MONTE CARLO

MONTE CARLO is a 1973 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in February 2026, along with 34 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 20 February 2026.

Built
1973
Last inspected
20 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 February 2026
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD6745
Flag
UNITED STATES
Maury page id
psix-47660

Documentation record

Registered dimensions (L × B × D)71.0 ft × 22.3 ft × 6.4 ft
Registered tonnagegross 86 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT N VILLEGAS JR · VENTURA, CA, UNITED STATES · built 1973
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN PEDRO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

20 February 2026 Deficiency Check · Annual Inspection · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8267680
22 January 2025 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8066841
14 January 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8009126
26 July 2024 Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7968144
14 December 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7806966
29 November 2023 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7806960
7 December 2022 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7577670
15 June 2022 Plan Review "T" Boat · Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7485387
8 March 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7407606
24 February 2022 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7405486
4 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7150251
2 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6919323
16 January 2020 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6881877
2 December 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6865837
14 November 2019 Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6855985
23 January 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6607416
2 January 2018 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6341795
12 December 2017 DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6306028
29 November 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6299220
29 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6314620
17 February 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6086250
26 February 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5811494
4 February 2016 Administrative Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5800780

Deficiency record · 34

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 February 2026 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Fwd engine room bulkhead centerline, and aft engine room bulkhead stbd side have bulkhead penetrations not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2026
Resolved 25 February 2026
Resolution: Attended vessel, viewed holes appropriately filled
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 February 2026 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Broken conduit found resting on wiring in freezer compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2026
Resolved 25 February 2026
Resolution: Attended vessel, conduit re-attached.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 February 2026 Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Wheelhouse breaker distribution panel door unable to remain closed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2026
Resolved 25 February 2026
Resolution: Attended vessel, magnet used to secure door.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 February 2026 Resolved
Spaces containing machinery shall be fitted with at least two ducts to furnish natural or mechanical supply and exhaust ventilation. Vessel has no installed ventilation ducts for the engine room. Submit E/R supply and exhaust ventilation installation plans for review and approval by the [name withheld] fixed ventilation as per OCMI approved plans. 46 CFR 182.20-45(c)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 April 2026
Resolved 10 April 2026
Resolution: Observed proper installation of ventilation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 February 2026 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a), vessels more than 65 ft require 02 fixed power bilge pumps (50 GPM). Vessel only has one fixed power bilge pump. Submit bilge pump installation plans for review and approval by the [name withheld] secondary power bilge pump as per OCMI approved plans. 46 CFR 182.520(a)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 April 2026
Resolved 10 April 2026
Resolution: Observed proper operation and installation of second power bilge pump
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 February 2026 Resolved
Machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads. E/R door leading to accommodation space is not vapor tight. 46 CFR 182.35-1(a)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2026
Resolved 10 April 2026
Resolution: Observed proper sealing of engine room door.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 February 2026 Resolved
There shall be a minimum of two fire hydrants on all mechanically propelled "L" vessels. One length of 1.5 in diameter, 50 ft length hose shall be provided at each fire hydrant. Vessel only has one 1.5 in diameter fire hose installed fwd. Submit aft fire hose installation plans for review and approval by the [name withheld] aft fire hose as per OCMI approved plans. 46 CFR 181.15-5
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 April 2026
Resolved 10 April 2026
Resolution: Observed proper installation and operation of aft fire hose station.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 February 2026 No resolution recorded
On a vessel on a protected or partially exposed route, a watertight coaming with a height of at least 6 inches must be provided under each weather tight door. Coaming height does not meet 6 inch requirement in each weather tight door entryway. 46 CFR 179.360(d)(1)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 April 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 February 2026 Resolved
Spanner wrenches must be provided where 1.5 in diameter firehose is required. Fwd and Aft fire station did not have required spanner wrench.46 CFR 181.310(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2026
Resolved 10 April 2026
Resolution: Observed 02 spanner wrenches for fire stations.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 February 2026 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Update emergency instructions to state E/R door to be closed in the case of E/R fire or before activation of E/R fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 10 April 2026
Resolution: Removed requirement as engine room door seals properly and ventilation installed
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 December 2023 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life float (25 pax) carried on board were faded and no longer vivid in color as designed by the manufacture, renew/replace life-floats/buoyant apparatus.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2024
Resolution: L/F repainted
