Other - as specified
Due 30 January 2010
Resolved 18 February 2010
Documentation › Certificates/Documents › FCC SSL
Issued 7 April 2009 Resolved
Provide current FCC safety certificate prior to operating 1000 feet from shore.
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 10 April 2009
Resolution: Verified new Safety Radio Telephony certificate on-board. Updated MISLE vsl docs accordingly.
Communications › Radio Communications › EPIRB
Issued 7 April 2009 Resolved
Provide current NOAA registration for EPIRB prior to operating over 3 miles from shore.
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 10 April 2009
Resolution: Verified updated EPIRB registration on-board.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 April 2009 Resolved
Make the fwd and aft engine room bulkheads watertight.
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 10 April 2009
Resolution: Verified fwd & aft engine room bulkhead penetrations (old bolt holes) sealed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 April 2009 Resolved
Provide double bands for all exhaust systems for main engines and generators, where applicable.
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 10 April 2009
Resolution: Verified all exhaust stystems double-clamped (banded).
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 January 2008 Resolved
Provide proper brackets for self igniting lights attached to all lifefloats and ensure unobstructed mounting.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 15 February 2008
Resolution: Installed bracket for lights attached to lifefloats
Personnel › Training › First Aid/CPR
Issued 14 January 2008 Resolved
Provide CPR certification for 50% of crew onboard.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 15 February 2008
Resolution: Provided CPR cards for 50% of crew.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 January 2008 Resolved
Install cover of fluorescent light on port side of engineroom.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 15 February 2008
Resolution: Installed cover on fluorescent light on port side of engine room
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 January 2008 Resolved
Install cover on 12 volt junction box on middle aft bulkhead in fuel compartment.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 15 February 2008
Resolution: Installed cover on junction box on middle aft bulkhead in fuel compartment.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 January 2008 Resolved
Install cover on fluorescent light and light switch box in water hater compartment.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 15 February 2008
Resolution: Installed cover on light and light switch box in water heater compartment
Lifesaving › Rescue Boat › Carriage Requirement
Issued 9 April 2007 Resolved
In lieu of rescue boat, provide sufficient equipment to recover a helpless person from the water as required by 46 CFR 180.120.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 14 January 2008
Resolution: Vessel provided rescue ladder to recover a helpless person from the water.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 April 2007 Resolved
Provide metal supports for electrical wiring throughout the engine room as required by 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 April 2007 Resolved
Provide guards for rotating machinery on center engine as required by 46 CFR 177.960
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Resolution: Guard installed.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 April 2007 Resolved
Provide documentation of one hour supervisor EAP training as required by 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Resolution: Training completed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 5 April 2006 Resolved
Provide method to lock overboard MSD discharge prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2006
Resolution: Locks were installed on the MSD discharge to the satisfaction of the attending Marine Inspector.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 5 April 2006 Resolved
Trace source of diesel fuel leak on port forward/aft fuel tanks. If leak is detected repair prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2006
Resolution: No visible leaks were discoverd by the attend Marine Inspectors.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 5 April 2006 Resolved
Renew/repair petcock fule drain on starboard forward fuel tank prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2006
Resolution: The petcock fuel drain was repaired/replaced on the starboard fuel tank.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 5 April 2006 Resolved
Provide grounding of fuel tanks IAW 46 CFR 182.445g
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2006
Resolution: The fuel tanks were properly grounded to the satisfaction of the attending Marine Inspector.
Construction/Loadline › Penetrations › Pipe Flange
Issued 5 April 2006 Resolved
Make bulkhead penetrations in fuel compartment watertight to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 5 May 2006
Resolved 6 April 2006
Resolution: The bulkhead penetrations in the fuel compartment were sealed and made watertight to the satisfaction of the attending Marine Inspector.
Engineering › Bilge Water Management System › Not Operational
Issued 5 April 2006 Resolved
Prove proper operation of fuel tank compartment bilge high level alarm prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2006
Resolution: The bilge high level alarm proved to be operational, both audible and visual, to the satisfaction of an attending Marine Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 10 January 2006 Resolved
Repair two sections of fiberglass on starboard chine.
Due 17 January 2006
Resolved 13 January 2006
Construction/Loadline › Penetrations › Flange Pad
Issued 10 January 2006 Resolved
Repair bonding wire on center shaft strut nuts in lazarett.
