MAURY USCG vessel records
← All vessels

MCDERMOTT DERRICK BARGE NO. 27

Built
1973
Last inspected
7 March 1997
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 7 March 1997
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 12 calendar years (1985–1997)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
10469 - Regulatory (Subpart C or D), Gross Ton 7633 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-47737
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 44

7 March 1997 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1431747
26 March 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843139
26 February 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153168
27 June 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1174242
2 November 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153842
31 August 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1143971
10 August 1993 Administrative
Administrative · Commandant (CG-CVC) · Activity 845787
23 July 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159094
22 July 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845003
12 June 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153402
2 April 1993 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 836241
16 July 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1262694
8 April 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943889
14 November 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244471
30 September 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932699
2 August 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249667
8 April 1991 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916852
27 March 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1228694
13 November 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1231698
31 October 1989 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1009153
12 September 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037747
12 August 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243242
5 May 1989 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037662
13 March 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 895550
14 February 1989 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1348007
16 September 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198674
21 August 1988 Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1043505
26 July 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339398
15 July 1987 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1022312
15 July 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1023707
15 July 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024224
19 May 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332551
27 April 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1014040
8 February 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015330
21 January 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1009066
6 January 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1311833
17 November 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015607
30 October 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019590
9 October 1985 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991469
24 September 1985 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991465
21 August 1985 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1298230
3 July 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 990726
1 April 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 982809
24 January 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1286689

Deficiency record · 90

Navigation
Issued 26 February 1995 Resolved
PROVIDE CURRENT COPIES OF 46 CFR 41-69, 46 CFR 90-139, AND 33 CFR 125-199.
Condition: Unknown
Due 15 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 26 February 1995 Resolved
PROVE PROPER OPERATION OF THE BOILER SAFETY VALVES, PRIOR TO OPERATION.
Condition: Unknown
Due 15 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 26 February 1995 Resolved
PROVE PROPER OPERATION OF WELDING GENERATORS INCLUDING ALARMS AND SHUTDOWNS.
Condition: Unknown
Due 15 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 26 February 1995 Resolved
REPLACE NEON LIGHT COVERS IN THE NATIONALS BERTHING SHOWER AREA.
Condition: Unknown
Due 15 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 26 February 1995 Resolved
PROVE AFT VENT POWER PANEL SHUTDOWN.
Condition: Unknown
Due 15 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 26 February 1995 Resolved
PROVIDE OIL TRANSFER PROCEDURES WHICH CONTAINS THE ELEMENTS LISTED IN 33 CFR 155.750.
Condition: Unknown
Due 15 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 26 February 1995 Resolved
CONDUCT HYDROSTATIC TEST, FIRESIDE, AND WATERSIDE EXAM OF FIRETUBE BOILER.
Condition: Unknown
Due 15 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 February 1995 Resolved
REPAIR AND PROVE PROPER OPERATION OF ALL VENT DAMPERS IN THE CLYDE CRANE.
Condition: Unknown
Due 15 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 26 February 1995 Resolved
PROVE ENGINE RUN LIGHT ON MAIN SWITCHBOARD.
Condition: Unknown
Due 15 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 26 February 1995 Resolved
PROVIDE GARBAGE LOGS AND WASTE MANAGEMENT PLAN IN ACCORDANCE WITH 33 CFR 151.57.
Condition: Unknown
Due 15 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 26 February 1995 Resolved
REPAINT AS NECESSARY IN A CONTRASTING COLOR DRAFT MARKS AND LOADLINE ON PORT SIDE OF VESSEL.
Condition: Unknown
Due 15 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 27 June 1994 Resolved
LABEL ALL UNMARKED BREAKERS IN MACHINERY SPACES ELECTRICAL PANELS.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Lifesaving
Issued 27 June 1994 Resolved
MAKE LIFERAFTS AVAILABLE FOR ANNUAL SERVICING AT CG APPRVD SVCING FACILITY NLT 1JUL94.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Fire Fighting
Issued 27 June 1994 Resolved
MAKE CO2 FIXED FIREFIGHTING SYSTEMS AVAILABLE FOR ANNUAL SERVICING AND TESTING BY DOT APPRVD FACILITY IN PRESENCE OF USCG INSPECTOR
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Fire Fighting
Issued 27 June 1994 Resolved
REFILL AND HYDROTEST PORTABLE FIRE EXTINGUISHERS (EXTRA) AS NEEDED OR REMOVE FROM VSL.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Fire Fighting
Issued 27 June 1994 Resolved
SEND B-V SEMIPORTABLE EXTINGUISHER TO DOT APPROVED FACILITY FOR 5 YR HYDROTESTING.
