← All vessels
THOR WAVE
THOR WAVE is a 1998 freight ship. The Coast Guard has recorded 36 inspections since 2000, most recently in March 2016, along with 20 deficiencies and 10 operational controls.
Records from 2000 to 2016. Most recent: inspection, 4 March 2016.
- Built
- 1998
- Last inspected
- 4 March 2016
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 20 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9139775 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HSDT2
476835
Flag
SINGAPORE
—
Maury page id
psix-476835
Inspections, by type
…with no type recorded20
Years with a record
13 calendar years (2000–2016)
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it49213 - Displacement, Ton
39042 - Dead Weight, Ton
25889 - Convention (Subpart B), Gross Ton
12179 - Convention (Subpart B), Net Ton
39042 - Dead Weight, Ton
25889 - Convention (Subpart B), Gross Ton
12179 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 36
4 March 2016
Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5789455
3 March 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5826262
3 October 2014
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 4998461
21 May 2014
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4864191
8 May 2014
Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4853393
27 February 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3703338
25 January 2010
PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3669745
25 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3672571
25 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4150622
7 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3657497
7 January 2010
Type not recorded
No type recorded · USCGC PELICAN (WPB 87327) · USCG Heartland District (CGD-H) · Activity 3670906
1 January 2010
Ballast Water Examination · NPV Safety Exam · MARPOL Annex VI Survey · MARPOL Annex I Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3657496
10 March 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3621866
9 March 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3623224
7 March 2009
MARPOL Annex V Examination · ISPS I Exam · NPV Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3423675
25 February 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3423673
7 September 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3319525
3 September 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3317270
29 April 2008
MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3191149
15 October 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3080337
27 September 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3067573
4 July 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2982998
3 July 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2981576
20 March 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2891251
15 March 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2888674
13 March 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2892031
9 March 2007
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2884751
11 March 2006
ISPS II Exam · PII Safety Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2600337
12 March 2005
ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2308784
21 January 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1991962
2 November 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1940442
22 July 2003
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1876434
1 September 2002
Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1666772
6 November 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 295323
31 August 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 293345
22 May 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 278115
Deficiency record · 20
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 4 March 2016
Resolved
1581 - Rudder Angle Indicator - The main steering gear and rudder stock shall be: capable of putting the rudder over from 35 degrees on one side to 35 degrees on the other side . PSCO observed that rudder could only travel to 30 degrees port, and that actual rudder varied by 9 degrees when ordered 30 degrees starboard from helm position. 74 SOLAS (2004 am) II-1/29.3
Navigation › Piloting/Steering › Notices to Navigation
Issued 4 March 2016
Resolved
1030 - Steering Gear Alarm - Any main and auxiliary steering gear control system operable from the navigation bridge shall in the event of a failure of electrical power give and audio and visual alarm. PSCO noted that an audible alarm did not sound upon loss of power test. 74 SOLAS (2004 am) II-1.29.8
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 14 May 2014
Resolved
After the survey of the ship, no changes shall be made in the equipment and other items covered by the survey without sanction of the Administration. During fire drill PSCO noted that two fireman outfits were not serviceable.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 14 May 2014
Resolved
"A" class division shall be so constructed as to be capable of preventing the passage of smoke and flame to the end of the one-hour standard fire test. Vessel had "A" class door in galley with several holes drilled through it.
Engineering › Feedwater/Condensate Water System › Piping
Issued 14 May 2014
Resolved
After the survey of the ship, not changes shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without sanction of the Administration. Multiple soft patches were found on the fresh water holding tank piping.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 14 May 2014
Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the shop or persons on board. During inspection of incinerator notice multiple error messages on display screen. While performing operational test noted fuel pouring from heating unit.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 May 2014
Resolved
Oil filtering equipment shall be of a design approved by the administration and shall be such as will ensure that any oily water mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. During test of OWS sensor immediately went to higher than 30ppm. After resetting system 5 times meter would not drop below 23ppm.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 May 2014
Resolved
Provisions shall be made to facilitate cleaning, inspection and maintenance of main propulsion and auxiliary machinery including boilers and pressure vessels. Excessive fuel/oil pooled under generators and lagging saturated with fuel/oil throughout engine room.
Engineering › Steering Gear System › Power Unit
Issued 14 May 2014
Resolved
All steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of class. Upon testing the #1 steering gear pump, excessive vibrations/shuttering occurred when shifting the rudder to starboard. Vibrations increased in severity the longer the pump was engaged to starboard.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 25 January 2010
Resolved
1499-Engineering: The shaft seal is leaking excessive water into engine room bilges.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 1 January 2010
Resolved
0735- Personal equipment- firefigthing - During the fire drill the PSCO noted that one fire fighter's breathing apparatus had no low air alarm. The second breathing apparatus had a faulty supply value. Neither are operating as designed. Have both units serviced and provide third party documentation to the Coast Guard attest to their proper function. FSS code Ch 3.2
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 1 January 2010
Resolved
0750-Fire Prevention - Structural fire protection on third level of forward engine room bulkhead is deteriorated and no longer providing the level of protection required in a machinery space. Ensure insulation is restored to original configuration. 78 SOLAS 2004 cons. Ed Ch II-2/Reg 9
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 7 September 2008
Resolved
The vessel lost its Port Side Anchor due to wind and current caused by Hurricane Gustav.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 4 July 2007
Resolved
Vessel acquired an Inop Arpa while transiting the Lower Mississippi River
Engineering › Steering Gear System › Rudder
Issued 20 March 2007
Resolved
Rudder damage discovered in NOLA. Require a final damage assessment and proposal for final repairs prior to departure.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 March 2006
Resolved
Vessel's main engine and AUX engine sea water cooling system ahas a small <1" crack. Vessel is to make temporary repairs to the satisfaction of class prior to departure of the port of New London CT
Engineering
Issued 31 August 2001
Resolved
PRESENT FUEL OIL TRANSFER PUMP LACKS PROPER OPERATING COOLING FAN. AS PER SOLAS 74 I/II
Fire Fighting
Issued 31 August 2001
Resolved
ENSURE LOWER ENGINE ROOM ESCAPE TRUNK DOOR IS OPERATING PROPERLY. AS PER SOLAS 74 II-2/46-47.
Engineering
Issued 31 August 2001
Resolved
REPAIR LEAKING STEAM PIPING IN THE ENGINE ROOM AND NEAR THE INCINERATOR. ASPER SOLAS 74 I/II.
Construction/Loadline
Issued 31 August 2001
Resolved
CLEAN EXCESSIVE OIL FROM BILGES. AND RENEW PIPE LAGGING NEAR OIL TRANSFER PUMP. AS PER SOLAS 74 I/II.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.