← All vessels
BEIJING VICTORY
BEIJING VICTORY is a 1979 freight ship. The Coast Guard has recorded 33 inspections since 1998, most recently in February 2009, along with 41 deficiencies and 12 operational controls.
Records from 1998 to 2009. Most recent: inspection, 18 February 2009.
- Built
- 1979
- Last inspected
- 18 February 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 41 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7610725 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EKD3
476925
Flag
PANAMA
—
Maury page id
psix-476925
Inspections, by type
…with no type recorded12
Years with a record
8 calendar years (1998–2009)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it32371 - Convention (Subpart B), Gross Ton
19249 - Convention (Subpart B), Net Ton
54600 - Dead Weight, Ton
66978 - Displacement, Ton
19249 - Convention (Subpart B), Net Ton
54600 - Dead Weight, Ton
66978 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
18 February 2009
Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3417779
30 January 2009
ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3400163
15 January 2009
Deficiency Check · MARPOL Annex I Examination · ISPS III Exam · PI Safety Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3394503
29 December 2008
MARPOL Annex V Examination · Ballast Water Examination · PI Safety Exam · Deficiency Check · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3384518
6 December 2008
ISPS III Exam · PI Safety Exam · Deficiency Check · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3375127
16 November 2008
ISPS III Exam · MARPOL Annex I Examination · PI Safety Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3363941
3 November 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3356731
30 October 2008
Ballast Water Examination · MARPOL Annex I Examination · PI Safety Exam · ISPS III Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3350624
28 October 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3352637
10 October 2008
PI Safety Exam · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3342369
29 September 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3334699
17 September 2008
PI Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS III Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3324648
22 August 2008
ISPS III Exam · Ballast Water Examination · PI Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3300138
29 July 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3283553
14 July 2008
ISPS III Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3264325
14 July 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3267325
14 July 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3267539
9 June 2008
Ballast Water Examination · PI Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3227373
21 May 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3212176
7 April 2008
PII Safety Exam · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3177671
20 March 2008
ISPS III Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3164003
5 March 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3158497
5 March 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3158819
4 February 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3141464
6 October 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3074196
23 January 2002
Certificate of Compliance · Tank Vessel Examination · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1481026
15 February 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 287039
5 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 281970
2 March 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 275292
7 August 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 431435
7 August 1999
Tank Vessel Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 778407
15 July 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 418225
15 July 1998
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1130582
Deficiency record · 41
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 30 January 2009
Resolved
The voyage data recorder on the bridge is displaying an error code and is not operational.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 30 January 2009
Resolved
The diesel oil service tank remote emergency safety shut off valve for the auxillary engines was found wired open with a welding rod. This effectively bypassed the ability to remotely shut off the tank in the event of a fire. The No.1 and No.2 auxillary engines were both online at the time.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 29 December 2008
Resolved
Emergency fire pump could not provide adequate water pressure, further more an exhaust leak was discovered requiring the pump to be secured and space evacuated.
Pollution Prevention/Response › Response Equipment › Containers
Issued 6 December 2008
Resolved
Provide plan on how the vessel will monitor, clean up, contain and dispose of hydraulic leaks from cargo system.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 6 December 2008
Resolved
Air bottles are empty.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 6 December 2008
Resolved
Provide proof water spray system is operational
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 6 December 2008
Resolved
SEC does not state that the lifeboats are totally enclosed, self-contained or have a water spray system.
Fire Fighting › Emergency Fire Pumps › Capacity
Issued 16 November 2008
Resolved
Emergency Fire Pump found inoperable. Class report states that the pump is to be operable by 16 November, 2008.
Engineering › Lubricating Oil Service System › Purifier
Issued 16 November 2008
Resolved
Diesel oil purifier pump missing. Replace pump to the satisfaction of Class. Class report states pump is on order and vessel has till the 17th of January 2009 to repair. See AN 3363941 narrative for details.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 November 2008
Resolved
The electrical box has unapproved electrical modifications to the Oil Content Meter.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 16 November 2008
Resolved
5 Halon bottles (1,2,5,7 and 19) found to be hydrostatically 10/89. Vessel crew could not provide proof of any later hydrostatic test. Class or Flag to provide clarification of hydro dates. System tested and found satisfactory however no hydrostatic dates have been provided. See AN 3363941 narrative for details
Fire Fighting › Fire Main › Condition
Issued 16 November 2008
Resolved
The fire main found 2 leaks. The dresser coupling over the port side hatch into the accomodation sprayed water during the fire drill. A second leak was found under the hatch to the bosun store on the starboard side of the forecastle.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 30 October 2008
Resolved
Emergency fire pump found inoperable at time of inspection. Flag allowed vessel to sail from Jamaica to New Orleans to affect repairs. Fire Pump and Ship Service pump tested and found to produce satisfactory fire pressure. Emergency fire pump to be sent ashore in NOLA for repairs.