Due 17 January 2006
Resolved 13 January 2006
Construction/Loadline › Structures › Deck Plating
Issued 10 January 2006 Resolved
Secure deck support near starboard generator.
Due 17 January 2006
Resolved 13 January 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 10 January 2006 Resolved
Properly terminate dead end wires on aft bulkhead in tank space.
Due 17 January 2006
Resolved 13 January 2006
Resolution: Wires were for light fixture, repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 January 2006 Resolved
Replace/install globe on light in sonar room.
Due 17 January 2006
Resolved 13 January 2006
Construction/Loadline › Structures › Superstructure
Issued 10 January 2006 Resolved
Repair window in port head.
Due 17 January 2006
Resolved 13 January 2006
Construction/Loadline › Penetrations › Valve Flange
Issued 10 January 2006 Resolved
Repair/replace bait tank ball valve (port side) and center M/E cooling ball valve.
Due 17 January 2006
Resolved 13 January 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 January 2006 Resolved
Install metallic valves on both sides of the watertight bulkhead, at the bulkhead, for port and starboard sink drain pvc piping. 46CFR 182.40-1
Due 17 January 2006
Resolved 13 January 2006
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 23 August 2005 Resolved
Prove proper operation of the port main diesel engine prior to operation and carriage of passengers per 46 CFR 182.100.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2005
Resolved 26 August 2005
Resolution: Provided proper operation of the port main diesel engine.
Documentation › Logs/Records › Report of Marine Accident, Injury or Death
Issued 23 August 2005 Resolved
Provide CG-2692 Report of Marine Casualty per 46 CFR Part 4.
Due 30 August 2005
Resolved 26 August 2005
Resolution: Provided CG-2692.
Personnel › Training › First Aid/CPR
Issued 11 April 2005 Resolved
Vessel crew does not have CPR cards.
Action required: 705 - Other - as specified
Due 11 May 2005
Resolved 30 May 2005
Electrical › Electrical Distribution System (service)
Issued 2 April 2004 Resolved
Remove all unused electrical circuits and conduct general, electrical housekeeping; ensuring all cabling and wiring meet the requirements of 46 CFR 183.340 LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2004
Resolved 9 May 2004
Resolution: Removed all unused electrical circuits and conduct general, electrical housekeeping; ensured all cabling and wiring meet the requirements of 46 CFR 183.340
Engineering › Bilge Water Management System
Issued 2 April 2004 Resolved
Label each bilge pump main suction valve. LEGACY COMPONENT DESC: Manifold
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2004
Resolved 9 May 2004
Resolution: Labeled each bilge pump main suction valve.
Engineering › Fuel Oil Storage/Transfer System
Issued 2 April 2004 Resolved
Remove kinks from 2 of 4 fuel tank vent hoses. LEGACY COMPONENT DESC: Ventilation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2004
Resolved 9 May 2004
Resolution: Removed kinks from 2 of 4 fuel tank vent hoses.
Electrical › Electrical Distribution System (service)
Issued 2 April 2004 Resolved
Properly label each circuit on distribution panel in generator room. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2004
Resolved 9 May 2004
Resolution: Properly labeled each circuit on distribution panel in generator room.
Lifesaving › Buoyant Apparatus
Issued 15 January 2003 Resolved
All four lifefloats were bound together in one grouping (on one weak link) which exceeded 200 lbs. and would be very difficult to launch. Groupings need to be reduced to only two lifefloats per group which would require another weaklink and painter, or provide launching device.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2003
Resolved 7 March 2003
Lifesaving › Buoyant Apparatus
Issued 15 January 2003 Resolved
Water light on STBD upper life float inoperable. LEGACY COMPONENT DESC: Water light
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2003
Resolution: Battery terminal connectors were loose. After tightening, the light worked fine.
