← All vessels
RELIABLE
RELIABLE is a 1973 towing vessel. The Coast Guard has recorded 52 inspections since 1981, most recently in January 2013, along with 78 deficiencies and 2 casualty investigations between 2001 and 2010.
Records from 1981 to 2013. Most recent: inspection, 7 January 2013.
- Built
- 1973
- Last inspected
- 7 January 2013
- Documentation
- No Operation - PM · documentation file of 10 September 2026
- Deficiencies
- 78 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2001–2010
Identity
552294
WDC7610
47703
Flag
UNITED STATES
367074020, 367619670 (licence lapsed)
Maury page id
psix-47703
Inspections, by type
…with no type recorded21
Years with a record
26 calendar years (1981–2013)
The 52 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 13 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)94.0 ft × 25.0 ft × 2.8 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIVERSAL IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELFORD, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDH4628MMSI 367619670 · expired · compulsorily equipped · granted 8 May 2014, cancelled 13 July 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDC7610MMSI 367074020 · expired · compulsorily equipped · granted 28 October 2005, cancelled 2 January 2016
WCD6365MMSI not assigned · expired · compulsorily equipped · granted 2 March 1999, cancelled 4 April 2009
WCY8851MMSI not assigned · expired · voluntarily equipped · granted 16 February 1999, cancelled 18 April 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 52
7 January 2013
Ballast Water Examination · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4511700
13 February 2012
Annual Inspection · Internal Structural Exam · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4223609
6 December 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3905346
6 December 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3905480
29 November 2010
Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 3900756
29 November 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3901053
29 November 2010
Annual Inspection · Damage Survey · DAPI Audit · Administrative Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3902221
11 January 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3660938
21 January 2009
Re-Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3393882
10 January 2008
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3127917
28 March 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2896651
21 March 2007
Examination of Repairs · In-Service Inspection · Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2896619
15 November 2006
Deficiency Check · Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2820649
31 May 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2666426
31 May 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2666467
5 May 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2641578
5 May 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2641624
31 March 2006
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2613507
19 April 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2337129
16 December 2003
Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1964970
30 January 2003
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1737562
8 July 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1642723
27 June 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1642699
31 October 2001
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1456029
15 September 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 173026
11 January 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471036
30 November 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455793
29 November 1999
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 1510144
27 January 1999
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360733
3 December 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418272
7 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1121982
3 July 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461812
6 December 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356018
8 December 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443639
19 December 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355041
3 January 1994
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389745
3 June 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 683606
8 March 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425298
11 July 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 102375
9 March 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 676474
3 February 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953014
20 December 1990
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243362
13 July 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335748
16 January 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319141
17 January 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291004
17 January 1986
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333533
7 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984267
18 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282818
15 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279875
10 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271426
22 January 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965038
29 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273441
Deficiency record · 78
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 January 2013
Resolved
Remote E/R blower control wire was installed through the fiddley deck without a stuffing tube or device to make it watertight.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 7 January 2013
Resolved
2 F/O vent screens were worn.
Electrical › Electric Generation Source (service) › Generator
Issued 7 January 2013
Resolved
Both generator windings were dirty.
Construction/Loadline › Hull › Stiffener
Issued 7 January 2013
Resolved
Wasted angle on the port side access gate was wasted. Area was also used as a support for the rescue platform. Angle to be renewed.
Electrical › Electric Supply System (service) › Cable
Issued 13 February 2012
Resolved
Provide/replace extension cord wiring in cabinet under operating station with approved boat electrical wire.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 February 2012
Resolved
Repair electrical wiring on freezer. Cord is spliced apart aand held together with electrical tape.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 13 February 2012
Resolved
Repair electrical wiring for overhead light fixture in crew lounge (light near TV). Unapproved electrical cord is plugged in to bulkhead outlet and then spliced into bulkhead wall switch.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 13 February 2012
Resolved
Provide proper battery cable attachments for batteries under operating station. Alligator and spring clips are presently being used.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 January 2012
Resolved
Condition - Wasted
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 29 November 2010
Resolved
Vsl operator could not provide required records for chemical testing program IAW 46 CFR 16.260
Stability › Watertight Integrity › General
Issued 29 November 2010
Resolved
Gaskets on both Watertight Hatches to Steering compartment are deteriorating. Replace with proper material to provide watertight seal, IAW 46 CFR 171.124 (a).
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 29 November 2010
Resolved
Vsl Shaft packing on Port & STBD main shafts, seals are leaking and need adjusted/renewed, IAW 46 CFR 176.25-10(a)(1).
