18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 10 June 2026
Resolved
Drug and Alcohol Program (DAPI) – Provide up to date enrolment with all crewmembers including licensed mates. Current list has a licensed mate that has not completed their test. Provide prior to a trip requiring a licensed mate.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 10 June 2026
Resolved
Mates License – Provide a copy of the mate’s credential prior to a trip requiring the mate position.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 June 2026
Resolved
Sail Rigging Corrections – As marked on sail rigging survey
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 June 2026
Resolved
Emergency Exits need to be marked appropriately.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 June 2026
Resolved
Multiple Emergency Exits are lockable from inside.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 June 2026
Resolved
Provide Appropriate Up to Date Navigation Publications
a. Coast Pilot
b. Light List
c. Tide and Current Tables
d. Nav Rules
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 10 June 2026
Resolved
Loadline Certificate – Provide updated ABS cert.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2026
Resolved
Lifejacket Donning Placards – Permanently affix to area for passengers to see.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 June 2026
Resolved
Hatch covers are required to be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent losing the hatch. The forepeak hatch is not currently attached.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 June 2026
Resolved
Captain could not demonstrate operation of NAVTEX – Demonstrate proper operation of unit.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 June 2026
Resolved
The master should ensure that the EPIRB test is logged monthly. No records were produced during this inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 10 June 2026
Resolved
Certificated Liferaft Personnel – Provide training program in accordance with COI
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 June 2026
Resolved
The master is required to log the monthly testing of the rescue boat. No records were produced during the inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 10 June 2026
Resolved
The vessel is required to post a 1-800 number for their Employee Assistance Program in accordance with 46 CFR part 16. No number was posted during our inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2026
Resolved
The lifeline on the starboard side life ring was found frayed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 June 2026
Resolved
Smoke Detectors – All smoke detectors need to be interconnected before carrying overnight passengers.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 June 2026
Resolved
First Aid Kit – Inventory your kit and ensure all items are present in accordance with 46 CFR 160.041
Due 10 June 2026
Resolved 12 June 2026
Resolution: First Aid kit provided.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 June 2026
Resolved
The copy of the vessel's COD on board was expired. Provide updated copy.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2026
Resolved
Lifejacket and Immersion Suit Lights – Numerous lights failed testing.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 June 2026
Resolved
Engine Space – Prove proper operation of heat detector.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2026
Resolved
All draperies must be made of fire-retardant material. Provide proof of material or remove currently installed draperies.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 June 2026
Resolved
The green light in the engine room is not protected with a guard.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2026
Resolved
All trash cans on board need to be made of non-combustible materials. Found multiple plastic trash cans on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 12 June 2026
Resolution: Proper waste cans provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2026
Resolved
All work vests need to have the USCG 160.053 approval. The current work vests on board does not meet that standard.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2026
Resolved
Ensure the entrance to the CO2 cylinder space and the space being protected by the CO2 system has warning statements in accordance with 46 CFR 169.732
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2026
Resolved
The vessel is required two power driven bilge pumps connected to the manifold. Only one was available for testing.
Due 10 June 2026
Resolved 12 June 2026
Resolution: Jabsco pump and lister pump both tested.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2026
Resolved
Portable fire extinguisher 05 in the navigation suite was not tested this year. Provide proof of testing.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 10 June 2026
Resolved
Heavy Weather Harness needs to meet the Offshore Racing Council standards. Provide proof that it meets that standard. Going Aloft harnesses – provide proof that those harnesses are still within manufacturers’ timeline to be in good working order.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2026
Resolved
Generator Windings Need to be cleaned.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 June 2026
Resolved
Top of generator panel is currently secured with duct tape – repair and properly secure panel.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 June 2026
Resolved
Fuel manifold to genset line is leaking – replace with approved fuel hose and correct leak. Hose must meet standards in accordance with 46 CFR 182.720 (e)
Due 10 June 2026
Resolved 12 June 2026
Resolution: New hoses provided for whole fuel system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2026
Resolved
All raw water hose connections require double hose clamps where applicable.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 12 June 2026
Resolution: Attended vessel and verified that this item has been corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2026
Resolved
All Coast Guard-approved flexible fuel hose connections require double hose clamps where applicable.
