← All vessels
MCDERMOTT DERRICK BARGE NO. 27
MCDERMOTT DERRICK BARGE NO. 27 is a 1973 industrial vessel. The Coast Guard has recorded 44 inspections since 1985, most recently in March 1997, along with 90 deficiencies.
Records from 1985 to 1997. Most recent: inspection, 7 March 1997.
- Built
- 1973
- Last inspected
- 7 March 1997
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 90 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
552816
47737
Flag
UNITED STATES
—
Maury page id
psix-47737
Inspections, by type
…with no type recorded8
Years with a record
12 calendar years (1985–1997)
The 44 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it10469 - Regulatory (Subpart C or D), Gross Ton
7633 - Regulatory (Subpart C or D), Net Ton
7633 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
KUBKMMSI not assigned · cancelled · compulsorily equipped · granted 14 February 1995, cancelled 15 December 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 44
7 March 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1431747
26 March 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843139
26 February 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153168
27 June 1994
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1174242
2 November 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153842
31 August 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1143971
10 August 1993
Administrative
Administrative · Commandant (CG-CVC) · Activity 845787
23 July 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159094
22 July 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845003
12 June 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153402
2 April 1993
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 836241
16 July 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1262694
8 April 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943889
14 November 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244471
30 September 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932699
2 August 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249667
8 April 1991
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916852
27 March 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1228694
13 November 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1231698
31 October 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1009153
12 September 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037747
12 August 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243242
5 May 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037662
13 March 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 895550
14 February 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1348007
16 September 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198674
21 August 1988
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1043505
26 July 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339398
15 July 1987
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1022312
15 July 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1023707
15 July 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024224
19 May 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332551
27 April 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1014040
8 February 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015330
21 January 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1009066
6 January 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1311833
17 November 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015607
30 October 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019590
9 October 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991469
24 September 1985
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991465
21 August 1985
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1298230
3 July 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 990726
1 April 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 982809
24 January 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1286689
Deficiency record · 90
Navigation
Issued 26 February 1995
Resolved
PROVIDE CURRENT COPIES OF 46 CFR 41-69, 46 CFR 90-139, AND 33 CFR 125-199.
Engineering
Issued 26 February 1995
Resolved
PROVE PROPER OPERATION OF THE BOILER SAFETY VALVES, PRIOR TO OPERATION.
Electrical
Issued 26 February 1995
Resolved
PROVE PROPER OPERATION OF WELDING GENERATORS INCLUDING ALARMS AND SHUTDOWNS.
Accommodation/Occupational Safety
Issued 26 February 1995
Resolved
REPLACE NEON LIGHT COVERS IN THE NATIONALS BERTHING SHOWER AREA.
Electrical
Issued 26 February 1995
Resolved
PROVE AFT VENT POWER PANEL SHUTDOWN.
Unknown
Issued 26 February 1995
Resolved
PROVIDE OIL TRANSFER PROCEDURES WHICH CONTAINS THE ELEMENTS LISTED IN 33 CFR 155.750.
Engineering
Issued 26 February 1995
Resolved
CONDUCT HYDROSTATIC TEST, FIRESIDE, AND WATERSIDE EXAM OF FIRETUBE BOILER.
Deck/Cargo
Issued 26 February 1995
Resolved
REPAIR AND PROVE PROPER OPERATION OF ALL VENT DAMPERS IN THE CLYDE CRANE.
Electrical
Issued 26 February 1995
Resolved
PROVE ENGINE RUN LIGHT ON MAIN SWITCHBOARD.
Electrical
Issued 26 February 1995
Resolved
PROVIDE GARBAGE LOGS AND WASTE MANAGEMENT PLAN IN ACCORDANCE WITH 33 CFR 151.57.
Construction/Loadline
Issued 26 February 1995
Resolved
REPAINT AS NECESSARY IN A CONTRASTING COLOR DRAFT MARKS AND LOADLINE ON PORT SIDE OF VESSEL.
