TAHOE PARADISE

Built
1998
Last inspected
13 May 2025
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 May 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY8027
477989
Flag
UNITED STATES
Maury page id
psix-477989

Documentation record

Registered dimensions (L × B × D)72.5 ft × 18.0 ft × 5.3 ft
Registered tonnagegross 98 / net 89
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTSS FAB INC/SKIPPERLINER · LACROSSE, WI, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSOUTH LAKE TAHOE, CA
Endorsements, as the file codes themcw_un, rec, reg
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Simplified, Gross Ton
89 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 45 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

13 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8118779
15 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7920740
29 August 2023 Drydock Exam · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7775991
18 May 2023 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7685938
13 April 2023 Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7673029
4 May 2022 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7436223
26 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7182761
13 July 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7005457
10 May 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681505
24 May 2018 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6428206
21 May 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6417052
3 May 2017 Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138357
2 May 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6036632

Deficiency record · 45

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2025 Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Strainers must be the type of opening on top for cleaning screens. A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Flame screen on the generator fuel filter is missing. 46 CFR 182.455(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 28 May 2025
Resolution: Operator installed steel flame screen.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 May 2025 Resolved
A hatch cover must: (1) Have securing devices; and (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Engine room hatch cover does not have captive device. 46 CFR 179.360(b)(2)
Action required: 10 - Deficiency Rectified
Resolved 13 May 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2025 Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. The stability letter was not onboard the vessel. 46 CFR 176.306
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2025 Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. The light lanyards are frayed and not long enough. 46 CFR 180.175(f)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2025 Resolved
If the vessel carries more than one life float or buoyant apparatus in a group with each group secured by a single painter:(3) Each life float and buoyant apparatus must be individually attached to the painter by a line meeting § 180.175(f)(3) (ii), (iii), and (iv) and long enough that each life float or buoyant apparatus can float without contacting any other life float or buoyant apparatus in the group. MI identified only 2 of the 4 lifefloat painter lines were connected to the weak link. 46 CFR 180.137(e)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 15 May 2024 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Vessel’s life floats were found ripped due to bird activity. Vessel must repair the life floats to the satisfaction of the Marine Inspector. 46CF185.604(i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 27 August 2024
Resolution: Recieved evidence of repair, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2024 Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. The life buoy on the bow was found degraded. Replace the life buoy to the satisfaction of the Marine Inspector. 46CFR180.70(a)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Photo was submitted to clear def, found sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2024 Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Vessel was found with sagging and worn insulation in the engine room. Repair the insulation to the satisfaction of the Marine Inspector. 46CFR177.405(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 8 July 2024
Resolution: Verified insulation reinstalled during def check.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 May 2024 Resolved
A hatch exposed to the weather must be watertight. Hatches leading into the engine room that are exposed to the weather were found not watertight. Repair the hatches leading to the engine room to be able to meet the requirements of being watertight to the satisfaction of the Marine Inspector. 46CFR179.3609(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 27 August 2024
Resolution: Recieved photo of installed gasket.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 May 2024 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Vessel’s Fuel Oil space has 3 penetrations in the watertight bulkheads that are not properly sealed, and are now not watertight. Seal the penetrations in the fuel oil space to the satisfaction of the Marine Inspector. 46CFR179.320(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 8 July 2024
Resolution: Verified proper installation and sealing during def check.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 15 May 2024 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Vessel was missing the required maximum passengers signage as required on their top deck. Install the proper signage to the satisfaction of the Marine Inspector. 46CFR185.602(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Photo submitted to clear def, found all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2024 Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel was found with a plastic trashcan in the main deck galley space. Remove the plastic trashcan to the satisfaction of the Marine Inspector. 46CFR177.405(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Pastic trashcan has been removed and replaced with a metallic one, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 May 2024 Resolved
