TAHOE PARADISE

TAHOE PARADISE is a 1998 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1998, most recently in May 2025, along with 129 deficiencies, 3 operational controls and 1 casualty investigation in 2015.

Records from 1998 to 2025. Most recent: operational control imposed, 13 May 2025.

Built
1998
Last inspected
13 May 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY8027
477989
Flag
UNITED STATES
—
Maury page id
psix-477989

Inspections, by type

…with no type recorded4
Years with a record 26 calendar years (1998–2025)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)72.5 ft × 18.0 ft × 5.3 ft
Registered tonnagegross 98 / net 89
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTSS FAB INC/SKIPPERLINER · LACROSSE, WI, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSOUTH LAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Simplified, Gross Ton
89 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY8027MMSI not assigned · expired · compulsorily equipped · granted 17 December 1998, cancelled 21 February 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 46

13 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8118779
15 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7920740
29 August 2023 Drydock Exam · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7775991
18 May 2023 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7685938
13 April 2023 Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7673029
4 May 2022 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7436223
26 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7182761
13 July 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7005457
10 May 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681505
24 May 2018 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6428206
21 May 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6417052
3 May 2017 Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138357
2 May 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6036632
19 December 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5784701
19 December 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5824301
18 December 2015 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5784826
17 July 2015 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5183992
10 June 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4877740
18 July 2012 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4391687
12 June 2012 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4342289
22 July 2011 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4097631
4 May 2009 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3495070
14 April 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3450058
10 June 2008 Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3224913
15 May 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3202109
9 April 2008 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3177109
30 May 2007 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2952216
30 May 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2981171
24 April 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2629570
28 March 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2611555
3 May 2005 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2355180
13 August 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2165473
11 May 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2064796
20 May 2003 Hull Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779768
30 April 2003 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1783739
7 June 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1624199
16 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075579
9 July 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384821
26 July 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1365900
6 July 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 820338
13 March 2000 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1047603
26 July 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1391069
10 December 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 811280
10 July 1998 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1112174
10 July 1998 Initial Certification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1378750
24 June 1998 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1470462

Deficiency record · 129

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2025 Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Strainers must be the type of opening on top for cleaning screens. A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Flame screen on the generator fuel filter is missing. 46 CFR 182.455(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 28 May 2025
Resolution: Operator installed steel flame screen.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 May 2025 Resolved
A hatch cover must: (1) Have securing devices; and (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Engine room hatch cover does not have captive device. 46 CFR 179.360(b)(2)
Action required: 10 - Deficiency Rectified
Resolved 13 May 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2025 Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. The stability letter was not onboard the vessel. 46 CFR 176.306
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2025 Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. The light lanyards are frayed and not long enough. 46 CFR 180.175(f)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2025 Resolved
If the vessel carries more than one life float or buoyant apparatus in a group with each group secured by a single painter:(3) Each life float and buoyant apparatus must be individually attached to the painter by a line meeting § 180.175(f)(3) (ii), (iii), and (iv) and long enough that each life float or buoyant apparatus can float without contacting any other life float or buoyant apparatus in the group. MI identified only 2 of the 4 lifefloat painter lines were connected to the weak link. 46 CFR 180.137(e)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 15 May 2024 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Vessel’s life floats were found ripped due to bird activity. Vessel must repair the life floats to the satisfaction of the Marine Inspector. 46CF185.604(i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 27 August 2024
