← All vessels
TAHOE PARADISE
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southwest District (CGD-SW) · Other hulls named TAHOE PARADISE
TAHOE PARADISE is a 1998 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1998, most recently in May 2025, along with 129 deficiencies, 3 operational controls and 1 casualty investigation in 2015.
Records from 1998 to 2025. Most recent: operational control imposed, 13 May 2025.
- Built
- 1998
- Last inspected
- 13 May 2025
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 129 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2015
Identity
1068455
WCY8027
477989
Flag
UNITED STATES
—
Maury page id
psix-477989
Inspections, by type
…with no type recorded4
Years with a record
26 calendar years (1998–2025)
The 46 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)72.5 ft × 18.0 ft × 5.3 ft
Registered tonnagegross 98 / net 89
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTSS FAB INC/SKIPPERLINER · LACROSSE, WI, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSOUTH LAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Simplified, Gross Ton
89 - Simplified, Net Ton
89 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCY8027MMSI not assigned · expired · compulsorily equipped · granted 17 December 1998, cancelled 21 February 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 46
13 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8118779
15 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7920740
29 August 2023
Drydock Exam · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7775991
18 May 2023
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7685938
13 April 2023
Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7673029
4 May 2022
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7436223
26 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7182761
13 July 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7005457
10 May 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681505
24 May 2018
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6428206
21 May 2018
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6417052
3 May 2017
Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138357
2 May 2016
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6036632
19 December 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5784701
19 December 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5824301
18 December 2015
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5784826
17 July 2015
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5183992
10 June 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4877740
18 July 2012
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4391687
12 June 2012
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4342289
22 July 2011
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4097631
4 May 2009
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3495070
14 April 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3450058
10 June 2008
Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3224913
15 May 2008
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3202109
9 April 2008
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3177109
30 May 2007
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2952216
30 May 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2981171
24 April 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2629570
28 March 2006
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2611555
3 May 2005
COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2355180
13 August 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2165473
11 May 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2064796
20 May 2003
Hull Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779768
30 April 2003
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1783739
7 June 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1624199
16 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075579
9 July 2001
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384821
26 July 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1365900
6 July 2000
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 820338
13 March 2000
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1047603
26 July 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1391069
10 December 1998
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 811280
10 July 1998
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1112174
10 July 1998
Initial Certification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1378750
24 June 1998
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1470462
Deficiency record · 129
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2025
Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Strainers must be the type of opening on top for cleaning screens. A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Flame screen on the generator fuel filter is missing.
46 CFR 182.455(b)(6)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 May 2025
Resolved
A hatch cover must:
(1) Have securing devices; and
(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Engine room hatch cover does not have captive device.
46 CFR 179.360(b)(2)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2025
Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. The stability letter was not onboard the vessel.
46 CFR 176.306
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2025
Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. The light lanyards are frayed and not long enough.
46 CFR 180.175(f)(4)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2025
Resolved
If the vessel carries more than one life float or buoyant apparatus in a group with each group secured by a single painter:(3) Each life float and buoyant apparatus must be individually attached to the painter by a line meeting § 180.175(f)(3) (ii), (iii), and (iv) and long enough that each life float or buoyant apparatus can float without contacting any other life float or buoyant apparatus in the group. MI identified only 2 of the 4 lifefloat painter lines were connected to the weak link.
46 CFR 180.137(e)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 15 May 2024
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Vessel’s life floats were found ripped due to bird activity. Vessel must repair the life floats to the satisfaction of the Marine Inspector.
46CF185.604(i)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2024
Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. The life buoy on the bow was found degraded. Replace the life buoy to the satisfaction of the Marine Inspector.
46CFR180.70(a)(3)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2024
Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Vessel was found with sagging and worn insulation in the engine room. Repair the insulation to the satisfaction of the Marine Inspector.
46CFR177.405(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 May 2024
Resolved
A hatch exposed to the weather must be watertight. Hatches leading into the engine room that are exposed to the weather were found not watertight. Repair the hatches leading to the engine room to be able to meet the requirements of being watertight to the satisfaction of the Marine Inspector.
46CFR179.3609(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 May 2024
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Vessel’s Fuel Oil space has 3 penetrations in the watertight bulkheads that are not properly sealed, and are now not watertight. Seal the penetrations in the fuel oil space to the satisfaction of the Marine Inspector.
46CFR179.320(a)
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 15 May 2024
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Vessel was missing the required maximum passengers signage as required on their top deck. Install the proper signage to the satisfaction of the Marine Inspector.
46CFR185.602(g)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2024
Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel was found with a plastic trashcan in the main deck galley space. Remove the plastic trashcan to the satisfaction of the Marine Inspector.