Equipment specifications for life floats and buoyant apparatus. The equipment required for life floats and buoyant apparatus must meet the following specifications:(2) Paddle. Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Starboard aft life float has one paddle that is not lashed. Properly lash the paddle to the satisfaction of the Marine Inspector. 46CFR180.175(f)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Photo sent clearing def, found all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2024 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Vessels life buoys were found without retroreflective tape. Install retroreflective tape to the satisfaction of the Marine Inspector. 46CF185.604(i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Photo submitted to clear def, found all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 May 2024 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. All paddles were found without proper vessel name markings. Mark all paddles with the vessel’s name to the satisfaction of the Marine Inspector. 46CFR185.604(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Photo submitted to clear def, found all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 May 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel was found with a broken first aid kit. Replace the first aid kit to the satisfaction of the Marine Inspector. 46CFR184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Vessel purchased new med kit, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 18 May 2023 Resolved
All griddles, broilers and deep fat fryers must be witted with a grease extraction hood in compliance 46 CFR 181.425. The Griddle in the galley is missing a grease extraction hood and must be removed or tagged out. 46 CFR 181.405(b)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Deficiency rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2023 Resolved
Electrical equipments used in the following location must be dripproof: location exposed to wet conditions. The vessel's void space below the the galley had an electrical switch that is not dripproof. 46 CFR 183.210(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2023
Resolution: Verified deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2023 Resolved
The installation of portable fire extinguisher must be to the satisfaction of the OCMI. The vessel's two portable fire extinguishers were not mounted to a frame. 46 CFR 181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2023
Resolution: Verified in person.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 18 May 2023 Resolved
Vessel is inspected for compliance with standards required by this subchapter. Equipments not covered by this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessel's ladder to the lifefloat shall be permanently secured. 46 CFR 176.800(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2023
Resolution: Verified in person.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 May 2023 Resolved
Each item of survival craft equipment must be of a good quality and efficient for the purpose it's intended to serve. The vessel's lifefloat paddles were missing the vessel's name. 46 CFR 180.175(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2023
Resolution: Verified deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 May 2023 Resolved
At each subsequent inspection for certification shall be prepared to test navigational lights. Vessel's stern light was inoperable. Vessel limited to daytime operations. 46 CFR 176.816
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 May 2023
Resolution: Verified in person.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 May 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems.Lifefloats on board are no longer in serviceable condition. Vessel is limited to 1NM from shore until replacement is made.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2022
Resolved 20 May 2022
Resolution: Vessel has shown proof of replacements purchased. Vessel is limited to 1NM until lifefloats are on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including testing of each firehose to a test pressure equivalent to its maximum service pressure. Firehose on aft main deck sustained multiple punctures and is no longer serviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 20 May 2022
Resolution: Replaced with new fire hose.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2021 Resolved
Survival craft equipment. The floating waterlight must be attached around the body of the life float or buoyant apparatus. Re-rig waterlight line. 46 CFR 180.75 (f) (4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent pictures of properly rigged waterlight line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2021 Resolved
Survival craft equipment. Each life float must fitted with two paddles. Replace missing paddles (8) 46 CFR 180.75 (d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent pictures of acquired paddles.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 April 2021 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Repair damaged life floats on starboard side. 46 CFR 180.75 (a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent picture of repaired life floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 July 2020 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Discovered no bilge strainer present in the #2 compartment. 46 CFR 182.510 (b)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 16 August 2020
Resolved 13 August 2020
Resolution: Operator sent picture of newly installed bilge strainer
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 July 2020 Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Vessel listed rescue boats in emergency instructions when not one is utilized onboard.46 CFR 185.510(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 17 July 2020
Resolution: Operator updated emergency instructions.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 July 2020 Resolved