Condition: Unknown
Due 10 July 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 27 June 1994 Resolved
PROVER PROPER LAUNCHING AND OPERATION OF RESCUE BOAT
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Accommodation/Occupational Safety
Issued 27 June 1994 Resolved
PROVE PROPER OPERATION OF VESSEL'S SEWAGE SYSTEM OR MAKE PLAN SUBMITTAL FORUNAPPROVED SYSTEM IN USE.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Fire Fighting
Issued 27 June 1994 Resolved
PROPERLY MARK AND HYDROTEST ALL OIL TRANSFER HOSES.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Construction/Loadline
Issued 31 August 1993 Resolved
PROVIDE OCMI NEW YORK A COPY OF A COMPLETED REPORT FROM ABS CERTIFYING THATDISCREPANCIES IN BALLAST TANKS #5E AND 2E WERE COMPLETED.
Condition: Unknown
Due 31 August 1993
Resolved 31 August 1993
Lifesaving
Issued 12 June 1993 Resolved
PROVIDE DOCUMENTATION INCLUDING A STATEMENT FROM THE BARGE MASTER BRINGING LIFERAFT COMPLIMENT IN COMPLIANCE WITH APPROVED LIFESAVING PLAN THAT IS ON THE VESSEL (16-25 MAN). THIS ITEM TO BE COMPLETED NO LATER THAN 15SEP93.
Condition: Unknown
Due 12 June 1993
Resolved 12 June 1993
Lifesaving
Issued 12 June 1993 Resolved
PROVIDE ADDITIONAL LIFERAFT SO VESSEL'S LIFERAFT CAPACITY IS AT LEAST 405 PERSONS. THIS ITEM TO DONE BY NEXT DRYDOCK BUT NOT LATER THAN 30AUG93. UNTIL THIS REQUIREMENT IS CLEARED THE MAXIMUM NUMBER OF PERSONS ALLOWED IS LIMITED TO 263 PEOPLE._x001C_
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Engineering
Issued 12 June 1993 Resolved
REPLACE BOTH FUSIBLE PLUGS FOR THE AUXILIARY BOILER WITH ASME STANDARD PLUGS RATED FOR 275 PSI OR STEEL PLUG. GRADE A-53 OR A181 STEEL. ABOVE ITEMTO BE DONE IN THE PRESENCE OF A MARINE INSPECTOR AT THE NEXT DRYDOCK BUT NOT LATER THAN 30AUG93.
Condition: Unknown
Due 12 June 1993
Resolved 12 June 1993
Engineering
Issued 2 April 1993 Resolved
PERFORM OVERDUE HYDROSTATIC TEST OF AUXILIARY BOILER AND TEST SAFETY VALVE IN THE PRESENCE OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Engineering
Issued 2 April 1993 Resolved
HYDROSTATIC TEST OR INTERNALLY EXAMINE ALL AIR RECEIVERS AND TEST ALL RELIEF VALVES TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Electrical
Issued 2 April 1993 Resolved
PERFORM SAFETY TESTS ON ALL SHIP SERVICE GENERATORS TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 2 April 1993 Resolved
SEND OUT FOR ANNUAL SERVICING ALL (16) LIFERAFTS.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Fire Fighting
Issued 2 April 1993 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE FIXED FIREFIGHTING SYSTEM IN THE PRESENCE OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Fire Fighting
Issued 2 April 1993 Resolved
SEND OUT FOR HYDROSTATIC TESTS ALL OVERDUE PORTABLE FIRE EXTINGUISHERS._x001C_ _x001C_
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Navigation
Issued 2 April 1993 Resolved
CHANGE VESSEL'S HOMEPORT MARKINGS DUE TO REGIONALIZATION.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 2 April 1993 Resolved
CONDUCT FIRE & BOAT DRILL TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Engineering
Issued 8 April 1992 Resolved
MAKE PERMANENT REPAIRS TO THE JOHNSTON BOILER'S WASTED OUTED CASING IN WAY OF THE BOTTOM MID-SECTION AND FWD BOTTOM AREAS. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Fire Fighting
Issued 8 April 1992 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP'S RELIEF VALVE. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Engineering
Issued 8 April 1992 Resolved
MAKE PERMANENT REPAIRS TO THE REFRACTORY IN THE JOHNSTON BOILER IN WAY OF THE MID-BOTTOM AREA NEAR THE BURNERS. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Construction/Loadline
Issued 8 April 1992 Resolved
CROP & RENEW/MAKE PERMANENT REPAIRS TO CRACKS IN THE PORT & STBD SIDES OF THE JOHNSTON BOILER/MAIN DERRICK HOUSE. CRACKS LOCATED APPROXIMATELY 10FT AFT OF THE JOHNSTON BOILER HOUSE SLIDING DOORS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Lifesaving
Issued 2 August 1991 Resolved
PROVIDE ADDITIONAL LIFERAFTS WITH TOTAL CAPACITY OF 100 PERSONS (50 PORT AND 50 STARBOARD).
