Records from 1998 to 2016. Most recent: inspection, 24 June 2016.
Inspection history · 49
24 June 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5911813
15 April 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5854787
28 May 2014
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4872095
17 July 2009
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3537203
28 April 2009
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3462767
27 April 2009
MARPOL Annex V Examination · Ballast Water Examination · ISPS III Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3461788
24 April 2009
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3459869
27 October 2008
MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3352353
3 October 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3337780
11 September 2008
Deficiency Check · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3322346
11 September 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3322942
19 February 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3148169
7 June 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2954127
30 January 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2864096
27 September 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2788395
15 April 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2625308
18 February 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2587730
22 January 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2570862
18 October 2005
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2516862
21 July 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2434880
23 June 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2400720
2 May 2005
PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2347782
23 November 2004
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2247001
9 November 2004
PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2237497
28 August 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2179016
26 August 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2177160
5 July 2004
ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2122300
23 April 2004
Annual Inspection · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2051021
13 April 2004
MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2043596
3 February 2004
Periodic Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1999371
16 December 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1964821
28 October 2003
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1938545
23 September 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1910768
22 April 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1778611
5 February 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1740202
2 January 2003
Ballast Water Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1725175
2 May 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1613721
4 April 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1601374
15 November 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 295567
28 June 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 474446
25 May 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 290532
10 May 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 289917
1 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 278379
27 January 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 104451
27 January 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395350
13 January 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 273573
17 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 429715
27 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 424911
1 July 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 417357
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 24 June 2016
No resolution recorded
The condition of the ship or it's equipment does not correspond substantially with the particulars of the certificate. The incinerator failed to extinguish it's flame during a flameout test of the incinerator. 74SOLAS (14Cons)Ch. 1 Reg 6(c) 40A
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Deck/Cargo › Mooring/Anchoring › Winch
Issued 27 April 2009
Resolved
Leak in hydraulic line in way of port side anchor windlass.
Action required: 705 - Other - as specified
Due 11 May 2009
Resolved 28 April 2009
Resolution: Received class report attesting to satisfactory repair. Deficiency cleared.
Lifesaving › Lifeboat Equipment › Rocket Parachute Flare
Issued 27 April 2009
No resolution recorded
Vsl not able to provide 10 handflares and 06 rocket parachute flares for their lifeboats. Provide pyrotechnics and have stowage/inventory for lifeboat equipment reviewed/approved by class prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Received fax report from class attesting to the supply of handflares and rocket parachute flares. Deficiency cleared.
Construction/Loadline › Markings › Load Line Mark
Issued 27 April 2009
Resolved
Port side Plimsol marking is not of contrasting color to the hull.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 19 May 2009
Resolution: Both sides of Load Line Markings painted in contrasting color to hull color.
Construction/Loadline › Structures › Deck Plating
Issued 27 April 2009
Resolved
Port side lashing stages for bays 34, 42, and 50 are warped from strain.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 19 May 2009
Resolution: The buckled port side lashing stages for Bays # 26, 42 and 50 were completely replaced and bay #34 support stages was renewed with support stages. All replaces stages were found to be in good condition.
Engineering › Steering Gear System › Pump
Issued 27 April 2009
Resolved
Hydraulic leak in way of #2 steering gear pump.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 28 April 2009
Resolution: Received class report attesting to satisfactory repair and operational test of steering gear. Deficiency cleared.
Engineering › Fuel Oil Service System › Pump
Issued 27 April 2009
Resolved
Oil leakage of mechanical switch to F.O. booster pump in way of purifier space.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 28 April 2009
Resolution: Received class report attesting to satisfactory repair and operational test. Deficiency cleared.