Resolution: Recieved evidence of repair, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2024 Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. The life buoy on the bow was found degraded. Replace the life buoy to the satisfaction of the Marine Inspector. 46CFR180.70(a)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Photo was submitted to clear def, found sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2024 Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Vessel was found with sagging and worn insulation in the engine room. Repair the insulation to the satisfaction of the Marine Inspector. 46CFR177.405(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 8 July 2024
Resolution: Verified insulation reinstalled during def check.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 May 2024 Resolved
A hatch exposed to the weather must be watertight. Hatches leading into the engine room that are exposed to the weather were found not watertight. Repair the hatches leading to the engine room to be able to meet the requirements of being watertight to the satisfaction of the Marine Inspector. 46CFR179.3609(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 27 August 2024
Resolution: Recieved photo of installed gasket.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 May 2024 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Vessel’s Fuel Oil space has 3 penetrations in the watertight bulkheads that are not properly sealed, and are now not watertight. Seal the penetrations in the fuel oil space to the satisfaction of the Marine Inspector. 46CFR179.320(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 8 July 2024
Resolution: Verified proper installation and sealing during def check.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 15 May 2024 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Vessel was missing the required maximum passengers signage as required on their top deck. Install the proper signage to the satisfaction of the Marine Inspector. 46CFR185.602(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Photo submitted to clear def, found all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2024 Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel was found with a plastic trashcan in the main deck galley space. Remove the plastic trashcan to the satisfaction of the Marine Inspector. 46CFR177.405(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Pastic trashcan has been removed and replaced with a metallic one, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 May 2024 Resolved
Equipment specifications for life floats and buoyant apparatus. The equipment required for life floats and buoyant apparatus must meet the following specifications:(2) Paddle. Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Starboard aft life float has one paddle that is not lashed. Properly lash the paddle to the satisfaction of the Marine Inspector. 46CFR180.175(f)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Photo sent clearing def, found all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2024 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Vessels life buoys were found without retroreflective tape. Install retroreflective tape to the satisfaction of the Marine Inspector. 46CF185.604(i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Photo submitted to clear def, found all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 May 2024 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. All paddles were found without proper vessel name markings. Mark all paddles with the vessel’s name to the satisfaction of the Marine Inspector. 46CFR185.604(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Photo submitted to clear def, found all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 May 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel was found with a broken first aid kit. Replace the first aid kit to the satisfaction of the Marine Inspector. 46CFR184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 6 June 2024
Resolution: Vessel purchased new med kit, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 18 May 2023 Resolved
All griddles, broilers and deep fat fryers must be witted with a grease extraction hood in compliance 46 CFR 181.425. The Griddle in the galley is missing a grease extraction hood and must be removed or tagged out. 46 CFR 181.405(b)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Deficiency rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2023 Resolved
Electrical equipments used in the following location must be dripproof: location exposed to wet conditions. The vessel's void space below the the galley had an electrical switch that is not dripproof. 46 CFR 183.210(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2023
Resolution: Verified deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2023 Resolved
The installation of portable fire extinguisher must be to the satisfaction of the OCMI. The vessel's two portable fire extinguishers were not mounted to a frame. 46 CFR 181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2023
Resolution: Verified in person.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 18 May 2023 Resolved
Vessel is inspected for compliance with standards required by this subchapter. Equipments not covered by this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessel's ladder to the lifefloat shall be permanently secured. 46 CFR 176.800(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2023
Resolution: Verified in person.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 May 2023 Resolved
Each item of survival craft equipment must be of a good quality and efficient for the purpose it's intended to serve. The vessel's lifefloat paddles were missing the vessel's name. 46 CFR 180.175(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2023
Resolution: Verified deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 May 2023 Resolved
At each subsequent inspection for certification shall be prepared to test navigational lights. Vessel's stern light was inoperable. Vessel limited to daytime operations. 46 CFR 176.816
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 May 2023
Resolution: Verified in person.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 May 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems.Lifefloats on board are no longer in serviceable condition. Vessel is limited to 1NM from shore until replacement is made.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2022
Resolved 20 May 2022
Resolution: Vessel has shown proof of replacements purchased. Vessel is limited to 1NM until lifefloats are on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including testing of each firehose to a test pressure equivalent to its maximum service pressure. Firehose on aft main deck sustained multiple punctures and is no longer serviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 20 May 2022
Resolution: Replaced with new fire hose.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2021 Resolved
