Inspection history · 20
12 March 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 908264
6 February 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1213059
16 March 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1351293
27 February 1989
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1272756
20 June 1988
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1348637
27 February 1987
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1324771
12 February 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1310744
30 January 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1001672
17 November 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324740
17 September 1986
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1006822
22 May 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1297827
22 October 1985
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 993931
14 August 1985
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1295071
6 August 1985
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 987358
29 July 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 984523
26 March 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 979870
21 October 1984
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1289085
16 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971718
4 October 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277616
16 January 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969752
Accommodation/Occupational Safety
Issued 27 February 1989
Resolved
INSTALL GUARDS ON ALL FAN BLADES ON THE MAIN DECK HOUSE BULKHEADS.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Navigation
Issued 27 February 1989
Resolved
DEMONSTRATE NAVIGATION LIGHTS AND NAV. LIGHT POWER PANEL ALARMS.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Electrical
Issued 27 February 1989
Resolved
REPAIR FIVE (5) FLUORESCENT LIGHT FIXTURES ON MAIN DECK AFT.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Electrical
Issued 27 February 1989
Resolved
REPLACE ALL WIRE NUT ELECTRICAL CONNECTIONS WITH LUG/TERMINAL CONNECTIONS; SPECIFICALLY, EMERGENCY ROOM OVERHEAD, VENT FAN MIDSHIP AFT PIPEWAY.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Accommodation/Occupational Safety
Issued 27 February 1989
Resolved
RENEW CABLE HANDRAILS.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Fire Fighting
Issued 27 February 1989
Resolved
DEMONSTRATE HELO-DECK FOAM SYSTEM.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Electrical
Issued 27 February 1989
Resolved
REPLACE LENS COVERS ON TWO MERCURY VAPOR FIXTURES STBD FWD BELOW THE HELO DECK.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Electrical
Issued 27 February 1989
Resolved
INSTALL LEAD LINING IN THE EMERGENCY GENERATOR BATTERY BOX.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Engineering
Issued 27 February 1989
Resolved
RENEW RELIEF VALVE (150 PSI) FOR STBD GANTRY CRANE AIR RECEIVER.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Engineering
Issued 27 February 1989
Resolved
DEMONSTRATE 15 PPM BILGE MONITOR OPERATION.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Fire Fighting
Issued 27 February 1989
Resolved
PROVIDE SERVICING REPORT OF FIRE DETECTION SYSTEM.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Engineering
Issued 27 February 1989
Resolved
MAKE PERMANENT REPAIR TO LEAKING TUBE CONNECTIONS AT AFT TUBE SHEET. HYDROSTATICALLY TEST BOILER UPON COMPLETION IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Engineering
Issued 20 June 1988
Resolved
PROVE OPERATION OF THE AUX BOILER AUTOMATION #1 BURNER & LOW WATER ALARMS.
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Fire Fighting
Issued 20 June 1988
Resolved
PROVIDE ONE 1 1/2" X 50' FIRE HOSE.
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Unknown
Issued 20 June 1988
Resolved
PRIOR TO OPERATION OF THE AUXILIARY BOILER, OPEN MOUNTS FOR EXAMINATION, DEMONSTRATE THE COMBUSTION CONTROLS, FLAME FAILURE AND LOW WATER ALARMS, AND TEST SAFETY VALVES.
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Unknown
Issued 22 May 1986
Resolved
PROVIDE CURRENTLY SERVICED LIFERAFT AND HYDROSTATIC RELEASE FOR LIFERAFT STATION #1.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
HYDROSTATICALLY TEST ALL PORTABLE CO2 CYLINDERS THAT ARE OVER 5 YEARS SINCETHEIR LAST HYDRO TEST.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
PROVIDE WRITTEN DESIGNATION OF A PERSON-IN-CHARGE.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
REPAIR THE FUEL OIL SHUT-OFF CABLE TO THE GENERATOR ROOM AND PROVE OPERATIONAL.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
PROVIDE 7 USCG APPROVED A-II FIRE EXTINGUISHERS FOR THE ACCOMODATION CORRIDORS, AS REQUIRED BY THE COI.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
ALTER OUTLETS OF FIRE HYDRANTS AT FIRE STATION #17 AND #20 TO POINT HORIZONTAL OR VERTICALLY DOWN.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
RECHARGE EMPTY 100 LB CO2 CYLINDER FOR THE STBD FORWARD SEMI-PORTABLE EXTINGUISHER IN THE CRANE MACHINERY SPACE. HYDROSTATICALLY TEST CYLINDER IF MORE THAN 5 YEARS SINCE THE LAST TEST.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
PROVIDE NOZZLE DISCHARGE HANDLE FOR THE PORT AFT SEMI-PORTABLE EXTINGUISHER IN THE CRANE MACHINERY SPACE.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
PROVIDE APPROVED PORTABLE FIRE EXTINGUISHER MOUNTING BRACKETS AS NOTED ON EXTINGUISHER APPROVAL LABEL DATA.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
PROVIDE CURRENT SERVICING CERTIFICATES FOR ALL LIFERAFTS.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
PROVIDE CURRENTLY SERVICED LIFERAFTS, AND SERVICING DOCUMENTATION FOR ALL LIFERAFT STATIONS.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
PROVIDE CURRENTLY SERVICED HYDROSTATIC RELEASE FOR LIFERAFT STATIONS #1, #9, AND #10.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
PROVIDE CURRENTLY SERVICED HYDROSTATIC RELEASE FOR LIFERAFT #9.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
PROPERELY TENSION ALL LIFERAFT HYDROSTATIC RELEASES.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
PROPERLY HOOKUP ALL LIFERAFT FLOAT FREE WEAK LINKS.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Unknown
Issued 22 May 1986
Resolved
STENCIL ALL LIFE PRESERVER LOCKERS IN THE ACCOMODATION CABINS.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Electrical
Issued 29 July 1985
Resolved
INSTALL PROTECTIVE GUARDS AROUND ALL EXPOSED MOVING PARTS ON GENERATOR PRIME MOVERS AND PROVIDE PROTECTIVE GUARD OR INSULATION ON ENGINE COOLING LINES TO PREVENT PERSONNEL INJURIES.