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 15 January 2003 Resolved
Grab lines and Water light lanyard on PORT lifering are deteriorated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2003
Resolution: Replaced lifering and lanyard
Documentation › Logs/Records
Issued 15 January 2003 Resolved
No Red Cross first aid/CPR cards were provided. Provide for 50% of the crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 7 March 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 January 2003 Resolved
First aid kit box had broken lid and some required items were missing, such as gause bandages. Other individual items had been opened and may not be clean/sterile. LEGACY COMPONENT DESC: First aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 7 March 2003
Navigation › Piloting/Steering
Issued 15 January 2003 Resolved
Light on magnetic compass inoperable LEGACY COMPONENT DESC: Magnetic Compass
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 7 March 2003
Communications › Radio Communications
Issued 15 January 2003 Resolved
EPIRB battery was expired and mounting bracket had expiration date of 31JAN03, so hydrostatic release may be expiring on 31JAN03. Route restricted to no more than 3nm from harbor of safe refuge. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 3 February 2003
Fire Fighting › Nozzles
Issued 15 January 2003 Resolved
The aft nozzle had been altered in the past whereas someone separated the swivel and welded/brazed a steel pipe nipple in between the swivel and nozzle. Althouth the assembly functioned, it was very corroded and failing. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 17 January 2003
Resolution: Owner provided new brass adapter that connected the hose and the nozzle.
Engineering › Bilge Water Management System
Issued 15 January 2003 Resolved
Vessel needs a second, fixed, power-driven bilge pump using alternate source of power as per 182.25-10 "OLD T". LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 9 April 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 15 January 2003 Resolved
Remove loop from port/aft fuel tank vent hose and install to gradient upward to prevent fuel from being trapped in the hose. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 17 January 2003
Pollution Prevention/Response › Prevention Equipment
Issued 15 January 2003 Resolved
Vessel has two MSD type III holding tanks in the engineroom, installed just inboard of the port and stbd main engines. The ovbd valves need some type of reasonable locking device IAW 33 CFR 159.7 (c). LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 7 March 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 15 January 2003 Resolved
On the stbd side of the ladder in the engineroom there is a small fuel distribution manifold. One of the valves leads to a port on the manifold labeled "CENTER MAIN" that is not being used. O/O is to install a cap to prevent fuel flow in case the valve is opened. LEGACY COMPONENT DESC: Manifold
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 17 January 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 15 January 2003 Resolved
Properly install/secure/mount J/W heat exchanger on port generator so it can not vibrate loose and place strain on R/W hoses or connections. LEGACY COMPONENT DESC: J/W heat exchanger
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 17 January 2003
Electrical › Electrical Distribution System (service)
Issued 15 January 2003 Resolved
Repair or remove the old lighting circuit in generator room, just below the hatch, in the overhead, that leads to the light on the aft bulkhead. The conduit is corroded, broken, and chafing against the wires inside. Provide two covers for junctions on same circuit, in fwd part of generator room. LEGACY COMPONENT DESC: Wiring
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 17 January 2003
Resolution: Removed all wiring, conduit, and junction boxes on old lighting circuit.
Engineering › Diesel Engine (auxiliary)
Issued 15 January 2003 Resolved
Provide rotating machinery guard for drive end of port generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 9 April 2004
Electrical › Electrical Distribution System (service)
Issued 15 January 2003 Resolved
Remove or properly cap dead end wires on fwd blkd of generator room. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 17 January 2003
Resolution: Removed all dead ended wires and circuits.
Electrical › Electrical Distribution System (service)
Issued 15 January 2003 Resolved
Provide grounding wire to all recepticles, not the recepticle box. LEGACY COMPONENT DESC: Grounding Conductor
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 9 April 2004
Engineering › Diesel Engine (auxiliary)
Issued 15 January 2003 Resolved
Provide double hoseclamp on all raw water connections in the generator room (generator cooling).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 15 January 2003
Pollution Prevention/Response › Prevention Equipment
Issued 15 January 2003 Resolved
Reconfigure both msd vents to vent to outside atmosphere instead of the engineroom. (verbal) LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 7 March 2003
Construction/Loadline › Structures
Issued 7 January 2003 Resolved
Plug or patch the holes located in all watertight bulkheads. Holes are apparently from old wire runs and penetrate upper section of all bulkheads. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Resolved 15 January 2003
Resolution: Vsl used plywood seated in 5200 and secured w/ wood screws to seal the holes.
Construction/Loadline › Penetrations
Issued 7 January 2003 Resolved
Recap the old through-hull fitting located along the starboard side of the engine room, in the mid-section of the compartment, about 6" down from the shear clamp. Recap the fitting closer to the hull.