Survival craft equipment. The floating waterlight must be attached around the body of the life float or buoyant apparatus. Re-rig waterlight line. 46 CFR 180.75 (f) (4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent pictures of properly rigged waterlight line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2021 Resolved
Survival craft equipment. Each life float must fitted with two paddles. Replace missing paddles (8) 46 CFR 180.75 (d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent pictures of acquired paddles.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 April 2021 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Repair damaged life floats on starboard side. 46 CFR 180.75 (a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 26 May 2021
Resolution: Operator sent picture of repaired life floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 July 2020 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Discovered no bilge strainer present in the #2 compartment. 46 CFR 182.510 (b)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 16 August 2020
Resolved 13 August 2020
Resolution: Operator sent picture of newly installed bilge strainer
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 July 2020 Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Vessel listed rescue boats in emergency instructions when not one is utilized onboard.46 CFR 185.510(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 17 July 2020
Resolution: Operator updated emergency instructions.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 July 2020 Resolved
At each vessel inspection all observed unsafe practices must be corrected. Unsecured oxygen bottle discovered in the pilot house. 46 CFR 176.830(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 13 August 2020
Resolution: Operator sent pictures of secured oxygen bottle.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 July 2020 Resolved
There shall be aspirin, ammonia inhalant, iodine applicators, and eye wash in the first-aid kit. Expired aspirin, ammonia inhalants, iodine, and eyewash in first-aid kit. 46 CFR 184.710 & 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 17 July 2020
Resolution: Operator provided new medicine.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 13 July 2020 Resolved
Man overboard drills shall be logged for review by the Coast Guard upon request. The drill entry shall include date of the drill and training and general description of the drill scenario and training topics. No documented MOB drills onboard. 46 CFR 185.520(f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 13 August 2020
Resolution: Received pictures from operator with completed MOB drill log.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 July 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. No updated charts onboard. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 17 July 2020
Resolution: Operator downloaded charts onto phone.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 July 2020 Resolved
As appropriate for the intended voyage, a vessel must carry an adequate and up-to-date Coast Guard Light List. No updated light list onboard. 46 CFR121.420(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2020
Resolved 16 July 2020
Resolution: Operator printed out updated light list.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 July 2020 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Worn labeling identified on ring buoy. 46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 13 August 2020
Resolution: Received picture from operator of updated life ring buoy name labeling.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019 Resolved
Each distribution terminal part of a conductor must be made within an enclosure. A hot lead (indication by "Circuit Alert GB" non contact voltage detector) was found about 4" above the main power panel while vessel was plugged into shore power (panel interlock sat, in shore power position).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2019
Resolved 17 May 2019
Resolution: Unused cable was removed, presented to USCG inspector attending adjacent vessel 17 MAY.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary to safety under normal and emergency conditions, and progect passengers, crew, other persons and the vessel from electrical hazards. Portable water sump pump was found used as galley grey water transfer and storage pump using extension cords.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 23 July 2019
Resolution: Photo received via email, bilge galley sumps wiring made permanent.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary to safety under normal and emergency conditions. Several "y" and butt splices were found in 110V AC electric wire and several unused runs of 110V AC electric wire found in vicinity of galley service space entry ladder.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 22 July 2019
Resolution: Photo submitted with y splices and unused wiring removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019 Resolved
Protection from wet and corrosive environments. Electrical equipment on a vessel must be installed and maintained to provide services necessary to safety under normal and emergency conditions. 12 V sensor connection at fuel tank (fuel tank space) and two 12 V connections - one open and unused, one with twist locks at 12V bilge pump near bilge level (centerline galley services space).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 22 July 2019
Resolution: Photos submitted for Fuel tank space and galley services space sensor connections permanent terminated above bilge and unused wires removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2019 Resolved
Lifesaving equipment markings. The number and identification of the items stowed inside, and their sizes, must be marked clearly in legible letters and numbers on each container for life jackets. Letters and numbers must be two inches high, symbols four inches square. PFD storage was not marked, and is inside of open deck furniture.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 22 July 2019
Resolution: Photos submitted of Enclosed lounge chairs marked with PFDs contained.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2019 Resolved
Stowage of lifejackets. Each child life jackeet must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Childrens PFD's were stored in open deck furniture, not marked and mixed with adult PFD's.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 22 July 2019
Resolution: Photo submitted of childrens' PFDs stowed in common collection and marked as childrens' PFDs.