Lifesaving
Issued 27 June 1994
Resolved
LABEL ALL UNMARKED BREAKERS IN MACHINERY SPACES ELECTRICAL PANELS.
Lifesaving
Issued 27 June 1994
Resolved
MAKE LIFERAFTS AVAILABLE FOR ANNUAL SERVICING AT CG APPRVD SVCING FACILITY NLT 1JUL94.
Fire Fighting
Issued 27 June 1994
Resolved
MAKE CO2 FIXED FIREFIGHTING SYSTEMS AVAILABLE FOR ANNUAL SERVICING AND TESTING BY DOT APPRVD FACILITY IN PRESENCE OF USCG INSPECTOR
Fire Fighting
Issued 27 June 1994
Resolved
REFILL AND HYDROTEST PORTABLE FIRE EXTINGUISHERS (EXTRA) AS NEEDED OR REMOVE FROM VSL.
Fire Fighting
Issued 27 June 1994
Resolved
SEND B-V SEMIPORTABLE EXTINGUISHER TO DOT APPROVED FACILITY FOR 5 YR HYDROTESTING.
Lifesaving
Issued 27 June 1994
Resolved
PROVER PROPER LAUNCHING AND OPERATION OF RESCUE BOAT
Accommodation/Occupational Safety
Issued 27 June 1994
Resolved
PROVE PROPER OPERATION OF VESSEL'S SEWAGE SYSTEM OR MAKE PLAN SUBMITTAL FORUNAPPROVED SYSTEM IN USE.
Fire Fighting
Issued 27 June 1994
Resolved
PROPERLY MARK AND HYDROTEST ALL OIL TRANSFER HOSES.
Construction/Loadline
Issued 31 August 1993
Resolved
PROVIDE [name withheld] A COPY OF A COMPLETED REPORT FROM ABS CERTIFYING THATDISCREPANCIES IN BALLAST TANKS #5E AND 2E WERE COMPLETED.
Lifesaving
Issued 12 June 1993
Resolved
PROVIDE DOCUMENTATION INCLUDING A STATEMENT FROM THE BARGE MASTER BRINGING LIFERAFT COMPLIMENT IN COMPLIANCE WITH APPROVED LIFESAVING PLAN THAT IS ON THE VESSEL (16-25 MAN). THIS ITEM TO BE COMPLETED NO LATER THAN 15SEP93.
Lifesaving
Issued 12 June 1993
Resolved
PROVIDE ADDITIONAL LIFERAFT SO VESSEL'S LIFERAFT CAPACITY IS AT LEAST 405 PERSONS. THIS ITEM TO DONE BY NEXT DRYDOCK BUT NOT LATER THAN 30AUG93. UNTIL THIS REQUIREMENT IS CLEARED THE MAXIMUM NUMBER OF PERSONS ALLOWED IS LIMITED TO 263 PEOPLE._x001C_
Engineering
Issued 12 June 1993
Resolved
REPLACE BOTH FUSIBLE PLUGS FOR THE AUXILIARY BOILER WITH ASME STANDARD PLUGS RATED FOR 275 PSI OR STEEL PLUG. GRADE A-53 OR A181 STEEL. ABOVE ITEMTO BE DONE IN THE PRESENCE OF A MARINE INSPECTOR AT THE NEXT DRYDOCK BUT NOT LATER THAN 30AUG93.
Engineering
Issued 2 April 1993
Resolved
PERFORM OVERDUE HYDROSTATIC TEST OF AUXILIARY BOILER AND TEST SAFETY VALVE IN THE PRESENCE OF AN ATTENDING MARINE INSPECTOR.
Engineering
Issued 2 April 1993
Resolved
HYDROSTATIC TEST OR INTERNALLY EXAMINE ALL AIR RECEIVERS AND TEST ALL RELIEF VALVES TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Electrical
Issued 2 April 1993
Resolved
PERFORM SAFETY TESTS ON ALL SHIP SERVICE GENERATORS TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Lifesaving
Issued 2 April 1993
Resolved
SEND OUT FOR ANNUAL SERVICING ALL (16) LIFERAFTS.