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Lifesaving
Issued 8 April 1991 Resolved
SUBMIT AN AMENDED VESSEL'S STATION BILL TO REFLECT CHANGE IN LIFERAFT NUMBER (FROM 16 TO 12 LIFERAFTS), TO INCLUDE LOCATION OF ALL LIFERAFTS.
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Electrical
Issued 12 August 1989 Resolved
INSTALL COVERSOR GUARDS ON ALL BUNK LIGHTS THROUGHOUT VESSEL IN ACCOMADATION CABINS.
Condition: Unknown
Due 12 August 1989
Resolved 12 August 1989
Navigation
Issued 12 August 1989 Resolved
REAMOVE ALL LOCAL GENERAL ALARM COMPACT METERS THAT WERE INSTALLED IN THE NORTH SEA AND THAT DO NOT AGREE WITH VESSEL FIRE AND SAFETY PLAN.
Condition: Unknown
Due 12 August 1989
Resolved 12 August 1989
Fire Fighting
Issued 12 August 1989 Resolved
PROVIDE TO OCMI NEW YORK A COPY OF THE FOAM ANALYSIS FOR FLIGHT DECK FOAM CONCENTRATE.
Condition: Unknown
Due 12 August 1989
Resolved 12 August 1989
Fire Fighting
Issued 12 August 1989 Resolved
PROVIDE TO OCMI NEW YORK A COPY OF A CG APPROVED FIRE AND SAFETY PLAN
Condition: Unknown
Due 12 August 1989
Resolved 12 August 1989
Unknown
Issued 21 August 1988 Resolved
PROVIDE AND INSTALL A DATA NAMEPLATE, COMPLETE WITH DATA, FOR THE KANAZAWA IRON WORKS CO., MAIN AIR RECEIVER.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Unknown
Issued 21 August 1988 Resolved
REMOVE THE PIPING LOCATED ON THE GENERATOR DAY TANK WHICH IS ACTIVE AS AN OVERFLOW/VENT LINE AND RUNS FROM THE TOP OF THE SOUNDING TUBE TO THE BILGE.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Accommodation/Occupational Safety
Issued 21 August 1988 Resolved
REMOVE OR MODIFY THE FLEXIBLE AIR CUSTION SUPPLY LINE TO THE TWO POTABLE WATER PRESSURE TANKS TO ENSURE THAT IT HAS A POSITIVE RELEASE FEATURE WHEN NOT IN USE.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Lifesaving
Issued 21 August 1988 Resolved
REPLACE 25 PERSON ELLIOT INFLATABLE LIFERAFT, SERIAL NO. 875, LOT NO. 186, THAT WAS CONDEMED BY COAST GUARD INSPECTOR AT LEO INTERNATIONAL, DUBAI, UNITED ARAB EMIRATES
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Fire Fighting
Issued 21 August 1988 Resolved
REVISE AND UPDATE THE CURRENT FIRE AND SAFETY PLAN AND SUBMIT TO OCMI FOR APPROVAL.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Construction/Loadline
Issued 21 August 1988 Resolved
PROVIDE OCMI NEW YORK WITH A COPY OF THE PHOTOGRAPHS TAKEN BY THE DIVERS OFTHE INTERIOR OF THE TWO SEA CHEST NOT INSPECTED DURING THE UNDERWATER SURVEY. THESE PHOTOS SHOULD BE CLEARLY MARKED INDICATING THE IDENTIFICATION OF THE SEA CHEST.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Construction/Loadline
Issued 21 August 1988 Resolved
PROVIDE OCMI NEW YORK WITH A COPY OF THE WRITTEN REPORT FROM OCEAN ENGINEERING ON THE UNDERWATER SURVEY OF THE HULL.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Electrical
Issued 21 August 1988 Resolved