Lifesaving › Lifefloat › Float-free Link
Issued 24 May 2018 Resolved
Procure new life-float weak link with proper documentation.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2018
Resolved 31 July 2018
Resolution: Documentation provided for installation of the new weak link.
Stability › Watertight Integrity › General
Issued 24 May 2018 Resolved
Make hatches to the laz/engine room watertight & secure with chain.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2018
Resolved 31 July 2018
Resolution: Vessel provided proof that the hatches are properly latched/watertight.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 May 2017 Resolved
Vessel missing 7 of required 14 child life jackets. Vessel restricted to carrying 7 child passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 30 May 2017
Resolution: Received documentation from vessel rep for replacement of missing child pfds.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 May 2017 Resolved
Light not attached to life buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 10 May 2017
Resolution: Vessel affixed light to ring buoy.
Electrical › Electric Generation Source (service) › Generator
Issued 18 December 2015 Resolved
During operation the alternator bearing seized, the attached belt heated and started a fire. Prove proper operation of ship service generator after repoer/new install.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 17 July 2015 Resolved
In the bar hold the sewage pump is loosely mounted and wiring under strain and not properly supported. Properly mount pump base, install longer conductor to eliminat strain and properly support wiring.
Action required: 705 - Other - as specified
Due 17 July 2015
Resolved 2 May 2016
Electrical › Electrical Distribution System (service) › Conductor
Issued 17 July 2015 Resolved
Wiring for AC pump power box located in bar hold does not have strain relief at service entrance to box. Install strain relief and properly support wiring that is hanging loosely.
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 2 May 2016
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 17 July 2015 Resolved
The wiring conduit running from electrical distribution center through main deck into engine compartment above port generator is missing fire seal in transit block. Install proper fire seal to transit block.
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 2 May 2016
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 July 2015 Resolved
! life float water light found not to work. All 4 float lights for life floats need new attaching lines. Make float light operational (install new battery) and install new lanyards to all 4 float lights.
Action required: 705 - Other - as specified
Due 17 July 2015
Resolved 17 July 2015
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 July 2015 Resolved
The coffee maker in galley is mounted in a manner that pinches the cord and strains socket. Move coffee maker to eliminate kink in cord and allow plug to be strain free.
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 2 May 2016
Documentation › Certificates/Documents › Stability Letter
Issued 17 July 2015 Resolved
The vessel stability letter is mounted under glass in passenger accommodation area on main deck below pilot house. Re-locate stability letter to suitable place in pilot house where it is available to operator.
Action required: 705 - Other - as specified
Due 17 July 2015
Resolved 17 July 2015
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 June 2014 Resolved
Install a corrosion resistant clip for water light.
Due 20 June 2014
Resolved 10 June 2014
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 June 2014 Resolved
Install fastner for stbd MDE s/w strainer cap.
Due 20 June 2014
Resolved 27 June 2014
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 10 June 2014 Resolved
Replace 4 buoyant apparatus water light batteries. Restricted to day time operations.
Due 20 June 2014
Resolved 13 June 2014
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 June 2014 Resolved
Install new light bulb for aft main deck e-lighting
Due 20 June 2014
Resolved 27 June 2014
Deck/Cargo › Holds/Tanks › Hatch
Issued 10 June 2014 Resolved
Install new gasket for forpeak hatch.