Fire Fighting
Issued 2 April 1993
Resolved
DEMONSTRATE THE PROPER OPERATION OF THE FIXED FIREFIGHTING SYSTEM IN THE PRESENCE OF AN ATTENDING MARINE INSPECTOR.
Fire Fighting
Issued 2 April 1993
Resolved
SEND OUT FOR HYDROSTATIC TESTS ALL OVERDUE PORTABLE FIRE EXTINGUISHERS._x001C_ _x001C_
Navigation
Issued 2 April 1993
Resolved
CHANGE VESSEL'S HOMEPORT MARKINGS DUE TO REGIONALIZATION.
Lifesaving
Issued 2 April 1993
Resolved
CONDUCT FIRE & BOAT DRILL TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Engineering
Issued 8 April 1992
Resolved
MAKE PERMANENT REPAIRS TO THE JOHNSTON BOILER'S WASTED OUTED CASING IN WAY OF THE BOTTOM MID-SECTION AND FWD BOTTOM AREAS. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_
Fire Fighting
Issued 8 April 1992
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP'S RELIEF VALVE. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Engineering
Issued 8 April 1992
Resolved
MAKE PERMANENT REPAIRS TO THE REFRACTORY IN THE JOHNSTON BOILER IN WAY OF THE MID-BOTTOM AREA NEAR THE BURNERS. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Construction/Loadline
Issued 8 April 1992
Resolved
CROP & RENEW/MAKE PERMANENT REPAIRS TO CRACKS IN THE PORT & STBD SIDES OF THE JOHNSTON BOILER/MAIN DERRICK HOUSE. CRACKS LOCATED APPROXIMATELY 10FT AFT OF THE JOHNSTON BOILER HOUSE SLIDING DOORS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Lifesaving
Issued 2 August 1991
Resolved
PROVIDE ADDITIONAL LIFERAFTS WITH TOTAL CAPACITY OF 100 PERSONS (50 PORT AND 50 STARBOARD).
Lifesaving
Issued 8 April 1991
Resolved
SUBMIT AN AMENDED VESSEL'S STATION BILL TO REFLECT CHANGE IN LIFERAFT NUMBER (FROM 16 TO 12 LIFERAFTS), TO INCLUDE LOCATION OF ALL LIFERAFTS.
Electrical
Issued 12 August 1989
Resolved
INSTALL COVERSOR GUARDS ON ALL BUNK LIGHTS THROUGHOUT VESSEL IN ACCOMADATION CABINS.
Navigation
Issued 12 August 1989
Resolved
REAMOVE ALL LOCAL GENERAL ALARM COMPACT METERS THAT WERE INSTALLED IN THE NORTH SEA AND THAT DO NOT AGREE WITH VESSEL FIRE AND SAFETY PLAN.
Fire Fighting
Issued 12 August 1989
Resolved
PROVIDE TO [name withheld] A COPY OF THE FOAM ANALYSIS FOR FLIGHT DECK FOAM CONCENTRATE.
Fire Fighting
Issued 12 August 1989
Resolved
PROVIDE TO [name withheld] A COPY OF A CG APPROVED FIRE AND SAFETY PLAN
Unknown
Issued 21 August 1988
Resolved
PROVIDE AND INSTALL A DATA NAMEPLATE, COMPLETE WITH DATA, FOR THE KANAZAWA IRON WORKS CO., MAIN AIR RECEIVER.
Unknown
Issued 21 August 1988
Resolved
REMOVE THE PIPING LOCATED ON THE GENERATOR DAY TANK WHICH IS ACTIVE AS AN OVERFLOW/VENT LINE AND RUNS FROM THE TOP OF THE SOUNDING TUBE TO THE BILGE.
