MAURY USCG vessel records
← All vessels

COASTAL 7006-T

COASTAL 7006-T is a 1974 tank barge. The Coast Guard has recorded 52 inspections since 1984, most recently in August 1997, along with 6 deficiencies.

Records from 1984 to 1997. Most recent: inspection, 10 August 1997.

Built
1974
Last inspected
10 August 1997
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 10 August 1997
…with no type recorded33
Operational controls None recorded without a removal date
Years with a record 13 calendar years (1984–1997)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-47755

Documentation record

Tonnage as PSIX records it1710 - Regulatory (Subpart C or D), Gross Ton
1710 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

52 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 5 vessels inspected with it, by name and date; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

Inspection history · 52

10 August 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117486
5 December 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 203846
5 December 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 754105
5 December 1995 Permit to Proceed
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1355568
21 April 1995 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 469260
4 January 1995 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1171581
7 December 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 702647
23 November 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 702644
14 November 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 531443
11 October 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 702642
6 October 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 171681
9 September 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 461920
28 August 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 504278
11 July 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 469683
21 June 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 59046
21 June 1994 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1030023
17 December 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 702632
13 December 1993 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1159507
12 December 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 102870
22 July 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 464438
11 July 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 51736
19 April 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 177784
7 April 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 513391
5 April 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 449470
13 January 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 830146
13 January 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1133210
5 January 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1139063
8 December 1992 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 527799
4 January 1992 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 470291
3 January 1992 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1259678
3 November 1991 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 933804
2 November 1991 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 533538
10 September 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 345836
19 February 1991 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 465013
11 January 1991 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1227017
16 October 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 927647
26 September 1990 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 442131
15 August 1990 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1212844
4 January 1990 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1239959
5 September 1989 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1194021
27 May 1989 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 468832
1 September 1988 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1350135
12 July 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 469781
17 February 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1330280
4 February 1988 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1326164
28 October 1987 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1327122
10 September 1986 COI Inspection · Credit Drydock
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1001827
5 March 1986 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1296828
10 September 1985 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1300520
21 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289047
27 October 1984 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 436736
18 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974251

Deficiency record · 6

Deck/Cargo
Issued 5 January 1993 Resolved
PROVE PROPER OPERATION OF AUDIO AND VISUAL ALARMS ON THE THERMAL FLUID HEATER.(WITH EXCEPTION OF AUDIO/VISUAL ALARMS TFH TESTED SAT ON 05JAN93)
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Construction/Loadline
Issued 3 November 1991 Resolved
DISCHARGE CARGO AND PRIOR TO NEXT LOADING, GAS FREE AND MAKE PERMANENT REPAIRS TO FRACTURE IN #3 PORT WING VOID. WHEN REPAIRS COMPLETE PRESENT VOID FOR INSPECTION BY A COAST GUARD MARINE INSPECTOR, AND AIR TEST VOID.
Condition: Unknown
Due 8 November 1991
Resolved 4 November 1991
Construction/Loadline
Issued 16 October 1990 Resolved
CROP AND RENEW SIDE SHELL PLATE IN WAY OF PORT SIDE BILGE KNUCKLE, WING VOIDS 4, 5, AND 6. CROP AND RENEW ALL AFFECTED INTERNAL FRAMING MEMBERS.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Documentation
Issued 4 February 1988 Resolved
NOTIFY MARINE SAFETY OFFICE ST. LOUIS, MO UPON ARRIVAL. TELEPHONE AREA CODE [phone withheld].
Condition: Unknown
Due 4 February 1988
Resolved 4 February 1988
Construction/Loadline
Issued 4 February 1988 Resolved
PROCEED TO ST. LOUIS (OR NEAREST PRACTICAL DRY DOCK) TO GAS FREE VESSEL ANDPLACE ON DRYDOCK. VESSEL IS NOT TO TAKE ON OR TRANSFER CARGO AT ANY TIME.
Condition: Unknown
Due 4 February 1988
Resolved 4 February 1988
Construction/Loadline
Issued 4 February 1988 Resolved
AFFECT PERMANENT REPAIRS TO HEADLOG, BOW RAKE AND DOUBLE BOTTOMS.
Condition: Unknown
Due 4 February 1988
Resolved 4 February 1988

Ownership record