03NOV08 RCVD class rpt extending repair date until 30NOV08. Temp diesel pump installed and tested satisfactory.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 30 October 2008
Resolved
The mechanical seal on fire pump #1 leaks during operation and when secured. There is satisfactory pressure in the fire main when tested. Fire pump #2 and the general service pump tested and found satisfactory.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 30 October 2008
Resolved
The #2 Ship Service Diesel Generator is leaking fuel oil from the top seal of fuel pumps #4 and #6.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 30 October 2008
Resolved
The #1 ship service diesel generator is leaking fuel oil from the top seal on the #5 fuel pump.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 30 October 2008
Resolved
Emergency Generator leaking fuel oil from the top of fuel pump at hose fitting to fuel rail.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 30 October 2008
Resolved
Both port and starboard bridge wing gyro compass repeaters were found to be 90 degrees off gyro compass heading. Repeaters corrected during inspection by vessels 3rd officer. Vessel must provide service technician report attesting to the proper operation of both repeaters.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 30 October 2008
Resolved
Garbage log missing entry when garbage was transferred ashore in Jamaica on 22OCT08. Receipt found in log book; however, the transfer was not recorded. Log corrected during inspection.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 30 October 2008
Resolved
The Emergency Escape Breathing Device in ladder way between the 2nd and 3rd deck was found to be depleted. The unit in question was replaced during inspection, with a spare.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 30 October 2008
Resolved
Muster list in the Fire Plan had not been updated since 11OCT08 to reflect the two new crew members that reported aboard. Muster list was updated during inspection.
Construction/Loadline › Markings › Load Line Mark
Issued 30 October 2008
Resolved
Loadlines were not in contrasting color to the hull of the vessel during the inspection. Loadlines repainted during the inspection.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 17 September 2008
Resolved
The Captain and [name withheld] could not produce the Garbage Management Plan to the [name withheld], the Garbage Record Book does not accurately reflect the actual discharge of garbage to shore. Garbage discharge to shore was incorrectly logged as discharge to sea 2 times. The PSCO also found 1 garbage discharge to shore that was not recorded in the Garbage Log Book.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 17 September 2008
Resolved
The Echo Depth Sounding Recorder is inoperable. Provide report from the attending classification society attesting to the proper operation of the Echo Depth Sounding Recorder.
Construction/Loadline › Penetrations › Pipe Flange
Issued 22 August 2008
Resolved
The hydraulic line for the port cargo hold No. 3 has a temporary patch. In addition, the hydraulic line between cargo hold No.5-6 is leaking.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 22 August 2008
Resolved
The bunkering lines was last hydrostatically tested on 13Aug2007. The lines need to be retested before conducting bunkering operation in the U.S. waters.
Engineering › Lubricating Oil Service System › Pump
Issued 14 July 2008
Resolved
A temporary arrangement of an oil pump from the on the main engine has been assembled without classification society approval. Classification society must prove proper operation or removal of temp arrangement. Vessel must provide attestation prior to movement.
Engineering › Sea-water System (primary cooling) › Pump
Issued 14 July 2008
Resolved
A significant water leak from the #1 salt water cooling pump for the main engine intercooler is leaking approximately 1 gallon/minute and is draining into the bilges. The bilges have filled to a level that have caused a constant high level alarm from the bilges from which the crew has not taken any action to rectify the situation.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 July 2008
Resolved
After numerous attempts, the crew was unable to demonstrate proper operation of the oily water separator. During the exam, PSCO noticed the broken pipe.
Lifesaving › Launching Appliances › Davit
Issued 14 July 2008
Resolved
During testing of lifeboat launching arrangements, both sides were found to not freely lower to the water.
Engineering › Lubricating Oil Service System › Purifier
Issued 14 July 2008
Resolved
A valve leading from the purifier steam line to the heating coil was wasted and leaking.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 14 July 2008
Resolved
A soft patch was found on the line from the fresh water cooling line to the ship’s service generator.
Engineering › Compressed Air System (control) › Compressor
Issued 14 July 2008
Resolved
During inbound transit in Mississippi River, vessel experienced a power irregularity.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 20 March 2008
Resolved
The vessel does not have two of the required Emergency escape breathing devices as noted on the vessels Fire Control Plan.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 20 March 2008
Resolved
It was found that the emergency remotely operated shut off valves for both the main engine and auxiliary engines were hard wired opened. This effectively bypassed the ability to remotely shut off those tanks in the event of an emergency. The vessel is to repair valves and prove proper operation to class prior to departure from port.
Navigation › Piloting/Steering › Gyro Compass
Issued 5 March 2008
Resolved
While operating in the Sector New Orleans COTP zone, it was discovered that the vessel's gyrocompass was not operational.
Pollution Prevention/Response › Prevention Equipment
Issued 24 January 2002
Resolved
Item to be replaced whilst dockside prior to departure from port. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Deck/Cargo
Issued 5 September 2000
Resolved
PERMANANTLY REPAIR TEMPORARY PATCH ON HYD. RETURN LINE BEHIND STBD MANIFOLD
Engineering
Issued 5 September 2000
Resolved
REPAIR OIL LEAK AND PROVIDE CLASS REPORT FOR MAIN ENGINE CYLINDER #2 EXHAUST VALVE OIL LINE.
Lifesaving
Issued 5 September 2000
Resolved
LIMIT SWITICH ON STBD LIFEBOAT DAVITS NOT OPERATIONAL. PROVIDE CLASS REPORTATTESTING TO PROPER OPERATION.
Deck/Cargo
Issued 5 September 2000
Resolved
PROVIDE CLASS REPORT ADDRESSING WATER BUILD UP IN IGS DECK LINE. PRIOR TO CARGO OPERATIONS IN US WATERS
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.