Accommodation/Occupational Safety
Issued 21 August 1988
Resolved
REMOVE OR MODIFY THE FLEXIBLE AIR CUSTION SUPPLY LINE TO THE TWO POTABLE WATER PRESSURE TANKS TO ENSURE THAT IT HAS A POSITIVE RELEASE FEATURE WHEN NOT IN USE.
Lifesaving
Issued 21 August 1988
Resolved
REPLACE 25 PERSON ELLIOT INFLATABLE LIFERAFT, SERIAL NO. 875, LOT NO. 186, THAT WAS CONDEMED BY COAST GUARD INSPECTOR AT LEO INTERNATIONAL, DUBAI, UNITED ARAB EMIRATES
Fire Fighting
Issued 21 August 1988
Resolved
REVISE AND UPDATE THE CURRENT FIRE AND SAFETY PLAN AND SUBMIT TO OCMI FOR APPROVAL.
Construction/Loadline
Issued 21 August 1988
Resolved
PROVIDE [name withheld] WITH A COPY OF THE PHOTOGRAPHS TAKEN BY THE DIVERS OFTHE INTERIOR OF THE TWO SEA CHEST NOT INSPECTED DURING THE UNDERWATER SURVEY. THESE PHOTOS SHOULD BE CLEARLY MARKED INDICATING THE IDENTIFICATION OF THE SEA CHEST.
Construction/Loadline
Issued 21 August 1988
Resolved
PROVIDE [name withheld] WITH A COPY OF THE WRITTEN REPORT FROM OCEAN ENGINEERING ON THE UNDERWATER SURVEY OF THE HULL.
Electrical
Issued 21 August 1988
Resolved
PROVIDE A COPY OF THE DRAWINGS FOR THE PROPOSED RE-LOCATION OF THE GENERAL ALARM BATTERIES FROM THEIR PRESENT POSITION TO THE ON DECK BATTERY LOCKER.
Electrical
Issued 21 August 1988
Resolved
REPLACE THE BROKEN SIGHT GLASS PRESENTLY SOFT PATCHED WITH A NEW GLASS FOR THE NUMBER 3 SHIP SERVICE GENERATOR EXPANSION TANK.
Unknown
Issued 21 August 1988
Resolved
REMOVE THE EXISTING PLASTIC SIGHT GLASS ON THE FUEL OIL TANK FOR THE DOPE TANK AND REPLACE WITH A NEW GLASS.
Electrical
Issued 21 August 1988
Resolved
REMOVE THE ELECTRICALLY POWERED TV SIGNAL BOOSTER FROM ABOVE THE INTERIOR OVERHEAD BY LOCKER NUMBER 20 AND RELOCATE IT AS DISCUSSED WITH THE CHIEF ENGINEER.
Electrical
Issued 21 August 1988
Resolved
PROVIDE AND INSTALL A BATTERY COVER ON THE STARTING BATTERIES FOR THE DIESEL DRIVEN AIR COMPRESSOR LOCATED JUST FORWARD OF THE CLYDE CRANE.
Documentation
Issued 21 August 1988
Resolved
PROVIDE AND POST THE POLLUTION DISCHARGE WARNING PLACARD IN ACCORDANCE WITH33 CFR 155.450.
Electrical
Issued 21 August 1988
Resolved
REMOVE THE EXISTING NON-METTALIC CABLE TIES THROUGHOUT THE VESSEL AND REPLACE THEM AS NEEDED WITH SUITABLE METTALIC CABLE TIES.
Electrical
Issued 21 August 1988
Resolved
INSTALL SUITABLE BLANKS IN THE FOLLOWING ELECTRICAL PANELS TO COVER EXPOSEDCONDUCTORS AND CONNECTIONS: P428, FL100, ML100, ML3, AL4, 3-36-1, P42D, ANDAL-100.
Fire Fighting
Issued 15 July 1987
Resolved
PROVIDE HYDRO TESTED 100 LB CO2 CYLINDER AT PAINT LOCKER (1) ONE AND AT CRANE FIXED SYSTEM (1) ONE.