Action required: 705 - Other - as specified
Resolved 15 January 2003
Electrical › Electrical Distribution System (service)
Issued 7 January 2003 Resolved
Many of the new flourescent light fixtures in the lower compartments have been wired with orange portable electric cord. Rewire fixtures with UL approved boat cable. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Resolved 15 January 2003
Communications › Alarms/Indicators
Issued 7 January 2003 Resolved
In transducer space, replace frayed wiring on the bilge high level alarm. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Resolved 15 January 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 7 January 2003 Resolved
In tankspace, remove loops from the fuel tank vent hoses. Make hoses go straight overboard with no dips or loops. LEGACY COMPONENT DESC: Vent Pipe
Action required: 705 - Other - as specified
Resolved 9 April 2004
Navigation › Collision/Grounding Avoidance
Issued 7 January 2003 Resolved
Reconnect corroded terminal on the sternlight so that it is operational. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Resolved 15 January 2003
Operations/Management
Issued 7 January 2003 Resolved
Before carrying passengers conduct underway checkride to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2003
Fire Fighting › Nozzles
Issued 12 February 2002 Resolved
Fire nozzle was rusted. Owner corrected the problem on the spot.
Due 12 February 2002
Resolved 12 February 2002
Lifesaving › Launching Appliances
Issued 12 February 2002 Resolved
(2) Lifefloats were not labeled with the vessel's name.
Due 26 February 2002
Resolved 8 January 2003
Lifesaving › Launching Appliances
Issued 12 February 2002 Resolved
Lifefloats did not have the proper label tag on the weaklink.
Due 26 February 2002
Resolved 8 January 2003
Engineering
Issued 12 February 2002 Resolved
The forward most portside fuel shutoff valve was inoperative.
Due 12 February 2002
Resolved 12 February 2002
Documentation › Manuals/Policy Documentation
Issued 12 February 2002 Resolved
Vessel did not have current/corrected CG Light List on board
Due 26 February 2002
Resolved 7 March 2003
Documentation › Manuals/Policy Documentation
Issued 12 February 2002 Resolved
Vessel did not have updated/corrected charts on board.
Due 26 February 2002
Resolved 8 January 2003
Lifesaving
Issued 12 February 2002 Resolved
Vessel had expired items in first aid kit. Owner corrected the item on the spot.
Due 12 February 2002
Resolved 12 February 2003
Electrical › Electric Generation Source (service)
Issued 12 December 2001 Resolved
Provide circuit protection for all AC and DC loads, including instrumentation.
Action required: 705 - Other - as specified
Due 12 January 2002
Resolved 25 January 2002
Electrical
Issued 12 December 2001 Resolved
Provide a shutoff switch in the pilot house for the power ventilation system, including the power ventilation systems in the engine room and generator room as per 46 CFR 177.600.
Action required: 705 - Other - as specified
Due 12 January 2002
Resolved 25 January 2002
Electrical › Electric Generation Source (service)
Issued 12 December 2001 Resolved
Provide generator nameplate data, generator main circuit breaker information, and main electrical feeder size for both generators, for approval.
Action required: 705 - Other - as specified
Due 12 January 2002
Resolved 25 January 2002
Electrical › Electric Supply System (service)
Issued 12 December 2001 Resolved
Install the electrical shoretie as per 46 CFR 183.390.
Action required: 705 - Other - as specified
Due 12 January 2002
Resolved 25 January 2002
Electrical › Electrical Distribution System (service)
Issued 12 December 2001 Resolved
Provide an electrical grounding conductor for all AC electrical circuits.
Action required: 705 - Other - as specified
Due 25 April 2002
Resolved 9 April 2004
Electrical › Electrical Distribution System (service)
Issued 12 December 2001 Resolved
Provide an electrical system for the tank room overhead lighting and installed pumps which is properly designed. The system should use approved cable and circuit protection.
Action required: 705 - Other - as specified
Due 12 January 2002
Resolved 25 January 2002
Electrical
Issued 12 December 2001 Resolved
Provide properly sized battery cutoff switches for the main engines starting batteries and house batteries.
Action required: 705 - Other - as specified
Due 12 January 2002
Resolved 25 January 2002
Navigation
Issued 10 August 2000 Resolved
Repair stern light prior to operation after sundown.