Due 10 June 2026
Resolved 12 June 2026
Resolution: New hoses provided. Cable clamps not needed. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2025
Resolved
Vessel could not provide evidence of DAPI enrollment for full complement of crew. Vessel did have enough crew enrolled for day sails as a smsll passenger vessel. Prior to operating as a school ship or over 12 hours as a SPV, provide proof of enrollment for full vrew in a proper DAPI program.
Action required: 705 - Other - as specified
Due 2 July 2025
Resolved 3 July 2025
Resolution: Received Consortium paperwork.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 June 2023
Resolved
. Provide proof of testing of engine room heat detector. 46CFR169.311
Due 1 June 2023
Resolved 13 June 2023
Resolution: Testing completed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2023
Resolved
Trash cans must be a noncombustible material. Can on deck was rubber/plastic. 46CFR169.323(e)
Due 1 June 2023
Resolved 13 June 2023
Resolution: Can replaced with a metal can
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2023
Resolved
Provide label on interior of child life jacket boxes to eliminate confusion between adult and child life jackets. Min. 1” letters. 46CFR169.545
Due 1 June 2023
Resolved 13 June 2023
Resolution: Labels provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2023
Resolved
Repair/replace all nonworking lights on lifejackets and immersion suits as needed. 46CFR169.545
Due 1 June 2023
Resolved 13 June 2023
Resolution: Lights repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2023
Resolved
Repair/ replace both fire axes as needed. 46CFR169.569
Due 1 June 2023
Resolved 13 June 2023
Resolution: Axes replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 June 2023
Resolved
Repair/replace forepeak bilge alarm.
Due 1 June 2023
Resolved 13 June 2023
Resolution: Alarm repaired.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 June 2023
Resolved
Interconnected fire alarms not working properly. Repair/replace. Interim T boat IFR’s
Due 1 June 2023
Resolved 13 June 2023
Resolution: Alarms repaired and tested.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2023
Resolved
Remove dead end wires from engine room.
Due 1 June 2023
Resolved 13 June 2023
Resolution: Wires removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2023
Resolved
Fix leaks on fuel manifold and replace unauthorized fuel hose as needed.
Due 1 June 2023
Resolved 13 June 2023
Resolution: Leaks fixed and hose replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2023
Resolved
Fix fuel supply handle where it makes contact with fuel tank.
Due 1 June 2023
Resolved 13 June 2023
Resolution: Handle repaired and tested.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 June 2023
Resolved
Fix undersize shackles on sheet traveling block pad eyes.
Due 1 June 2023
Resolved 13 June 2023
Resolution: Shackles replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2023
Resolved
. All work vests must have approval code 160.053. Remove or replace unauthorized work vests. 46CFR169.556
Due 1 June 2023
Resolved 13 June 2023
Resolution: Unauthorized vests removed from vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 June 2023
Resolved
Foremast boom has rot on underside at mast end. Survey, repair as needed. Will be addressed at drydock.
Due 31 May 2024
Resolved 1 October 2023
Resolution: Boom repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2023
Resolved
Drapes in cabin had no labels. Provide proof of fire resistance or remove. 46CFR169.323
Due 1 June 2023
Resolved 13 June 2023
Resolution: Drapes removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 June 2023
Resolved
Engine room does not have emergency light as required. Provide E light for engine room. 46CFR169.711
Due 1 June 2023
Resolved 13 June 2023
Resolution: E-light installed in ER and tested.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 June 2023
Resolved
Label all emergency lights with an “E”. 46CFR169.738
Due 1 June 2023
Resolved 13 June 2023
Resolution: Labels provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 June 2023
Resolved
Provide “Sailing Directions” pub for Nav library.
