Documentation record
Registered dimensions (L × B × D)42.0 ft × 15.0 ft × 5.0 ft
Registered tonnagegross 21 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMIDSHIP MARINE INC · HARVEY, LA, UNITED STATES · built 1998
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHAUVIN, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 9 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 12 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 12
10 October 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8247274
29 August 2024
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7991542
5 December 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7831801
30 August 2022
COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7531772
20 April 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6941288
1 May 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6669710
12 July 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6476386
18 August 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6437207
4 August 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6226135
24 July 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6219141
5 May 2016
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5869502
3 May 2016
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5868075
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 December 2023
Resolved
When the exhaust cooling water system is separate from the engine cooling water system, a suitable warning device, visual or audible, must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system. MI observed independent exhaust cooling system did not have a suitable warning device. Provide warning device to the satisfaction of the MI.
46 CFR 182.425(b)(5)
60 c
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 5 December 2023
Resolved 21 December 2023
Resolution: Clogged hoses to pressure guages on console were replaced to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 December 2023
Resolved
The piping must be properly supported by noncombustible hangers or blocks. Exhaust piping brackets were broken. Repair piping supports to the satisfaction of the attending MI.
46 CFR 182.430(b)
16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2023
Resolved 21 December 2023
Resolution: Exhaust mounting bracket was welded and pictures provided to the satisfaction of the MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 December 2023
Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. MI noted the aft door weathertight gasket is wasted and has missing portions. Replace gasket to the satisfaction of the MI.
46 CFR 179.360(d)
16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2023
Resolved 21 December 2023
Resolution: Aft door gasket replaced and pictures provided to the satisfaction of the MI.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 December 2023
Resolved
Vessels subject to part III of title III of the Communications Act that operate in the waters described in 47 CFR 80.901 must, at a minimum, be equipped as follows:(1) Vessels operated solely within 20 nautical miles of land must be equipped with a VHF–DSC radiotelephone installation meeting the requirements of 47 CFR 80.1101(c)(2). Marine inspector identified the MMSI was not programmed into the VHF-DSC radio installation. Program radio to the satisfaction of the MI.
47 CFR 80.905(a)(1)
16 C
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2023
Resolved 21 December 2023
Resolution: VHF radio was replaced and programmed to the satisfaction of the MI.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 December 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rule. Marine inspector found the stern light extinguished. Repair stern light to the satisfaction of the MI.
46 CFR 183.420
705 c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2023
Resolved 21 December 2023
Resolution: Navigation light bulbs replaced and pictures provided to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 October 2022
Resolved
A PRE-ENGINEERED FIXED GAS FIRE EXTINGUISHING SYSTEM MUST AUTOMATICALLY SHUT DOWN ALL POWER VENTILATION SYSTEMS AND ALL ENGINES THAT DRAW INTAKE AIR WITHIN THE PROTECTED SPACE. DURING THE MANUAL ACTUATION OF THE PRE-ENGINEERED FIX GAS FIRE EXTINGUISHING SYSTEM, THE SYSTEM WAS UNABLE TO SECURE THE ENGINES.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 11 October 2022
Resolved 29 December 2022
Resolution: Conducted sat test of pre-engineered system by ensuring the system was able to secure engines and that the engines were able to restart after resetting system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 October 2022
Resolved
