Inspection record

Last inspected 5 May 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ8978
Flag
UNITED STATES
Maury page id
psix-47808

Documentation record

Registered dimensions (L × B × D)52.3 ft × 12.0 ft × 3.6 ft
Registered tonnagegross 44 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARRI-CRAFT INC · BERLIN, WI, UNITED STATES · built 1970
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMARINA DEL REY, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 3 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 29 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

5 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8060981
25 February 2025 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8061004
5 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7892634
5 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7672291
22 February 2023 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7620293
3 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7440918
11 March 2021 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7148858
23 February 2021 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7145154
10 June 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6968313
16 July 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6769739
9 July 2019 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6743870
1 March 2019 Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6634391
13 June 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6436373
8 January 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6333997
11 July 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6213333
12 June 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6170025
21 February 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6087543
14 March 2016 DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5800781

Deficiency record · 29

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 5 May 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 13 May 2025
Resolution: COD payment and application sent to NVDC.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 February 2025 Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. Vessel must complete proper fiber glass repairs to the starboard corner prior to the carriage of passengers and prior to credit drydock. 46 CFR 176.610 (a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2025
Resolution: satisfactory repairs verified by the attending inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 February 2025 Resolved
System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant. Vessel must complete proper repairs to the CO2 pull cable pipe in the starboard engine room prior to the carriage of passengers. 46 CFR 181.410 (a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2025
Resolution: satisfactory repairs verified by the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 June 2024 Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). The fixed power bilge pump shall be self-priming and may be driven off the main engine or other source of power. It shall be permanently connected to the bilge main and may also be connected to the fire main. If of sufficient capacity the power bilge pump may also serve as a fire pump. Primary fixed bilge pump was found inoperable and unable to de-water any compartment. Demonstrate proper operation of bilge pump for de-watering all compartments to attending Marine Inspector. OLD T: 46 CFR 182.25-10(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2024
Resolution: Bilge pump repaired and all spaces were operationally tested.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024 Resolved
Electric lighting and power cable shall not be allowed to carry a continuous current in excess of the or maximum current capacities listed in Tables 183.10-20(c)(1) and (2); minimum conductor size is 14 American Wire Gauge (AWG). In multiple areas of the vessel undersized wires/cables were found for both A/C and D/C circuits. Locations include: (Port) forward area by mini fridge, on forward bulkhead of drink storage room, midship space under deck, (STBD) midship space under deck, electrical panel room aft bulkhead and from distribution panels. All wiring powering systems over 50volts shall be atleast 14AWG and of an approved type for marine use. OLD T: 46 CFR 183.10-20(c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 21 June 2024
Resolution: All cable/wire repalced with 14AWG boat cable
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. In addition- (1) Cable must be constructed in accordance with U.S. Navy Standards, Institute of Electrical and Electronic Engineers [name withheld] 45, or be a suitable commercial grade cable, with stranded conductors, that is Underwriters Laboratories listed and rated for at least 750 C. service. Various wires and cables were found with no markings for MI to verify they are suitable for marine use; item# 2 wires. OLD T: 46 CFR 183.10-20(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 21 June 2024
Resolution: All cable/wire repalced with 14AWG boat cable/UL cable
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. In addition, Flexible or portable cords such as SO, STO, and similar types cannot be used for permanently installed wiring. Portable cords were found extending the electrical circuits throughout the vessel; locations include: drink storage room, entrance to drink storage room, under bar area, in electrical panel closet. All portable cords shall be discontinued that are being used in permanent installations to extend the circuit. OLD T:46 CFR 183.10-20(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 21 June 2024
Resolution: Portable cables removed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024 Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspection. Marine Inspector observed an unapproved A/C power receptacle with exposed face and not mounted under STBD cabinet by operating station. Alterations of vessel electrical system requires plan approval from local [name withheld] shall be removed until plans are submitted and approved. OLD T: 46 CFR 176.20-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 21 June 2024
Resolution: Receptacle mounted and face plate installed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024 Resolved
Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat. Battery box in generator space was found not mounted and the box was jammed against the outer hull resulting in wires attached to battery terminals to be excessively bent. Attach battery box to prevent shifting. OLD T: 46 CFR 183.05-20(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 21 June 2024
Resolution: Battery box properly secured
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Battery charging system for generator starting battery was found detached from bulkhead and in the bilge; reattached battery charger to bulkhead. OLD T: 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 21 June 2024
Resolution: Battery charger mounted
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024 Resolved
