Documentation record
Registered dimensions (L × B × D)51.0 ft × 15.8 ft × 6.1 ft
Registered tonnagegross 59 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC · WESTPORT WA, UNITED STATES · built 1974
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKETCHIKAN, AK
Endorsements, as the file codes themcw_un, fi, rec, reg
DocumentationValid · issued 17 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Regulatory (Subpart C or D), Gross Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 18 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
16 April 2026
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8350786
17 April 2025
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8113075
3 April 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8104798
26 March 2025
Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8101536
29 October 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8026290
13 May 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7911606
16 May 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7691426
27 October 2022
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7587589
21 June 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7467758
30 March 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7416873
6 April 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7170336
22 March 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7160703
30 March 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6933373
9 July 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6735075
29 March 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6652248
28 March 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6387282
21 March 2017
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6108022
4 April 2016
Administrative Inspection · COE-Offshore
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5848061
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 April 2026
Resolved
The owner must provide satisfactory evidence of the required fire protection servicing to the marine inspector. Provide record of fire servicing and demonstrate fireboy shutdowns to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2026
Resolution: Operator provided recent servicing report.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 16 April 2026
Resolved
No vessel subject to inspection will be navigated unless it is under the direction and control of an individual who holds an appropriate officer endorsement on their MMC. Provide MMCs to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2026
Resolution: Operator privded satisfactory MMC.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 April 2026
Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2026
Resolution: Operator procured new fire buckets.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 16 April 2026
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum
allowed on an upper deck must be indicated in (1inch)
numbers and letter at entranceway to that deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2026
Resolution: Upper deck passenger signage was installed.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 17 April 2025
Resolved
Owner made a large hole in the collision bulkhead, as this vessel is under an Exposed criteria for stability it is necessary to keep the bulkhead watertight to limit flooding in case of a forward hull breach. Make repairs to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2023
Resolved
Ring life buoys shall be of first class workmanship and free from any defects materially affecting their appearance or serviceability. Both ring life buoy's on the upper deck were degraded with inner foam exposed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 23 May 2023
Resolution: Operator provided picture of 02 new ring life buoys.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Distribution panel in engine room had circuit breaker slot with missing blank.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 23 May 2023
Resolution: Operator provided picture of blank cover installed in circuit breaker box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2022
Resolved
The fuel system including tanks, tank vents, piping, and all fittings shall be checked and free of leaks or loose connections.
SSDG F/O supply fitting leaking IVO F/O filter.
Repair leaking fuel fittings IVO SSDG filter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2022
Resolved 4 November 2022
Resolution: Vessel operator replaced leaking F/O fitting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 October 2022
Resolved
Junction boxes, connection boxes, and outlet boxes, for use in damp or wet locations shall be of watertight construction.
The junction box in the overhead of the lazarette is missing packing gland.
Replace missing gland to make J box water tight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2022
Resolved 4 November 2022
Resolution: Vessel operator replaced packing gland on junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2022
Resolved
Electrical equipment must be installed to protect passengers and crew from electrical hazards including fire. Dead end wires found under bridge console.
Cite: 46 CFR 183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2022
Resolved 22 June 2022
Resolution: Vessel representative provided pictures attesting to proper operation and repair.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 9 July 2019
Resolved
On a fixed fire extinguishing system a device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space, upon simulated activation of fixed fire extinguishing system on line generator did not secure.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 23 July 2019
Resolution: Witnessed generator shutdown test to clear 835
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 March 2018
Resolved
Seal gap in lagging/bulkhead near fireboy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2018
Resolution: Provided photo in order to clear 835.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 March 2018
Resolved
Place labels on forward and wire run PFD Storage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2018
Resolution: Provided photo documentation to clear 835.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 March 2018
Resolved
Replace retroreflective tape on 02 liferings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2018
Resolution: Provided photo documentation to resolve 835.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 March 2018
Resolved
Provide docuemtnation to comply with drug and alcohol inspection program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2018
Resolved 8 April 2018
Resolution: Will conduct DAPI audit when other vessels are inspected May 2018.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2018
Resolved
Remove deadend wiring stbd side lazarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2018
Resolved 17 April 2018
Resolution: Received photo documentation to clear CG-835.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 March 2018
Resolved
Recrimp battery cables at lugs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2018
Resolved 17 April 2018
Resolution: Received photo documentation to clear CG-835.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 March 2018
Resolved
Label remote fuel shutoffs in aft cabin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2018
Resolution: Received photo documentation to clear CG-835.