Records from 1998 to 2025. Most recent: inspection, 25 July 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
25 July 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8192213
11 July 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8204075
11 February 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8078308
14 June 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7931678
7 June 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7710993
6 January 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7618791
1 August 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7522121
14 June 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7476761
28 June 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7202197
26 February 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7151170
17 June 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6962045
16 April 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6648865
29 January 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6616390
24 April 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6394032
10 April 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6121169
7 February 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6084016
12 May 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5876621
7 March 2014
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4812067
6 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203232
23 February 2011
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3955448
25 September 2008
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3332227
29 July 2008
Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3271866
19 June 2006
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2684863
18 October 2004
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2221778
11 December 2003
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1962816
24 September 2003
COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1891162
9 May 2002
In-Service Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1615044
28 August 2001
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1072623
18 June 2001
Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1068161
27 September 2000
Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 824823
5 September 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369819
29 July 2000
Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 821055
25 July 2000
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1056176
19 July 2000
Inclining Experiment
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1051829
31 August 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1361122
28 August 1998
Hull Examination · Initial Certification · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1472137
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2025
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI...include, but not limited to:...alterations affecting stability. A fabric shade sail was installed on the upper open passenger deck which alters the vessel's wind profile and, consequently, its stability. The shade sail must be removed until a stability test can be completed using a wind profile that includes the sail.
Action required: 10 - Deficiency Rectified
Due 25 July 2025
Resolved 25 July 2025
Resolution: Sade sail removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 July 2025
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection.
Action required: 10 - Deficiency Rectified
Resolved 11 July 2025
Resolution: CONDUCTED FULL COI EXAM AND ISSUED VALID COI
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 June 2024
Resolved
Aft stbd ring life bouy plug failure and dryrot of 60' line. Fwd ring life bouy - becketed lifeline dryrotting. Upper deck floating waterlight intermittent functionality.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2024
Resolved 1 July 2024
Resolution: Aft and bow ring life buoys replaced new. Floating water light repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 June 2024
Resolved
Unplugged penetration (wire) in bulkhead between engine compartment and center void.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2024
Resolved 28 June 2024
Resolution: Bulkhead penetration mechanically plugged. Received via emailed photo.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 7 June 2023
Resolved
Vessel is using members of the lodge to suppliment as crew. All members or deckhands used in emergency procedures need to be apart of the consortium.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2023
Resolved 22 July 2025
Resolution: Legacy def, last COI insp stated DAPI program checked w/ no issues. Closing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2023
Resolved
Missing 1 adult PFD as per number required on the COI
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Vessel showed proof of new life jacket purchase and placed into service in the front stb stowage compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 June 2023
Resolved
Vessel did not have required number of smoke distress signals onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Ownew showed proof of purchase for new distress signals. Both day and night.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2023
Resolved
Child life jacket stowage compartment needs to say 6 as per the COI. It currently reads 5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Vessel showed proof of updating current sign to reflect 6 child PFD's.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 7 June 2023
Resolved
On the bow there are 2 deck lights that do not have covers over the glass globe.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Vessel purchased and installed 02 glass globe covers to put them in compliance.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 June 2023
Resolved
Fire extinguisher in the closet inside of the accommodation space needs to be mounted. It is currently just sitting in the closet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Vessel showed proof of installing a fire extinguisher bracket in the closet location.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 7 June 2023
Resolved
Vessel has plastic trash cans throughout the vessel that need to be replaced.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 28 June 2023
Resolution: Vessel purchased and installed new metal trash cans.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 June 2021
Resolved
FCC Station License and Safety Radio Cert. are expired. Renew station license and have installation certified.
47 CFR 80.13
47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2021
Resolved 14 June 2022
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 June 2021
Resolved
MMSI number is not programmed into the vessels DSC radio. Program DSC radio with vessels assigned MMSI number from the current effective FCC Station License.
46 CFR184.502
47 CFR 80.103
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2021
Resolved 14 June 2022
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 June 2021
Resolved
DSC equipped radio is not receiving position data from installed navigation equipment. FCC regulations require this connection if navigational equipment is installed. Properly connect DSC radio to installed GPS.
46 CFR 184.502
47 CFR 80.1085(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2021
Resolved 14 June 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2021
Resolved
Fuel tanks are fitted with ball valves and clear plastic tubing as a means of determining the quantity of fuel in the tank. Tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant material, adequately protected from mechanical damage, and provided at the tank connections with devices that will automatically close in the event of rupture of the gauge or gauge lines. Until this discrepancy is corrected these valves shall remain closed. Prior to each trip with passengers the status of these valves will be verified by licensed crew and a log entry made.
46 CFR 182.440(a)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2021
Resolved 14 June 2022
Lifesaving › Hand Flares › Expired
Issued 12 May 2016
Resolved
Vessel required to have either 6 red hand flares or 3 red hand flares and 3 orange smokes. Provide proof of required amount on board.
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 17 May 2016
Resolution: 02 new flares were procured so vessel now has the required 06 red hand flares on board.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 October 2004
Resolved
Provide proof of drug testing program enrollment for all deckhands. 46 CFR 16. Complete prior to sailing with more than 6 passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2004
Resolved 15 November 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 October 2004
Resolved
Provide proof of Certificate of Documentation. 46CFR67.7 Complete no later than 18Nov04.
Due 18 November 2004
Resolved 15 November 2004
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 18 October 2004
Resolved
Install a fixed firefighting system that will meet or exceed the capacity of the engine room. The capacity of the current fixed firefighting system (1275 cubic feet) in the engine room does not adequately meet the capacity of the engine room. Based on calculations the capacity of the engine room is 1388 cubic feet.
Due 20 January 2005
Resolved 21 January 2005
Documentation › Certificates/Documents
Issued 24 September 2003
Resolved
Provide copy of FCC Safety Certificate. Correct to the satisfaction of attending Marine Inspector. LEGACY COMPONENT DESC: FCC Safety Certificate
Condition: Unknown
Due 24 October 2003
Resolved 15 October 2003
Resolution: Based on a fax receipt of the required certificate, this item has been cleared.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 24 September 2003
Resolved
Hydrostatically test 1 B-II CO2 portable fire extinguisher. Loaner of equivalent size and capacity req'd during service. Correct to the satisfaction of attending Marine Inspector. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 10 October 2003
Resolved 15 October 2003
Resolution: Based on a copy of service receipt dated 10/15/2003, this item has been cleared.
Electrical
Issued 28 August 1998
Resolved
Replace plastic wire run hangers with metal ones.
Condition: Unknown
Due 9 September 1998
Resolved 18 September 1998
Electrical
Issued 28 August 1998
Resolved
Hardwire various components in machinery space. Refrigerator, HW heater, Air compressor, packing coolant pump.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Engineering
Issued 28 August 1998
Resolved
Relocate fuel fills to main deck. Vapors/liquid not allowed to be able to leak to inside of vessel as per 46cfr182.445d&e. Fill presently in machinery space.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 28 August 1998
Resolved
Disable the locks or remove the locks for the lifejacket stowage on upper deck.
Condition: Unknown
Due 9 September 1998
Resolved 14 September 1998
Unknown
Issued 28 August 1998
Resolved
Provide proof of drug testing program.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998