MAURY USCG vessel records Sign in
← All vessels

OLGA

OLGA is a 1996 freight ship. The Coast Guard has recorded 28 inspections since 1998, most recently in August 2014, along with 12 deficiencies and 7 operational controls.

Records from 1998 to 2014. Most recent: inspection, 29 August 2014.

Built
1996
Last inspected
29 August 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9109548 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
476758
Flag
LIBERIA
—
Maury page id
psix-476758

Inspections, by type

…with no type recorded15
Years with a record 13 calendar years (1998–2014)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it11121 - Convention (Subpart B), Gross Ton
6859 - Convention (Subpart B), Net Ton
23100 - Displacement, Ton
18796 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

29 August 2014 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4963179
12 December 2011 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4202215
1 October 2010 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3861415
28 September 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3858931
27 September 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3854946
9 March 2009 MARPOL Annex VI Survey · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3427182
7 March 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3429349
11 January 2008 PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3125569
7 November 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3095053
27 September 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3064137
15 February 2007 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2872675
4 January 2007 PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2849903
17 April 2005 MARPOL Annex V Examination · NPV Safety Exam · MARPOL Annex I Examination · ISPS III Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2332383
1 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2251505
25 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2247907
8 October 2004 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2216121
7 May 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2061819
11 March 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2022902
20 January 2004 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1988747
17 January 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1987411
14 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1690724
15 February 2002 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1486962
16 March 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 288177
10 May 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 277632
19 September 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 432938
13 July 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 430344
23 May 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 428881
11 November 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 422406

Deficiency record · 12

Documentation › Certificates/Documents › IOPP Certificate
Issued 12 December 2011 Resolved
2230 - Documentation - The government of a party to the present convention may at the request of the administration, cause a ship to be surveyed. PSCO observed that the endorsement required for maximum throughput for the oily water separator was missing from the IOPP Form A. Request clarification to the existing endorsement.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 December 2011
Resolved 10 August 2012
Resolution: PSCO Reviewed corrected IOPP certificate.
Fire Fighting › Nozzles › Type
Issued 28 September 2010 Resolved
All nozzles shall incorporate a shutoff. One nozzle in lower engine room/deck flat was a straight tube design and did not incorporate a shutoff. Solas 97 Con Ch II-2.4.8.4
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 28 September 2010
Resolution: Vessel replaced straight tube design nozzle with a nozzle incorporating a shutoff. Deficiency was corrected on the spot.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 28 September 2010 Resolved
Deck line shall be painted in white or yellow on a dark ground permanently marked deck line painted black on black background. ILLC Ch I Reg 8
Action required: 705 - Other - as specified
Due 5 October 2010
Resolved 1 October 2010
Resolution: Received, reviewed, and accepted proper documentation stating the deficiency was rectified. The documentation stated the deck line was painted in a contrasting color.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 28 September 2010 Resolved
Food rations hsall be kept in airtight packaging. Found 01 food rations not airtight in starboard lifeboat. Solas 04 Con CH III Reg 31.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 28 September 2010
Resolution: Vessel replaced 01 food rations found not airtight with 01 airtight food rations in the starboard lifeboat.
Engineering › Steam System (main) › Piping
Issued 9 March 2009 Resolved
Steam line for Main Engine Fuel Oil heater found to be significantly wasted and leaking steam, creating burn hazard to engine room personnel.
Action required: 705 - Other - as specified
Due 16 March 2009
Resolved 17 March 2009
Resolution: Steam line repaired to the satisfaction of class.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 March 2009 Resolved
Numerous soft patches found on sea water cooling system.
Action required: 705 - Other - as specified
Due 23 March 2009
Resolved 17 March 2009
Resolution: All pipes repaired to the satisfaction of class.
Engineering › Fuel Oil Service System › Piping
Issued 11 January 2008 Resolved
All of the double jacket covers for the Fuel Oil lines on the M/E are incomplete and do not cover all of the Pipes. Therefore the vessel is not in compliance with SOLAS Chap 11-2 Reg 4.2.2.5.2.Provide class documentation attesting to compliance with regulation. Make all repairs to the satisfaction of the attending classification society.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 25 January 2008
Resolution: Received, reviewed and accepted class report from GL stating that the Fuel Oil lines have been brought into compliance with with SOLAS regulations and approved by class. This satisfies the above requirement.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 11 January 2008 Resolved
During the inspection of the starboard side life boat, the PSCO found that 07 of the 25 required food rations have lost their vacuum seal. Replace the defective rations to satisfaction of the certificate issuing authority.
Action required: 705 - Other - as specified
Due 18 January 2008
Resolved 14 January 2008
Resolution: Received, reviewed & accepted a class report from [name withheld] attesting to the replacement of the defective rations in the starboardside lifeboat. This satisfied the above requirement.
Engineering › Fuel Oil Service System › Piping
Issued 4 January 2007 Resolved
Repair steam leak in fuel oil piping system.
Action required: 705 - Other - as specified
Due 5 January 2007
Resolved 15 February 2007
Resolution: Received proper documentation from vessel satisfying requirement.
Navigation
Issued 16 March 2001 Resolved
VESSEL'S RUNNING LIGHTS WERE NOT OPERATING CORRECTLY. VESSEL HAD MADE TEMPORARY REPAIRS TO THE LIGHTS AWAITING THE ARRIVAL OF PROPER PARTS TO COERRECT ISSUE. VESSEL WAS ADVISED TO HAVE CLASS SOCIETY ADDRESS THE ISSUE AND STATE WHETHER OR NOT REPAIRS WERE SATISFACTORY.
Condition: Unknown
Due 18 March 2001
Resolved 22 March 2001
Lifesaving
Issued 16 March 2001 Resolved
VESSEL COULD LOWER STBD LIFEBOAT AT THE TIME OF THE DRILL. VESSEL WAS TO HAVE CLASS ADDRESS THE ISSUE. IAW SOLAS 74/78 CHIII REG 48.1.1
Condition: Unknown
Due 18 March 2001
Resolved 22 March 2001
Lifesaving
Issued 16 March 2001 Resolved
4 OF THE VESSELS RATIONS WERE NOT SEALED CORRECTLY. VESSEL IS TO REPLACE RATIONS PRIOR TO DEPARTURE. IAW SOLAS 74/78 CHIII REG 41.1.1
Condition: Unknown
Due 18 March 2001
Resolved 22 March 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.