Due 20 June 2014
Resolved 20 June 2014
Electrical › Electrical Distribution System (service) › Cable
Issued 13 June 2012 Resolved
Install metallic supports spaced not more than 24 inches apart on all electrical cabling.
Condition: Improper Installation
Due 13 July 2012
Resolved 8 October 2012
Resolution: metallic supports were provided.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 13 June 2012 Resolved
Prove proper operation of main distribution panel shoretie/ gen interlock.
Condition: Design Flaw
Due 13 July 2012
Resolved 18 July 2012
Resolution: Vessel representative installed and demonstrated proper operation of the main distribution shoretie/gen interlock
Engineering › Steering Gear System › Rudder
Issued 13 June 2012 Resolved
Provide repair proposal for damaged port rudder.
Condition: Damaged By Earlier Event
Due 20 June 2012
Resolved 24 June 2012
Resolution: Repair proposal provided by vessel representative.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 13 June 2012 Resolved
Prove proper operation of port shaft seal.
Condition: Improper/Lack of Maintenance
Due 13 July 2012
Resolved 18 July 2012
Resolution: Vessel represeantative installed and adjusted new packing on port shaft seal
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 13 June 2012 Resolved
Provide two additional adult lifejackets as required by COI.
Condition: Improper Installation
Due 20 June 2012
Resolved 13 June 2012
Resolution: Provided two additional onboard.
Lifesaving › Lifefloat › Paddle
Issued 13 June 2012 Resolved
Replace four sun damaged paddles on bouyant apparatus.
Condition: Improper/Lack of Maintenance
Due 13 July 2012
Resolved 18 July 2012
Resolution: Vessel representative provided four new paddles for buoyant app.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 13 June 2012 Resolved
Replace expired batteries on 2 waterlights on bouyant apparatus.
Condition: Improper/Lack of Maintenance
Due 13 July 2012
Resolved 18 July 2012
Resolution: Water light batteries were replaced by vessel representative
Construction/Loadline › Penetrations › Valve Flange
Issued 13 June 2012 Resolved
Prove watertight integrity of starboard main engine raw water intake through hull valve.
Condition: Improper/Lack of Maintenance
Due 13 July 2012
Resolved 8 October 2012
Resolution: provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 June 2012 Resolved
Prove proper operation of anchor light.
Condition: Improper/Lack of Maintenance
Due 13 July 2012
Resolved 18 July 2012
Resolution: Vessel representative proved proper operationof anchor light
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 June 2012 Resolved
Provide asprin, eye wash, and ammonia inhallents in first aid kit.
Condition: Placed in Improper Service
Due 13 July 2012
Resolved 18 July 2012
Resolution: Vessel representative provided missing items in first aid kit
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 13 June 2012 Resolved
Prove proper operation of engine room ventilation closures.
Condition: Improper/Lack of Maintenance
Due 13 July 2012
Resolved 8 October 2012
Resolution: Provided.
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011 Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 21 August 2011
Resolved 19 August 2011
Resolution: DER emailed MIS report and Consortium letter
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011 Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Due 21 August 2011
Resolved 22 July 2011
Resolution: Training conducted, fixed on the spot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2009 Resolved
Properly wire A/C pump in Void # 4.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 4 May 2009
Resolution: Corrected.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 14 April 2009 Resolved
Properly secure A/C unit in void #4.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 4 May 2009
Resolution: Properly mounted unit.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 April 2009 Resolved
Replace stern light bulb with proper bulb.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 4 May 2009
Resolution: Proper bulb installed.
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 May 2008 Resolved
Vessel is restricted from carrying passengers as of 09 June 2008.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2008
Construction/Loadline › Hull › Hull Plating
Issued 15 May 2008 Resolved
Vessel will be made ready for inspection on 10 June 2008.
Action required: 705 - Other - as specified
Resolved 10 June 2008
Construction/Loadline › Hull › Hull Plating
Issued 15 May 2008 Resolved
USCG marine inspectors will conduct an out of the water hull exam on 10 June 2008.