Condition: Unknown
Due 10 August 2000
Resolved 11 August 2000
Construction/Loadline
Issued 24 June 1999 Resolved
Clean oil from bilges and prove operation of bilge pumps.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 4 December 1998 Resolved
GRIND BACK TO GOOD GLASS AND REPAIR BLISTER ON PORT BOW
Condition: Unknown
Due 18 December 1998
Resolved 11 December 1998
Engineering
Issued 4 December 1998 Resolved
REPLACE CENTER SHAFT CUTLASS BEARINGS
Condition: Unknown
Due 18 December 1998
Resolved 11 December 1998
Construction/Loadline
Issued 4 December 1998 Resolved
SCRAPE BACK TO GOOD WOOD AND TREAT OVERHEAD BEAM PORTSIDE OF ENGINEROOM.
Condition: Unknown
Due 18 December 1998
Resolved 11 December 1998
Accommodation/Occupational Safety
Issued 4 December 1998 Resolved
REPLACE DETEORIATED GATE VALVE FOR MSD OVERBOARD.
Condition: Unknown
Due 18 December 1998
Resolved 11 December 1998
Construction/Loadline
Issued 4 December 1998 Resolved
REPAIR BILGE FOOT STRAINER IN FORWARD VOID.
Condition: Unknown
Due 8 December 1998
Resolved 11 December 1998
Engineering
Issued 14 January 1997 Resolved
Install flame screens in all fuel vents prior to carrying passengers for hire and not later than 17JAN97.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 14 January 1997 Resolved
Reapply load marks required by 46CFR185.620 prior to completion of next drydock.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Construction/Loadline
Issued 13 December 1996 Resolved
Conduct underway sea trial to check hull for working in presence of a CoastGuard inspector before carring passengers.
Condition: Unknown
Due 27 December 1996
Resolved 16 December 1996
Construction/Loadline
Issued 5 April 1994 Resolved
PROVIDE STRAINER FOR BILGE SUCTION IN LAZARETTE AND REATTACH FOOTING.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Documentation
Issued 5 April 1994 Resolved
POST CERTIFICATE OF INSPECTION UNDER TRANSPARENT MATERIAL ON BRIDGE.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Fire Fighting
Issued 5 April 1994 Resolved
REMOVE OR PROVIDE SERVICING FOR CARBON DIOXIDE B-II FIRE EXTINGUISHER IN LAZARETTE.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Construction/Loadline
Issued 5 April 1994 Resolved
CLEAN AND TREAT AROUND VENT OPENING IN ENGINE ROOM AMIDSHIPS.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Construction/Loadline
Issued 5 April 1994 Resolved
MAKE PENETRATIONS THROUGH FORWARD ENGINE ROOM BULKHEAD WATERTIGHT.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Electrical
Issued 5 April 1994 Resolved
REMOVE WIRENUTS FROM HOT WATER HEATER WITH PROPER CRIMPED CONNECTORS.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Accommodation/Occupational Safety
Issued 2 March 1994 Resolved
PROVIDE MEANS OF SECURING THE MSD OVERBOARD DISCHARGE VALVE WITH A LOCKING MECHANISM.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Electrical
Issued 2 March 1994 Resolved
REPLACE WINGNUTS ON ELECTRIC BATTERY TERMINALS WITH HEXNUTS IN KEEPING WITHGOOD MARINE PRACTICE.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Construction/Loadline
Issued 2 March 1994 Resolved
REMOVE OIL FROM THE BILGES.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Engineering
Issued 2 March 1994 Resolved
PROVE PROPER OPERATION OF THE AIR COMPRESSOR RELIEF VALVE.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Electrical
Issued 2 March 1994 Resolved
SECURE ELECTRIC OUTLET IN ENTRANCE TO THE GALLEY STAIRWELL AND PROVIDE A GROUND PLUG FOR THE MICROWAVE PLUG.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Documentation
Issued 8 March 1993 Resolved
PROVIDE DRAFT OR LOADING MARKS AS DESCRIBED IN 46 CFR 185.30-3 PRIOR TO COMPLETION OF NEXT SCHEDULED DRYDOCKING.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Engineering
Issued 12 March 1992 Resolved
INSTALL MACHINERY GUARDS ON PORT AND STARBOARD ALTERNATORS IN LAZARETTE._x001C_
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Electrical
Issued 12 March 1992 Resolved
INSTALL METALLIC CABLE HANGERS ON 24 INCH CENTERS IN LAZARETTE, GALLEY STORES, AND STORAGE COMPARTMENT LOCATED BELOW PASSENGER LOUNGE.