The conductors supplying motors and motor operated appliances shall be protected by a separate over-current device which is responsive to motor current. This device shall be rated or set at not more than 125 percent of the motor full-load current rating. No over-current protection was found on conductor attached to Port E/R battery that supplied power to port toilet system. Supply in-line fuse that is rated at no more than 125% of max amperage rating of toilet system. OLD T: 46 CFR 183.05-50(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 21 June 2024
Resolution: Over-current device installed
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 5 June 2024 Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate, or equivalent construction. Marine inspector observed the access to the machinery space was located on the interior of the vessel and not currently vapor tight. Hatches to machinery space to be fitted as to keep the vapor tight barrier. OLD T: 46 CFR 182.35-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 25 June 2024
Resolution: Gasket provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 June 2024 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Marine Inspector observed the fixed bilge pump motors at STBD bilge pump manifold and stern bilge pump manifold did not have guards. Adequate guards to be placed on both pumps rotating drives. OLD T: 46 CFR 177.35-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 21 June 2024
Resolution: Covers provided for both pumps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2024 Resolved
Fuel tanks shall be adequately supported and braced to prevent movement. Marine inspector observed the port side fuel tank securing straps were wasted and were not adequately braced. Vessel to install proper bracing to prevent movement. OLD T: 46 CFR 182.15-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 21 June 2024
Resolution: Brackets in place to secure tank
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 June 2024 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel vessel must be marked on some clearly visible exterior part of the stern of the vessel. Marine inspector observed No vessel name or hailing port marked on vessels stern, starboard, or port side. Vessel to clearly mark vessel name "TIKI MERMAID" and hailing port that is listed on Certificate of Documentation in the locations stated. Markings must be no less than 4 inches in height.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 21 June 2024
Resolution: Name/Hailing port marked on stern
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 June 2023 Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. Stbd aft rail course clip is deteriorated. 46CFR177.35-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 June 2023
Resolution: Replaced clip; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2023 Resolved
Vessels shall be inspected for compliance with the standards required by this subchapter. For items not covered by standards in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. MI observed excessive water from shaft packing. 46CFR176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 June 2023
Resolution: Packing tightened, stopping water ingress; all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 June 2023 Resolved
When installed in a machinery space, a fixed carbon dioxide system must meet the following requirements. The quantity of carbon dioxide in kilograms (pounds) that the system must be capable of providing to a space must not be less than the gross volume of the space. MI observed two holes (aprox 1-3" wide) in the engine room compartment. 46CFR181.410(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 June 2023
Resolution: Holes covered; all sat. See documents for pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2022 Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter. The grab line of the ring buoy is deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2022
Resolved 16 June 2022
Resolution: New ring buoy was procured. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2022 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. The starboard shaft is leaking water.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2022
Resolved 16 June 2022
Resolution: Starboard shaft is no longer leaking water. All sat
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 March 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts and publications. Vessel did not have any publications on board. Vessel was able to purchase and get on board all required publications prior to the end of the inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 11 March 2021
Resolved 11 March 2021
Resolution: Vessel purchased all the required publications prior to the end of the inspection, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2019 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel exceeded 3 month interval on 14JUN2019. Vessel required to undergo satisfactory annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2019
Resolved 19 July 2019
Resolution: Vessel completed satisfactory annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019 Resolved
Fuel shut off valves installed so as to close against the fuel flow shall be fitted in the fuel supply lines. Port emergency fuel shut off valve in inoperable. Demonstrate repair/replacement of valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2019
Resolved 19 July 2019
Resolution: F/o shutoff found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 July 2019 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any water tight compartment. Vessel could not drain water from forward most space. After a protracted delay vessel was able to dewater the space.
Action required: 10 - Deficiency Rectified
Resolved 16 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 March 2019 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry dock examination and an internal structure at least once every two years. Vessel is currently overdue for require dry dock examination and must complete a satisfactory dry dock examination prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2019
Resolution: Completed Hull Exam
Engineering › Bilge Water Management System › Pump
Issued 13 June 2018 Resolved
Provide proof of an operating bilge pumping system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 13 June 2018 Resolved
Porvide proof of an operating port engine tachometer.
Action required: 705 - Other - as specified
Due 13 July 2018
Resolved 15 June 2018
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 13 June 2018 Resolved
Provide one Type I adult PFD. Total persons onboard is reduced by 1 person. Total persons is reduced to 64.
Action required: 705 - Other - as specified
Due 13 June 2018
Resolved 13 June 2018
Resolution: Procured and stenciled new life jacket.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 June 2017 Resolved
Provide a visual indicator at the operating station for any automatic bilge pump to indicate when operating. 46CFR182.530(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 11 July 2017
Resolution: Operator installed a visual indicator at the operating station for all automatic bilge pumps to indicate when operating.