46CFR177.405(f)
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 May 2024
Resolved
Equipment specifications for life floats and buoyant apparatus. The equipment required for life floats and buoyant apparatus must meet the following specifications:(2) Paddle. Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Starboard aft life float has one paddle that is not lashed. Properly lash the paddle to the satisfaction of the Marine Inspector.
46CFR180.175(f)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Vessels life buoys were found without retroreflective tape. Install retroreflective tape to the satisfaction of the Marine Inspector.
46CF185.604(i)
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 May 2024
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. All paddles were found without proper vessel name markings. Mark all paddles with the vessel’s name to the satisfaction of the Marine Inspector.
46CFR185.604(g)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 May 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel was found with a broken first aid kit. Replace the first aid kit to the satisfaction of the Marine Inspector.
46CFR184.710
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 18 May 2023
Resolved
All griddles, broilers and deep fat fryers must be witted with a grease extraction hood in compliance 46 CFR 181.425. The Griddle in the galley is missing a grease extraction hood and must be removed or tagged out.
46 CFR 181.405(b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2023
Resolved
Electrical equipments used in the following location must be dripproof: location exposed to wet conditions. The vessel's void space below the the galley had an electrical switch that is not dripproof.
46 CFR 183.210(a)(3)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2023
Resolved
The installation of portable fire extinguisher must be to the satisfaction of the OCMI. The vessel's two portable fire extinguishers were not mounted to a frame.
46 CFR 181.520
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 18 May 2023
Resolved
Vessel is inspected for compliance with standards required by this subchapter. Equipments not covered by this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessel's ladder to the lifefloat shall be permanently secured.
46 CFR 176.800(a)
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 May 2023
Resolved
Each item of survival craft equipment must be of a good quality and efficient for the purpose it's intended to serve. The vessel's lifefloat paddles were missing the vessel's name.
46 CFR 180.175(a)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 May 2023
Resolved
At each subsequent inspection for certification shall be prepared to test navigational lights. Vessel's stern light was inoperable. Vessel limited to daytime operations.
46 CFR 176.816
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 May 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems.Lifefloats on board are no longer in serviceable condition. Vessel is limited to 1NM from shore until replacement is made.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2022
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including testing of each firehose to a test pressure equivalent to its maximum service pressure. Firehose on aft main deck sustained multiple punctures and is no longer serviceable.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2021
Resolved
Survival craft equipment. The floating waterlight must be attached around the body of the life float or buoyant apparatus. Re-rig waterlight line.
46 CFR 180.75 (f) (4)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2021
Resolved
Survival craft equipment. Each life float must fitted with two paddles. Replace missing paddles (8)
46 CFR 180.75 (d)
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 April 2021
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Repair damaged life floats on starboard side.
46 CFR 180.75 (a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 July 2020
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Discovered no bilge strainer present in the #2 compartment. 46 CFR 182.510 (b)
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 July 2020
Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Vessel listed rescue boats in emergency instructions when not one is utilized onboard.46 CFR 185.510(b)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 July 2020
Resolved
At each vessel inspection all observed unsafe practices must be corrected. Unsecured oxygen bottle discovered in the pilot house. 46 CFR 176.830(a)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 July 2020
Resolved
There shall be aspirin, ammonia inhalant, iodine applicators, and eye wash in the first-aid kit. Expired aspirin, ammonia inhalants, iodine, and eyewash in first-aid kit. 46 CFR 184.710 & 46 CFR 160.041
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 13 July 2020
Resolved
Man overboard drills shall be logged for review by the Coast Guard upon request. The drill entry shall include date of the drill and training and general description of the drill scenario and training topics. No documented MOB drills onboard. 46 CFR 185.520(f)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 July 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. No updated charts onboard. 46 CFR 184.420
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 July 2020
Resolved
As appropriate for the intended voyage, a vessel must carry an adequate and up-to-date Coast Guard Light List. No updated light list onboard. 46 CFR121.420(a)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 July 2020
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Worn labeling identified on ring buoy. 46 CFR 185.604(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019
Resolved
Each distribution terminal part of a conductor must be made within an enclosure. A hot lead (indication by "Circuit Alert GB" non contact voltage detector) was found about 4" above the main power panel while vessel was plugged into shore power (panel interlock sat, in shore power position).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary to safety under normal and emergency conditions, and progect passengers, crew, other persons and the vessel from electrical hazards. Portable water sump pump was found used as galley grey water transfer and storage pump using extension cords.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary to safety under normal and emergency conditions. Several "y" and butt splices were found in 110V AC electric wire and several unused runs of 110V AC electric wire found in vicinity of galley service space entry ladder.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019
Resolved
Protection from wet and corrosive environments. Electrical equipment on a vessel must be installed and maintained to provide services necessary to safety under normal and emergency conditions. 12 V sensor connection at fuel tank (fuel tank space) and two 12 V connections - one open and unused, one with twist locks at 12V bilge pump near bilge level (centerline galley services space).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2019
Resolved
Lifesaving equipment markings. The number and identification of the items stowed inside, and their sizes, must be marked clearly in legible letters and numbers on each container for life jackets. Letters and numbers must be two inches high, symbols four inches square. PFD storage was not marked, and is inside of open deck furniture.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2019
Resolved
Stowage of lifejackets. Each child life jackeet must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Childrens PFD's were stored in open deck furniture, not marked and mixed with adult PFD's.