Due 1 June 2023
Resolved 13 June 2023
Resolution: Pub provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2023
Resolved
Provide all CO2 system safety placards as required by 46CFR169.732
Due 1 June 2023
Resolved 13 June 2023
Resolution: Placards provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2023
Resolved
Ensure all fire extinguishers have numbers that match their corresponding stations. 46CFR169.737
Due 1 June 2023
Resolved 13 June 2023
Resolution: All extinguishers and stations labelled.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 June 2023
Resolved
Fire hose must be fitted with a combination nozzle approved under 46CFR162.067. Nozzles did not display this approval. Provide proof of approval or replace with proper nozzles.
Due 1 June 2023
Resolved 13 June 2023
Resolution: Pastic nozzle replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 June 2023
Resolved
Vessel could not provide proof of maintenance of sail rigging system. This requirement was corrected by sail rigging survey provided by Willy Leathers. All maintenance called out by survey must be completed to the satisfaction of the Coast Guard.
Due 1 June 2023
Resolved 18 June 2025
Resolution: Received sail rigging survey from third party.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 March 2023
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Two waterlights had expired or unapproved batteries. Vessel limited to daylight operations only.
Action required: 705 - Other - as specified
Due 24 March 2023
Resolved 20 March 2023
Resolution: Received pictures of replaced float lights.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 November 2022
Resolved
Vessel needs watchmen alarms IAW new interim regs. Vessel needs 24V system. Only 12V available. system on back order. Regs only apply as a T boat. Vessel may not operate as an overnight T boat until system is installed.
Due 15 November 2022
Resolved 18 June 2025
Resolution: Watch Alert system installed and tested.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 September 2022
Resolved
Call sign not posted on cabin top.
Due 15 September 2022
Resolved 14 September 2022
Resolution: Call sign painted on cabin top.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2022
Resolved
Excessive leak at shaf.t packing
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2022
Resolved 29 September 2022
Resolution: Shaft repacked. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2022
Resolved
Exhaust piping has wasted section that is leaking.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2022
Resolved 29 September 2022
Resolution: Leaking section of pipe replaced.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 September 2022
Resolved
EPIRB does not have current registration sticker.
Due 20 September 2022
Resolved 9 September 2022
Resolution: Sticker provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 September 2022
Resolved
Vessel does not have required hand operad fire pump.
Due 6 September 2022
Resolved 14 September 2022
Resolution: Pump provided and tested.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 September 2022
Resolved
Vessel does not have fire detection IAW new T boat IFR.
Due 6 September 2022
Resolved 14 September 2022
Resolution: Blue tooth smoke detectors installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 September 2022
Resolved
Vessel taking on a stream of water along keel below galley.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2022
Resolved 29 September 2022
Resolution: Tailshaft pipe replaced. Leaking stopped.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 September 2022
Resolved
Fuel filter on lister pump is plastic and does not meet regs.
Due 6 September 2022
Resolved 9 September 2022
Resolution: Filter replaced with metal filter.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 30 September 2021
Resolved
Vessels SSB DSC MF/HF radio did not pass FCC inspection. Vessel restricted to 20 miles from shore pending satisfaction of FCC requirements and issuance of required FCC documents.
