03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 August 2019
Resolved
Watertight doors
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 August 2019
Resolved 9 October 2019
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 August 2019
Resolved
Vessel steering system was corroded and was not able to be tested at the time of the exam.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2019
Resolved 9 October 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 August 2019
Resolved
Machinery space bilges contained excessive oil and posed a pollution hazard.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2019
Resolved 9 October 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 August 2019
Resolved
Flammable material (paint) was located on the main deck and not properly secured/stored.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2019
Resolved 9 October 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 August 2019
Resolved
On the vessel bridge, electrical wiring was foind to be exposed and presenting a fire/shock hazard.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2019
Resolved 9 October 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 August 2019
Resolved
The fixed fire suppression sytem for the vessel's paint locker was disassembled and inoperative.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2019
Resolved 9 October 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 August 2019
Resolved
Required vessel charts and publications were missing and/or outdated.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2019
Resolved 9 October 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 August 2019
Resolved
Batteries for vessel emergency radios were missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2019
Resolved 9 October 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 August 2019
Resolved
Emergency lighting aboard the vessel interior and exterior was inoperative.
Due 23 September 2019
Resolved 9 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 August 2019
Resolved
The majority of fire/smoke detection in vessel accomodation spaces was inoperative.
Due 23 September 2019
Resolved 9 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 August 2019
Resolved
Vessel primary lifesaving had not been properly serviced and was in visibly poor condition.
Due 23 September 2019
Resolved 9 October 2019
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 14 August 2019
Resolved
Vessel EPIRB registration was missing and not able to be verified.
Due 23 September 2019
Resolved 9 October 2019
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 14 August 2019
Resolved
Improper use of the Marine Sanitation Device (MSD), using a voind space as a holding tank and the MSD's treatment cent was leaking.
Due 23 September 2019
Resolved 9 October 2019