Lifesaving › Lifefloat › Float-free Link
Issued 24 May 2018
Resolved
Procure new life-float weak link with proper documentation.
Stability › Watertight Integrity › General
Issued 24 May 2018
Resolved
Make hatches to the laz/engine room watertight & secure with chain.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 May 2017
Resolved
Vessel missing 7 of required 14 child life jackets. Vessel restricted to carrying 7 child passengers.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 May 2017
Resolved
Light not attached to life buoy.
Electrical › Electric Generation Source (service) › Generator
Issued 18 December 2015
Resolved
During operation the alternator bearing seized, the attached belt heated and started a fire. Prove proper operation of ship service generator after repoer/new install.
Electrical › Electrical Distribution System (service) › Cable
Issued 17 July 2015
Resolved
In the bar hold the sewage pump is loosely mounted and wiring under strain and not properly supported. Properly mount pump base, install longer conductor to eliminat strain and properly support wiring.
Electrical › Electrical Distribution System (service) › Conductor
Issued 17 July 2015
Resolved
Wiring for AC pump power box located in bar hold does not have strain relief at service entrance to box. Install strain relief and properly support wiring that is hanging loosely.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 17 July 2015
Resolved
The wiring conduit running from electrical distribution center through main deck into engine compartment above port generator is missing fire seal in transit block. Install proper fire seal to transit block.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 July 2015
Resolved
! life float water light found not to work. All 4 float lights for life floats need new attaching lines. Make float light operational (install new battery) and install new lanyards to all 4 float lights.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 July 2015
Resolved
The coffee maker in galley is mounted in a manner that pinches the cord and strains socket. Move coffee maker to eliminate kink in cord and allow plug to be strain free.
Documentation › Certificates/Documents › Stability Letter
Issued 17 July 2015
Resolved
The vessel stability letter is mounted under glass in passenger accommodation area on main deck below pilot house. Re-locate stability letter to suitable place in pilot house where it is available to operator.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 June 2014
Resolved
Install a corrosion resistant clip for water light.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 June 2014
Resolved
Install fastner for stbd MDE s/w strainer cap.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 10 June 2014
Resolved
Replace 4 buoyant apparatus water light batteries. Restricted to day time operations.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 June 2014
Resolved
Install new light bulb for aft main deck e-lighting
Deck/Cargo › Holds/Tanks › Hatch
Issued 10 June 2014
Resolved
Install new gasket for forpeak hatch.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 June 2012
Resolved
Install metallic supports spaced not more than 24 inches apart on all electrical cabling.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 13 June 2012
Resolved
Prove proper operation of main distribution panel shoretie/ gen interlock.
Engineering › Steering Gear System › Rudder
Issued 13 June 2012
Resolved
Provide repair proposal for damaged port rudder.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 13 June 2012
Resolved
Prove proper operation of port shaft seal.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 13 June 2012
Resolved
Provide two additional adult lifejackets as required by COI.
Lifesaving › Lifefloat › Paddle
Issued 13 June 2012
Resolved
Replace four sun damaged paddles on bouyant apparatus.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 13 June 2012
Resolved
Replace expired batteries on 2 waterlights on bouyant apparatus.
Construction/Loadline › Penetrations › Valve Flange
Issued 13 June 2012
Resolved
Prove watertight integrity of starboard main engine raw water intake through hull valve.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 June 2012
Resolved
Prove proper operation of anchor light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 June 2012
Resolved
Provide asprin, eye wash, and ammonia inhallents in first aid kit.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 13 June 2012
Resolved
Prove proper operation of engine room ventilation closures.
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011
Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2009
Resolved
Properly wire A/C pump in Void # 4.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 14 April 2009
Resolved
Properly secure A/C unit in void #4.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 April 2009
Resolved
Replace stern light bulb with proper bulb.
