Records from 1998 to 2025. Most recent: inspection, 1 June 2025.
Inspection history · 47
1 June 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8149038
15 January 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8064065
26 December 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8051018
16 November 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8034983
1 August 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7972277
1 August 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7972505
1 August 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7975304
5 February 2024
PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7860079
5 December 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7833790
2 December 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7832626
29 November 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7831164
31 July 2023
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7756732
19 October 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6025402
22 September 2016
PI Safety Exam · ISPS III Exam · Ballast Water Examination · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6007037
8 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5849849
7 April 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5849553
27 February 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5823090
10 February 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5812881
2 March 2014
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4808566
22 July 2012
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4386241
25 June 2012
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4356212
19 January 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4228617
21 December 2011
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4209718
13 December 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3909054
20 September 2010
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3853618
20 January 2010
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3666866
24 December 2009
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3654945
24 December 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3659408
9 December 2009
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3646797
9 December 2008
ISPS II Exam · NPV Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3376698
11 November 2008
ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3360543
5 October 2008
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3338827
1 April 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3175078
18 March 2008
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3166719
29 January 2008
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3137398
29 October 2007
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3089259
17 October 2007
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3081445
11 October 2007
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3077627
21 July 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3002424
13 April 2007
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2908294
10 April 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2905574
2 March 2007
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2880462
1 March 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2879721
1 February 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2865739
19 January 2007
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2858408
27 May 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 429224
13 June 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 416726
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2024
Resolved
Under all sailing conditions, including maneuvering, the speed, direction of thrust and, if applicable, the pitch of the propeller shall be fully controllable from the navigation bridge. Sector Miami was notified that the vessel was unable to direct thrust from the navigation bridge and suffered a loss of propulsion.
74SOLAS(2004 CONS.) CH II-1 REG. 49.1
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 August 2024
Resolved 17 October 2024
Resolution: CLASS REPORT.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 22 September 2016
Resolved
whenever an accident occurs to a ship which affects the safety of the ship, the master/owner shall report to admin or RO who shall cause investigation. The main engine suffered crankcase overpressurization causing crankcase safety covers to release. Chief Engineer shut down maine engine, assist tugs returned vessel to dock. Provide class and technician reports prior to movement. Solas74(14) I/11c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2016
Resolved 2 December 2016
Resolution: Class conducted satisfactory sea trials, CG received report of class to clear From B.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 April 2016
Resolved
1530-All ships of 3000 gross tonns and upwards shall have a 3GHz or, where appropriate by the administration, a second 9GHz radar which are functionally independent of each other. Vessel's secondary radar is inoperable. 74SOLAS(14)Ch. V/Reg. 19.2.7.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 April 2016
Resolved 21 April 2016
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 February 2016
Resolved
Each vessel of 10,000 gross tonnage or more must have, in addition to the radar system under 33 CFR 164.35(a), a secondary marine radar system that operates independently of the first. Vessel's X-Band radar is not capable of operating independently.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2016
Resolved 10 February 2016
Resolution: Received tech report attesting to correction of the deficiency.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 24 December 2009
Resolved
While manuevering into Port Everglades, vessel lost power due to the operation of the bow thruster. Have class attest that electrical generators can take load and maintain ship in normal operation. Electrical generators shall maintain ship in normal operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2009
Resolution: Received class survey report attesting that genertors can take load.
Electrical › Electrical Distribution System (service) › Conductor
Issued 24 December 2009
Resolved
Captain claimed the power failure was due to condensation in the relay contact. Electrician cleaned contact. Have class attest to its proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2009
Resolution: Received class survey report attesting to proper repair.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 January 2008
Resolved
Ship not provided with recent testimony of proper calibration of oil content meter. Ship not provided with simple means to check on instrument drift, and to confirm the accuracy and repeatability of the instrument reading. MARPOL 2006 Consol. I / 14.7; MEPC 60(33) 4.2.8. To satisfaction of Administration.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 March 2008
Resolution: Received attached Reports (GLDEFS) from class stating the rectification of the deficiency.
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 29 January 2008
Resolved
Load line marking not permanently marked. Recognized Organization "GL" marking not stamped, punched, or otherwise permanently marked.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 18 March 2008
Resolution: Received attached Reports (GLDEFS) from class stating the rectification of the deficiency.
Navigation › Piloting/Steering › Gyro Compass
Issued 21 July 2007
Resolved
Vessel issued LOD to depart Port of Miami and to have repairs made to gyro-compass repaired prior to next U.S. Port.
Action required: 15 - Rectify deficiencies by next port
Due 21 July 2007
Resolved 18 October 2007
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 19 January 2007
Resolved
Provide additional PFD's for forward liferaft. SOLAS 78 III.7.2.2
Action required: 705 - Other - as specified
Due 26 January 2007
Resolved 29 October 2007
Resolution: Report recieved from flag state. Deficiency cleared. 00 deficiencies remain outstanding.