MAURY USCG vessel records Sign in
← All vessels

LADY ALDERBROOK

LADY ALDERBROOK is a 1998 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 1998, most recently in July 2025, along with 26 deficiencies.

Records from 1998 to 2025. Most recent: inspection, 25 July 2025.

Built
1998
Last inspected
25 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM4596
477416
Flag
UNITED STATES
367376910
Maury page id
psix-477416

Inspections, by type

Years with a record 21 calendar years (1998–2025)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)52.8 ft × 21.0 ft × 4.8 ft
Registered tonnagegross 22 / net 15
ITC dimensions (L × B × D)52.8 ft × 21.0 ft × 4.8 ft
ITC tonnagegross 22 / net 15
BuilderRON J. DERONDEN-POS · COOS BAY, OR, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portUNION, WA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 18 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Convention (Subpart B), Gross Ton
15 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM4596MMSI 367376910 · active · compulsorily equipped · granted 1 July 2021, expires 1 July 2031
WDE6176MMSI 367376910 · expired · compulsorily equipped · granted 13 September 2008, cancelled 17 November 2018
WDB8472MMSI 366959060 · expired · compulsorily equipped · granted 24 June 2004, cancelled 30 August 2014 · licensed under a name not among this hull’s recorded names (not shown)
WCY6123MMSI not assigned · expired · compulsorily equipped · granted 3 August 1998, cancelled 4 October 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 36

25 July 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8192213
11 July 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8204075
11 February 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8078308
14 June 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7931678
7 June 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7710993
6 January 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7618791
1 August 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7522121
14 June 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7476761
28 June 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7202197
26 February 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7151170
17 June 2020 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6962045
16 April 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6648865
29 January 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6616390
24 April 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6394032
10 April 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6121169
7 February 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6084016
12 May 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5876621
7 March 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4812067
6 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203232
23 February 2011 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3955448
25 September 2008 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3332227
29 July 2008 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3271866
19 June 2006 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2684863
18 October 2004 Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2221778
11 December 2003 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1962816
24 September 2003 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1891162
9 May 2002 In-Service Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1615044
28 August 2001 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1072623
18 June 2001 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1068161
27 September 2000 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 824823
5 September 2000 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369819
29 July 2000 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 821055
25 July 2000 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1056176
19 July 2000 Inclining Experiment
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1051829
31 August 1999 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1361122
28 August 1998 Hull Examination · Initial Certification · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1472137