Engineering
Issued 15 July 1987
Resolved
DEMONSTRATE OPERATION OF THE TWO BOILER SAFETY RELIEF VALVES TO THE VESSELS MASTER.
Fire Fighting
Issued 27 April 1987
Resolved
PROVIDE A BV SEMI-PORTABLE FIRE EXTINGUISHER FOR THE CRANE BOILER ROOM AS REQUIRED BY 46 CFR 95.50-10(A).
Lifesaving
Issued 30 October 1986
Resolved
SUBMIT PLANS FOR USCG APPROVAL FOR THE INSTALLATION OF A SECOND MEANS OF ESCAPE FROM THE GENERATOR ROOM.
Fire Fighting
Issued 30 October 1986
Resolved
PROVIDE AND INSTALL A USCG APPROVED BV HOSE REEL FIRE EXTINGUISHER FOR BOILER ROOM.
Construction/Loadline
Issued 24 September 1985
Resolved
PROVIDE [name withheld] OF PLAN APPROVAL ON TWO NEWLY INSTALLED SEA CHESTS.
Unknown
Issued 24 January 1985
Resolved
HYDROSTATICALLY TEST THE CO2 BOTTLES FOR THE FOLLOWING FIXED CO2 SYSTEMS; STARBOARD WINCH ROOM AND GENERATOR ROOM.
Unknown
Issued 24 January 1985
Resolved
REINSTALL A USCG APPROVED 25 MAN INFLATABLE LIFERAFT AT STATION NO. 16.
Unknown
Issued 24 January 1985
Resolved
PROVIDE ILLUMINATION SERVED FROM THE EMERGENCY POWER SOURCE FOR ALL LIFE- RAFT LAUNCHING STATIONS.
Unknown
Issued 24 January 1985
Resolved
SUBMITT DRAWINGS FOR USCG APPROVAL FOR THE HELICOPTER DECK FOAM PROTECTION SYSTEM.
Unknown
Issued 24 January 1985
Resolved
WEIGH THE CO2 CYLINDERS, TEST THE FLEXIBLE CONNECTIONS, SHUTDOWNS, AND ALARMS FOR THE FOLLOWING FIXED CO2 SYSTEMS; PAINT LOCKER, PORT AND STBD. WINCH ROOMS, GENERATOR ROOM, AND DERRICK.
Unknown
Issued 24 January 1985
Resolved
THE DRYDOCK EXTENSION REQUESTED WILL NOT BE GRANTED UNTIL ALL OUTSTANDING REQUIREMENTS HAVE BEEN SATISFACTORILY CORRECTED. THE DRYDOCK IS OVERDUE AND THE VESSEL SHALL BE MADE AVAILABLE FOR DRYDOCKING IMMEDIATELY.
Unknown
Issued 24 January 1985
Resolved
PROVIDE 34 ADDITIONAL USCG APPROVED PFD'S WITH REFLECTIVE MATERIAL, WHISTLES, LIGHTS AND STENCILED WITH THE VESSEL NAME.
Unknown
Issued 24 January 1985
Resolved
PROVIDE COPIES OF THE TEST AND INSPECTION RECORDS FOR THE PORT AND STBD 65 TON AMERICAN CRANES.
Unknown
Issued 24 January 1985
Resolved
PROVIDE COPIES OF THE SPECIFICATION DATA AND CERTIFICATION FOR THE DECOMPRESSION CHAMBER NO. BIAA 8357.
Unknown
Issued 24 January 1985
Resolved
MAKE ALL PRESSURE VESSELS AND THEIR RELIEF VALVES AVAILABLE FOR INSPECTION.
Unknown
Issued 24 January 1985
Resolved
PROVIDE 34 ADDITIONAL USCG APPROVED PFD'S WITH REFLECTIVE MATERIAL, WHISTLES, LIGHTS AND STENCILED WITH THE VESSEL NAME.
Unknown
Issued 24 January 1985
Resolved
REPAIR THE COMBUSTIBLE GAS AND OXYGEN LEVEL INDICATOR.