Action required: 705 - Other - as specified
Resolved 10 June 2008
Construction/Loadline › Hull › Hull Plating
Issued 15 May 2008 Resolved
Submit scope of work to the attending marine inspector after the vessel has been hauled out of the water.
Action required: 705 - Other - as specified
Resolved 10 June 2008
Lifesaving › Lifefloat › Serviceable
Issued 9 April 2008 Resolved
Renew or repair life floats.
Due 10 May 2008
Resolved 15 May 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 9 April 2008 Resolved
Properly dead-end or connect wires in way of underneath console at operating station.
Due 10 May 2008
Resolved 15 May 2008
Lifesaving › Hand Flares › Storage
Issued 9 April 2008 Resolved
Provide approved storage for flares.
Due 10 May 2008
Resolved 10 April 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 April 2008 Resolved
Properly install and test fixed firefighting engine shut down to SSD generator. Vessel is restricted from operating generator with passengers on board.
Due 10 May 2008
Resolved 15 May 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 April 2008 Resolved
Provide current COD prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 April 2008 Resolved
Properly install life line to life ring.
Due 10 May 2008
Resolved 10 April 2008
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 9 April 2008 Resolved
Properly install port side engine room vent closure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 17 March 2008 Resolved
Background history checks not being completed in accordance with 49 CFR 40.25.
Due 17 March 2008
Resolved 15 May 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007 Resolved
Company policy missing as required by 46 CFR part 16.401.
Due 29 June 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007 Resolved
MRO drug free determination before returning to work regulations not being followed as required in 49 CFR part 40; crewmember returned to work with only a letter from a SAP. Letter from MRO must be provided.
Due 29 June 2007
Resolved 17 March 2008
Resolution: Employee referred to in original deficiency failed last return-to-work drug test and was fired. Company will comply with regulations in the future.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007 Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Due 29 June 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007 Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401.
Due 29 June 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007 Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Due 29 June 2007
Resolved 10 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 27 June 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 30 May 2007 Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 29 June 2007
Resolved 17 March 2008
Lifesaving › Lifefloat › Markings
Issued 30 May 2007 Resolved
Label stbd forward lifefloat paddle.
Due 30 June 2007
Resolved 30 May 2007
Lifesaving › Hand Flares › Expired
Issued 3 May 2005 Resolved
Renew 3 orange and 3 red hand flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 July 2005
Resolved 3 May 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 May 2005 Resolved
Install a waterlight with lanyard to the 22 passenger life float.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 July 2005
Resolved 6 May 2005
Lifesaving › Lifefloat › Paddle
Issued 3 May 2005 Resolved
Renew all the paddles for the 4 life floats. Properly label the vessel's name on each paddle and secure it to each life float.
Due 3 July 2005
Resolved 6 May 2005
Lifesaving › Lifefloat › Markings
Issued 3 May 2005 Resolved
Label the max passenger capacity for each life float.
Due 3 July 2005
Resolved 6 May 2005
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 3 May 2005 Resolved
Post a life jacket donning placard on each deck.
Due 3 July 2005
Resolved 6 May 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 May 2005 Resolved
Properly separate children and adult PFDs.
Due 3 July 2005
Resolved 3 May 2005
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 3 May 2005 Resolved
Properly store 8 adult PFDs.
Due 3 July 2005
Resolved 6 May 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 3 May 2005 Resolved
Tighten the port packing.
Due 3 July 2005
Resolved 6 May 2005
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 3 May 2005 Resolved
Post the emergency broadcast placard.
Due 3 July 2005
Resolved 6 May 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 May 2005 Resolved
Prove proper operation of the port aft life float waterlight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 July 2005
Resolved 6 May 2005
Engineering › Sea-water System (primary cooling)
Issued 18 May 2004 Resolved
Repair leak on stbd engine raw water cooling suction valve. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 18 May 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 11 May 2004 Resolved
Repair power supply wire for sewege pump located in #4 compartment under bar; properly install plug with strain relief fitting, correct insulation damage at motor.
