← All vessels
BALTIC HEATHER
BALTIC HEATHER is a 1998 freight ship. The Coast Guard has recorded 27 inspections since 1998, most recently in August 2024, along with 13 deficiencies and 1 operational control.
Records from 1998 to 2024. Most recent: inspection, 26 August 2024.
- Built
- 1998
- Last inspected
- 26 August 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9181144 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6EQ7
476754
Flag
BAHAMAS, THE
—
Maury page id
psix-476754
Inspections, by type
…with no type recorded8
Years with a record
13 calendar years (1998–2024)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it10114 - Dead Weight, Ton
9859 - Convention (Subpart B), Gross Ton
15845 - Displacement, Ton
5124 - Convention (Subpart B), Net Ton
9859 - Convention (Subpart B), Gross Ton
15845 - Displacement, Ton
5124 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
26 August 2024
PSC A · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7987013
5 December 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7604151
5 November 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7346159
1 November 2021
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7342045
10 March 2021
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7153359
27 December 2020
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7118607
15 September 2020
PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7054422
14 September 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7054134
14 September 2020
COE-Offshore
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7056036
20 March 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6646262
13 November 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6308812
1 June 2012
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4329670
30 May 2012
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4328382
29 June 2008
ISPS II Exam · PII Safety Exam · Administrative Inspection · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3244105
29 June 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3251062
23 October 2006
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2806717
18 July 2006
Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2717526
7 March 2006
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2597717
14 December 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2551489
8 June 2005
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2384047
14 February 2005
Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2292161
14 February 2005
ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2292583
16 January 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286000
13 December 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 527219
13 January 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 424361
10 January 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 424418
17 December 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 423831
Deficiency record · 13
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 August 2024
Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity prescribed in table 44.1 for galley spaces must be A-0. Galley doors gaskets where not suitable to prevent the passage of smoke and flame.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 5 December 2022
Resolved
A self-contained emergency source of electrical power shall be provided. During exam emergency generator was unable to start. 74SOLAS(04)II-I/43.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 December 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation. PSCO indentified multiple patches and temporary repairs in ships engine room. Areas include sewage piping and cooling line throughout engine room. 74SOLAS(20)I/11
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 1 November 2021
Resolved
CG006 - BALTIC HEATHER, of keel laid date 03DEC1997 and ballast water capacity of 943 m3, is past its compliance date per the implementation schedule in 33 CFR 151.2035(b). Vessel’s current ballast water management method is exchange and discharge, which is not authorized. Vessel has no BTWS installed. Vessel is not authorized to discharge untreated ballast into U.S. waters.
This deficiency will not be cleared until CG examiners receive documentation that the vessel has installed a BWTS, has decided to use on public water from the U.S. public water system, or has updated its ballast water management plan to state that the vessels ballast water management method in U.S. waters is no discharge. - CFR 33 151.2035 - 15c
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 15 September 2020
Resolved
The ring, line and letters shall be painted in white or yellow on a dark background. Deck line was not painted white or yellow on a dark background.
ICLL 66 Annex 1 Reg 8 - 40ac
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 1 June 2012
Resolved
74SOLAS (1997 Consolidated) CH II-2/ 13.1.12
Suitable instructions and components spares for testing, and maintenance shall be provided.
[name withheld] was unable to provide adequate non-flammable detector tester.
[name withheld] provided approved non-flammable detector tester before exam completion.
Engineering
Issued 17 December 1998
Resolved
PROVIDE PROPER FUEL OIL CONTAINMENT TO NO.4 FUEL OIL TANK VENT STARBOARD SIDE. CONTAINMENT IS OF INSUFFICIENT SIZE. (33 CFR 155.30)
Lifesaving
Issued 17 December 1998
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILL TO SATISFACTION OF USCG PRIOR TO LEAVING THE PORT OF SAN JUAN.
Fire Fighting
Issued 17 December 1998
Resolved
PROPERLY MARK CO2 ROOM TO CO2 BOTTLE STORAGE ROOM.
Fire Fighting
Issued 17 December 1998
Resolved
PROVIDE A KEY READILY AVAILABLE TO CO2 STORAGE ROOM OUTSIDE THE SPACE IN A BOX WITH A BREAKABLE GLASS.
Lifesaving
Issued 17 December 1998
Resolved
PROPERLY STOW LIFEBOUYS WITHSMOKE AND LIGHT SIGNALS ON PORT AND STARBOARD BRIDGE WINGS.
Fire Fighting
Issued 17 December 1998
Resolved
PROPERLY LABEL SPRINKLER ACTIVATION VALVE TO PAINT LOCKER.
Construction/Loadline
Issued 17 December 1998
Resolved
REPAINT LOADLINE MARK IN CONTRASTING COLOR TO SHIP'S HULL. ILLC 66 ANNEX 1/8.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.