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 May 2008
Resolved
Vessel is restricted from carrying passengers as of 09 June 2008.
Construction/Loadline › Hull › Hull Plating
Issued 15 May 2008
Resolved
Vessel will be made ready for inspection on 10 June 2008.
Construction/Loadline › Hull › Hull Plating
Issued 15 May 2008
Resolved
USCG marine inspectors will conduct an out of the water hull exam on 10 June 2008.
Construction/Loadline › Hull › Hull Plating
Issued 15 May 2008
Resolved
Submit scope of work to the attending marine inspector after the vessel has been hauled out of the water.
Lifesaving › Lifefloat › Serviceable
Issued 9 April 2008
Resolved
Renew or repair life floats.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 April 2008
Resolved
Properly dead-end or connect wires in way of underneath console at operating station.
Lifesaving › Hand Flares › Storage
Issued 9 April 2008
Resolved
Provide approved storage for flares.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 April 2008
Resolved
Properly install and test fixed firefighting engine shut down to SSD generator. Vessel is restricted from operating generator with passengers on board.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 April 2008
Resolved
Provide current COD prior to carrying passengers for hire.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 April 2008
Resolved
Properly install life line to life ring.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 9 April 2008
Resolved
Properly install port side engine room vent closure.
Documentation › Logs/Records › Drug Test Records
Issued 17 March 2008
Resolved
Background history checks not being completed in accordance with 49 CFR 40.25.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
Company policy missing as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
MRO drug free determination before returning to work regulations not being followed as required in 49 CFR part 40; crewmember returned to work with only a letter from a SAP. Letter from MRO must be provided.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Documentation › Logs/Records › Drug Test Records
Issued 30 May 2007
Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Lifesaving › Lifefloat › Markings
Issued 30 May 2007
Resolved
Label stbd forward lifefloat paddle.
Lifesaving › Hand Flares › Expired
Issued 3 May 2005
Resolved
Renew 3 orange and 3 red hand flares.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 May 2005
Resolved
Install a waterlight with lanyard to the 22 passenger life float.
Lifesaving › Lifefloat › Paddle
Issued 3 May 2005
Resolved
Renew all the paddles for the 4 life floats. Properly label the vessel's name on each paddle and secure it to each life float.
Lifesaving › Lifefloat › Markings
Issued 3 May 2005
Resolved
Label the max passenger capacity for each life float.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 3 May 2005
Resolved
Post a life jacket donning placard on each deck.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 May 2005
Resolved
Properly separate children and adult PFDs.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 3 May 2005
Resolved
Properly store 8 adult PFDs.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 3 May 2005
Resolved
Tighten the port packing.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 3 May 2005
Resolved
Post the emergency broadcast placard.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 May 2005
Resolved
Prove proper operation of the port aft life float waterlight.
Engineering › Sea-water System (primary cooling)
Issued 18 May 2004
Resolved
Repair leak on stbd engine raw water cooling suction valve. LEGACY COMPONENT DESC: Pump
Electrical › Electrical Distribution System (service) › Cable
Issued 11 May 2004
Resolved
Repair power supply wire for sewege pump located in #4 compartment under bar; properly install plug with strain relief fitting, correct insulation damage at motor.
Accommodation/Occupational Safety › Cooking Systems
Issued 11 May 2004
Resolved
Remove from vessel spare sterno cooking cans stored in # 3 void. E-mailed a copy of CID Memo 1-03, Warming trays, to operator and required to give instruction to all personel on vessel that use this equipment. LEGACY COMPONENT DESC: Cooking Fuel
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 May 2004
Resolved
Operator shall provide generator operating instructions and training so that fixed fire fighting system is not placed into "OVER RIDE" condition at pilot house.
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 11 May 2004
Resolved
Properly seperate child sized life preservers from adult life preservers.
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 11 May 2004
Resolved
Properly label where passengers can easily identify the adult sized life preservers located under console area port and starboard of operating station.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2004
Resolved
Update first aid kit by replacing items that have passed experation date.
Lifesaving › Lifejacket/PFD (Type I)
Issued 20 May 2003
Resolved
Provide one additional child PFD as required by vessel's COI. Vessel is restricted from carrying more than 15 children until this requirement has been satisfied. LEGACY COMPONENT DESC: Quantity
Lifesaving › Lifejacket/PFD (Type I)
Issued 20 May 2003
Resolved
Provide six additional adult PFD's as required by vessel's COI. Vessel is restricted from carrying more than 143 passengers until this requirement has been satisfied. LEGACY COMPONENT DESC: Quantity
Lifesaving › Lifebuoys
Issued 20 May 2003
Resolved
Install corrosion resistant clip on lifering buoy water light lanyard per 46 CFR 180.70. LEGACY COMPONENT DESC: Stowage
Lifesaving › Buoyant Apparatus
Issued 20 May 2003
Resolved
Repair as new, port life float puncture damage from birds.