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 24 June 2004
Accommodation/Occupational Safety › Cooking Systems
Issued 11 May 2004 Resolved
Remove from vessel spare sterno cooking cans stored in # 3 void. E-mailed a copy of CID Memo 1-03, Warming trays, to operator and required to give instruction to all personel on vessel that use this equipment. LEGACY COMPONENT DESC: Cooking Fuel
Action required: 705 - Other - as specified
Due 18 May 2004
Resolved 18 May 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 May 2004 Resolved
Operator shall provide generator operating instructions and training so that fixed fire fighting system is not placed into "OVER RIDE" condition at pilot house.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2004
Resolved 18 May 2004
Resolution: Operator has installed placard at operating station and briefed captains on operation of fixed gas fire fighting system.
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 11 May 2004 Resolved
Properly seperate child sized life preservers from adult life preservers.
Action required: 705 - Other - as specified
Due 18 May 2004
Resolved 18 May 2004
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 11 May 2004 Resolved
Properly label where passengers can easily identify the adult sized life preservers located under console area port and starboard of operating station.
Action required: 705 - Other - as specified
Due 18 May 2004
Resolved 18 May 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2004 Resolved
Update first aid kit by replacing items that have passed experation date.
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 24 June 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 20 May 2003 Resolved
Provide one additional child PFD as required by vessel's COI. Vessel is restricted from carrying more than 15 children until this requirement has been satisfied. LEGACY COMPONENT DESC: Quantity
Due 20 May 2003
Resolved 20 May 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 20 May 2003 Resolved
Provide six additional adult PFD's as required by vessel's COI. Vessel is restricted from carrying more than 143 passengers until this requirement has been satisfied. LEGACY COMPONENT DESC: Quantity
Due 20 May 2003
Resolved 20 May 2003
Lifesaving › Lifebuoys
Issued 20 May 2003 Resolved
Install corrosion resistant clip on lifering buoy water light lanyard per 46 CFR 180.70. LEGACY COMPONENT DESC: Stowage
Due 20 May 2003
Resolved 20 May 2003
Lifesaving › Buoyant Apparatus
Issued 20 May 2003 Resolved
Repair as new, port life float puncture damage from birds.
Due 23 May 2003
Resolved 22 May 2003
Lifesaving › Buoyant Apparatus
Issued 20 May 2003 Resolved
Label lifefloat paddles "TAHOE PARADISE".
Due 23 May 2003
Resolved 22 May 2003
Electrical › Electric Supply System (service)
Issued 20 May 2003 Resolved
Isolate improperly installed 12 volt grounding system from vessel hull. LEGACY COMPONENT DESC: Cable
Due 31 August 2003
Resolved 23 May 2003
Electrical › Electrical Distribution System (service)
Issued 20 May 2003 Resolved
Remove wire nut from engine room bilge pump wiring and properly wire in accordance with 46 CFR 183.349 (i)(2). LEGACY COMPONENT DESC: Wiring
Due 23 May 2003
Resolved 22 May 2003
Fire Fighting › Fire Pumps
Issued 7 June 2002 Resolved
Submit plans to provide two sources of power for fire pump IAW G-MOC ltr dated 24APR02 to MSO San Francisco Bay for approval. LEGACY COMPONENT DESC: Power Source
Action required: 705 - Other - as specified
Resolved 20 May 2003
Navigation
Issued 26 July 2000 Resolved
REPAIR/REPLACE PACKING ON PORT AND STBD RUDDER LOG TO STOP LEAKING.
