MAURY USCG vessel records Sign in
← All vessels

NORDIC JUPITER

NORDIC JUPITER is a 1998 tank ship. The Coast Guard has recorded 27 inspections since 1998, most recently in March 2018, along with 10 deficiencies and 6 operational controls.

Records from 1998 to 2018. Most recent: inspection, 19 March 2018.

Built
1998
Last inspected
19 March 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9160205 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
477518
Flag
MARSHALL ISLANDS
—
Maury page id
psix-477518

Inspections, by type

…with no type recorded12
Years with a record 12 calendar years (1998–2018)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it142604 - Displacement, Ton
157411 - Dead Weight, Ton
81565 - Regulatory (Subpart C or D), Gross Ton
81565 - Convention (Subpart B), Gross Ton
49488 - Regulatory (Subpart C or D), Net Ton
49488 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

19 March 2018 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6373288
6 January 2012 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4219965
19 March 2009 COC-TVE Renew · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3436719
12 December 2007 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3114032
13 February 2007 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2871458
31 May 2006 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2666567
9 January 2006 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2563602
22 November 2005 MARPOL Annex V Examination · Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2538959
2 November 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2526787
20 August 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2468885
5 July 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2426616
29 May 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2371616
5 April 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2327098
9 January 2005 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2271369
8 January 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2271922
5 January 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2269680
5 January 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2270746
3 January 2005 ISPS II Exam · COC-TVE Annual
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2268109
2 December 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1957147
2 December 2003 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1957568
12 November 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1703119
3 October 2001 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1074859
19 August 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 280798
19 August 2000 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1361663
18 August 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 505905
18 August 1999 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 778747
2 August 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 418834

Deficiency record · 10

Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2007 Resolved
Starboard railing; there are numerous broken welds throughout approximately 20 feet or rail directly adjacent to manifold area. Repair to the satisfaction of class within 30 days-Condition of class issued until drydock.
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 13 December 2007
Resolution: Condition of class imposed until 13MAY08.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2007 Resolved
Three horizontal railings have numerous cracked welds at the deck; port side and just aft of manifold near the lifering with the waterlight. Repair to the satisfaction of class with 30 days. Condition of class has been issued until drydock.
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 13 December 2007
Resolution: Condition of class imposed until 13MAY08.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 12 December 2007 Resolved
Span gas for oxygen analyzer for IGS is expired. Replace prior to departure to the satisfaction of CG.
Action required: 705 - Other - as specified
Resolved 13 December 2007
Resolution: Received delivery confirmation of span gas.
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 December 2007 Resolved
Electrical wiring box for exhaust fan for Emergency Diesel Generator is broken and exposed to weather. Repair to the satisfaction of class within 30 days.
Action required: 705 - Other - as specified
Due 13 January 2008
Resolved 13 December 2007
Resolution: Condition of class imposed until 13JAN08.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 12 December 2007 Resolved
Vapor Control piping has numerous soft patches, many of which are leaking. Repair prior to departure to the satisfaction of class. Condition of class has been issued-satisfactory temporary repairs to be made by 13JAN08, permanent repairs to be made at drydock or no later than 13MAY08
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 13 December 2007
Resolution: Condition of class imposed until 13JAN08.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 December 2007 Resolved
Numerous broken and corroded steel cable supports along length of cargo deck. Cable being held by nylon rope. Repair to the satisfaction of class within 30 days.
Action required: 705 - Other - as specified
Due 13 January 2008
Resolved 13 December 2007
Resolution: Condition of class imposed until 13JAN08.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 12 December 2007 Resolved
Soft patch on fuel oil bunkering line has a small leak; port side just forward of superstructure. Repair to the satisfaction of class within 30 days. Condition of class for permanent repairs has been issued until drydock.
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 13 December 2007
Resolution: Condition of class imposed until 13MAY08.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 22 November 2005 Resolved
Exhaust Intake pipe into scrubber is leaking water. Repair to the satisfaction of class prior to next U.S. port. Until repaired maintain adequate watch of scrubber while operating IGS and log in appropriate log book.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 January 2006
Resolution: Received Class survey report attesting satisfactory repair to IGS gas inlet piping.
Navigation › Collision/Grounding Avoidance › Radar
Issued 5 July 2005 Resolved
SECTOR DELAWARE BAY ISSUED LOD 34-05 TO M/T SACRAMENTO FOR INOP X-BAND RADAR
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2005
Resolved 7 July 2005
Resolution: X-BAND RADAR WAS TESTED AND INSPECTED TO THE SATISFACTION OF THE REPAIR TECH. SECTOR DELAWARE BAY RESCINDED LOD 34-05
Deck/Cargo
Issued 2 August 1998 Resolved
Prior to the operation of the COW system in U.S. waters other than for effectiveness certification and no later than 01AUG99, provide class society report attesting to compliance of the COW system with Marpol Annex I Regulation 13.
Condition: Unknown
Due 20 August 1999
Resolved 20 August 1999

Ownership record