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 14 December 2023 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Mark upper deck for maximum allowed passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2024
Resolution: 2nd deck marked
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 March 2022 Resolved
The EPIRB test (monthly) shall be logged or otherwise documented. The EPIRB test has not been logged since December 2021.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
Resolution: Operator submitted photo of log book in place with EPIRB test logged 8 MAR.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 March 2022 Resolved
If the life float does not have a painter attachment fitting, a means for attaching the painter must be provided by a wire or line that encircles the body of the device. Line was not wrapped around the body of the life float.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
Resolution: Operator provided photo of life floats with painter properly secured around body of float.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 March 2022 Resolved
Each distribution panel must be totally enclosed and of the dead front type. The galley distribution panel has two open spaces at the bottom of the panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
Resolution: Operator provided photo of switchboard with blanks installed in unused slots.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2021 Resolved
An adult lifejacket must be provided for each person carried on board the vessel. MI condemned one (01) Kapok lifejacket.
Action required: 10 - Deficiency Rectified
Due 4 March 2021
Resolved 4 March 2021
Resolution: O/O replaced with new approved lifejacket on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2021 Resolved
Each lifejacket must be marked with type I retroreflective material. MI found 7 Adult lifejackets requiring new retroreflective material.
Action required: 10 - Deficiency Rectified
Due 4 March 2021
Resolved 4 March 2021
Resolution: O/O applied new type I retroreflective tape to the required lifejackets on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 March 2021 Resolved
All vessel must have navigation lights that are in compliance with the applicable section of the International and Inland Navigation Rules. MI found stern light inoperable.
Action required: 10 - Deficiency Rectified
Due 4 March 2021
Resolved 4 March 2021
Resolution: O/O repaired stern light on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 December 2019 Resolved
Vessel failed to conduct drydock exam IAW COI
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2019
Resolved 21 January 2020
Resolution: Vessel conducted satisfactory hull exam for credit drydock.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 January 2019 Resolved
Prove proper operation of pre-engineered fire extinguishing system for the generator. Found light and audible alarm for shutdown inoperable at operating station.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2019
Resolved 23 January 2019
Resolution: Discrepancy corrected later the same day, to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2019 Resolved
Make freezer compartment/sonar compartment bulkhead watertight. Found space surrounding wire penetration on port side to be not watertight.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 23 January 2019
Resolution: This discrepancy was corrected prior to departure, to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2019 Resolved
Replace unservicable retroreflective marterial on 30 identified lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 23 January 2019
Resolution: This discrepancy was corrected prior to departure, to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 January 2019 Resolved
Replace plastic zip ties in sonar compsrtment and fuel tank compartment with metal supports. Found multiple runs of cable/wire to be supported to overhead beams with zipties.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2019
Resolved 30 January 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 January 2019 Resolved
Provide EPIRB log for monthly EPIRB testing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 23 January 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 12 December 2017 Resolved
PROVIDE PROOF OF SUPERVISOR TRAINING FOR EAP TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46CFR16.401(b)
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 2 January 2018
Resolution: Owner/Operator provided proof of Supervisory Training for EAP.
Lifesaving › Lifefloat › Capacity
Issued 12 December 2017 Resolved
PROVIDE AND INSTALL LIFE FLOAT TO ACCOMODATE 100% OF TOTAL PERSONS PERMITTED ON BOARD TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. TOTAL PERSONS REDUCED TO 75. 46CFR180.205(a)
Action required: 705 - Other - as specified
Resolved 12 December 2017
Resolution: OWNER PROCURED 15 PERSON LIFEFLOAT AND INSTALLED PROPERLY. TOTAL LIFEFLOAT CAPACITY: 90
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 12 December 2017 Resolved
PROVIDE 2 ADULT PFD'S. TOTAL PERSON COUNT REDUCED TO 84. ITEM #2 TAKES PRECEDENCE. 46CFR180.71(a)
Action required: 705 - Other - as specified
Resolved 12 December 2017
Resolution: OWNER PROCURED 2 NEW ADULT SIZED PFDS.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 February 2017 Resolved
Dead end wires in the lazerrete.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 22 February 2017
Resolution: Master removed all dead end wiring.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 February 2017 Resolved
Found multiple hose clamps missing on the overboard discharge lines for both MDE’s and SSDG’s
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 22 February 2017
Resolution: Master placed two hose clamps on all overboard discharge lines for both MDE’s and SSDG’s.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 February 2017 Resolved
Found lighting in the lazarrete to be inoperable and hanging from overhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 22 February 2017
Resolution: New LED lights were placed in the lazerrete
Fire Fighting › Fire Main › Pressure
Issued 17 February 2017 Resolved
Pressure gauge on the fire main system was not operating properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 22 February 2017
Resolution: New pressure gauge was placed on the fire pump
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 February 2017 Resolved
Found temporary type connectors on batteries in the lazerrete and tank room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 22 February 2017
Resolution: Permanent connections were placed on all battery installations
Lifesaving › Lifefloat › Float-free Link
Issued 17 February 2017 Resolved
Found float-free link for life floats improperly installed
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 17 February 2017
Resolution: Installed float free link properly
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 February 2016 Resolved
Complete a satisfactory hull exam with a Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2016
Resolved 12 February 2016
Resolution: Credit drydock conducted to the satisfaction of the attending Marine Inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.