COASTAL 7001-SB is a 1973 tank barge. The Coast Guard has recorded 41 inspections since 1980, most recently in December 1998, along with 14 deficiencies.
Records from 1980 to 1998. Most recent: inspection, 29 December 1998.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it814 - Regulatory (Subpart C or D), Gross Ton 814 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
Prior to 25NOV97 the above noted barge must have it's cargo tank tops gauged and a copy of the gauging report issued to the cognizant U.S. Coast Guard inspector. After gauging, any low gauging points must be renewed. Barge may operate during this time.
Condition: Unknown
Due 25 November 1997
Resolved 9 November 2006
Construction/Loadline
Issued 17 October 1988Resolved
MAKE AND MAINTAIN TEMPORARY REPAIRS TO 4 FOOT FRACTURE IN DECK GUNNEL SIX FEET FORWARD OF STERN PORT SIDE AT NEXT GAS FREEING AND/OR PRIOR TO 17 FEBRUARY 1989.
Condition: Unknown
Due 17 October 1988
Resolved 17 October 1988
Deck/Cargo
Issued 17 October 1988Resolved
CONDUCT OPERATIONAL TEST OF THERMAL FLUID HEATER ALARMS AND SHUTDOWNS.
Condition: Unknown
Due 17 October 1988
Resolved 17 October 1988
Electrical
Issued 3 September 1986Resolved
REPAIR THERMAL FLUID HEATER LOW FLOW CUT OUT SWITCH AND CONDUCT AN OPERATIONAL TEST TO SHOW PROPER OPERATION.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Deck/Cargo
Issued 3 September 1986Resolved
REPAIR/REPLACE ROTTED STANDPIPES FOR P/V VALVES ON #1 & #2 CARGO TANKS.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Electrical
Issued 3 September 1986Resolved
INSTALL ELECTRICAL JUNCTION BOX COVER FOR THERMAL FLUID HEATER LOW LEVEL CUT OUT SWITCH.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Electrical
Issued 3 September 1986Resolved
INSTALL ELECTRICAL JUNCTION BOX COVER FOR THERMAL FLUID HEATER HI TEMP CUT OUT SWITCH.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Electrical
Issued 3 September 1986Resolved
INSTALL ELECTRICAL JUNCTION BOX COVER FOR THERMAL FLUID HEATER BLOWER MOTOR
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Engineering
Issued 3 September 1986Resolved
OPEN THERMAL FLUID HEATER FOR COAST GUARD INTERNAL EXAM.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Engineering
Issued 3 September 1986Resolved
REPAIR LOW LEVEL CONTROL RESET SWITCH ON THERMAL FLUID HEATER CONTROL BOX.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Electrical
Issued 3 September 1986Resolved
REPAIR THERMAL FLUID HEATER LOW LEVEL CUT OUT SWITCH AND CONDUCT AN OPERATIONAL TEST TO SHOW PROPER OPERATION.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Deck/Cargo
Issued 2 October 1985Resolved
P/V VALVE ON #2 CARGO TANK WAS LOOSENED FROM VENT LINE DUE TO CORRODED THREADS, AND PLUGGGED WITH CARGO RESIDUE.
Condition: Unknown
Due 2 October 1985
Resolved 2 October 1985
Deck/Cargo
Issued 2 October 1985Resolved
ONE CARGO HOSE ONBOARD WAS MARKED "BAD", ANOTHER HAD TEARS IN THE COVER. REMOVE BOTH OF THESE HOSES FROM THE VESSEL.
Condition: Unknown
Due 2 October 1985
Resolved 2 October 1985
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.