PROVIDE A COPY OF THE DRAWINGS FOR THE PROPOSED RE-LOCATION OF THE GENERAL ALARM BATTERIES FROM THEIR PRESENT POSITION TO THE ON DECK BATTERY LOCKER.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Electrical
Issued 21 August 1988 Resolved
REPLACE THE BROKEN SIGHT GLASS PRESENTLY SOFT PATCHED WITH A NEW GLASS FOR THE NUMBER 3 SHIP SERVICE GENERATOR EXPANSION TANK.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Unknown
Issued 21 August 1988 Resolved
REMOVE THE EXISTING PLASTIC SIGHT GLASS ON THE FUEL OIL TANK FOR THE DOPE TANK AND REPLACE WITH A NEW GLASS.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Electrical
Issued 21 August 1988 Resolved
REMOVE THE ELECTRICALLY POWERED TV SIGNAL BOOSTER FROM ABOVE THE INTERIOR OVERHEAD BY LOCKER NUMBER 20 AND RELOCATE IT AS DISCUSSED WITH THE CHIEF ENGINEER.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Electrical
Issued 21 August 1988 Resolved
PROVIDE AND INSTALL A BATTERY COVER ON THE STARTING BATTERIES FOR THE DIESEL DRIVEN AIR COMPRESSOR LOCATED JUST FORWARD OF THE CLYDE CRANE.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Documentation
Issued 21 August 1988 Resolved
PROVIDE AND POST THE POLLUTION DISCHARGE WARNING PLACARD IN ACCORDANCE WITH33 CFR 155.450.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Electrical
Issued 21 August 1988 Resolved
REMOVE THE EXISTING NON-METTALIC CABLE TIES THROUGHOUT THE VESSEL AND REPLACE THEM AS NEEDED WITH SUITABLE METTALIC CABLE TIES.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Electrical
Issued 21 August 1988 Resolved
INSTALL SUITABLE BLANKS IN THE FOLLOWING ELECTRICAL PANELS TO COVER EXPOSEDCONDUCTORS AND CONNECTIONS: P428, FL100, ML100, ML3, AL4, 3-36-1, P42D, ANDAL-100.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Fire Fighting
Issued 15 July 1987 Resolved
PROVIDE HYDRO TESTED 100 LB CO2 CYLINDER AT PAINT LOCKER (1) ONE AND AT CRANE FIXED SYSTEM (1) ONE.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Engineering
Issued 15 July 1987 Resolved
DEMONSTRATE OPERATION OF THE TWO BOILER SAFETY RELIEF VALVES TO THE VESSELS MASTER.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Fire Fighting
Issued 27 April 1987 Resolved
PROVIDE A BV SEMI-PORTABLE FIRE EXTINGUISHER FOR THE CRANE BOILER ROOM AS REQUIRED BY 46 CFR 95.50-10(A).
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Lifesaving
Issued 30 October 1986 Resolved
SUBMIT PLANS FOR USCG APPROVAL FOR THE INSTALLATION OF A SECOND MEANS OF ESCAPE FROM THE GENERATOR ROOM.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Fire Fighting
Issued 30 October 1986 Resolved
PROVIDE AND INSTALL A USCG APPROVED BV HOSE REEL FIRE EXTINGUISHER FOR BOILER ROOM.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Construction/Loadline
Issued 24 September 1985 Resolved
PROVIDE OCMI NY VERIFICATION OF PLAN APPROVAL ON TWO NEWLY INSTALLED SEA CHESTS.