Engineering › Steering Gear System › Hydraulic Hose
Issued 29 November 2010
Resolved
Prove proper operation of Steering System, due to failed Hydraulic hose. IAW 46 CFR 176.800.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 29 November 2010
Resolved
Pump Diesel Fuel & Oily mixture from Steering compartment Bilge, prior to operating Steering Gear. Pump out IAW State, Local laws and 46 CFR 176.830(b).
Navigation › Piloting/Steering › Marine Charts
Issued 29 November 2010
Resolved
Provide current and corrected Navigation Charts for the local Tampa Bay navigational area. IAW 46 CFR 184.420.
Personnel › Certificates/Documents/Licenses › License, Pilot
Issued 29 November 2010
Resolved
Vsl does not have a license mariner onboard that is familiar with Tampa Bay. Vsl must have licensed mariner or Pilot in control of the vsl while transiting Tampa Bay, IAW 46 CFR15.812(b)(2)(iii).
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 11 January 2010
Resolved
Provide up to date Coast Pilot [name withheld], and Current Tables.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 11 January 2010
Resolved
Repair lagging on port MDE.
Construction/Loadline › Hull › Bottom Plating
Issued 11 January 2010
Resolved
Attach double nut to port shaft log.
Communications › Radio Communications › Emergency Source of Power
Issued 21 January 2009
Resolved
SSB had no e-power.
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 January 2009
Resolved
Remote fuel transfer pump shut off not working properly.
Communications › Alarms/Indicators › Fire Alarm
Issued 21 January 2009
Resolved
smoke alarms not working properly
Navigation › Piloting/Steering › Marine Charts
Issued 10 January 2008
Resolved
Provide updated charts for approaches to ports/areas transitted.
Engineering › Freshwater System (cylinder head cooling) › Sensor
Issued 10 January 2008
Resolved
Renew temp sensor for stbd MDE temp gauge and prove proper operation.
Engineering › Lubricating Oil Storage/Transfer System › Vent Pipe
Issued 10 January 2008
Resolved
Provide a means of immediate closure for lube oil vent on deck.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 January 2008
Resolved
Remove excess standing fuel/oil from machinery bilges.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 21 March 2007
Resolved
MSD overboard sewage discharge was not closed and locked while vessel was navigating within 3 nautical miles of shore in US waters and state waters of Louisiana.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 21 March 2007
Resolved
Vessel exceeded 12 hours within 24 without a second master on board as required by the COI
Electrical › Electrical Distribution System (service) › Switchboard
Issued 21 March 2007
Resolved
Blank off open circuits in E/R switchboard
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 21 March 2007
Resolved
Clear gear out of emergency exit and mark emergency exit
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 21 March 2007
Resolved
Clean both generator armatures
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 21 March 2007
Resolved
Tighten both shaft packings.
Engineering › Fuel Oil Service System › Piping
Issued 21 March 2007
Resolved
Repair numerous fuel system piping leaks.
Engineering › Fuel Oil Service System › Piping
Issued 21 March 2007
Resolved
Repair stbd MDE transmission oil line leak
Fire Fighting › Nozzles › Approval
Issued 21 March 2007
Resolved
Remove plastic fire nozzles from vsl and replace with approved nozzles. Demonstrate proper use for marine inspector.
Lifesaving › Lifefloat › Serviceable
Issued 21 March 2007
Resolved
Reservice both lifefloats
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 March 2007
Resolved
Replace nav lights with proper bulbs for proper visibility.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 March 2007
Resolved
Install guard around port side stack pipe next to ladder.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 March 2007
Resolved
Remount aft deck ladder stairs on main deck
Lifesaving › Buoyant Apparatus › Lifeline
Issued 21 March 2007
Resolved
Provide adequate lanyard for rescue platform harness.
Construction/Loadline › Hull › Bottom Plating
Issued 21 March 2007
Resolved
Submit vsl for dry-dock exam and remove doubler plate from rudder room. Properly insert hull plate, swach bulkhead & structural members as directed by CG marine inspectors.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 21 March 2007
Resolved
Submit chemical consortia list for employees to marine inspector
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 28 November 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 28 November 2006
Resolved
UPDATED EMERGENCY BROADCAT PLACARD WITH CORRECT CALL SIGN.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 28 November 2006
Resolved
UPDATED CERTIFICATE WITH CORRECT CALL SIGN.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 November 2006
Resolved
DEMONSTRATE PROPER OPERATION OF ALL BILGE ALARMS.
Electrical › Electrical Distribution System (emergency) › Switch
Issued 28 November 2006
Resolved
DEMONSTRATE PROPER OPERATION OF STOVE QUICK DISCONNECT.
