Records from 1999 to 2011. Most recent: inspection, 2 February 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
2 February 2011
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3937864
26 February 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3419638
2 February 2007
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2864071
14 August 2006
ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2747893
9 October 2004
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2217171
26 March 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2031925
1 March 2004
MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2010939
22 September 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1909948
20 January 2003
Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1731030
14 March 2002
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1493750
28 January 2002
Passenger/Freight Vessel Examination
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1481946
19 July 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 20873
12 July 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 291872
26 October 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 282928
8 October 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 433360
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 26 February 2009
Resolved
The vessel had no hydrostatic test records for fuel and lube oil piping as required by 33CFR155.820. Vessel is prohibited from taking bunkers in US waters until a test has been conducted IAW 33CFR156.170.
Action required: 703 - Prior to bunkering operations
Due 26 February 2009
Resolved 26 February 2009
Resolution: Received proper documentation from Master stating that inspection and hydrostatic test of bunkering equipment had been completed, satisfying requirement.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 8 August 2006
Resolved
3050 Anchor (port-side) left down with no coverings or watch. Access to the ship compromised.
Solas 2004 Chapter II-2, Regulation 4.2 / ISPS Part A 7.2.2
10c
Action required: 705 - Other - as specified
Due 8 August 2006
Resolved 8 August 2006
Resolution: 10c. Deficiency Rectified to the satisfaction of the Coast Guard.
Deck crew brought the anchor up before we left.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 August 2006
Resolved
0750 Three doors in the main stairway and 3 doors in the galley A-60 zone not closing properly. Galley door is tied back.
SOLAS 1997 Chapter II-2 Reg 30.4.1
70A
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 February 2007
Resolution: Received class report from NKK satisfying requirement.
Pollution Prevention/Response › Prevention Equipment
Issued 1 March 2004
Resolved
Repair as original the refractory inside the incinerator where fractured. MARPOL 73/78 I
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 March 2004
Resolution: Class provided proof of repair to bring incerator into compliance.
Engineering › Fuel Oil Service System
Issued 1 March 2004
Resolved
Provide protection in way of oil fuel lines to avoid oil spray or leakage onto hot surfaces. SOLAS 74 amd II-2 /15.9-11 LEGACY COMPONENT DESC: Piping
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 March 2004
Resolution: Class provided proof that the iol fule lines in question are now protected by FN tapes.
Engineering › Bilge Water Management System
Issued 1 March 2004
Resolved
Install blank, in pipe that leads from the bilge pump to overboard. MARPOL 73/78 17(3) LEGACY COMPONENT DESC: Pump
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 March 2004
Resolution: Class provided proof of permanent installation of a blind flange to bring OWS into compliance.
Fire Fighting › Firemans Outfit
Issued 28 January 2002
Resolved
Firemans Outfit in poor condition. LEGACY COMPONENT DESC: Protective Clothing
Due 28 February 2002
Resolved 14 March 2002
Navigation › Piloting/Steering
Issued 28 January 2002
Resolved
Tidal current tables missing. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 14 March 2002