Condition: Unknown
Due 24 September 1985
Resolved 24 September 1985
Unknown
Issued 24 January 1985 Resolved
HYDROSTATICALLY TEST THE CO2 BOTTLES FOR THE FOLLOWING FIXED CO2 SYSTEMS; STARBOARD WINCH ROOM AND GENERATOR ROOM.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
REINSTALL A USCG APPROVED 25 MAN INFLATABLE LIFERAFT AT STATION NO. 16.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
PROVIDE ILLUMINATION SERVED FROM THE EMERGENCY POWER SOURCE FOR ALL LIFE- RAFT LAUNCHING STATIONS.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
SUBMITT DRAWINGS FOR USCG APPROVAL FOR THE HELICOPTER DECK FOAM PROTECTION SYSTEM.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
WEIGH THE CO2 CYLINDERS, TEST THE FLEXIBLE CONNECTIONS, SHUTDOWNS, AND ALARMS FOR THE FOLLOWING FIXED CO2 SYSTEMS; PAINT LOCKER, PORT AND STBD. WINCH ROOMS, GENERATOR ROOM, AND DERRICK.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
THE DRYDOCK EXTENSION REQUESTED WILL NOT BE GRANTED UNTIL ALL OUTSTANDING REQUIREMENTS HAVE BEEN SATISFACTORILY CORRECTED. THE DRYDOCK IS OVERDUE AND THE VESSEL SHALL BE MADE AVAILABLE FOR DRYDOCKING IMMEDIATELY.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
PROVIDE 34 ADDITIONAL USCG APPROVED PFD'S WITH REFLECTIVE MATERIAL, WHISTLES, LIGHTS AND STENCILED WITH THE VESSEL NAME.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
PROVIDE COPIES OF THE TEST AND INSPECTION RECORDS FOR THE PORT AND STBD 65 TON AMERICAN CRANES.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
PROVIDE COPIES OF THE SPECIFICATION DATA AND CERTIFICATION FOR THE DECOMPRESSION CHAMBER NO. BIAA 8357.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
MAKE ALL PRESSURE VESSELS AND THEIR RELIEF VALVES AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
PROVIDE 34 ADDITIONAL USCG APPROVED PFD'S WITH REFLECTIVE MATERIAL, WHISTLES, LIGHTS AND STENCILED WITH THE VESSEL NAME.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
REPAIR THE COMBUSTIBLE GAS AND OXYGEN LEVEL INDICATOR.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
POST A REVISED USCG APPROVED FIRE FIGHTING AND LIFESAVING PLAN SHOWING ALL INSTALLED EQUIPMENT.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
SERVICE THE INFLATABLE LIFERAFTS AT THE FOLLOWING LIFERAFT STATIONS:1,2,3, 6,7,8,9,10,11,12,13,14, AND 15. LIFERAFTS ARE TO BE SERVICED AT A USCG APPROVED SERVICING FACILITY AND WITNESSED BY A USCG INSPECTOR.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
THE 900 GALLON FUEL OIL DAY TANK IN THE AFTER MACHINERY ROOM DRAIN VALVE FLANGE SHALL BE CAPPED.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
PLACE PERSONNEL PROTECTION GUARDS OVER THE DRIVE CHAINS TO BOTH DRYERS IN THE LAUNDRY ROOM.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
PROVIDE ADDITIONAL CERTIFICATED LIFEBOATMEN AS REQUIRED TO MAN ALL REQUIREDLIFERAFTS.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
REPAIR THE RELIEF VALVE TO THE AUXILIARY FIRE PUMP AND SET TO 125 PSI.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
THE AFTER MACHINERY ROOM INBOARD BULKHEAD PIPE PENETRATION OVER THE WATER TIGHT DOOR IS TO BE MADE WATER TIGHT AND THE DOOR IS TO BE REPAIRED SO THATIT IS MADE WATER TIGHT.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
REPLACE THE GASKET ON THE WATER TIGHT DOOR TO THE PORT FORWARD WINCH ROOM.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
REPAIR THE EMERGENCY GENERATOR ENGINE HIGH JACKET WATER AND LOW LUBRICATINGOIL SAFETY DEVICES.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
SERVICE ALL HAND PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
REPLACE ALL HAND HELD ROCKET FLARES WITH USCG APPROVED FLARES.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
REPAIR THE FOLLOWING GENERAL ALARM BELLS; LOWER LEVEL PASSAGEWAY AFT BULK- HEAD BY THE PAINT LOCKER, GENERATOR COMPARTMENT FLASHING RED LIGHT, ALL 6 BELLS ON THE MAIN DECK, PORT AND STARBOARD WINCH COMPARTMENT FORWARD BULKHEAD.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
INSTALL ADDITIONAL GENERAL ALARM BELLS IN THE FOLLOWING AREAS; CLYDE CRANE COMPARTMENT, AFTER PORT AND STARBOARD EXTERIOR OF STRUCTURE AND PIPE TUNNELAREA. INSTALL RED FLASHING LIGHTS IN THE MACHINERY SPACES.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
REINSTALL THE RESCUE BOAT RADIAL DAVIT.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
PLACE NONCONDUCTIVE FLOOR COVERING AROUND THE CLYDE CRANE ELECTRICAL SWITCH BOARD.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 24 January 1985 Resolved
THE MAIN FIRE PUMP DISCHARGE PIPING TO THE FIRST CHECK VALVE IS DETERIORATED AND SHALL BE RENEWED IN KIND AND HYDROSTATICALLY TESTED TO A A MINIMUM OF 150 PSI.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.