Action required: 705 - Other - as specified
Due 1 October 2021
Resolved 6 October 2021
Resolution: Bridge-to-Bridge cert issued by FCC rep.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 July 2021
Resolved
Drug testing enrollment/negative pre-employment results must be provided for each individual acting in a safety sensitive position.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2021
Resolved 13 July 2021
Resolution: Received Roster.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 12 July 2021
Resolved
Crew could not demonstrate proper DSC functionality. Provide evidence of DSC functionality.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2021
Resolved 14 July 2021
Resolution: Attended VSL. Crew demonstrated DSC functionality.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 12 July 2021
Resolved
Provide a copy of oncoming mate’s license.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2021
Resolved 14 July 2021
Resolution: Mate provided license.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 July 2021
Resolved
Label engine room ventilation scoops.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2021
Resolved 14 July 2021
Resolution: Verified vents labeled.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2021
Resolved
Replace blade fuses from electrical system with an approved type. Per 46 CFR 183.380, fuses must be of the cartridge type only and be listed under UL.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2021
Resolved 14 July 2021
Resolution: Fuses replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2021
Resolved
Replace 20A fuse with 30A fuse on the SSB battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2021
Resolved 14 July 2021
Resolution: Fuse replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2021
Resolved
Anti-strain clamp needed on the MDE control panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2021
Resolved 14 July 2021
Resolution: Anti-Strain clamp installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 July 2021
Resolved
Affix electric bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2021
Resolved 14 July 2021
Resolution: Bilge pump affixed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2021
Resolved
Amend electrical plan to include engine room heat alarm and galley fan. By next credit DDX.
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 23 June 2022
Resolution: Drawings updated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2021
Resolved
Engine room junction box needs to be secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 14 July 2021
Resolution: Junction box mounted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2021
Resolved
Inverter switch needs to be secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 14 July 2021
Resolution: Inverter Secured.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 September 2020
Resolved
Vessel's stability letter does not appear be in compliance with CVC policy letter 11-03 regarding passenger weight change. An addendum was never issued indicating the number of persons permitted using updated AAWP. Coordinate with the Marine Safety Center to rectify the issue.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2020
Resolved 14 October 2020
Resolution: Stability letter addendum issued by MSC.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 9 September 2020
Resolved
MF Radio is inoperable. Vessel is limited to 20nm from shore pending repair/replacement.
Action required: 705 - Other - as specified
Due 30 September 2020
Resolved 30 October 2020
Resolution: MF/HF RADIO w/SSB installed and tested SAT. Vsl currently equipped to operate within 100NM from shore.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 9 September 2020
Resolved
Fire/bilge pump needs to be repaired/replaced/altered to produce 50gpm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2020
Resolved 30 September 2020
Resolution: Pump repaired and tested in the presence of MI.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 9 September 2020
Resolved
Provide dedicated alarm for the Heat detector in the engine room. Currently the heat detector alarms on the bilge alarm panel.
Action required: 705 - Other - as specified
Due 30 September 2020
Resolved 30 September 2020
Resolution: Dedicated alarm installed and tested in the presence of MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 September 2020
Resolved
Drapes in berthing areas not fire retardant.
Action required: 705 - Other - as specified
Due 30 September 2020
Resolved 28 September 2020
Resolution: All bunk & cabin curtains have been treated with fire retardent according to the manufacturer's directions.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2020
Resolved
Make all holes in subdivision bulkheads watertight.
Action required: 705 - Other - as specified
Due 30 September 2020
Resolved 30 September 2020
Resolution: Holes in subdivision bulkheads made watertight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 September 2020
Resolved
Junction box in focsle needs cover secured.
Action required: 705 - Other - as specified
Due 30 September 2020
Resolved 30 September 2020
Resolution: Junction box cover replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 September 2020
Resolved
Fan in galley needs junction box for wire splice.
Action required: 705 - Other - as specified
Due 30 September 2020
Resolved 30 September 2020
Resolution: Junction box installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 September 2020
Resolved
Bilge Alarm for FWD compartment inoperable. Repair/replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2020
Resolved 30 October 2020
Resolution: Bilge alarm installed and tested in the presence of MI.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018
Resolved
The vessel is currently broadcasting (1) Improper Length.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2018
Resolved 29 September 2022
Resolution: AIS corrected
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 February 2018
Resolved
Provide proof of credit Dry dock. Prior to carrying passengers or departure from port.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2018
Resolved 2 March 2018
Resolution: Confirmed Annual inspection and Dry Dock credit was given