Unknown
Issued 24 January 1985
Resolved
POST A REVISED USCG APPROVED FIRE FIGHTING AND LIFESAVING PLAN SHOWING ALL INSTALLED EQUIPMENT.
Unknown
Issued 24 January 1985
Resolved
SERVICE THE INFLATABLE LIFERAFTS AT THE FOLLOWING LIFERAFT STATIONS:1,2,3, 6,7,8,9,10,11,12,13,14, AND 15. LIFERAFTS ARE TO BE SERVICED AT A USCG APPROVED SERVICING FACILITY AND WITNESSED BY A USCG INSPECTOR.
Unknown
Issued 24 January 1985
Resolved
THE 900 GALLON FUEL OIL DAY TANK IN THE AFTER MACHINERY ROOM DRAIN VALVE FLANGE SHALL BE CAPPED.
Unknown
Issued 24 January 1985
Resolved
PLACE PERSONNEL PROTECTION GUARDS OVER THE DRIVE CHAINS TO BOTH DRYERS IN THE LAUNDRY ROOM.
Unknown
Issued 24 January 1985
Resolved
PROVIDE ADDITIONAL CERTIFICATED LIFEBOATMEN AS REQUIRED TO MAN ALL REQUIREDLIFERAFTS.
Unknown
Issued 24 January 1985
Resolved
REPAIR THE RELIEF VALVE TO THE AUXILIARY FIRE PUMP AND SET TO 125 PSI.
Unknown
Issued 24 January 1985
Resolved
THE AFTER MACHINERY ROOM INBOARD BULKHEAD PIPE PENETRATION OVER THE WATER TIGHT DOOR IS TO BE MADE WATER TIGHT AND THE DOOR IS TO BE REPAIRED SO THATIT IS MADE WATER TIGHT.
Unknown
Issued 24 January 1985
Resolved
REPLACE THE GASKET ON THE WATER TIGHT DOOR TO THE PORT FORWARD WINCH ROOM.
Unknown
Issued 24 January 1985
Resolved
REPAIR THE EMERGENCY GENERATOR ENGINE HIGH JACKET WATER AND LOW LUBRICATINGOIL SAFETY DEVICES.
Unknown
Issued 24 January 1985
Resolved
SERVICE ALL HAND PORTABLE FIRE EXTINGUISHERS.
Unknown
Issued 24 January 1985
Resolved
REPLACE ALL HAND HELD ROCKET FLARES WITH USCG APPROVED FLARES.
Unknown
Issued 24 January 1985
Resolved
REPAIR THE FOLLOWING GENERAL ALARM BELLS; LOWER LEVEL PASSAGEWAY AFT BULK- HEAD BY THE PAINT LOCKER, GENERATOR COMPARTMENT FLASHING RED LIGHT, ALL 6 BELLS ON THE MAIN DECK, PORT AND STARBOARD WINCH COMPARTMENT FORWARD BULKHEAD.
Unknown
Issued 24 January 1985
Resolved
INSTALL ADDITIONAL GENERAL ALARM BELLS IN THE FOLLOWING AREAS; CLYDE CRANE COMPARTMENT, AFTER PORT AND STARBOARD EXTERIOR OF STRUCTURE AND PIPE TUNNELAREA. INSTALL RED FLASHING LIGHTS IN THE MACHINERY SPACES.
Unknown
Issued 24 January 1985
Resolved
REINSTALL THE RESCUE BOAT RADIAL DAVIT.
Unknown
Issued 24 January 1985
Resolved
PLACE NONCONDUCTIVE FLOOR COVERING AROUND THE CLYDE CRANE ELECTRICAL SWITCH BOARD.
Unknown
Issued 24 January 1985
Resolved
THE MAIN FIRE PUMP DISCHARGE PIPING TO THE FIRST CHECK VALVE IS DETERIORATED AND SHALL BE RENEWED IN KIND AND HYDROSTATICALLY TESTED TO A A MINIMUM OF 150 PSI.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.