← All vessels
POSEIDON'S MISTRESS
POSEIDON'S MISTRESS is a 1973 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 1982, most recently in September 2001, along with 14 deficiencies and 1 casualty investigation in 2001.
Records from 1982 to 2001. Most recent: inspection, 30 September 2001.
- Built
- 1973
- Last inspected
- 30 September 2001
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2001
Identity
552890
WTT6061
47745
Flag
UNITED STATES
366641820 (licence lapsed)
Maury page id
psix-47745
Inspections, by type
…with no type recorded6
Years with a record
15 calendar years (1982–2001)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WTT6061MMSI 366641820 · expired · compulsorily equipped · granted 3 January 1995, cancelled 5 March 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 24
30 September 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 108278
8 September 2000
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1054068
25 November 1997
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1471332
18 June 1997
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1111088
11 December 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419694
21 December 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419544
7 November 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419543
2 September 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 868883
20 September 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1179417
12 August 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1154636
5 August 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 844115
29 October 1992
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1157824
31 March 1992
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 947614
4 September 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 940410
4 September 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1251983
20 August 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1253678
24 May 1990
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 905236
1 February 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 904965
12 January 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 908056
22 August 1988
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1037480
12 October 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 974516
18 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968226
13 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274050
17 February 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964677
Deficiency record · 14
Engineering
Issued 2 September 1994
Resolved
INSTALL PILOT HOUSE CONTROL AS DEFINED BY 46 CFR 175.10-29.
Fire Fighting
Issued 12 August 1993
Resolved
PROVIDE TWO(2)FIRE NOZZLES THAT HAVE A 1/2 INCH SOLID STREAM ORIFICE OR A COMBINATION NAVY ALL PURPOSE NOZZLE MEETING 46 CFR 162.027-6. SEE 46 CFR 181.15-10(d)(2).
Fire Fighting
Issued 12 August 1993
Resolved
PROVIDE DOCUMENTATION THAT LINED FIRE HOSE CONFORMS TO UNDERWRITERS LABORATORIES, INC. STANDARD 19 OR FEDERAL SPECIFICATION ZZ-H-451E. SEE 46 CFR 181.15-10(d)(1).
Engineering
Issued 12 August 1993
Resolved
PROVE OPERATION OF OVERSPEED TRIP TO PORT SHIP SERVICE GENERATOR.
Electrical
Issued 12 August 1993
Resolved
INSTALL HIGH DIELECTRIC INSULATING MAT FOR IN FRONT OF SWITCHBOARD.
Accommodation/Occupational Safety
Issued 12 August 1993
Resolved
REPLACE CRACKED WINDOW ON PORT SIDE UPPER ACCOMMODATION SPACE.
Accommodation/Occupational Safety
Issued 12 August 1993
Resolved
REPAIR VENT COVER BRACKET FOR STBD POWER ENGINE ROOM VENT COVER ON MAIN DECK.
Lifesaving
Issued 12 August 1993
Resolved
REBUILD BOTH LIFE FLOATS TO MEET STANDARDS SET FORTH IN 46 CFR 160.027.
Navigation
Issued 12 August 1993
Resolved
RENEW ALL NAVIGATIONAL LIGHTS TO MEET STANDARDS SET FORTH IN 72 COLREGS.
Fire Fighting
Issued 12 August 1993
Resolved
PROVE OPERATION OF FIRE PUMP. THE MIMIMUM CAPACITY OF THE POWER FIRE PUMP SHALL BE 50 GALLONS PER MINUTE AT A PRESSUREOF NOT LESS THAN 60 PSI AT THEPUMP OUTLET. SEE 46CFR181.10-1(c).
Electrical
Issued 12 August 1993
Resolved
PROVIDE DIRECTORY OF CIRCUITS FOR EACH ELECTRICAL DISTRIBUTION PANEL AND LABEL ALL MOTOR CONTROLLER WITH PURPOSE OR FUNCTION.
Electrical
Issued 12 August 1993
Resolved
REMOVE 110 VAC PANEL AND WIRING IN UPPER ACCOMMODATION SPACE.
Electrical
Issued 12 August 1993
Resolved
RELAMP GENERATOR AVAILABLE LIGHTS ON SWITCHBOARD.
Engineering
Issued 12 August 1993
Resolved
REMOVE PETCOCKS FROM ALL FUEL OIL FILTERS ON DIESEL ENGINES AND INSTALL TAPER PLUGS
Casualty record · 1
30 September 2001Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 108278
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.