MAURY USCG vessel records Sign in
← All vessels

HIFC II

HIFC II is a 1998 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 1998, most recently in August 2016, along with 14 deficiencies — 1 with no resolution recorded —.

Records from 1998 to 2016. Most recent: inspection, 8 August 2016.

Built
1998
Last inspected
8 August 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ9879
476854
Flag
UNITED STATES
—
Maury page id
psix-476854

Inspections, by type

Years with a record 13 calendar years (1998–2016)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it1 - Regulatory (Subpart C or D), Gross Ton
1 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

8 August 2016 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5965619
14 June 2012 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4341546
11 May 2009 Hull Examination · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3472084
4 June 2008 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3225251
3 May 2007 Annual Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2916862
27 April 2006 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2651839
16 March 2005 Hull Examination · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2312950
25 May 2004 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2077986
17 June 2003 Hull Examination · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1821343
19 July 2001 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1431075
27 July 2000 Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1429392
30 June 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1416923
1 July 1998 Initial Certification · Plan Review "T" Boat · Hull Examination · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 792919

Deficiency record · 14

Electrical › Electrical Distribution System (service) › Cable
Issued 3 May 2007 Resolved
Repair splice in wiring harness for radio under Console.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 8 June 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 May 2007 Resolved
Replace retro and line on life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 8 June 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 May 2007 Resolved
Replace life ring light line
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 8 June 2007
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 May 2007 Resolved
Replace retro on 8 Life jackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 8 June 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 April 2006 Resolved
Properly install lanyard that secures floating waterlight to ring life buoy IAW 46 CFR 180.70(d)(2).
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 3 May 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 April 2006 Resolved
Properly install corrosion-resistant clip to attach floating waterlight to the lanyard IAW 46 CFR 180.70(d)(3).
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 3 May 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 March 2005 Resolved
REPLACE TWO (2) ADULT TYPE I PFD'S.
Action required: 705 - Other - as specified
Resolved 16 March 2005
Resolution: REPLACE SAME WITH TWO NEW.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 16 March 2005 Resolved
PROVIDE COPY OF ANNUAL SERVICING.
Due 30 March 2005
Resolved 16 March 2005
Resolution: OWNER REMOVED FROM VSL AND PROVIDED SAME FOR SERVICE.
Documentation › Markings/Placards › Lifejacket Placard
Issued 16 March 2005 Resolved
PROVIDE LIFEJACKET DONNING PLACARD.
Action required: 705 - Other - as specified
Due 30 March 2005
Resolved 27 April 2006
Resolution: Lifejacket donning placard posted.
Lifesaving › Lifejacket/PFD (Type I)
Issued 25 May 2004 Resolved
REPLACE ONE (1) ADULT TYPE I PFD.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 May 2004
Resolution: REPLACED WITH NEW.
Engineering › Gasoline Engine (propulsion)
Issued 25 May 2004 No resolution recorded
ENGINE FAILED TO CRANK/START FOR UNDERWAY DRILLS.
Action required: 705 - Other - as specified
Resolution: REPLACED STARTING BATTERY.
Documentation
Issued 19 July 2001 Resolved
PROVIDE FCC ISSUED SAFETY RADIO CERTIFICATE. VESSEL LIMITED TO 1000 FT FROMSHORE UNTIL PROVIDED AS REQUIRED BY 47 CFR 80.901.
Condition: Unknown
Due 19 August 2001
Resolved 23 July 2001
Documentation
Issued 27 July 2000 Resolved
PROVIDE FCC ISSUED SHIP RADIO STATION LICIENCE.
Condition: Unknown
Due 1 August 2000
Resolved 28 July 2000
Navigation
Issued 1 July 1998 Resolved
MAKE REPAIRS TO NAV LIGHTS. VESSEL IS LIMITEDE TO DAYLIGHT OPERTION ONLY.
Condition: Unknown
Due 1 August 1998
Resolved 7 July 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.