At each vessel inspection all observed unsafe practices must be corrected. Unsecured oxygen bottle discovered in the pilot house. 46 CFR 176.830(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 13 August 2020
Resolution: Operator sent pictures of secured oxygen bottle.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 July 2020 Resolved
There shall be aspirin, ammonia inhalant, iodine applicators, and eye wash in the first-aid kit. Expired aspirin, ammonia inhalants, iodine, and eyewash in first-aid kit. 46 CFR 184.710 & 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 17 July 2020
Resolution: Operator provided new medicine.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 13 July 2020 Resolved
Man overboard drills shall be logged for review by the Coast Guard upon request. The drill entry shall include date of the drill and training and general description of the drill scenario and training topics. No documented MOB drills onboard. 46 CFR 185.520(f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 13 August 2020
Resolution: Received pictures from operator with completed MOB drill log.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 July 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. No updated charts onboard. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 17 July 2020
Resolution: Operator downloaded charts onto phone.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 July 2020 Resolved
As appropriate for the intended voyage, a vessel must carry an adequate and up-to-date Coast Guard Light List. No updated light list onboard. 46 CFR121.420(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2020
Resolved 16 July 2020
Resolution: Operator printed out updated light list.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 July 2020 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Worn labeling identified on ring buoy. 46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 13 August 2020
Resolution: Received picture from operator of updated life ring buoy name labeling.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019 Resolved
Each distribution terminal part of a conductor must be made within an enclosure. A hot lead (indication by "Circuit Alert GB" non contact voltage detector) was found about 4" above the main power panel while vessel was plugged into shore power (panel interlock sat, in shore power position).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2019
Resolved 17 May 2019
Resolution: Unused cable was removed, presented to USCG inspector attending adjacent vessel 17 MAY.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary to safety under normal and emergency conditions, and progect passengers, crew, other persons and the vessel from electrical hazards. Portable water sump pump was found used as galley grey water transfer and storage pump using extension cords.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 23 July 2019
Resolution: Photo received via email, bilge galley sumps wiring made permanent.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary to safety under normal and emergency conditions. Several "y" and butt splices were found in 110V AC electric wire and several unused runs of 110V AC electric wire found in vicinity of galley service space entry ladder.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 22 July 2019
Resolution: Photo submitted with y splices and unused wiring removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019 Resolved
Protection from wet and corrosive environments. Electrical equipment on a vessel must be installed and maintained to provide services necessary to safety under normal and emergency conditions. 12 V sensor connection at fuel tank (fuel tank space) and two 12 V connections - one open and unused, one with twist locks at 12V bilge pump near bilge level (centerline galley services space).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 22 July 2019
Resolution: Photos submitted for Fuel tank space and galley services space sensor connections permanent terminated above bilge and unused wires removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2019 Resolved
Lifesaving equipment markings. The number and identification of the items stowed inside, and their sizes, must be marked clearly in legible letters and numbers on each container for life jackets. Letters and numbers must be two inches high, symbols four inches square. PFD storage was not marked, and is inside of open deck furniture.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 22 July 2019
Resolution: Photos submitted of Enclosed lounge chairs marked with PFDs contained.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2019 Resolved
Stowage of lifejackets. Each child life jackeet must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Childrens PFD's were stored in open deck furniture, not marked and mixed with adult PFD's.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 22 July 2019
Resolution: Photo submitted of childrens' PFDs stowed in common collection and marked as childrens' PFDs.
Lifesaving › Lifefloat › Float-free Link
Issued 24 May 2018 Resolved
Procure new life-float weak link with proper documentation.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2018
Resolved 31 July 2018
Resolution: Documentation provided for installation of the new weak link.
Stability › Watertight Integrity › General
Issued 24 May 2018 Resolved
Make hatches to the laz/engine room watertight & secure with chain.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2018
Resolved 31 July 2018
Resolution: Vessel provided proof that the hatches are properly latched/watertight.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 May 2017 Resolved
Vessel missing 7 of required 14 child life jackets. Vessel restricted to carrying 7 child passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 30 May 2017
Resolution: Received documentation from vessel rep for replacement of missing child pfds.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 May 2017 Resolved
Light not attached to life buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 10 May 2017
Resolution: Vessel affixed light to ring buoy.

Ownership record