Records from 1985 to 1989. Most recent: inspection, 10 April 1989.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
10 April 1989
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1347124
12 September 1988
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1044228
16 June 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 894554
11 May 1988
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1349507
9 October 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1320204
16 July 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1020072
19 June 1987
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1011816
23 July 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 993199
26 June 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 996156
6 June 1986
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 988946
6 June 1986
Credit Drydock
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1297901
15 July 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 978847
Construction/Loadline
Issued 12 September 1988
Resolved
DRY DOCK VESSEL FOR EXAMINATION OF HULL DUE TO DAMAGE NOTED DURING INSPECTION.
Condition: Unknown
Due 12 September 1988
Resolved 12 September 1988
Electrical
Issued 11 May 1988
Resolved
REPLACE COVERS ON ALL ELECTRICAL JUCTION BOXES.
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Lifesaving
Issued 11 May 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Lifesaving
Issued 11 May 1988
Resolved
PROVIDE THREE (3) ADULT PFD'S.
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Electrical
Issued 11 May 1988
Resolved
REPAIR WATER PUMP FOR MAIN GENERATOR.
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Electrical
Issued 19 June 1987
Resolved
PROVIDE AND INSTALL VOLTMETER, AMMETER AND FREQUENCY METER FOR THE 220 VAC GENERATOR.
Condition: Unknown
Due 19 June 1987
Resolved 19 June 1987
Electrical
Issued 19 June 1987
Resolved
PROVIDE LABELS FOR ALL SWITCHES ON BRIDGE.
Condition: Unknown
Due 19 June 1987
Resolved 19 June 1987
Fire Fighting
Issued 19 June 1987
Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS SERVICED.
Condition: Unknown
Due 19 June 1987
Resolved 19 June 1987
Documentation
Issued 19 June 1987
Resolved
PROVIDE EVIDENCE OF DOCUMENTATION.
Condition: Unknown
Due 19 June 1987
Resolved 19 June 1987
Fire Fighting
Issued 26 June 1986
Resolved
REMOVE DRY CHEMICAL ENGINE ROOM FLOODING SYSTEM AND INSTALL CO2 FLOODING SYSTEM OR REMOVE DRY CHEMICAL FLOODING SYSTEM AND INSTALL TWO PORTABLE FIRE EXTINGUISHERS (B-II) OUTSIDE THE ENGINE ROOM.
Condition: Unknown
Due 26 June 1986
Resolved 26 June 1986
Engineering
Issued 26 June 1986
Resolved
EXTEND THE EXHAUST DUCT FOR THE ENGINE ROOM VENTILATION TO A POINT NEAR THEBOTTOM OF THE COMPARTMENT WHERE NORMAL WATER IN THE BILGE WILL NOT BE TRAPPED. THE DUCT SHALL BE OF RIGID PERMANENT CONSTRUCTION AND REASONABLY GASTIGHT.
Condition: Unknown
Due 26 June 1986
Resolved 26 June 1986
Construction/Loadline
Issued 6 June 1986
Resolved
CROP TO GOOD WOOD AND SCARF NEW WOOD ON FOUR CABIN SIDE VERTICAL SUPPORTS.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Electrical
Issued 6 June 1986
Resolved
SECURE ALL LOOSE ELECTRICAL WIRES IN ENGINEROOM.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Lifesaving
Issued 6 June 1986
Resolved
PROVIDE FIVE ADDTIONAL ADULT LIFE PRESERVERS - PASSENGER CAPACITY IS REDUCED TO 145 UNTIL THE ADDITIONAL PRESERVERS ARE ON BOARD.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Engineering
Issued 6 June 1986
Resolved
SECURE OIL PRESSURE GAUGE LINE LINE ON BOTH ENGINES.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986