Deficiency record · 26

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2025 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI...include, but not limited to:...alterations affecting stability. A fabric shade sail was installed on the upper open passenger deck which alters the vessel's wind profile and, consequently, its stability. The shade sail must be removed until a stability test can be completed using a wind profile that includes the sail.
Action required: 10 - Deficiency Rectified
Due 25 July 2025
Resolved 25 July 2025
Resolution: Sade sail removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 July 2025 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection.
Action required: 10 - Deficiency Rectified
Resolved 11 July 2025
Resolution: CONDUCTED FULL COI EXAM AND ISSUED VALID COI
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 June 2024 Resolved
Aft stbd ring life bouy plug failure and dryrot of 60' line. Fwd ring life bouy - becketed lifeline dryrotting. Upper deck floating waterlight intermittent functionality.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2024
Resolved 1 July 2024
Resolution: Aft and bow ring life buoys replaced new. Floating water light repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 June 2024 Resolved
Unplugged penetration (wire) in bulkhead between engine compartment and center void.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2024
Resolved 28 June 2024
Resolution: Bulkhead penetration mechanically plugged. Received via emailed photo.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 7 June 2023 Resolved
Vessel is using members of the lodge to suppliment as crew. All members or deckhands used in emergency procedures need to be apart of the consortium.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2023
Resolved 22 July 2025
Resolution: Legacy def, last COI insp stated DAPI program checked w/ no issues. Closing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2023 Resolved
Missing 1 adult PFD as per number required on the COI
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Vessel showed proof of new life jacket purchase and placed into service in the front stb stowage compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 June 2023 Resolved
Vessel did not have required number of smoke distress signals onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Ownew showed proof of purchase for new distress signals. Both day and night.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2023 Resolved
Child life jacket stowage compartment needs to say 6 as per the COI. It currently reads 5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Vessel showed proof of updating current sign to reflect 6 child PFD's.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 7 June 2023 Resolved
On the bow there are 2 deck lights that do not have covers over the glass globe.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Vessel purchased and installed 02 glass globe covers to put them in compliance.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 June 2023 Resolved
Fire extinguisher in the closet inside of the accommodation space needs to be mounted. It is currently just sitting in the closet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Vessel showed proof of installing a fire extinguisher bracket in the closet location.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 7 June 2023 Resolved
Vessel has plastic trash cans throughout the vessel that need to be replaced.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Vessel purchased and installed new metal trash cans.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 June 2021 Resolved
FCC Station License and Safety Radio Cert. are expired. Renew station license and have installation certified. 47 CFR 80.13 47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2021
Resolved 14 June 2022
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 June 2021 Resolved
MMSI number is not programmed into the vessels DSC radio. Program DSC radio with vessels assigned MMSI number from the current effective FCC Station License. 46 CFR184.502 47 CFR 80.103
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2021
Resolved 14 June 2022
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 June 2021 Resolved
DSC equipped radio is not receiving position data from installed navigation equipment. FCC regulations require this connection if navigational equipment is installed. Properly connect DSC radio to installed GPS. 46 CFR 184.502 47 CFR 80.1085(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2021
Resolved 14 June 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2021 Resolved
Fuel tanks are fitted with ball valves and clear plastic tubing as a means of determining the quantity of fuel in the tank. Tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant material, adequately protected from mechanical damage, and provided at the tank connections with devices that will automatically close in the event of rupture of the gauge or gauge lines. Until this discrepancy is corrected these valves shall remain closed. Prior to each trip with passengers the status of these valves will be verified by licensed crew and a log entry made. 46 CFR 182.440(a)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2021
Resolved 14 June 2022
Lifesaving › Hand Flares › Expired
Issued 12 May 2016 Resolved
Vessel required to have either 6 red hand flares or 3 red hand flares and 3 orange smokes. Provide proof of required amount on board.
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 17 May 2016
Resolution: 02 new flares were procured so vessel now has the required 06 red hand flares on board.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 October 2004 Resolved
Provide proof of drug testing program enrollment for all deckhands. 46 CFR 16. Complete prior to sailing with more than 6 passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2004
Resolved 15 November 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 October 2004 Resolved
Provide proof of Certificate of Documentation. 46CFR67.7 Complete no later than 18Nov04.
Due 18 November 2004
Resolved 15 November 2004
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 18 October 2004 Resolved
Install a fixed firefighting system that will meet or exceed the capacity of the engine room. The capacity of the current fixed firefighting system (1275 cubic feet) in the engine room does not adequately meet the capacity of the engine room. Based on calculations the capacity of the engine room is 1388 cubic feet.
Due 20 January 2005
Resolved 21 January 2005
Documentation › Certificates/Documents
Issued 24 September 2003 Resolved
Provide copy of FCC Safety Certificate. Correct to the satisfaction of attending Marine Inspector. LEGACY COMPONENT DESC: FCC Safety Certificate
Condition: Unknown
Due 24 October 2003
Resolved 15 October 2003
Resolution: Based on a fax receipt of the required certificate, this item has been cleared.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 24 September 2003 Resolved
Hydrostatically test 1 B-II CO2 portable fire extinguisher. Loaner of equivalent size and capacity req'd during service. Correct to the satisfaction of attending Marine Inspector. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 10 October 2003
Resolved 15 October 2003
Resolution: Based on a copy of service receipt dated 10/15/2003, this item has been cleared.
Electrical
Issued 28 August 1998 Resolved
Replace plastic wire run hangers with metal ones.
Condition: Unknown
Due 9 September 1998
Resolved 18 September 1998
Electrical
Issued 28 August 1998 Resolved
Hardwire various components in machinery space. Refrigerator, HW heater, Air compressor, packing coolant pump.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Engineering
Issued 28 August 1998 Resolved
Relocate fuel fills to main deck. Vapors/liquid not allowed to be able to leak to inside of vessel as per 46cfr182.445d&e. Fill presently in machinery space.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 28 August 1998 Resolved
Disable the locks or remove the locks for the lifejacket stowage on upper deck.
Condition: Unknown
Due 9 September 1998
Resolved 14 September 1998
Unknown
Issued 28 August 1998 Resolved
Provide proof of drug testing program.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.