MAURY USCG vessel records Sign in
← All vessels

NARIVA

NARIVA is a 1998 tank ship. The Coast Guard has recorded 30 inspections since 1998, most recently in May 2014, along with 4 deficiencies and 4 operational controls.

Records from 1998 to 2014. Most recent: inspection, 22 May 2014.

Built
1998
Last inspected
22 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9172715 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
476756
Flag
BAHAMAS, THE
—
Maury page id
psix-476756

Inspections, by type

…with no type recorded15
Years with a record 14 calendar years (1998–2014)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it20573 - Convention (Subpart B), Gross Ton
37686 - Convention (Subpart B), Net Ton
30977 - Dead Weight, Ton
38914 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

22 May 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4864230
8 May 2014 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4848690
18 January 2012 PII Safety Exam · ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4220354
15 August 2011 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4116440
1 December 2010 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3902325
5 January 2010 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3658969
16 October 2008 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3342283
13 March 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3163985
12 March 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3163333
11 March 2008 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3162576
9 March 2008 ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3160048
7 March 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3160143
4 April 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2901722
23 August 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2757328
22 August 2006 Ballast Water Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2756317
21 August 2006 COC-CHEM Renew
Type not classified · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2754875
13 January 2006 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2566536
3 October 2005 ISPS II Exam · COC-CHEM Annual
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2506993
4 August 2005 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2451580
27 August 2004 ISPS II Exam · COC-CHEM Renew
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2177664
6 June 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1810934
2 May 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1786358
23 October 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 52171
1 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 294191
1 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1073670
11 September 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 282118
11 September 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1053660
11 September 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1043052
5 September 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 420094
5 September 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 800579

Deficiency record · 4

Deck/Cargo › Inert Gas System › Venting System
Issued 8 May 2014 Resolved
1835 - Cargo Venting - the vent outlets of a controlled tank venting system shall be arranged at a height of not less than 6 m above the weather deck if they are not highvelocity. The ship's current tank venting arrangement consists of two common venting valves that are 3.25 m from the top of the cargo tank. The flowrate graph for the valves appears to show that the valves vent at only 7.5m/s.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 May 2014
Resolution: Received documentation from the Classification society stating that the tank venting system on the weather deck were equiped with high velocity valves
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 1 December 2010 Resolved
vessel's visual overfill alarm was not working on cargo deck; must be rectified prior to cargo loading [33CFR155.480(b)(2)(i)]
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2010
Resolved 1 December 2010
Resolution: vessel''''''''s visual overfill alarm is now operating and is visible from cargo deck
Lifesaving › Lifeboat Equipment › Food Ration
Issued 1 December 2010 Resolved
06 of the required food rations were no longer air tight. SOLAS 74 (consold 97) Ch 3 reg 41.8.12
Due 8 December 2010
Resolved 2 December 2010
Resolution: Received receipt of food ration delivery to vessel for the lifeboat.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 1 December 2010 Resolved
each lifeboat is missing 30 liters of fresh water. SOLAS 74 (consold ed 97) Ch 3 Reg 41.8.9
Due 8 December 2010
Resolved 2 December 2010
Resolution: Received receipt of water delivery to vessel for the lifeboat

Ownership record