Condition: Unknown
Due 29 July 1985
Resolved 29 July 1985
Fire Fighting
Issued 29 July 1985
Resolved
REPLACE FIRE PUMP RELIEF VALVE WITH APPROVED RELIEF VALVE IN ACCORDANCE WITH 46 CFR 95.10-1(D).
Condition: Unknown
Due 29 July 1985
Resolved 29 July 1985
Unknown
Issued 26 March 1985
Resolved
EMBARKATION LADDERS SHALL BE PROVIDED AT EACH LIFERAFT LAUNCHING STATION.
Condition: Unknown
Due 26 March 1985
Resolved 26 March 1985
Unknown
Issued 26 March 1985
Resolved
GANTRY CRANES (2) SHALL BE TESTED AND CERTIFIED IN ACCORDANCE WITH 46 CFR 91.37.
Condition: Unknown
Due 26 March 1985
Resolved 26 March 1985
Unknown
Issued 26 March 1985
Resolved
SUBMIT DETAILS AND PLANS FOR THE INSTALLATION OF A FIXED FIRE FIGHTING SYSTEM IN THE MAIN CRANE MACHINERY SPACE. ONCE APPROVED, INSTALLATION SHALL BE ACCOMPLISHED WITHIN A TIME FRAME ESTABLISHED BY O.C.M.I. HONOLULU.
Condition: Unknown
Due 26 March 1985
Resolved 26 March 1985
Unknown
Issued 26 March 1985
Resolved
SUBMIT PLANS AND DETAILS FOR THE PROPOSED INSTALLATION OF A NEW FIREPUMP TOREPLACE THE PRESENTLY INSTALLED "INDAG" PUMP.
Condition: Unknown
Due 26 March 1985
Resolved 26 March 1985
Unknown
Issued 26 March 1985
Resolved
INSTALL A REVERSE POWER RELAY FOR THE NUMBERS 1 AND 2 AUXILIARY GENERATORS.
Condition: Unknown
Due 26 March 1985
Resolved 26 March 1985
Unknown
Issued 26 March 1985
Resolved
SUBMIT DETAILS AND PLANS FOR THE INSTALLATION OF A GENERAL ALARM SYSTEM IN THE MAIN CRANE CAB AND IT'S MACHINERY SPACE.
Condition: Unknown
Due 26 March 1985
Resolved 26 March 1985
Unknown
Issued 21 October 1984
Resolved
NEW INSTALLATION FIRE NOZZELS ARE TO BE OF AN APPROVED TYPE.
Condition: Unknown
Due 21 October 1984
Resolved 21 October 1984
Unknown
Issued 21 October 1984
Resolved
SUBMIT TO THIS OFFICE THE FIRE CONTROL AND SAFETY DRAWINGS FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 21 October 1984
Resolved 21 October 1984
Unknown
Issued 21 October 1984
Resolved
THE FOLLOWING GENERAL ALARM BELLS ARE TO BE MADE OPERABLE: MAIN DECK AT FR 13 STBD AFT; CRANE TUB FR 22 PORT ; MAIN DECK FIRE STATION # 15 BELL LOCATION AND MOVIE ROOM.
Condition: Unknown
Due 21 October 1984
Resolved 21 October 1984
Unknown
Issued 21 October 1984
Resolved
ALL NON-APPROVED FOREIGN MANUFACTURED FIRE EXTINGUISHERS ARE TO BE REPLACEDWITH A TYPE SUITABLE FOR ITS EXTENDED USE AN UL APPROVED FOR MARINE USE.
Condition: Unknown
Due 21 October 1984
Resolved 21 October 1984