Engineering › Fuel Oil Service System › Piping
Issued 28 November 2006
Resolved
PROVIDE PLUGS ON ALL TANKS AS DISCUSSED
Navigation › Piloting/Steering › Marine Charts
Issued 28 November 2006
Resolved
PROVIDE UPDATED NAV CHARTS.
Engineering › Fuel Oil Service System › Hose
Issued 28 November 2006
Resolved
INSTALL CHAFFING GEAR ON ALL HOSES AS MARKED.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 31 May 2006
Resolved
Failure to submit sailing short list as required.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 31 May 2006
Resolved
Failure to have a licensed mate on self propelled inspected vessel.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 31 May 2006
Resolved
Vessel operated without full compliment as required by COI.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 5 May 2006
Resolved
Failure to provide licensed mate as required by vessel's COI.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 5 May 2006
Resolved
Failure to submit sailing short report as required.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 5 May 2006
Resolved
Vessel operated without full compliment required by vessel's certificate of inspection.
Fire Fighting › Fire Main › Pressure
Issued 31 March 2006
Resolved
Demonstrate proper operation of the fire pump 60 psi prior to sailing.
Lifesaving › Buoyant Apparatus › Quantity
Issued 31 March 2006
Resolved
Renew life float paddles prior to sailing
Documentation › Logs/Records › Logbook (official)
Issued 31 March 2006
Resolved
Log pre arrival and departure checks in ship log as per 46CFR 97.35-5.
Documentation › Logs/Records › Logbook (official)
Issued 31 March 2006
Resolved
Log monthly EPIRB checks.
Personnel › Training › Ship's Business
Issued 31 March 2006
Resolved
Demonstrate crew proficiency in fire, abandon ship and man overboard drills to the satisfaction of an attending CG Marine inspector prior r to 30Apr2006.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 31 March 2006
Resolved
Hydro both engine room air receivers and provide test results if air receiver passes.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 31 March 2006
Resolved
Renew both air receivers at next dry-dock to the satisfaction of an attending CG Marine Inspector.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 30 December 2003
Resolved
Provide Notice to Mariners.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 30 December 2003
Resolved
Provide compass deviation card.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 December 2003
Resolved
Restock first aid kits throughout vessel.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 December 2003
Resolved
Repair rudder room bilge alarm.
Stability › Watertight Integrity
Issued 30 December 2003
Resolved
Renew gaskets on aft mess deck and engine room watertight doors. LEGACY COMPONENT DESC: Watertight doors
Engineering › Fuel Oil Service System › Hose
Issued 30 December 2003
Resolved
Provide proper approved fuel hose on all fuel systems.
Electrical › Electrical Distribution System (service)
Issued 30 December 2003
Resolved
Provide blanks for engine room power panel. LEGACY COMPONENT DESC: Distribution Panel Bus
Fire Fighting › Remote Fuel Shutoff
Issued 30 December 2003
Resolved
Repair starboard fuel oil reach rod shutoff. LEGACY COMPONENT DESC: Fuel shut off
Electrical › Lighting (emergency)
Issued 30 December 2003
Resolved
Provide emergency light for engine room emergency escape. LEGACY COMPONENT DESC: Battery Operated Lantern
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 January 2003
Resolved
REPAIR BILGE ALARMS FOR RUDDER ROOM.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 30 January 2003
Resolved
PROVIDE CURRENT LIGHT LIST AND TIDAL CURRENT TABLES.
Lifesaving › Lifebuoys
Issued 30 January 2003
Resolved
RENEW RETRO-REFLECTIVE TAPE ON ALL LIFE RINGS. LEGACY COMPONENT DESC: RETRO-REFLECTIVE TAPE
Communications › Radio Communications › EPIRB
Issued 30 January 2003
Resolved
REPAIR OR RENEW EPIRB.
Construction/Loadline
Issued 11 January 2001
Resolved
Install a bilge alarm in rudder room with audible and visual indicator at the operating station to the satisfaction of the attending marine inspector.
Construction/Loadline
Issued 30 November 1999
Resolved
PRIOR TO SAILING, INSTALL AND ENSURE PROPER OPERATION OF BOTH ENGINE ROOM WATERTIGHT DOORS TO THAT SATISFACTION OF ATTENDING MARINE INSPECTOR.
Casualty record · 2
15 September 2001Routine · role: Involved in a Marine Casualty · activity 173026
29 November 2010Routine · role: Involved in a Marine Casualty · activity 3901053
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
DAVID ADAMS (2001–2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.