Lifesaving › Buoyant Apparatus
Issued 20 May 2003
Resolved
Label lifefloat paddles "TAHOE PARADISE".
Electrical › Electric Supply System (service)
Issued 20 May 2003
Resolved
Isolate improperly installed 12 volt grounding system from vessel hull. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (service)
Issued 20 May 2003
Resolved
Remove wire nut from engine room bilge pump wiring and properly wire in accordance with 46 CFR 183.349 (i)(2). LEGACY COMPONENT DESC: Wiring
Fire Fighting › Fire Pumps
Issued 7 June 2002
Resolved
Submit plans to provide two sources of power for fire pump IAW G-MOC ltr dated 24APR02 to MSO San Francisco Bay for approval. LEGACY COMPONENT DESC: Power Source
Navigation
Issued 26 July 2000
Resolved
REPAIR/REPLACE PACKING ON PORT AND STBD RUDDER LOG TO STOP LEAKING.
Accommodation/Occupational Safety
Issued 10 July 1998
Resolved
PROVIDE A LOCKING DEVICE FOR VESSEL'S KENMORE OVEN DOOR AND SEA RAILS FOR THE RANGE TOP IN ACCORDANCE WITH 46 CFR 184.220. THE KENMORE OVEN/RANGE ISNOT TO BE USED WITH PASSENGERS ABOARD UNTIL THIS REQUIREMENT HAS BEEN CLEARED BY AN ATTENDING MARINE INSPECTOR.
Lifesaving
Issued 10 July 1998
Resolved
PROVIDE A PERMANENT MEANS FOR THE VESSEL'S CREW TO READILY ACCESS THE LIFEFLOATS IN ACCORDANCE WITH 46 CFR 180.130(3).
Documentation
Issued 10 July 1998
Resolved
PROVIDE COPIES OF APPROVED PLANS & ADDRESS ANY COMMENTS FOR THE FOLLOWING SYSTEMS: PROPULSION (INCLUDING PROPULSION CONTROLS AND SHAFT DETAILS), STEERING AND STEERING CONTROLS (INCLUDING RUDDERS), VENTILATION, FIRE PROTECTION EQUIPMENT, AND PIPING SYSTEMS IN ACCORDANCE WITH 46 CFR 177.202
Engineering
Issued 10 July 1998
Resolved
PROVIDE PROPER VENTILATION FOR VESSEL'S ENGINE ROOM IN ACCORDANCE WITH 46 CFR 182.465
Construction/Loadline
Issued 10 July 1998
Resolved
PROVIDE VENTILATION FOR THE SPACE CONTAINING VESSEL'S DIESEL FUEL TANKS IN ACCORDANCE WITH 46 CFR 182.470
Unknown
Issued 10 July 1998
Resolved
PROVIDE A SECOND SOURCE OF POWER FOR THE VESSEL'S PUBLIC ADDRESS SYSTEM IN ACCORDANCE WITH 46 CFR 183.310(A)(1)(iii).
Fire Fighting
Issued 10 July 1998
Resolved
REPLACE THE VESSEL'S FIXED FIRE EXTINGUISHING SYSTEM CYLINDER WITH AN APPROVED FIXED FIRE EXTINGUISHING SYSTEM CYLINDER THAT IS SIZED PROPERLY TOPROTECT THE VESSEL'S ENGINE ROOM.
Fire Fighting
Issued 10 July 1998
Resolved
UNTIL SUCH TIME THAT REQUIREMENT 008 HAS BEEN COMPLETED, THE VESSEL MUST PROVIDE A B-IV OR B-V TYPE CO2 FIRE EXTINGUISHER TO BE LOCATED NEAR THE OPENING TO THE ENGINE ROOM. THE VESSEL IS PROHIBITED FROM CARRYING PASSENGERS UNTIL THE EXTINGUISHER HAS BEEN PLACED ABOARD THE VESSEL.
Construction/Loadline
Issued 10 July 1998
Resolved
PROVIDE DRAFT MARKS OR LOADING MARKS IN ACCORDANCE WITH 46 CFR 185.602
Electrical
Issued 10 July 1998
Resolved
PROVIDE AN APPROVED COPY OF REVISED ELECTRICAL DRAWINGS REFLECTING THE VESSEL'S AS BUILT CONFIGURATION.
Casualty record · 1
19 December 2015Routine · role: Involved in a Marine Casualty · activity 5824301
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.