A VESSEL MUST BE PROVIDED WITH A SATISFACTORY ARRANGEMENT FOR DRAINING ANY WATERTIGHT COMPARTMENT. THE VESSEL'S BILGE PUMP WAS INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2022
Resolved 29 December 2022
Resolution: Conducted sat test of bilge pump by testing at the sea chest and in the lazarette.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 October 2022
Resolved
PROVISION MUST BE MADE FOR CLOSING ALL SUPPLY DUCT COWLS OR SCOOPS AND EXHAUST DUCT DISCHARGE OPENINGS FOR A SPACE PROTECTED BY A FIXED GAS EXTINGUISHING SYSTEM. MARINE INPSECTOR IDENTIFIED THE SEALS FOR THE ENGINE ROOM ACCESS HATCHES WERE WORN PREVENTING THE SYSTEM FROM
WORKING AS INTENDED.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2022
Resolved 29 December 2022
Resolution: Checked the hatches and gaskets for the engine room access. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 October 2022
Resolved
EACH RING LIFE BUOY ON A VESSEL MUST BE APPROVED IN ACCORDANCE WITH 160.050 IN SUBCHAPTER Q OF THIS CHAPTER. THE BUNG HOLE ON THE RING BUOY WAS WASTED PREVENTING THE BUOY FROM BEING BUOYANT.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2022
Resolved 1 December 2022
Resolution: Vessel rep replaced buoy onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 11 October 2022
Resolved
THE LIGHT FOR THE LIFE FLOAT MUST BE A FLOATING WATERLIGHT APPROVED UNDER APPROVAL 161.010 OR OTHER STANDARD APPROVED BY THE COMMANDANT. THE BATTERY INSTALLED IN THE LIGHT FOR THE LIFE FLOAT WAS INCORRECT PREVENTING THE LIGHT FROM FLOATING.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2022
Resolved 1 December 2022
Resolution: Vessel replaced battery for life float with approved type.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2022
Resolved
THE GENERAL CONSTRUCTION OF THE VESSEL MUST BE SUCH AS TO MINIMIZE FIRE HAZARDS INSOFAR AS IT IS REASONABLE AND PRACTICABLE. MARINE INSPECTOR IDENTIFIED A HYDRAULIC OIL LEAK ON THE HYDRAULIC HAND IN THE FOWARD COMPARTMENT.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2022
Resolved 29 December 2022
Resolution: The fittings for the hydraulic hand in the forward compartment were replaced and are in working order.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 October 2022
Resolved
A FIRE HOSE WITH A NOZZEL MUST BE ATTACHED TO EACH FIRE HYDRANT AT ALL TIMES. ON THE MAIN DECK THE VESSEL DIDN'T HAVE A GARDEN TYPE HOSE OR VALVE INSTALLED.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 1 December 2022
Resolution: Vessel had 3 2.5 gallon fire buckets onboard meeting the requirement of the regulation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 October 2022
Resolved
ELECTRICAL EQUIPMENT ON A VESSEL MUST BE INSTALLED AND MAINTAINED TO PROTECT PASSENGERS, CREW, OTHER PERSONS, AND THE VESSEL FROM ELECTRICAL HAZARDS. MARINE INSPECTOR IDENTIFIED THE LIGHT IN THE ENGINE ROOM WAS EXTINGUISHED AND HAD EXPOSED WIRES.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 29 December 2022
Resolution: The housing and wiring for the engine room light were replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 October 2022
Resolved
THE CONSTRUCTION AND ARRANGEMENT OF A VESSEL MUST ALLOW THE SAFE OPERATION OF THE VESSEL IN ACCORDANCE WITH THE TERMS OF ITS CERTIFICATE OF INSPECTION GIVING CONSIDERATION TO THE PROVISIONS FOR A SEAWORTHY HULL, PRTECTION AGAINST FIRE, MEANS OF ESCAPE IN CASE OF A SUDDEN UNEXPECTED CASUALTY, GUARDS AND RAILS IN HAZARDOUS SPACES, VENTILATION OF ENCLOSED SPACES, AND NECESSARY FACILITIES FOR PASSENGERS AND CREW. MARINE INSPECTOR IDENTIFIED A CRACKED WELD USED TO SUPPORT THE VESSEL'S BILGE/ FIRE PUMP.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 1 December 2022
Resolution: Verified repair of the cracked weld.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 October 2022
Resolved
A VESSEL MUST COMPLY WITH THE APPLICABLE REQUIREMENT FOR ANY RADIO AND ELECTRONIC POSITION INDICATING RADIO BEACON (EPIRB) INSTALLATIONS, INCLUDING THE REQUIREMENTS FOR A STATION LICENSE AND INSTALLATION CERTIFICATES TO BE ISSUED BY THE FEDERAL COMMUNICATIONS COMMISSION. THE VHF RADIOS INSTALLED ON THE VESSEL WERE INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 October 2022
Resolved 1 December 2022
Resolution: Conducted satisfactory test of the vhf radio onboard the vessel.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 August 2022
Resolved
ON A VESSEL OF AT LEAST 26 FEET IN LENGTH, A VISUAL AND AUDIBLE ALARM MUST BE PROVIDED AT THE OPERATING STATION TO INDICATE A HIGH WATER LEVEL. DURING THE TESTING OF BILGE ALARMS, THE ALARM FOR THE ACCOMODATION SPACE WAS INOPERABLE.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2022
Resolved 1 December 2022
Resolution: Conducted satisfactory test of the bilge alarm in the accomodation space.