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Lifesaving
Issued 12 March 1992 Resolved
REPAIR OR REPLACE THE 1 DEFICIENT TYPE 1 ADULT PFD. VESSEL OPERATIONS RESTRICTED TO 99 ADULT PASSENGERS/CREW UNTIL CORRECTED.
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Fire Fighting
Issued 22 March 1991 Resolved
LABEL CO2 PULL IN WAY OF AFT FIRE STATION.
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991
Electrical
Issued 22 March 1991 Resolved
PROVIDE COVER FOR JUNCTION BOX IN GENERATOR ROOM PORTSIDE OVERHEAD, AND JUNCTION BOX FORWARD BULKHEAD OF COMPARTMENT BELOW GALLEY.
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991
Engineering
Issued 22 March 1991 Resolved
PROVIDE GUARD FOR BILGE PUMP ON CENTERLINE ENGINE AND DOUBLE CLAMP PUMP HOSES.
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991
Accommodation/Occupational Safety
Issued 6 April 1989 Resolved
REMOVE OR REPLACE WITH A CG APPROVED ITEM, THE PRESSURE VESSEL LOCATED IN THE ENGINEROOM.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Documentation
Issued 6 April 1989 Resolved
CORRECT AND PROPERLY RECORD CHANGE OF OWNER'S ADDRESS ON VESSEL'S DOCUMENT.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Lifesaving
Issued 6 April 1989 Resolved
MARK EPIRB WITH VESSEL'S CALL SIGN.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Lifesaving
Issued 6 April 1989 Resolved
REPAIR DAMAGE TO VSL'S LIFEFLOATS.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Electrical
Issued 6 April 1989 Resolved
PROVIDE PERMANENT WIRING AND PROTECTION FOR ENGINEROOM VENT FAN.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Construction/Loadline
Issued 6 April 1989 Resolved
MAKE FORWARD ENGINEROOM BULKHEAD WATERTIGHT AND FUMETIGHT.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Lifesaving
Issued 6 April 1989 Resolved
PROPERLY SECURE PENDANTS ON LIFEFLOATS.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Lifesaving
Issued 6 April 1989 Resolved
PROPERLY LASH PADDLES TO LIFEFLOATS.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Lifesaving
Issued 6 April 1989 Resolved
PROVE PROPER OPERATION OF WATERLIGHTS ON LIFEFLOATS.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Lifesaving
Issued 6 April 1989 Resolved
REPAIR DAMAGED NET ON LIFEFLOATS.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Lifesaving
Issued 6 April 1989 Resolved
PROPERLY SECURE WATERLIGHT TO RING BUOY.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Lifesaving
Issued 9 August 1985 Resolved
INSTALL FLOAT FREE GUIDES ON LIFE FLOATS ON HOUSE.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Lifesaving
Issued 9 August 1985 Resolved
LIMIT NUMBER OF PASSENGER TO 92 UNTIL 2 MORE ADULT PFD'S ARE PROVIDED
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Deck/Cargo
Issued 9 August 1985 Resolved
REINSTALL GUARDS ON BAIT PUMPS COUPLINGS IN ENGINE ROOM.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Lifesaving
Issued 9 August 1985 Resolved
NO NIGHTIME OPERATION UNTIL ALL JIM BUOY WATERLIGHTS ON P.F.D.'S ARE REPLACED.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Deck/Cargo
Issued 9 August 1985 Resolved
DOUBLE CLAMP HOSES AND SECURE MOTOR ON FORWARD BAIT PUMPS.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Accommodation/Occupational Safety
Issued 9 August 1985 Resolved
REMOVE GREASE FROM GALLEY VENT AND ENCLOSURE.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Electrical
Issued 9 August 1985 Resolved
CLOSE ELECTRICAL BOX IN GALLEY STORAGE ROOM.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Electrical
Issued 9 August 1985 Resolved
SECURE GALLEY CIRCUIT BOX COVER IN GALLEY.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.