Condition: Unknown
Due 26 July 2000
Resolved 26 July 2000
Accommodation/Occupational Safety
Issued 10 July 1998 Resolved
PROVIDE A LOCKING DEVICE FOR VESSEL'S KENMORE OVEN DOOR AND SEA RAILS FOR THE RANGE TOP IN ACCORDANCE WITH 46 CFR 184.220. THE KENMORE OVEN/RANGE ISNOT TO BE USED WITH PASSENGERS ABOARD UNTIL THIS REQUIREMENT HAS BEEN CLEARED BY AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 January 1999
Resolved 18 January 1999
Lifesaving
Issued 10 July 1998 Resolved
PROVIDE A PERMANENT MEANS FOR THE VESSEL'S CREW TO READILY ACCESS THE LIFEFLOATS IN ACCORDANCE WITH 46 CFR 180.130(3).
Condition: Unknown
Due 10 August 1998
Resolved 18 January 1999
Documentation
Issued 10 July 1998 Resolved
PROVIDE COPIES OF APPROVED PLANS & ADDRESS ANY COMMENTS FOR THE FOLLOWING SYSTEMS: PROPULSION (INCLUDING PROPULSION CONTROLS AND SHAFT DETAILS), STEERING AND STEERING CONTROLS (INCLUDING RUDDERS), VENTILATION, FIRE PROTECTION EQUIPMENT, AND PIPING SYSTEMS IN ACCORDANCE WITH 46 CFR 177.202
Condition: Unknown
Due 10 September 1998
Resolved 18 January 1999
Engineering
Issued 10 July 1998 Resolved
PROVIDE PROPER VENTILATION FOR VESSEL'S ENGINE ROOM IN ACCORDANCE WITH 46 CFR 182.465
Condition: Unknown
Due 10 August 1998
Resolved 18 January 1999
Construction/Loadline
Issued 10 July 1998 Resolved
PROVIDE VENTILATION FOR THE SPACE CONTAINING VESSEL'S DIESEL FUEL TANKS IN ACCORDANCE WITH 46 CFR 182.470
Condition: Unknown
Due 10 August 1998
Resolved 18 January 1999
Unknown
Issued 10 July 1998 Resolved
PROVIDE A SECOND SOURCE OF POWER FOR THE VESSEL'S PUBLIC ADDRESS SYSTEM IN ACCORDANCE WITH 46 CFR 183.310(A)(1)(iii).
Condition: Unknown
Due 10 August 1998
Resolved 18 January 1999
Fire Fighting
Issued 10 July 1998 Resolved
REPLACE THE VESSEL'S FIXED FIRE EXTINGUISHING SYSTEM CYLINDER WITH AN APPROVED FIXED FIRE EXTINGUISHING SYSTEM CYLINDER THAT IS SIZED PROPERLY TOPROTECT THE VESSEL'S ENGINE ROOM.
Condition: Unknown
Due 10 August 1998
Resolved 18 January 1999
Fire Fighting
Issued 10 July 1998 Resolved
UNTIL SUCH TIME THAT REQUIREMENT 008 HAS BEEN COMPLETED, THE VESSEL MUST PROVIDE A B-IV OR B-V TYPE CO2 FIRE EXTINGUISHER TO BE LOCATED NEAR THE OPENING TO THE ENGINE ROOM. THE VESSEL IS PROHIBITED FROM CARRYING PASSENGERS UNTIL THE EXTINGUISHER HAS BEEN PLACED ABOARD THE VESSEL.
Condition: Unknown
Due 10 August 1998
Resolved 18 January 1999
Construction/Loadline
Issued 10 July 1998 Resolved
PROVIDE DRAFT MARKS OR LOADING MARKS IN ACCORDANCE WITH 46 CFR 185.602
Condition: Unknown
Due 10 August 1998
Resolved 18 January 1999
Electrical
Issued 10 July 1998 Resolved
PROVIDE AN APPROVED COPY OF REVISED ELECTRICAL DRAWINGS REFLECTING THE VESSEL'S AS BUILT CONFIGURATION.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998

Casualty record · 1

19 December 2015Routine · role: Involved in a Marine Casualty · activity 5824301
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.