Personnel › Training › Fire Fighting Basic
Issued 11 September 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2008
Resolved 12 September 2008
Resolution: Conducted satisfactory fire drill.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 11 September 2008
Resolved
1705; The local contact numbers were not added to Annex 2, of the plan. As per section 2.4.2, of the plan local contact numbers to be used in case of an emergency need to be added to this section. The crew failed to keep this plan up to date. Corrections to this plan need to be verified by Class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Item was corrected to the satisfaction of Class.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 11 September 2008
Resolved
2120; The ship has two Garbage Plans on board. The ship's operators and Class need to decide which one the ship's crew will follow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Item was corrected to the satisfaction of Class.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 11 September 2008
Resolved
0750; Accommodation / E/R doors do not close properly, vent closures to forward hydraulic room missing securing devices, international shore connection not ready for use, monthly checks of portable fire extinguishers not being carried out, checking of smoke detection system questionable, general housekeeping in E/R needs improvement, Class must address these items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Item was corrected to the satisfaction of Class.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 11 September 2008
Resolved
2535; The [name withheld] posted in the Engine Control Room have not been updated since 2005. As per the Ship's Safety Management System if they are required they need to be updated and posted. If not, then they need to be removed. This must be addressed by Class / Flag Representative.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Item was corrected to the satisfaction of Class.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 11 September 2008
Resolved
2510; The [name withheld] is no using the required ballast water handling log form. He is using one that was made by another [name withheld], which has not been approved by the company. In addition he has not documented anything regarding sediment as required by the plan. These items must be addressed by Class / Flag representative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Item was corrected to the satisfaction of Class.
Construction/Loadline › Structures › Manhole
Issued 11 September 2008
Resolved
0940; The manhole cover for the fuel oil drain tank located in the engine room has been held in place by only three of the required 24, nuts to keep it tightly sealed. According to the C/E this has been like this for approximately 1, month. Advised Master and C/E of the safety concerns about operating the ship in this matter and hazards it presents for the safety of the crew and vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2008
Resolved 11 September 2008
Resolution: Plat was properly installed prior to USCG inspectors departing the vessel.
Fire Fighting › Ventilation Systems › Ducts
Issued 11 September 2008
Resolved
0510; The vent ducting located in the forward hydraulic room port side has a hole in it that was covered with tape and painted over. Other parts of the vent have a number of pin holes that are showing signs of leakage through these holes and into the space. Item must be inspected and repaired to the satisfaction of Class / Flag representative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Item was corrected to the satisfaction of Class.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 11 September 2008
Resolved
0950; Electrical items noted that need attention, remove jumper wiring from overhead lights outside of hydraulic room, reattach wire leading to light at lower level of bow thruster room, provide documentation that the electrical matting is approved for use around electrical panels and installed approved matting around panels where its missing. Items need to be addressed by Class and Flag Rep.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Item was corrected to the satisfaction of Class.
Engineering › Steam System (main) › Piping
Issued 11 September 2008
Resolved
0599; The #2, tank has shifted forward and is missing 3, of the bolts that hold it in place. In addition someone installed a brace on the inboard side to support the tank and they have installed a large turnbuckle to keep it form moving as well. There isn't any documentation on board to show when this happened or if it was approved of by Class. Class must inspect system and advise.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Item was corrected to the satisfaction of Class.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 11 September 2008
Resolved
0599; Two of the batteries for the lifeboats had failed and were replaced. The 3rd Officer placed these in his lifesaving locker instead of tanking them to the dedicated hazardous waste locker. They have been in this locker for approximately 6, months. He failed to show an understanding for hazardous waste disposal requirements as required by the Ship's Garbage Plan.
Action required: 705 - Other - as specified
Due 11 September 2008
Resolved 11 September 2008
Resolution: Both batteries were taken to the hazardous waste locker under the direction of the [name withheld] (Environmental Officer).
Engineering › Freshwater Generation System › Piping
Issued 11 September 2008
Resolved
1499; In the E/R the following items were noted; cracks around the door frames leading to the ships service generators, soft patches on the fresh water generator salt water supply line and ejector pump and soft patches on the fuel oil purifier drain lines. No non-conformity reports have been submitted to the company and the Master was unaware of these. Class must inspect and advise.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Item was corrected to the satisfaction of Class.
Lifesaving › Immersion Suits › General
Issued 11 September 2008
Resolved
0663; Four of the immersion suits were too large for crewmembers. Suits must be of an appropriate size for the crewmembers to properly wear. This needs to be addressed by Class and Flag representative, SOLAS 74 AM III / 32.3.2.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Item was corrected to the satisfaction of Class.
Lifesaving › Inflatable Liferafts › Container Construction
Issued 23 November 2004
Resolved
All inflatable liferafts have bolts installed through their casing. Bolt installations must be verified by class and forwarded via fax to Port State Control San Francisco.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 29 November 2004
Resolution: 29NOV2004: Received faxed description of liferaft casing bolts from manufacturer. Vessel no longer has outstanding requirements.